Comparison of atrial-His intervals in patients with and without dual atrioventricular nodal physiology and atrioventricular nodal reentrant tachycardia.

The purpose of this study was to compare the atrial-His intervals generated during programmed atrial stimulation in patients with and without dual atrioventricular nodal physiology and with and without inducible atrioventricular nodal reentrant tachycardia. Programmed atrial stimulation at a basic-drive cycle length of 500 to 600 msec was performed in 180 patients. The minimum atrial-His interval was defined as the atrial-His interval of the basic-drive beats. The maximum atrial-His interval was defined as the longest A2H2 interval. The criterion for dual atrioventricular nodal physiology was an increment of 50 msec in the A2H2 interval in association with a 10 msec decrement in the A1A2 interval. The minimum atrial-His interval was significantly shorter (106 +/- 34 msec vs 116 +/- 29 msec; p < 0.05) and the maximum atrial-His interval significantly longer (304 +/- 101 msec vs 222 +/- 56 msec; p < 0.001) in the 87 patients who had atrioventricular nodal reentry than in the 93 patients who did not. Among the 87 patients who had atrioventricular nodal reentry, the maximum atrial-His interval was significantly longer in 53 patients who had dual atrioventricular nodal physiology than in 34 patients who did not (340 +/- 105 msec vs 249 +/- 62 msec; p < 0.001). Among the 66 patients who had dual atrioventricular nodal physiology, the maximum atrial-His interval was significantly longer in 53 patients who had atrioventricular nodal reentry than in 13 patients who did not (340 +/- 105 msec vs 268 +/- 61 msec; p < 0.01). The insensitivity of the conventional dual atrioventricular nodal physiology criterion for the detection of dual atrioventricular nodal pathways is in part attributable to a lesser degree of slowing of conduction in the slow pathway relative to the fast pathway in some patients who have atrioventricular nodal reentry. The inability to demonstrate atrioventricular nodal reentry despite the presence of dual atrioventricular nodal physiology in some persons may be attributable in part to an inadequate degree of conduction delay in the slow pathway.

Atrioventricular Node↗

Comparison of the ages of tachycardia onset in patients with atrioventricular nodal reentrant tachycardia and accessory pathway-mediated tachycardia.

Atrioventricular nodal reentrant tachycardia and accessory pathway-mediated tachycardia may have different ages of tachycardia onset. Symptom onset data were obtained in 519 patients (atrioventricular nodal reentrant tachycardia, 231, accessory pathway-mediated tachycardia, 288). The mean age of the patients at the time of evaluation was 47 +/- 17 years (atrioventricular nodal reentrant tachycardia) and 37 +/- 15 years (accessory pathway-mediated tachycardia). The mean age of symptom onset was 32 +/- 18 years for atrioventricular nodal reentrant tachycardia and 23 +/- 14 years for accessory pathway-mediated tachycardia. A significantly greater proportion of patients with atrioventricular nodal reentrant tachycardia had the initial onset of symptoms after the age of 20 years (atrioventricular nodal reentrant tachycardia, 67% vs accessory pathway-mediated tachycardia, 41%, p < 0.001). In summary, there is a different mean age of symptom onset for patients with atrioventricular nodal reentrant tachycardia and accessory pathway-mediated tachycardia.

Adult↗

Use of isoproterenol during programmed ventricular stimulation in patients with coronary artery disease and nonsustained ventricular tachycardia.

Twenty-three consecutive patients (20 men and 3 women) with coronary artery disease and nonsustained ventricular tachycardia (VT) in whom sustained VT was not inducible in a baseline electrophysiology test underwent repeated testing during isoproterenol infusion to determine the inducibility of sustained monomorphic VT. After the baseline study, each patient received a 2 to 4 microgram/min infusion of isoproterenol (mean 2.5 +/- 0.8 microgram/min). The sinus cycle length shortened by a mean of 29% +/- 9% and programmed stimulation was repeated. Nineteen patients had no inducible sustained, monomorphic VT, two patients had only inducible nonsustained VT, and two patients had ventricular fibrillation. Patients were followed up for 10 to 20 months (mean 14.4 +/- 2.9 months) and had no syncope, sustained monomorphic VT, or sudden death. Isoproterenol infusion during programmed stimulation in patients with coronary heart disease and nonsustained VT does not facilitate the induction of sustained monomorphic VT.

