PubMed Health⌕ Search

Biomedical subjects

Dongqing Li

Publications and source records attributed to Dongqing Li.

At least 37 records · Page 2Linked to original sources

Electrokinetically based approach for single-nucleotide polymorphism discrimination using a microfluidic device.

In this work, we describe and implement an electrokinetic approach for single-nucleotide polymorphism (SNP) discrimination using a PDMS/glass-based microfluidic chip. The technique takes advantage of precise control of the coupled thermal (Joule heating), shear (electroosmosis), and electrical (electrophoresis) energies present at an array of probes afforded by the application of external electrical potentials. Temperature controllers and embedded thermal devices are not required. The chips can be easily and inexpensively fabricated using standard microarray printing methods combined with soft-lithography patterned PDMS fluidics, making these systems easily adaptable to applications using higher density arrays. Extensive numerical simulations of the coupled flow and thermal properties and microscale thermometry experiments are described and used to characterize the in-channel conditions. It was found that optimal conditions for SNP detection occur at a lower temperature on-chip than for typical microarray experiments, thereby revealing the importance of the electrical and shear forces to the overall process. To demonstrate the clinical utility of the technique, the detection of single-base pair mutations in the survival motor neuron gene, associated with the childhood disease spinal muscular atrophy, is conducted.

Cyclic AMP Response Element-Binding Protein↗

Force acting on a dielectric particle in a concentration gradient by ionic concentration polarization under an externally applied DC electric field.

There is a concentration-polarization (CP) force acting on a particle submerged in an electrolyte solution with a concentration (conductivity) gradient under an externally applied DC electric field. This force originates from the two mechanisms: (i) gradient of electrohydrodynamic pressure around the particle developed by the Coulombic force acting on induced free charges by the concentration polarization, and (ii) dielectric force due to nonuniform electric field induced by the conductivity gradient. A perturbation analysis is performed for the electric field, the concentration field, and the hydrodynamic field, under the assumptions of creeping flow and small concentration gradient. The leading order component of this force acting on a dielectric spherical particle is obtained by integrating the Maxwell and the hydrodynamic stress tensors. The analytical results are validated by comparing the surface pressure and the skin friction to those of a numerical analysis. The CP force is proportional to square of the applied electric field, effective for electrically neutral particles, and always directs towards the region of higher ionic concentration. The magnitude of the CP force is compared to that of the electrophoretic and the conventional dielectrophoretic forces.

Journal Article↗

Effect of surfactant on interfacial gas transfer studied by axisymmetric drop shape analysis-captive bubble (ADSA-CB).

A new method combining axisymmetric drop shape analysis (ADSA) and a captive bubble (CB) is proposed to study the effect of surfactant on interfacial gas transfer. In this method, gas transfer from a static CB to the surrounding quiescent liquid is continuously recorded for a short period (i.e., 5 min). By photographical analysis, ADSA-CB is capable of yielding detailed information pertinent to the surface tension and geometry of the CB, e.g., bubble area, volume, curvature at the apex, and the contact radius and height of the bubble. A steady-state mass transfer model is established to evaluate the mass transfer coefficient on the basis of the output of ADSA-CB. In this way, we are able to develop a working prototype capable of simultaneously measuring dynamic surface tension and interfacial gas transfer. Other advantages of this method are that it allows for the study of very low surface tensions (<5 mJ/m2) and does not require equilibrium of gas transfer. Consequently, reproducible experimental results can be obtained in a relatively short time. As a demonstration, this method was used to study the effect of lung surfactant on oxygen transfer. It was found that the adsorbed lung surfactant film shows a retardation effect on oxygen transfer, similar to the behavior of a pure DPPC film. However, this retardation effect at low surface tensions is less than that of a pure DPPC film.

Journal Article↗

Analytical study of Joule heating effects on electrokinetic transportation in capillary electrophoresis.

