PubMed Health⌕ Search

Biomedical subjects

E Cronin

Publications and source records attributed to E Cronin.

At least 19 recordsLinked to original sources

Contact sensitivity to lignocaine.

Lignocaine is a rare contact allergen, in contrast to other local anaesthetics such as benzocaine, which commonly sensitize. The case of a patient sensitized to lignocaine through the use of a topical medication for the treatment of haemorrhoids is reported. Previous reports show that application of a lignocaine-containing preparation for pruritus ani is the most frequent cause of sensitization to lignocaine. The significance of sensitization to lignocaine is discussed in the light of its widespread use both in local anaesthesia and as an anti-arrhythmic.

Administration, Topical↗

Patients with atopic eczema do become sensitized to contact allergens.

Sensitization to contact allergens in atopics was assessed by grouping 989 patients, who were routinely patch tested, by their personal atopic status. Sensitization to > or = 1 allergens occurred in 38% of the 191 patients with existing atopic eczema, in 53% of the 120 with a past history of atopic eczema, in 54% of the 156 with only mucous membrane atopy and in 50% of the 510 who were not atopic. Sensitization to perfume, a common environmental allergen, was similar in all 4 groups, as was nickel among women. Patients with atopic eczema should be patch tested.

Allergens↗

Sensitization in atopic and non-atopic hairdressers with hand eczema.

To investigate the capability of atopics to be sensitized to contact allergens, 143 hairdressers with hand eczema, who had been patch tested with the hairdresser's series, were studied. The 125 women and 18 men were grouped according to their personal atopic status. There were 45 eczematous atopics, 32 mucous membrane atopics and 66 non-atopics. Sensitization to at least one of the hairdressing chemicals was found in 60% of the eczematous atopics, 53% of the mucous membrane atopics and 58% of the non-atopics. The commonest sensitizer in each group was glyceryl monothioglycolate followed by para-phenylenediamine and related dyes. None of the 18 men were allergic to nickel but 40% of the women were thus sensitized. Jewelry rather than equipment was thought to be the cause. No significant difference was found between the eczematous atopics, mucous membrane atopics and non-atopics in their capacity to be sensitized to hairdressing allergens or to nickel.

Adolescent↗

Diagnosis of lichen planus pemphigoides in the absence of bullae on normal-appearing skin.

A case of lichen planus pemphigoides is described in which bullae and erosions affected the areas of lichen planus only. The diagnosis was confirmed by the finding of linear C3 and IgG deposition in the basement membrane zone (BMZ) of perilesional skin. Indirect immunofluorescence revealed circulating IgG anti-BMZ antibodies and a lamina lucida split was demonstrated by electron microscopy. This case challenges the clinical dogma that the occurrence of bullae on normal-appearing skin is essential for the diagnosis of lichen planus pemphigoides.

Humans↗

Recalcitrant pyoderma gangrenosum--two cases successfully treated with cyclosporin A.

The successful use of cyclosporin A (CSA) in organ transplantation is now well established. In recent years its usefulness has extended to the treatment of cutaneous autoimmune disorders, including pyoderma gangrenosum (P.G.). We report two further cases of recalcitrant P.G., both associated with rheumatoid arthritis (R.A.) which responded to low dose CSA.

Aged↗

Final diagnoses in patients referred for patch testing.

The final diagnoses made in 989 patients consecutively patch tested in 1990 have been reviewed. Among the men, their dermatitis was entirely occupational in 17.9% and partially so in 12.5%. Among the women, it was entirely occupational in 6.4% and partially so in 9.5%. In both groups, irritants exceeded allergens as the cause, whereas allergens superseded irritants in the patients with a non-occupational eczema caused or aggravated by external factors. It seems likely that domestic irritants were overlooked in patients with a non-occupational dermatitis.

Adult↗

Formaldehyde is a significant allergen in women with hand eczema.

Among patients consecutively patch tested at St John's from 1984-1989, the prevalence rate of formaldehyde sensitivity was 2.2% for men and 3.7% for women. During these 6 years, 117 women were primarily sensitized by formaldehyde, of whom 61 (52%) had hand eczema. Exposure was occupational in 12% and domestic in 88%. Cleaning products were the main source of exposure in the domestic group. 20 women with hand eczema avoided formaldehyde and their hands healed in 2, greatly improved in 11 and were better in 7.

Allergens↗

Immediate and delayed photocontact dermatitis from isopropyl dibenzoylmethane.

Immediate and delayed photocontact dermatitis from the UVA absorber isopropyl dibenzoylmethane is described in 1 patient. In a dose response study in a 2nd patient with delayed photocontact dermatitis, the minimal dose of UVA needed to elicit a positive photopatch to isopropyl dibenzoylmethane 2% was determined to be 2 J/cm2.

Adult↗

Lichen planus pemphigoides.

Lichen planus pemphigoides is a rare disease in which blistering occurs in association with lesions of classical lichen planus. We describe a patient with lichen planus pemphigoides and discuss the evidence for there being one disease rather than the coincidence of bullous pemphigoid and lichen planus.

Adult↗

Frequency of sensitisation to the preservative Kathon CG.

The incidences of sensitisation to Kathon CG are reported for patients routinely tested from 1984 to 1986 in Bari, London, Louvain, Nijmegen, Oulu and San Francisco. For these 3 years, the overall frequency of sensitisation varied for women from 3.3% in Oulu to 0.6% in London and San Francisco and for men from 1.4% in Oulu to 0% in San Francisco. Women were predominantly sensitised, probably by cosmetics, toiletries and domestic cleaners. Occupational sensitisation was much less frequent.

Cosmetics↗

Computing in clinical departments: implications for the design of hospital information systems.

Information technology is of increasing importance to the health service. Two main types of system have grown up, those in clinical departments and central administrative systems. It is important to consider their inter-relationships. A clinical system in the Renal Unit at Manchester Royal Infirmary is described, which is typical of many departmental systems. Further work is reported demonstrating an impressive commonality in the requirements of different clinical disciplines and supporting the view that departmental systems are a valuable source of accurate management data. The experience gained from designing departmental systems is reviewed. It is concluded that the participation of users is essential to the successful design and implementation of systems in the National Health Service and that departmental systems have a crucial role to play in the development of district information systems.

Computers↗