Aged↗

Slow pathway ablation in patients with documented but noninducible paroxysmal supraventricular tachycardia.

OBJECTIVES: The purpose of this study was to assess the clinical efficacy of radiofrequency ablation of the slow pathway in patients with documented but noninducible paroxysmal supraventricular tachycardia (PSVT) who have evidence of dual atrioventricular (AV) node pathways. BACKGROUND: Patients with a documented history of PSVT at times do not have inducible PSVT in the electrophysiology laboratory. Because dual AV node pathways serve as the substrate for AV node reentrant tachycardia (AVNRT), ablation of the slow pathway potentially may be useful in these patients. METHODS: The subjects in this prospective study were seven consecutive patients who underwent an electrophysiologic procedure because of documented PSVT and were found to have dual AV node physiology or inducible single AV node echo beats, but no inducible PSVT despite the administration of isoproterenol and atropine. Their mean (+/- SD) age was 33 +/- 13 years, and they had been symptomatic for 12 +/- 12 years. The frequency of the episodes of PSVT ranged from > or = 1/day to 1/month. The rate of the documented episodes ranged from 170 to 260 beats/min, and discrete P waves were not apparent. Slow pathway ablation was performed with 9 +/- 4 applications of radiofrequency energy using a combined anatomic and electrogram mapping approach. RESULTS: All evidence of dual AV node pathways was eliminated in six patients, and dual AV node physiology remained present in one patient. During a mean follow-up period of 15 +/- 10 months (range 8 to 27), no patient had a recurrence of symptomatic tachycardia (success rate 95% confidence interval 65% to 100%). CONCLUSIONS: Slow pathway ablation may be clinically useful in patients with documented but noinducible PSVT who have evidence of dual AV node pathways.

Adult↗

Incidence of lead system malfunction detected during implantable defibrillator generator replacement.

Implantable cardioverter-defibrillator (ICD) generator replacement due to a depleted battery is a frequently performed procedure. The frequency with which sensing and defibrillation system failures are identified during device replacement procedures has not been previously described. Therefore, the purpose of this study was to prospectively determine the frequency of lead system malfunction detected at the time of device replacement in 55 consecutive patients undergoing ICD generator replacement. The mean age of the patients was 63 +/- 10 years and 40 of them were men. Forty-nine patients had an epicardial lead system, and six patients had a nonthoracotomy lead system. Four [7%] of these 55 patients were noted to have previously undetected lead system failure, either sensing (n = 3) or defibrillation (n = 1), necessitating system revision. The lead systems that failed were 40 +/- 6 months old (33-49 months). In summary, during ICD generator replacement, previously undetected problems with sensing or defibrillation may be identified in approximately 10% of patients. Therefore, a comprehensive evaluation of the sensing and the defibrillation functions should be an essential component of the ICD generator replacement procedure.

Defibrillators, Implantable↗

Randomized comparison of two techniques for titrating power during radiofrequency ablation of accessory pathways.

