PubMed Health⌕ Search

Biomedical subjects

Doo Soo Chung

Publications and source records attributed to Doo Soo Chung.

8 recordsLinked to original sources

Dual stacking of unbuffered saline samples, transient isotachophoresis plus induced pH junction focusing.

A dual stacking mechanism based on transient isotachophoresis (TITP) and induced pH junction focusing is demonstrated as a means to increase the concentration sensitivity in capillary electrophoresis of highly saline samples. When stacking was carried out with an unbuffered saline sample of fluorescein between two zones of low mobility background electrolyte at high pH under an electric field of reverse polarity, two transient peaks at both boundaries of the sample zone were observed. One peak at the rear boundary could be inferred as a transient isotachophoretic stacked zone. Through computer simulations of an unbuffered sample with a high concentration of sodium chloride, we showed that the fast moving zones of sodium and chloride ions induced pH changes at both boundaries to satisfy the electroneutrality condition and that the peak at the front boundary was due to the induced pH junction. To verify the pH changes, an indicator, thymol blue, was added to an NaCl solution and the color changes under an electric field were observed. The proposed mechanism was supported by observing the dual stacking procedure for an unbuffered sample of 4-nitrophenol and measuring additional sensitivity enhancements by dual stacking for ten weakly acidic compounds. For the ten analytes including nucleoside phosphates, every dual stacking of an unbuffered sample exhibited an additional enhancement up to 86% larger than that of usual transient isotachophoresis of the corresponding buffered sample without loss of separation efficiency and reproducibility. Therefore, it would be useful to skip over buffering in sample preparation for TITP, contrary to the general recommendation.

Electrophoresis↗

Capillary electrophoresis of trace metals in highly saline physiological sample matrices.

Trace metal ions in highly saline samples such as urine were determined with capillary electrophoresis (CE) without desalting or off-line preconcentration. By mixing with a dye, 4-(2-pyridylazo) resorcinol (PAR), the metal ions were converted into anionic complexes having strong absorbance near 500 nm. A large volume of the metal-PAR complex sample solution injected into a coated capillary was stacked isotachophoretically and separated under a reverse potential. The salt anion (chloride) and PAR in the sample matrix acted as the leading and terminating electrolytes, respectively. In a sample containing a 250 mM NaCl matrix, more than 400-fold enhancement in the absorbance detector response was realized compared to the normal CE injection mode. Combination of the dye complexation and isotachophoretic stacking provided excellent detection limits (S/N = 3) for three trace metal ions in the low ppb range (Fe(2+), 0.7 ppb, Ni(2+), 0.4 ppb; Zn(2+), 1.2 ppb) with absorbance detection. The migration time reproducibility was excellent (relative standard deviations: standard samples < 1%, urine samples approximately 1%). The proposed method is convenient and fast, and the sample analysis can be completed within 20 min.

Animals↗

Investigation of the factors influencing the release rates of cyclosporin A-loaded micro- and nanoparticles prepared by high-pressure homogenizer.

An oil-in-water solvent evaporation method was used to prepare cyclosporin A (CyA)-loaded particles varying in size (nanoparticles, 'small-sized' microparticles, 'large-sized' microparticles), polymer compositions [poly(D,L-lactide-co-glycolic acid) (PLGA) 50/50, PLGA 85/15, poly(D,L-lactic acid) (PLA)] and additive fatty acid ester (ethyl myristate; EM). The particles were characterized for drug loading and entrapment efficiency by high-performance liquid chromatography, particle size by dynamic light scattering and surface morphology by scanning electron microscopy (SEM). In vitro release kinetics were studied using a modified dialysis method. The results showed drug loadings ranging from 6.48 to 9.01% with high encapsulation efficiency (71.2-98.9%). SEM studies showed discrete and spherical particles with smooth surfaces, whereas rather gross surface defects resulted from the incorporation of EM as an additive. The release profiles of various formulations approximated zero-order release kinetics in the first 3 weeks with a negligible initial burst. In general, the smaller the particle size and the higher the glycolic acid content in the copolymer, the faster the release of CyA. The effect of EM on the release profile appeared to be rather complex since an increased release rate was observed from EM containing PLGA 50/50 particles, whereas the incorporation of EM into the PLGA 85/15 and PLA particles led to a decreased release rate. Further investigation needs to be performed to elucidate the reason why EM influences the CyA release differently depending on the particle size and polymer type.