Electric fields are often used to transport fluids (by electroosmosis) and separate charged samples (by electrophoresis) in microfluidic devices. However, there exists inevitable Joule heating when electric currents are passing through electrolyte solutions. Joule heating not only increases the fluid temperature, but also produces temperature gradients in cross-stream and axial directions. These temperature effects make fluid properties non-uniform, and hence alter the applied electric potential field and the flow field. The mass species transport is also influenced. In this paper we develop an analytical model to study Joule heating effects on the transport of heat, electricity, momentum and mass species in capillary-based electrophoresis. Close-form formulae are derived for the temperature, applied electrical potential, velocity, and pressure fields at steady state, and the transient concentration field as well. Also available are the compact formulae for the electric current and the volume flow rate through the capillary. It is shown that, due to the thermal end effect, sharp temperature drops appear close to capillary ends, where sharp rises of electric field are required to meet the current continuity. In order to satisfy the mass continuity, pressure gradients have to be induced along the capillary. The resultant curved fluid velocity profile and the increase of molecular diffusion both contribute to the dispersion of samples. However, Joule heating effects enhance the sample transport velocity, reducing the analysis time in capillary electrophoretic separations.

Electrophoresis, Capillary↗

Band-broadening in capillary zone electrophoresis with axial temperature gradients.

It is widely accepted that Joule heating effects yield radial temperature gradients in capillary zone electrophoresis (CZE). The resultant parabolic profile of electrophoretic velocity of analyte molecules is believed to increase the band-broadening via Taylor-Aris dispersion. This typically insignificant contribution, however, cannot explain the decrease in separation efficiency at high electric fields. We show that the additional band-broadening due to axial temperature gradients may provide the answer. These axial temperature variations result from the change of heat transfer condition along the capillary, which is often present in CZE with thermostating. In this case, the electric field becomes nonuniform due to the temperature dependence of fluid conductivity, and hence the induced pressure gradient is brought about to meet the mass continuity. This modification of the electroosmotic flow pattern can cause significant band-broadening. An analytical model is developed to predict the band-broadening in CZE with axial temperature gradients in terms of the theoretical plate height. We find that the resultant thermal plate height can be very high and even comparable to that due to molecular diffusion. This thermal plate height is much higher than that due to radial temperature gradients alone. The analytical model explains successfully the phenomena observed in previous experiments.

Electrophoresis, Capillary↗

Focused electrophoretic motion and selected electrokinetic dispensing of particles and cells in cross-microchannels.

The electrokinetic focusing and the resultant accelerated electrophoretic motion of polystyrene particles and red blood cells were visualized in microfluidic cross-channels. The experimentally measured width of the focused stream and the measured velocity increase of particles and cells at different voltage ratios follow the proposed analytical formula within the experimental error. The attained velocity increase is insensitive to the particle size, particle property (i.e., particle or cell), and particle trajectory. By solving the electrical potential field in the cross-channel at the experimental conditions, we demonstrate that the squeezed electrical field lines in the channel intersection determine the shape of the focused stream, and the nonuniform distribution of axial electrical field strength underlies the variation of particle/cell electrophoretic velocity through the focusing region. However, the dielectrophoretic force resulting from the nonuniform electrical field in the intersection seems to push the acceleration region of particles and cells slightly in the downstream direction. We have also achieved the single particle/cell dispensing by instantly triggering an electrical pulse perpendicular to the focused particulate flow in a double-cross microchannel. The electrokinetic manipulation of particle/cell in microchannels demonstrated in this work can be used for developing integrated lab-on-a-chip devices for studies of cells.

Animals↗

An electrokinetically-controlled immunoassay for simultaneous detection of multiple microbial antigens.

An electrokinetically-controlled heterogeneous immunoassay microchip for multiple analyte detection was developed in this study. Numerical simulation was employed to study the transport process in a microfluidic network (microFN). The operation parameters obtained from numerical simulation was then applied to immunoassay experiment. The effectiveness of the automatic electrokinetic control was demonstrated in a separate experiment using fluorescein dye. The immunoassay microchip was made of poly(dimethylsiloxane)(PDMS)/PDMS-coated glass using soft lithography and replica molding. Multi-antigen immobilization was accomplished by adsorbing the antigen molecules onto a PDMS-coated glass slide and by using a microFN. Immobilized lysate antigen of Escherichia coli O157: H7 at different concentrations was assayed and the lower detect limit was 3 microg/mL. The assay also displayed very good specificity, when different microbial lysate antigens were immobilized, including Escherichia coli and Helicobacter pylori, and the primary and secondary antibodies were mixtures of different species. The time required for the immunoassay, from antigen coating to signal detection, was only one hour. While still an un-optimized prototype, this automatic-operating, high-throughput immunoassay microchip shows a great potential in detecting multiple pathogenic infections efficiently for clinical applications.

