A method for dynamic system characterization using hydraulic series resistance.

The pressure required to drive flow through a microfluidic device is an important characteristic of that device. We present a method to measure the flow rate through microfluidic components and systems, including micropumps and microvalves. The measurement platform is composed of two pressure sensors and a glass tube, which provides series resistance. The principle of the measurement is the fluid dynamical equivalent of Ohm's law, which defines the relationship between current, resistance, and voltage that are analogues to flow rate, hydraulic resistance, and pressure drop, respectively. Once the series resistance is known, it is possible to compute the flow rate through a device based on pressure alone. In addition, the dynamic system characteristics of the device-resistance and capacitance-can be computed. The benefits of this method are its simple configuration, capability of measuring flow rate accurately from the more easily measured pressure, and the ability to predict the dynamic response of microfluidic devices.

Microfluidic Analytical Techniques↗

Do-it-yourself microelectrophoresis chips with integrated sample recovery.

We present a microelectrophoresis chip that is simple to fabricate using the microfluidic tectonics (microFT) platform (Beebe, D. J. et al., Proc. Natl. Acad. Sci. USA 2000, 97, 13488-13493; Agarwal, A. K. et al.,. J. Micromech. Microeng. 2006, 16, 332-340). The device contains a removable capillary insert (RCI) for easy sample collection after separation (Atencia, J. et al.,. Lab Chip 2006, DOI: 10. 1039/b514068d). Device construction is accomplished in less than 20 min without specialized equipment traditionally associated with microelectrophoresis chip construction. microFT was used to build a PAGE device utilizing two orthogonal microchannels. One channel performs standard separations, while the second channel serves as an access point to remove bands of interest from the chip via the RCI. The RCI contains an integrated electrode that facilitates the removal of bands using electrokinetic techniques. The device was characterized using prestained proteins (Pierce BlueRanger and TriChromRanger). Samples were loaded into the microelectrophoresis device via a standard micropipette. An electrical field of 40 V/cm was used to separate and collect the proteins. The microPAGE device is simple to fabricate, benefits from microscale analysis, and includes an on-chip collection scheme that interfaces the macroworld with the microworld.

Electrophoresis, Microchip↗

Microfluidic operations using deformable polymer membranes fabricated by single layer soft lithography.

We show that it is possible to use single layer soft lithography to create deformable polymer membranes within microfluidic chips for performing a variety of microfluidic operations. Single layer microfluidic chips were designed, fabricated, and characterized to demonstrate pumping, sorting, and mixing. Flow rates as high as 0.39 microl min(-1) were obtained by peristaltic pumping using pneumatically-actuated membrane devices. Sorting was attained via pneumatic actuation of membrane units placed alongside the branch channels. An active mixer was also demonstrated using single-layer deformable membrane units.

Equipment Design↗

Microfluidic tectonics platform: A colorimetric, disposable botulinum toxin enzyme-linked immunosorbent assay system.

A fabrication platform for realizing integrated microfluidic devices is discussed. The platform allows for creating specific microsystems for multistep assays in an ad hoc manner as the components that perform the assay steps can be created at any location inside the device via in situ fabrication. The platform was utilized to create a prototype microsystem for detecting botulinum neurotoxin directly from whole blood. Process steps such as sample preparation by filtration, mixing and incubation with reagents was carried out on the device. Various microfluidic components such as channel network, valves and porous filter were fabricated from prepolymer mixture consisting of monomer, cross-linker and a photoinitiator. For detection of the toxoid, biotinylated antibodies were immobilized on streptavidin-functionalized agarose gel beads. The gel beads were introduced into the device and were used as readouts. Enzymatic reaction between alkaline phosphatase (on secondary antibody) and substrate produced an insoluble, colored precipitate that coated the beads thus making the readout visible to the naked eye. Clinically relevant amounts of the toxin can be detected from whole blood using the portable enzyme-linked immunosorbent assay (ELISA) system. Multiple layers can be realized for effective space utilization and creating a three-dimensional (3-D) chaotic mixer. In addition, external materials such as membranes can be incorporated into the device as components. Individual components that were necessary to perform these steps were characterized, and their mutual compatibility is also discussed.

Antibodies↗