Cyclosporine↗

Large-volume stacking in capillary electrophoresis using a methanol run buffer.

Highly sensitive nonaqueous capillary electrophoresis of weakly acidic organic compounds has been performed using methanol as the run buffer solvent. Methanol provided appropriate suppression of the electroosmotic flow and an increase in the electrophoretic mobilities of anionic solutes compared to water. These two effects allowed large-volume stacking using the electroosmotic flow pump (LVSEP) to be achieved for larger anions using a bare fused-silica capillary under an electric field of reverse polarity, whereas only fast-moving small anions were previously known to be suitable for LVSEP in aqueous media. A field-enhanced sample injection of an additional amount of analytes during the solvent plug removal further enhanced the limits of detection to below the nanomolar range with conventional UV absorption detection. Under optimum conditions, excellent linear responses and reproducibility in the migration times together with the corrected peak areas for ten analytes were obtained in the concentration range of 10-100 nM.

Buffers↗

Chiral separation of gemifloxacin in sodium-containing media using chiral crown ether as a chiral selector by capillary and microchip electrophoresis.

Chiral crown ether, (+)-(18-crown-6)-tetracarboxylic acid (18C6H(4)), is an effective chiral selector for resolving enantiomeric primary amines owing to the difference in affinities between 18C6H(4) and each of the amine enantiomers. In addition to the destacking effect of sodium ion in the sample solution, the strong affinity of sodium ion to the polyether ring of crown ether is unfavorable to chiral capillary electrophoresis using 18C6H(4) as a chiral selector. In this report, the chiral separation of gemifloxacin dissolved in a saline sample matrix using 18C6H(4) was investigated. Adding a chelating agent, ethylenediaminetetraacetic acid (EDTA), to the run buffer greatly improved the separation efficiencies and peak shapes. The successful chiral separation of gemifloxacin in a urinary solution was demonstrated for both capillary and microchip electrophoresis.

Anti-Infective Agents↗

First principles calculations of the tautomers and pK(a) values of 8-oxoguanine: implications for mutagenicity and repair.

8-Oxoguanine is a mutagenic oxidative damage product of guanine that has been the subject of many experimental studies. Despite numerous references to this damaged base, its precise configuration or population of configurations in equilibrium are unknown, as it can be drawn in over 100 potential neutral and ionized tautomeric forms. The structural uncertainty surrounding 8-oxoguanine complicates mechanistic studies of its mutagenicity and capacity to be recognized for repair. Experimental measurements on the tautomeric equilibria and pK(a) values of 8-oxoguanine are complicated by its insolubility in water. Therefore, we used first principles quantum mechanics (density functional theory, B3LYP, in combination with the Poisson-Boltzmann continuum-solvation model) to investigate the relative stabilities and site-specific pK(a) values of various neutral and ionized tautomers of 8-oxoguanine. We show that the major tautomer of neutral 8-oxoguanine in aqueous solution is the 6,8-diketo form 2, and that 8-oxoguanine has increased acidity at N1 relative to guanine. Our calculations on 2'-deoxyguanosine-3',5'-bisphosphate and its 8-oxo analogue support the accepted conclusion that repulsion between the O8 of 8-oxoguanine and O5' of the backbone sugar promote 8-oxoguanine:adenine pairings in the syn:anti conformation. Further, we show that the N7 proton of 8-oxoguanine is difficult to remove either through tautomerization or ionization, consistent with its involvement as an important landmark in distinguishing guanine from 8-oxoguanine. The possibility of additional structural landmarks that distinguish 8-oxoguanine from guanine, and a possible mechanism for glycosylase removal of 8-oxoguanine are discussed.

DNA Damage↗

Large-volume sample stacking in nonaqueous capillary electrophoresis using alcoholic run buffers.

A straightforward method for stacking an extremely large volume of a sample solution containing weakly acidic organic compounds was developed. By using alcohols such as methanol, ethanol, and 1-propanol as run buffer solvents, the electroosmotic flow was suppressed, so that analyte anions could proceed to the outlet vial against the electroosmotic flow under a reverse voltage. This effect made large-volume sample stacking possible for large anions using a bare, fused-silica capillary without intermediate polarity switching. The detection limits were in the low nanomolar range with conventional UV absorbance detection. The applicability of the technique to other organic solvents was also tested.

Alcohols↗