Antigens, Bacterial↗

Development of a nanoparticle-labeled microfluidic immunoassay for detection of pathogenic microorganisms.

The light-scattering properties of submicroscopic metal particles ranging from 40 to 120 nm in diameter have recently been investigated. These particles scatter incident white light to generate monochromatic light, which can be seen either by the naked eye or by dark-field microscopy. The nanoparticles are well suited for detection in microchannel-based immunoassays. The goal of the present study was to detect Helicobacter pylori- and Escherichia coli O157:H7-specific antigens with biotinylated polyclonal antibodies. Gold particles (diameter, 80 nm) functionalized with a secondary antibiotin antibody were then used as the readout. A dark-field stereomicroscope was used for particle visualization in poly(dimethylsiloxane) microchannels. A colorimetric quantification scheme was developed for the detection of the visual color changes resulting from immune reactions in the microchannels. The microchannel immunoassays reliably detected H. pylori and E. coli O157:H7 antigens in quantities on the order of 10 ng, which provides a sensitivity of detection comparable to those of conventional dot blot assays. In addition, the nanoparticles within the microchannels can be stored for at least 8 months without a loss of signal intensity. This strategy provides a means for the detection of nanoparticles in microchannels without the use of sophisticated equipment. In addition, the approach has the potential for use for further miniaturization of immunoassays and can be used for long-term archiving of immunoassays.

Bacteria↗

Influence of the three-dimensional heterogeneous roughness on electrokinetic transport in microchannels.

Surface roughness has been considered as a passive means of enhancing species mixing in electroosmotic flow through microfluidic systems. It is highly desirable to understand the synergetic effect of three-dimensional (3D) roughness and surface heterogeneity on the electrokinetic flow through microchannels. In this study, we developed a three-dimensional finite-volume-based numerical model to simulate electroosmotic transport in a slit microchannel (formed between two parallel plates) with numerous heterogeneous prismatic roughness elements arranged symmetrically and asymmetrically on the microchannel walls. We consider that all 3D prismatic rough elements have the same surface charge or zeta potential, the substrate (the microchannel wall) surface has a different zeta potential. The results showed that the rough channel's geometry and the electroosmotic mobility ratio of the roughness elements' surface to that of the substrate, epsilon(mu), have a dramatic influence on the induced-pressure field, the electroosmotic flow patterns, and the electroosmotic flow rate in the heterogeneous rough microchannels. The associated sample-species transport presents a tidal-wave-like concentration field at the intersection between four neighboring rough elements under low epsilon(mu) values and has a concentration field similar to that of the smooth channels under high epsilon(mu) values.

Journal Article↗

Electrokinetically controlled DNA hybridization microfluidic chip enabling rapid target analysis.

Biosensors and more specifically biochips exploit the interactions between a target analyte and an immobilized biological recognition element to produce a measurable signal. Systems based on surface nucleic acid hybridization, such as microarrays, are particularly attractive due to the high degree of selectivity in the binding interactions. One of the drawbacks of this reaction is the relatively long time required for complete hybridization to occur, which is often the result of diffusion-limited reaction kinetics. In this work, an electrokinetically controlled DNA hybridization microfluidic chip will be introduced. The electrokinetic delivery technique provides the ability to dispense controlled samples of nanoliter volumes directly to the hybridization array (thereby increasing the reaction rate) and rapidly remove nonspecific adsorption, enabling the hybridization, washing, and scanning procedures to be conducted simultaneously. The result is that all processes from sample dispensing to hybridization detection can be completed in as little as 5 min. The chip also demonstrates an efficient hybridization scheme in which the probe saturation level is reached very rapidly as the targets are transported over the immobilized probe site enabling quantitative analysis of the sample concentration. Detection levels as low as 50 pM have been recorded using an epifluorescence microscope.

Adsorption↗

Development of a novel microfluidic immunoassay for the detection of Helicobacter pylori infection.

