Effects of 3D sampling in (k, t)-space on temporal qualities of dynamic MRI.

3D (kx, ky, t)-space analysis is invoked to provide insights into dynamic magnetic resonance imaging (DMRI) with arbitrary k-space sampling trajectories. The effects of 3D sampling in (kx, ky, t) are analyzed theoretically and verified with computer simulation. The analyses show that a 3D sampling pattern that is more isotropic in (kx, ky, t)-space and denser around the (kx=0, ky=0, t)-line likely results in improved temporal qualities of DMRI. The isotropy of 3D sampling is quantified using Voronoi 3D cells and the isoperimetric theorem. This 3D sampling perspective provides a theoretical framework for understanding the temporal qualities of various DMRI methods.

Anisotropy↗

Dual-acquisition phase-sensitive fat-water separation using balanced steady-state free precession.

Balanced steady-state free precession (SSFP) sequences use fully re-focussed gradient waveforms to achieve a high signal and useful image contrast in short scan times. Despite these strengths, the clinical feasibility of balanced SSFP is still limited both by bright fat signal and by the signal voids that result from off-resonance effects such as field or susceptibility variations. A new method, dual-acquisition phase-sensitive SSFP, combines the signals from two standard balanced SSFP acquisitions to separate fat and water while simultaneously reducing the signal voids. The acquisitions are added in quadrature and then phase corrected using a simple algorithm before fat and water can be identified simply by the sign of the signal. This method is especially useful for applications at high field, where the RF power deposition, spatial resolution requirements and gradient strength limit the minimum repetition times. Finally, dual-acquisition phase-sensitive SSFP can be combined with other magnetization preparation schemes to produce specific image contrast in addition to separating fat and water signals.

Adipose Tissue↗

Fluid-attenuated inversion-recovery SSFP imaging.

PURPOSE: To describe and evaluate a fast, fluid-suppressed 2D multislice steady-state free precession (SSFP) neuroimaging sequence. MATERIALS AND METHODS: We developed a fast fluid-attenuated inversion-recovery SSFP sequence for use in neuroimaging. The inversion time (TI) was optimized to yield good cerebrospinal fluid (CSF) suppression while conserving white matter (WM)/lesion contrast across a broad range of flip angles. Multiple SSFP acquisitions were combined using the sum-of-squares (SOS) method to maximize SNR efficiency while minimizing SSFP banding artifacts. We compared our fluid-attenuated inversion-recovery (FLAIR) SSFP sequence with FLAIR fast spin-echo (FSE) in both normal subjects and a volunteer with multiple sclerosis. SNR measurements were performed to ascertain the SNR efficiency of each sequence. RESULTS: Our FLAIR SSFP sequence demonstrated excellent CSF suppression and good gray matter (GM)/WM contrast. Coverage of the entire brain (5-mm slices, 24-cm FOV, 256 x 192 matrix) was achieved with FLAIR SSFP in less than half the scan time of a corresponding FLAIR FSE sequence with similar SNR, yielding improvements of more than 50% in SNR efficiency. Axial scans of a volunteer with multiple sclerosis show clearly visible plaques and very good visualization of brain parenchyma. CONCLUSION: We have demonstrated the feasibility of a very fast fluid-suppressed neuroimaging technique using SSFP.

Algorithms↗

Single breath-hold whole-heart MRA using variable-density spirals at 3T.

Multislice breath-held coronary imaging techniques conventionally lack the coverage of free-breathing 3D acquisitions but use a considerably shorter acquisition window during the cardiac cycle. This produces images with significantly less motion artifact but a lower signal-to-noise ratio (SNR). By using the extra SNR available at 3 T and undersampling k-space without introducing significant aliasing artifacts, we were able to acquire high-resolution fat-suppressed images of the whole heart in 17 heartbeats (a single breath-hold). The basic pulse sequence consists of a spectral-spatial excitation followed by a variable-density spiral readout. This is combined with real-time localization and a real-time prospective shim correction. Images are reconstructed with the use of gridding, and advanced techniques are used to reduce aliasing artifacts.

Artifacts↗

Design and analysis of a practical 3D cones trajectory.

The 3D Cones k-space trajectory has many desirable properties for rapid and ultra-short echo time magnetic resonance imaging. An algorithm is presented that generates the 3D Cones gradient waveforms given a desired field of view and resolution. The algorithm enables a favorable trade-off between increases in readout time and decreases in the total number of required readouts. The resulting trajectory is very signal-to-noise ratio (SNR) efficient and has excellent aliasing properties. A rapid high-resolution ultra-short echo time imaging sequence is used to compare the 3D Cones trajectory to 3D projection reconstruction (3DPR) sampling schemes. For equivalent scan times, the 3D Cones trajectory has better SNR performance and fewer aliasing artifacts as compared to the 3DPR trajectory.