INTRODUCTION: The purpose of this study was to prospectively compare the value of impedance and temperature monitoring during accessory pathway ablation. Temperature and impedance monitoring can be used during radiofrequency ablation of accessory pathways to titrate power to achieve adequate but not excessive tissue heating. METHODS AND RESULTS: One hundred thirty-two patients with a single accessory pathway were randomly assigned to undergo ablation using either impedance monitoring or temperature monitoring. During impedance monitoring, the endpoint for titration of power was a 5- to 10-omega decrease in the measured impedance while for temperature monitoring the endpoint was to achieve a temperature of 58 degrees to 62 degrees C. Two protocols were used. In protocol 1 (90 patients), impedance monitoring was performed with a nonthermistor catheter and temperature monitoring was performed with a thermistor catheter. In protocol 2 (42 patients), a thermistor catheter was used in all patients. In protocol 1, the success rate (93% vs 93%; P = 1.0), ablation procedure duration (57 +/- 56 vs 41 +/- 41 min), fluoroscopy time (48 +/- 29 vs 41 +/- 23 min; P = 0.3), number of applications (6.2 +/- 4.7 vs 5.7 +/- 4.6; P = 0.8), and the number of applications associated with coagulum formation (0.1 +/- 0.3 vs 0.3 +/- 0.6; P = 0.1) were similar in the two groups. In protocol 2, as in protocol 1, there were no differences in the success rate (91% vs 95%; P = 1.0), ablation procedure duration (49 +/- 37 vs 62 +/- 55 min; P = 0.4), fluoroscopy time (46 +/- 24 vs 49 +/- 36 min; P = 0.8), number of applications (6.8 +/- 7.0 vs 7.8 +/- 12.1; P = 0.7), or number of applications associated with coagulum formation (0.3 +/- 0.6 vs 0.2 +/- 0.7; P = 0.6), between the impedance and temperature monitoring groups. CONCLUSION: Temperature and impedance monitoring are equally effective in optimizing the results of accessory pathway ablation.

Adult↗

Atrial electrogram characteristics in patients with and without atrioventricular nodal reentrant tachycardia.

BACKGROUND: Multicomponent atrial electrograms and "slow pathway potentials" are helpful in identifying target sites for radiofrequency catheter ablation of the slow pathway in patients with atrioventricular (AV) nodal reentrant tachycardia. The purpose of this study was to compare the atrial electrograms recorded at various locations in the right atrium in patients with and without AV nodal reentrant tachycardia to assess the specificity of multicomponent atrial electrograms and possible slow pathway potentials both for the posteroseptal right atrium and for patients with AV nodal reentrant tachycardia. METHODS AND RESULTS: In 25 patients with AV nodal reentrant tachycardia and 23 control patients without AV nodal reentrant tachycardia or dual AV nodal physiology, atrial electrograms with an AV ratio of < or = 1:2 were recorded at the posteroseptal right atrium near the coronary sinus ostium and in the right atrium near the posterior, lateral, and anterior aspects of the tricuspid annulus. Attempts were made to identify broad, multicomponent, and double atrial electrograms. There were no significant differences between the patients with and without AV nodal reentrant tachycardia in the mean number of deflections in the atrial electrograms or in the mean duration of the atrial electrograms recorded at any of the atrial sites. In all patients, the number of atrial electrogram deflections and the atrial electrogram duration were significantly greater at the posteroseptal position than at the other three atrial sites. The prevalence of potentials with the appearance of slow pathway potentials in the posterior septum was similar in patients with and without AV nodal reentrant tachycardia (68% and 70%, respectively). The prevalence of these potentials was 6% to 25% at the other three atrial sites (P < .005 compared with the posterior septum). CONCLUSIONS: The atrial electrogram characteristics that have been found to be useful in identifying effective posteroseptal slow pathway ablation sites in patients with AV nodal reentrant tachycardia are equally prevalent in patients without AV nodal reentrant tachycardia or dual AV nodal physiology. Atrial electrograms in the posteroseptal area are broader and contain more deflections than at other areas in the right atrium, possibly because of conduction properties of the posterior transitional zone that are independent of the presence of AV nodal reentrant tachycardia.

Adult↗

Comparison of implantation of nonthoracotomy defibrillators in the operating room versus the electrophysiology laboratory.