The miniaturization of laboratory processes offers substantial advantages over traditional techniques in terms of cost, speed, and potential for multistage automation. To date, only a few studies have reported successful microfluidics-based immunoassays, most of which rely on fluorescence detection technologies. The goal of this study was to develop a poly(dimethylsiloxane) microfluidics-based immunoassay methodology and a versatile colorimetric quantification scheme for the detection of visual colour changes resulting from immune reactions in microchannels. The novel immunoassay technique was applied towards the detection of Helicobacter pylori infection using 20 human serum samples of known infection status, and results compared with conventional nitrocellulose membrane-based dot-ELISA. The microchannel immunoassay reliably detected H. pylori antigens in quantities on the order of 10 ng, which provides a sensitivity of detection comparable to conventional dot-blot assays. Sensitivity was 100%, specificity was 90%, positive predictive value 91%, and negative predictive value 100%, with an overall accuracy of 95%. The software developed generated results that were consistent with visual observations and by automatically taking into account background intensity changes, the software minimized subjectivity. Volumes of solutions used were 100-fold less compared with conventional immunoassays. Miniaturization of the ELISA using this technique provides a means for the accurate diagnosis of microbial infection while minimizing waste production.

Antigens, Bacterial↗

Electroviscous effects on pressure-driven flow of dilute electrolyte solutions in small microchannels.

A fundamental understanding of the flow characteristics of electrolyte solutions in microchannels is critical to the design and control of microfluidic devices. Experimental studies have shown that the electroviscous effect is appreciable for a dilute solution in a small microchannel. However, the experimentally observed electroviscous effects cannot be predicted by the traditional theoretical model, which involves the use of the Boltzmann distribution for the ionic concentration field. It has been found that the Boltzmann distribution is not applicable to systems with dilute electrolyte solutions in small microchannels because it violates the ion number conservation condition. A new theoretical model is developed in this paper using the Nernst equation and the ion number conservation, instead of the Boltzmann distribution, to obtain the ionic concentration field. The ionic concentration field, electrical potential field, and flow field in small microchannels are studied using the model developed here. In order to verify this model, the model-predicted dP/dx (applied pressure gradient) Re (Reynolds number) relationship is compared with the experimentally determined dP/dx approximately Re relationship. Strong agreement between the model predictions and the experimental results supports this model.

Journal Article↗

Heterogeneous surface charge enhanced micromixing for electrokinetic flows.

Enhancing the species mixing in microfluidic applications is key to reducing analysis time and increasing device portability. The mixing in electroosmotic flow is usually diffusion-dominated. Recent numerical studies have indicated that the introduction of electrically charged surface heterogeneities may augment mixing efficiencies by creating localized regions of flow circulation. In this study, we experimentally visualized the effects of surface charge patterning and developed an optimized electrokinetic micromixer applicable to the low Reynolds number regime. Using the optimized micromixer, mixing efficiencies were improved between 22 and 68% for the applied potentials ranging from 70 to 555 V/cm when compared with the negatively charged homogeneous case. For producing a 95% mixture, this equates to a potential decrease in the required mixing channel length of up to 88% for flows with Péclet numbers between 190 and 1500.

Journal Article↗

3-D transient electrophoretic motion of a spherical particle in a T-shaped rectangular microchannel.

This paper considers the electrophoretic motion of a spherical particle in an aqueous electrolyte solution in a T-shaped rectangular microchannel, where the size of the channel is close to that of the particle. This is a complicated transient process where the electric field, the flow field, and the particle motion are coupled together. A theoretical model was developed to investigate the influences of the applied electric potentials, the zeta potentials of the channel and the particle, and the size of the particle on the particle motion. A direct numerical simulation method using the finite element method is employed. This method employs a generalized Galerkin finite element formulation that incorporates both equations of the fluid flow and equations of the particle motion into a single variational equation where the hydrodynamic interactions are eliminated. The ALE method is used to track the surface of the particle at each time step. The numerical results show that the electric field in the T-shaped microchannel is influenced by the presence of the particle, and that the particle motion is influenced by the applied electric potentials and the zeta potentials of the channel and the particle. The path of the particle motion is dominated by the local electric field and the ratio of the zeta potential of the channel to that of the particle. The particle's velocity is also dependent on its size in a small channel.

Electrophoresis↗

Ionic strength-dependent pK shift in the helix-coil transition of grafted poly(L-glutamic acid) layers analyzed by electrokinetic and ellipsometric measurements.