Algorithms↗

Designing long-T2 suppression pulses for ultrashort echo time imaging.

Ultrashort echo time (UTE) imaging has shown promise as a technique for imaging tissues with T2 values of a few milliseconds or less. These tissues, such as tendons, menisci, and cortical bone, are normally invisible in conventional magnetic resonance imaging techniques but have signal in UTE imaging. They are difficult to visualize because they are often obscured by tissues with longer T2 values. In this article, new long-T2 suppression RF pulses that improve the contrast of short-T2 species are introduced. These pulses are improvements over previous long-T2 suppression pulses that suffered from poor off-resonance characteristics or T1 sensitivity. Short-T2 tissue contrast can also be improved by suppressing fat in some applications. Dual-band long-T2 suppression pulses that additionally suppress fat are also introduced. Simulations, along with phantom and in vivo experiments using 2D and 3D UTE imaging, demonstrate the feasibility, improved contrast, and improved sensitivity of these new long-T2 suppression pulses. The resulting images show predominantly short-T2 species, while most long-T2 species are suppressed.

Adipose Tissue↗

Rapid cardiac-output measurement with ungated spiral phase contrast.

An ungated spiral phase-contrast (USPC) method was used to measure cardiac output (CO) rapidly and conveniently. The USPC method, which was originally designed for small peripheral vessels, was modified to assess CO by measuring flow in the ascending aorta (AA). The modified USPC used a 12-interleaf spiral trajectory to acquire full-image data every 283 ms with 2-mm spatial resolution. The total scan time was 5 s. For comparison, a triggered real-time (TRT) method was used to indirectly calculate CO by measuring left-ventricular (LV) volume. The USPC and TRT measurements from all normal volunteers agreed. In a patient with patent ductus arteriosus (PDA), high CO was measured with USPC, which agreed well with the invasive cardiac-catheterized measurement. In normal volunteers, CO dropped about 20-30% with Valsalva maneuvering, and increased about 100% after exercise. Continuous 28-s cycling between Valsalva maneuvering and free-breathing showed that USPC can temporally resolve physiological CO changes.

Adult↗

Noninvasive assessment of coronary vasodilation using magnetic resonance angiography.

OBJECTIVES: The purpose of this study was to investigate the use of coronary magnetic resonance angiography (MRA) for assessing human epicardial coronary artery vasodilation. BACKGROUND: Coronary vasodilation plays a vital role in the human coronary circulation. Previous studies of epicardial coronary vasodilation have used invasive coronary angiography. Coronary MRA may provide an alternative noninvasive method to directly assess changes in coronary size. METHODS: Thirty-two subjects were studied: 12 patients (age 55 +/- 18 years) and 20 healthy subjects (age 34 +/- 4 years). High-resolution multi-slice spiral coronary MRA (in-plane resolution of 0.52 to 0.75 mm) was performed before and after sublingual nitroglycerin (NTG). Quantitative analysis of coronary vasodilation was performed on cross-sectional images of the right coronary artery (RCA). A time-course analysis of coronary vasodilation was performed in a subset of eight subjects for 30 min after NTG. Signal-to-noise ratio was also measured on the in-plane RCA images. RESULTS: Coronary MRA demonstrated a 23% increase in cross-sectional area after NTG (16.9 +/- 7.8 mm2 to 20.8 +/- 8.9 mm2, p <0.0001), with significant vasodilation between 3 and 15 min after NTG on time-course analysis. The MRA measurements had low interobserver variability (< or =5%) and good correlation with X-ray angiography (r=0.98). The magnitude of vasodilation correlated with baseline cross-sectional area (r=0.52, p=0.03) and age (r=0.40, p=0.019). Post-NTG images also demonstrated a 31% improvement in coronary signal-to-noise ratio (p = 0.002). CONCLUSIONS: Nitroglycerin-enhanced coronary MRA can noninvasively measure coronary artery vasodilation and is a promising noninvasive technique to study coronary vasomotor function.

Adult↗

Rapid measurement of renal artery blood flow with ungated spiral phase-contrast MRI.