Implantable cardioverter-defibrillators (ICDs) with nonthoracotomy lead systems are widely available, and are implanted either in the electrophysiology laboratory or the operating room. The purpose of this study was to prospectively evaluate the safety and efficacy of nonthoracotomy ICD implantation in an electrophysiology laboratory versus an operating room. During a 7-month period, 62 consecutive ICDs with nonthoracotomy lead systems were implanted in patients in an electrophysiology laboratory. During the next 10 months, 110 consecutive ICDs were implanted in patients in a surgical operating room. All ICD implantations were performed under general anesthesia by electrophysiologists. There were no differences in age (58 +/- 14 vs 62 +/- 12 years, p = 0.06), gender distribution (p = 0.3), frequency of structural heart disease (97% vs 97%, p = 0.9), ejection fraction (0.31 +/- 0.15 vs 0.29 +/- 0.13, p = 0.3), or presentation with cardiac arrest (65% vs 53%, p = 0.2) between patients undergoing ICD implantation in the electrophysiology laboratory and operating room, respectively. The rate of successful implantation and of complications for systems implanted in the electrophysiology laboratory (95% and 13%, respectively) and in the operating room (98% and 14%, respectively) were similar (p = 0.4 and p = 0.8, respectively). Specifically, the rate of infection (0% vs 4%, p = 0.3) and hematoma formation (2% vs 4%, p = 0.8) were not statistically significantly different. Three patients who had undergone ICD implantation in an operating room died within 30 days. ICDs with nonthoracotomy lead systems can be implanted with a similarly high rate of success and acceptable complication rate in the electrophysiology laboratory and in the operating room.

Adult↗

Relation between impedance and temperature during radiofrequency ablation of accessory pathways.

Temperature monitoring is a useful tool for radiofrequency ablation of accessory pathways. Impedance monitoring is also helpful, and an impedance fall of 20 ohm may predict coagulum formation. Therefore the purpose of this study was to prospectively quantitate the correlation between impedance and temperature during radiofrequency ablation. Thirty-three consecutive patients underwent radiofrequency ablation with a thermistor ablation catheter with continuous temperature and impedance monitoring during each energy application. The initial and final impedance and temperature measurements for 319 applications of radiofrequency energy were 109 +/- 17 ohm and 102 +/- 17 ohm (p < 0.0001), respectively, and 37 +/- 1 degree C and 57 degrees +/- 11 degrees C (p < 0.0001), respectively. Among the 319 applications of radiofrequency energy, 158 were associated with > or = 20 degrees C increase in tissue temperature, and 10 were associated with coagulum formation. A > or = 20 degrees C increase in tissue temperature was observed in 84 of 104 applications associated with a 5 to 10 ohm decrease in impedance (81% positive predictive value and 93% negative predictive value). The mean change in impedance for applications associated with and without coagulum formation was -19 +/- 7 ohm and -6 +/- 6 ohm (p < 0.0001), respectively, and coagulum formation never occurred with less than a 12 ohm decrease. In conclusions successful tissue heating without coagulum formation can be achieved by titrating the power to achieve a 5 to 10 ohm decrement in impedance. Impedance decrements beyond 10 ohm increase the likelihood of coagulum formation.

Adult↗

Effect of first-phase polarity of biphasic shocks on defibrillation threshold with a single transvenous lead system.

OBJECTIVES: The purpose of this study was to determine whether the polarity of the first phase of a biphasic shock affects the defibrillation threshold. BACKGROUND: The polarity of a monophasic shock has been shown to affect the defibrillation threshold. METHODS: A transvenous defibrillation lead with distal and proximal shocking electrodes was used in this study. In 15 consecutive patients, the defibrillation threshold was determined twice using a step-down protocol, in random order: with the distal coil as the anode for the initial phase (anodal biphasic shock) and with the polarity reversed (cathodal biphasic shock). The power to detect a 5.0-J difference in this study is 0.96. These patients were 61 +/- 11 years old (mean +/- SD), and the mean left ventricular ejection fraction was 0.32 +/- 0.10. RESULTS: Mean defibrillation threshold using anodal biphasic shocks was 9.9 +/- 4.8 J, compared with 9.5 +/- 4.2 J using cathodal biphasic shocks (p = 0.8). In three patients the defibrillation threshold was lower by a mean of 6.3 +/- 2.9 J with the former configuration; in three patients the defibrillation threshold was lower by a mean of 6.7 +/- 2.5 J with the latter configuration; and in nine patients it was the same. Using the standard cathodal configuration, a defibrillation threshold < or = 10 J was obtained in approximately 70% of patients, and a subcutaneous patch was not required in any patient. CONCLUSIONS: The polarity of the first phase of a biphasic shock used with a single transvenous lead does not affect the defibrillation threshold.