Surface-bound layers of poly(L-glutamic acid) prepared by a recently described "grafting-from" method were analyzed with respect to electrical charging and structural alterations upon variation of pH and concentration of the background electrolyte in aqueous solutions. The microslit electrokinetic setup (MES) was utilized for the combined determination of zeta potential and surface conductivity on the basis of streaming potential and streaming current measurements at polypeptide layers in contact with aqueous electrolyte solutions of varied composition. In situ ellipsometry was applied at similar samples immersed in identical aqueous solutions to investigate the influence of the solution pH on the structure of the polypeptide layers. Zeta potential and Dukhin number versus pH plots revealed the dissociation behavior of the surface-bound polypeptides indicating a significant shift of the pK of their acidic side chains correlating with the concentration of the background electrolyte potassium chloride and the related variation of the Debye screening length. Surface conductivity data pointed at a more expanded structure of the polypeptide layer in the fully dissociated state as an increased ion conductance in this part of the interface was determined. The occurrence of a strong increase of the thickness and a corresponding decrease of the refractive index for the coil state of the layer strongly supports the findings of the electrokinetic measurements. This fully reversible "switching" of the layer structure was attributed to helix-coil transitions within the grafted polypeptides induced by the dissociation of carboxylic acid functions of the polypeptide side chains. The shift of the "switching pH" of the surface-bound poly(L-glutamic acid) layers at varied concentrations of the background electrolyte was interpreted as a result of the pK shift of the carboxylic acid groups of the polypeptide side chains. The observed patterns prove that the electrostatic interactions causing this shift occur within but not between the grafted chains.

Electrochemistry↗

Electroosmotic flow with Joule heating effects.

Electroosmotic flow with Joule heating effects was examined numerically and experimentally in this work. We used a fluorescence-based thermometry technique to measure the liquid temperature variation caused by Joule heating along a micro capillary. We used a caged-fluorescent dye-based microfluidic visualization technique to measure the electroosmotic velocity profile along the capillary. Sharp temperature drops close to the two ends and a high-temperature plateau in the middle of the capillary were observed. Correspondingly, concave-convex-concave velocity profiles were observed in the inlet-middle-outlet regions of a homogeneous capillary. These velocity perturbations were due to the induced pressure gradients resulting from axial variations of temperature. The measured liquid temperature distribution and the electroosmotic velocity profile along the capillary agree well with the predictions of a theoretical model developed in this paper.

Journal Article↗

A miniaturized high-voltage integrated power supply for portable microfluidic applications.

In this work a portable microfluidic device with a reusable integrated high voltage power supply is presented, which allows for quick exchange of inexpensive disposable poly(dimethylsiloxane)(PDMS) microfluidic chips on a carrier only slightly larger than a microscope slide. The device is powered by an onboard MN21 cell battery (5 mm radius, 30 mm long) and is demonstrated through the rapid and controlled transport of a fluorescent dye through an expansion chamber geometry. Power consumption experiments demonstrate the device's ability to complete over 40 dispense-flushing cycles on a single battery.

Dimethylpolysiloxanes↗

Development of a novel hand-held immunoassay for the detection of enterohemorrhagic Escherichia coli O157:H7.

Escherichia coli O157:H7 is an important human pathogen responsible for numerous outbreaks of hemorrhagic colitis and hemolytic uremic syndrome world-wide. A portable detection device is needed for field testing and point-of-care testing. Poly(dimethylsiloxane) (PDMS) is a solid substrate well suited for adsorption of macromolecules. The purpose of this study was to develop a hand-held enzyme-linked immunosorbent assay (ELISA) for the detection of E. coli O157:H7 antigens. The prototype consisted of three modules: one for loading reagents, a second for immunosensor detection, and a third for discharge of wastes. Reagent delivery was achieved by using 1-ml syringes embedded within the loading module. The detection module was based on a PDMS layer on which varying concentrations of E. coli O157:H7 antigens, and negative controls (Lactobacillus rhamnosus R011 and phosphate-buffered saline) were passively adsorbed. Commercially available goat anti-E. coli O157:H7 antibody was used as a primary antibody, a donkey anti-goat IgG conjugated with horseradish peroxidase was used as a secondary antibody, and a precipitating substrate was employed for colorimetric detection. Results obtained with the prototype were compared to those obtained using a conventional nitrocellulose membrane-based immunoassay. Using the prototype, E. coli O157:H7 antigens, in quantities from 4 to 400 ng, were accurately detected. This detection limit was comparable to that observed using conventional dot-blot assays. The PDMS layer could be re-used without loss of sensitivity. Colorimetric detection could be visualized readily without the need for sophisticated equipment. Furthermore, this device can be adapted to perform diagnostics for other microbial pathogens currently detected using immunoassay methodology.

Colorimetry↗