PURPOSE: To verify the potential of ungated spiral phase-contrast (USPC), which has been shown to provide accurate and reproducible time-averaged measurements of pulsatile flow, for rapid measurement of renal artery blood flow (RABF) in vivo. MATERIALS AND METHODS: The RABF rates of 11 normal human subjects and one patient with renal failure were measured with USPC within six seconds. RESULTS: Rapid USPC scans produced reproducible RABF measurements (SD < or = 9%) that agreed with the normal RABF rates known from the literature. The RABF rates of the patient with renal failure were substantially less (<50-65%) than the normal RABF rates. CONCLUSION: The results demonstrate that it is now possible to obtain rapid and consistent RABF measurements within six seconds with USPC.

Adult↗

Spiral balanced steady-state free precession cardiac imaging.

Balanced steady-state free precession (SSFP) sequences are useful in cardiac imaging because they achieve high signal efficiency and excellent blood-myocardium contrast. Spiral imaging enables the efficient acquisition of cardiac images with reduced flow and motion artifacts. Balanced SSFP has been combined with spiral imaging for real-time interactive cardiac MRI. New features of this method to enable scanning in a clinical setting include short, first-moment nulled spiral trajectories and interactive control over the spatial location of banding artifacts (SSFP-specific signal variations). The feasibility of spiral balanced SSFP cardiac imaging at 1.5 T is demonstrated. In observations from over 40 volunteer and patient studies, spiral balanced SSFP imaging shows significantly improved contrast compared to spiral gradient-spoiled imaging, producing better visualization of cardiac function, improved localization, and reduced flow artifacts from blood.

Artifacts↗

Variable-density one-shot Fourier velocity encoding.

In areas of highly pulsatile and turbulent flow, real-time imaging with high temporal, spatial, and velocity resolution is essential. The use of 1D Fourier velocity encoding (FVE) was previously demonstrated for velocity measurement in real time, with fewer effects resulting from off-resonance. The application of variable-density sampling is proposed to improve velocity measurement without a significant increase in readout time or the addition of aliasing artifacts. Two sequence comparisons are presented to improve velocity resolution or increase the velocity field of view (FOV) to unambiguously measure velocities up to 5 m/s without aliasing. The results from a tube flow phantom, a stenosis phantom, and healthy volunteers are presented, along with a comparison of measurements using Doppler ultrasound (US). The studies confirm that variable-density acquisition of kz-kv space improves the velocity resolution and FOV of such data, with the greatest impact on the improvement of FOV to include velocities in stenotic ranges.

Aorta, Abdominal↗

Broadband multicoil imaging using multiple demodulation hardware: a feasibility study.

Multiple receiver-coil data collection is an effective approach to reduce scan time. There are many parallel imaging techniques that reduce scan time using multiple receiver coils. One of these methods, partially parallel imaging with localized sensitivities (PILS), utilizes the localized sensitivity of each coil. The advantages of PILS over other parallel imaging methods include the simplicity of the algorithm, good signal-to-noise ratio (SNR) properties, and the fact that there is no additional complexity involved in applying the algorithm to arbitrary k-space trajectories. This PILS method can be further improved to provide truly parallel broadband imaging with the use of multiple-demodulation hardware. By customizing the demodulation based on each coil's location, the k-space sampling rate can be chosen based on each coil's localized sensitivity region along the readout direction. A simulated demodulation of data from 2D Fourier transform (FT) and spiral trajectories is shown to demonstrate the method's feasibility.

Algorithms↗

Rapid gridding reconstruction with a minimal oversampling ratio.

Reconstruction of magnetic resonance images from data not falling on a Cartesian grid is a Fourier inversion problem typically solved using convolution interpolation, also known as gridding. Gridding is simple and robust and has parameters, the grid oversampling ratio and the kernel width, that can be used to trade accuracy for computational memory and time reductions. We have found that significant reductions in computation memory and time can be obtained while maintaining high accuracy by using a minimal oversampling ratio, from 1.125 to 1.375, instead of the typically employed grid oversampling ratio of two. When using a minimal oversampling ratio, appropriate design of the convolution kernel is important for maintaining high accuracy. We derive a simple equation for choosing the optimal Kaiser-Bessel convolution kernel for a given oversampling ratio and kernel width. As well, we evaluate the effect of presampling the kernel, a common technique used to reduce the computation time, and find that using linear interpolation between samples adds negligible error with far less samples than is necessary with nearest-neighbor interpolation. We also develop a new method for choosing the optimal presampled kernel. Using a minimal oversampling ratio and presampled kernel, we are able to perform a three-dimensional (3-D) reconstruction in one-eighth the time and requiring one-third the computer memory versus using an oversampling ratio of two and a Kaiser-Bessel convolution kernel, while maintaining the same level of accuracy.

Algorithms↗

Time-optimal multidimensional gradient waveform design for rapid imaging.