Defibrillators, Implantable↗

Catheter ablation of ventricular tachycardia.

Endocardial lesions created by radiofrequency catheter ablation are relatively small and focal. The application of radiofrequency ablation to patients with structural heart disease and ventricular tachycardia is quite limited because the substrate for these tachycardias is often diffuse or difficult to localize. In contrast, idiopathic ventricular tachycardia often originates from a discrete focus and can usually be ablated using radiofrequency energy. The wider applicability of ablation therapy for ventricular tachycardia will depend on improvements in mapping techniques and the ability to create larger areas of injury in patients with coronary artery disease and ventricular tachycardia.

Atrioventricular Node↗

Radiofrequency ablation of idiopathic left anterior fascicular tachycardia.

INTRODUCTION: A 45-year-old man with idiopathic ventricular tachycardia (VT) having a right bundle branch block configuration with right-axis deviation underwent an electrophysiologic test. METHODS AND RESULTS: Mapping demonstrated a site on the anterobasal wall of the left ventricle where there was an excellent pace map and an endocardial activation time of -20 msec, but radiofrequency catheter ablation at this site was unsuccessful. At a nearby site, a presumed Purkinje potential preceded the by 30 msec during VT and sinus rhythm, and catheter ablation was effective despite a poor pace map and an endocardial ventricular activation time of zero. CONCLUSION: Idiopathic VT with a right bundle branch configuration and right-axis deviation may originate in the area of the left anterior fascicle. A potential presumed to represent a Purkinje potential may be more helpful than endocardial ventricular activation mapping or pace mapping in guiding ablation of this type of VT.

Catheter Ablation↗

Assessment of pacing maneuvers used to validate anterograde accessory pathway potentials.

Four pacing maneuvers have been proposed to validate an anterograde accessory pathway potential (APP): (1) atrial pacing to induce complete block between the atrial electrogram and the APP; (2) ventricular pacing to advance the APP without altering the timing of the atrial electrogram; (3) atrial pacing to induce complete block between the APP and the ventricular electrogram; and (4) ventricular pacing to advance the ventricular electrogram without altering the timing of the APP. The purpose of this study was to assess these validation techniques by applying them to electrograms that simulated APPs but which were known to be atrial in origin. In 32 patients undergoing an electrophysiology procedure, a split atrial electrogram containing two components separated by at least 30 msec (mean 54 +/- 15 msec) was recorded. Using an atrial extrastimulus technique, complete block between the two components of the atrial electrogram (criterion 1) could never be induced, but complete block between the second component of the atrial electrogram and the ventricular electrogram (criterion 3) consistently was induced. Using a ventricular extrastimulus technique, the second component of the atrial electrogram consistently could be advanced by 10 to 40 msec without altering the timing of the first component (criterion 2). In addition, with ventricular pacing, the ventricular electrogram consistently was advanced without altering the timing of the two components of the atrial electrogram (criterion 4). In conclusion, among the four pacing maneuvers used to validate an anterograde APP, the only one that may be specific for an APP is the ability to induce complete block between the atrial electrogram and the APP.

Adult↗

A quantitative fluoroscopic comparison of the coronary sinus ostium in patients with and without AV nodal reentrant tachycardia.

INTRODUCTION: The purpose of this study was to perform a quantitative fluoroscopic analysis of the coronary sinus ostium and its relationship to the His bundle in patients with and without AV nodal reentrant tachycardia. Sites of slow pathway ablation are often near the coronary sinus ostium, which can be located within a few millimeters of the His bundle. Whether such close proximity of the coronary sinus ostium to the His bundle is unique to patients with AV nodal reentrant tachycardia is unknown. METHODS AND RESULTS: Fifty consecutive patients (mean age 39 +/- 14 years) with no structural heart disease underwent electrophysiologic testing and radiofrequency ablation. The study group consisted of 28 patients with inducible AV nodal reentrant tachycardia or dual AV nodal physiology and 22 patients in the control group. A coronary sinus venogram was performed in each patient. The coronary sinus ostium was similar in size in the study group (11.4 +/- 4.5 mm) and in the control group (10.5 +/- 3.6 mm, P = 0.2). The coronary sinus ostium was funnel shaped in half of the study patients and in half of the control patients (P = 1.0). The mean distance from the upper lip of the coronary sinus ostium to the tip of the His bundle catheter was 9.7 +/- 5.5 mm in the study group and 10.4 +/- 5.1 mm in the control group (P = 0.7). The mean distance from the lower lip of the coronary sinus ostium to the tip of the His-bundle catheter in the study group was 20.1 +/- 6.1 mm and 19.5 +/- 5.6 mm in the control group (P = 0.7). CONCLUSION: This study demonstrates a wide range of normal coronary sinus ostium diameters, morphology, and anatomic relationships with surrounding structures, with no demonstrable correlation to the presence or absence of dual AV node physiology or AV nodal reentrant tachycardia.

