Time-optimal multidimensional gradient waveform design for rapid imaging.

Abstract

Magnetic resonance imaging (MRI) is limited in many cases by long scan times and low spatial resolution. Recent advances in gradient systems hardware allow very rapid imaging sequences, such as steady-state free precession (SSFP), which has repetition times (TRs) of 2-5 ms. The design of these rapid sequences demands time-optimal preparatory gradient waveforms to provide maximum readout duty-cycle, and preserve spatial resolution and SNR while keeping TRs low. Time-optimal gradient waveforms can be synthesized analytically for certain simple cases. However, certain problems, such as time-optimal 2D and 3D gradient design with moment constraints, either may not have a solution or must be solved numerically. We show that time-optimal gradient design is a convex-optimization problem, for which very efficient solution methods exist. These methods can be applied to solve gradient design problems for oblique gradient design, spiral imaging, and flow-encoding using either a constant slew rate or the more exact voltage-limited gradient models. Ultimately, these methods provide a time-optimal solution to many 2D and 3D gradient design problems in a sufficiently short time for interactive imaging.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Brian A Hargreaves, Dwight G Nishimura, Steven M Conolly. 2004. Time-optimal multidimensional gradient waveform design for rapid imaging.. https://doi.org/10.1002/mrm.10666

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Ultra-high-field 7T MRI reveals neural abnormalities of attention networks in relation to cognitive impairment in hypertension.

Hypertension is a significant risk factor for cognitive impairment (CI), yet the corresponding neural network abnormalities remain underexplored. In this study, we examined the associations among global and domain-specific cognitive dysfunction, neuroimaging measures, and blood pressure in a subgroup of hypertensive patients with CI (N = 41) from a randomized controlled trial who underwent ultra-high-field 7 T MRI. Structural atrophy related to CI was localized to regions overlapping the attention networks. Both whole-brain and within-network dysfunction of the attention networks were associated with worse global cognitive performance. Notably, hyperconnectivity within key attention network hubs, including the right anterior insula and posterior intraparietal sulcus, was associated with declined processing speed in hypertensive patients, mediating the association between pulse pressure and processing speed. These findings provide new insights into the neural pathophysiology of hypertension-related CI and suggest potential network-based targets for intervention.

Magnetic Resonance Imaging↗

Oscillating steady states.

The signal formation and properties of steady-state free precession (SSFP) in combination with alternating RF pulse phases or alternating spin precession is analyzed. Simulations and experiments demonstrate that the amplitudes of SSFP echo paths are significantly influenced by application of alternating phases either via the exciting RF pulse or via some external mechanism producing alternating spin precession. The influence of alternating phases on echo amplitudes is different for different echo paths. The primary SSFP echo paths F(0) (-) and F(0) (+) exhibit a signal reduction whereas higher-order echoes F(-1) (-) and F(1) (+) show a signal increase upon application of oscillating phases. This behavior can be described using a simple perturbation theory applied to the frequency response profile of balanced SSFP combined with a final signal integration over one balanced SSFP band. The high sensitivity of SSFP echo amplitudes to alternating RF pulse phases or precession is exemplarily used to detect and visualize propagating transverse acoustic shear waves. Detection of flow or alternating currents are further possibilities to apply this unique feature of SSFP.

Magnetic Resonance Imaging↗