Magnetic resonance imaging (MRI) is limited in many cases by long scan times and low spatial resolution. Recent advances in gradient systems hardware allow very rapid imaging sequences, such as steady-state free precession (SSFP), which has repetition times (TRs) of 2-5 ms. The design of these rapid sequences demands time-optimal preparatory gradient waveforms to provide maximum readout duty-cycle, and preserve spatial resolution and SNR while keeping TRs low. Time-optimal gradient waveforms can be synthesized analytically for certain simple cases. However, certain problems, such as time-optimal 2D and 3D gradient design with moment constraints, either may not have a solution or must be solved numerically. We show that time-optimal gradient design is a convex-optimization problem, for which very efficient solution methods exist. These methods can be applied to solve gradient design problems for oblique gradient design, spiral imaging, and flow-encoding using either a constant slew rate or the more exact voltage-limited gradient models. Ultimately, these methods provide a time-optimal solution to many 2D and 3D gradient design problems in a sufficiently short time for interactive imaging.

Magnetic Resonance Imaging↗

Analysis of multiple-acquisition SSFP.

Refocused steady-state free precession (SSFP) is limited by its high sensitivity to local field variation, particularly at high field strengths or the long repetition times (TRs) necessary for high resolution. Several methods have been proposed to reduce SSFP banding artifact by combining multiple phase-cycled SSFP acquisitions, each differing in how individual signal magnitudes and phases are combined. These include maximum-intensity SSFP (MI-SSFP) and complex-sum SSFP (CS-SSFP). The reduction in SSFP banding is accompanied by a loss in signal-to-noise ratio (SNR) efficiency. In this work a general framework for analyzing banding artifact reduction, contrast, and SNR of any multiple-acquisition SSFP combination method is presented. A new sum-of-squares method is proposed, and a comparison is performed between each of the combination schemes. The sum-of-squares SSFP technique (SOS-SSFP) delivers both robust banding artifact reduction and higher SNR efficiency than other multiple-acquisition techniques, while preserving SSFP contrast.

Artifacts↗

Variable-rate selective excitation for rapid MRI sequences.

Balanced steady-state free precession (SSFP) imaging sequences require short repetition times (TRs) to avoid off-resonance artifacts. The use of slab-selective excitations is common, as this can improve imaging speed by limiting the field of view (FOV). However, the necessarily short-duration excitations have poor slab profiles. This results in unusable slices at the slab edge due to significant flip-angle variations or aliasing in the slab direction. Variable-rate selective excitation (VERSE) is a technique by which a time-varying gradient waveform is combined with a modified RF waveform to provide the same excitation profile with different RF power and duration characteristics. With the use of VERSE, it is possible to design short-duration pulses with dramatically improved slab profiles. These pulses achieve high flip angles with only minor off-resonance sensitivity, while meeting SAR limits at 1.5 T. The improved slab profiles will enable more rapid 3D imaging of limited volumes, with more consistent image contrast across the excited slab.

Computer Simulation↗

Dynamic real-time architecture in magnetic resonance coronary angiography--a prospective clinical trial.

OBJECTIVES: A dynamic real-time (dRT) architecture has been developed to address limitations in magnetic resonance coronary angiography (MRCA). A prospective clinical trial of 45 patients suspected of coronary artery disease was conducted to determine clinical utility of this integrated real-time system. BACKGROUND: Clinical implementation of MRCA is not performed routinely today. However, improved anatomic coverage, image quality, and scan flexibility may enhance its clinical utility. A novel real-time architecture addresses these challenges through instantaneous reconfiguration between real-time (RT) and high-resolution (HR) imaging sequences with dynamic selection of the desired element on a custom-designed receiver coil. METHODS: A total of 45 subjects were recruited consecutively to evaluate scan time, anatomic coverage, image quality, and detection of coronary lesions. Using a modern PC, the dRT switches from RT to gated HR imaging sequence in one repetition time (39 ms). Magnetic resonance imaging (MRI) scanning was performed using a custom-designed coronary coil consisting of two four-inch phase-array circular elements enabled with real-time selection of the desired coil element. RESULTS: All studies were completed in less than 45 minutes and required a mean of 12 breath holds (16 heartbeats). Of the total number of coronary segments, 91% (357/394) were visualized. Excellent or good image quality was achieved in 86% of the segments. Blinded analysis of the coronary arteries revealed sensitivity of 93% and specificity of 88% in the detection of coronary stenoses. CONCLUSIONS: The integrated environment of dRT provides a rapid and flexible scan protocol for MRCA while achieving wide anatomical coverage, high image quality, and reliable detection of coronary stenosis in short scan time.

Adult↗