Adolescent↗

Comparison of atrial-His intervals during tachycardia and atrial pacing in patients with long RP tachycardia.

INTRODUCTION: The purpose of this study is to describe a simple and reliable diagnostic maneuver that allows for the rapid differentiation of atypical AV nodal reentrant tachycardia (AVNRT) from other causes of long RP tachycardia. Long RP tachycardias may be caused by atypical AVNRT, orthodromic reciprocating tachycardia (ORT) involving a slowly conducting retrograde accessory pathway, or atrial tachycardia. The differentiation of atypical AVNRT from ORT or atrial tachycardia may be difficult, especially when the differential diagnosis includes a posteroseptal accessory pathway or an atrial tachycardia arising in the posteroseptal right atrium. METHODS AND RESULTS: Twelve patients with atypical AVNRT, 21 with ORT, and 12 with an atrial tachycardia diagnosed using conventional criteria were enrolled in this study. The atrial-His (AH) interval was measured at the His-bundle position during the tachycardia and during atrial pacing from the high right atrium at the tachycardia cycle length in the setting of sinus rhythm. In patients with atypical AVNRT, the mean AH interval was 69 69 msec +/- 50 msec (+/- SD) longer during high right atrial pacing than during the tachycardia (P < 0.001). In 10 of 12 patients with atypical AVNRT, the AH interval during atrial pacing was more than 40 msec longer than the AH interval measured during the tachycardia. In contrast, in patients with ORT or atrial tachycardia, the differences in AH interval between atrial pacing and tachycardia were never more than 20 and 10 msec, respectively. CONCLUSION: The difference in the AH interval between atrial pacing and the tachycardia allows a simple and rapid means of differentiating atypical AVNRT from other types of long RP tachycardias.

Adult↗

Electrophysiologic effects of sotalol and amiodarone in patients with sustained monomorphic ventricular tachycardia.

No prospective studies have compared sotalol and amiodarone during electropharmacologic testing. The purpose of this prospective, randomized study was to compare the electrophysiologic effects of sotalol and amiodarone in patients with coronary artery disease and sustained monomorphic ventricular tachycardia (VT). Patients with coronary artery disease and sustained monomorphic VT inducible by programmed stimulation were randomly assigned to receive either sotalol (n = 17) or amiodarone (n = 17). The sotalol dose was titrated to 240 mg twice daily over 7 days. Amiodarone dosing consisted of 600 mg 3 times daily for 10 days. An electrophysiologic test was performed in the baseline state and at the end of the loading regimen. An adequate response was defined as the inability to induce VT or the ability to induce only relatively slow hemodynamically stable VT. During the follow-up electrophysiologic test, 24% of patients taking sotalol and 41% of those taking amiodarone had an adequate response to therapy (p = 0.30). Amiodarone lengthened the mean VT cycle length to a greater degree than sotalol (28% vs 12%, p < 0.01). There were no significant differences in the effects of sotalol and amiodarone on the ventricular effective refractory period. In patients with coronary artery disease, amiodarone and sotalol are similar in efficacy in the treatment of VT as assessed by electropharmacologic testing. The effects of the 2 drugs on ventricular refractoriness are similar, but amiodarone slows VT to a greater extent than sotalol.

Aged↗