Radiofrequency catheter modification of atrioventricular conduction to control the ventricular rate during atrial fibrillation.

BACKGROUND: In some patients with atrial fibrillation, the ventricular rate may be difficult to control with medications. We evaluated a radiofrequency catheter technique to modify atrioventricular conduction in atrial fibrillation in order to control the ventricular rate without creating pathologic atrioventricular block. METHODS: We studied 19 consecutive patients with atrial fibrillation and uncontrolled ventricular rates refractory to drug therapy. They had had atrial fibrillation for a mean (+/- SD) of 5.5 +/- 4.9 years, had had 4.9 +/- 0.9 unsuccessful drug trials, and were 62 +/- 15 years old. Before the procedure, the maximal ventricular rate during exercise was 180 +/- 39 beats per minute. A total of 11 +/- 5 radiofrequency-energy applications were delivered to the posterior septal or midseptal right atrium, near the ostium of the coronary sinus. RESULTS: Successful control of the ventricular rate without pathologic atrioventricular block was achieved in 14 of the 19 patients (74 percent). Persistent third-degree atrioventricular block requiring a permanent pacemaker occurred inadvertently in four patients (21 percent). Atrioventricular conduction was intentionally ablated in one patient. The 14 patients who had successful modification of conduction had persistent reductions in maximal ventricular rate during exercise (rate at three months, 126 +/- 24 beats per minute; P < 0.01). These patients had resolution of symptoms related to rapid rates during 8 +/- 2 months of follow-up. One patient had a recurrence of a rapid ventricular rate but was again asymptomatic after a second modification procedure. One patient with dilated cardiomyopathy died suddenly, five months after a successful procedure. CONCLUSIONS: A catheter technique to modify atrioventricular conduction without creating pathologic atrioventricular block is feasible in the majority of patients with symptomatic atrial fibrillation and a rapid ventricular rate refractory to drug therapy.

Adult↗

Effect of shock polarity on ventricular defibrillation threshold using a transvenous lead system.

OBJECTIVES: The purpose of this study was to determine whether the polarity of a monophasic shock used with a transvenous lead system affects the defibrillation threshold. BACKGROUND: The ability to implant an automatic defibrillator depends on achieving an adequate defibrillation threshold. METHODS: A transvenous defibrillation lead with distal and proximal shocking electrodes was used in this study. In 29 consecutive patients, the defibrillation threshold, using a stepdown protocol was determined twice in random order: 1) with the distal coil as the anode, and 2) with the polarity reversed. Only the 20 patients in whom an adequate defibrillation threshold could be obtained with the transvenous lead alone were included in this study. These patients were 61 +/- 14 years old (mean +/- SD) and had a mean ejection fraction of 28 +/- 12%. RESULTS: The mean defibrillation threshold was 11.5 +/- 5.0 J with the distal coil as the anode versus 16.9 +/- 7.7 J with the distal coil as the cathode (p = 0.04). The defibrillation threshold was lower by a mean of 9 +/- 7 J with the former configuration in 14 patients and was lower by a mean of 7 +/- 6 J with the latter configuration in 3 patients; in 3 patients it was the same with both configurations. Use of a subcutaneous patch was avoided in five patients by utilizing the distal electrode as the anode. CONCLUSIONS: Defibrillation thresholds with monophasic shocks are approximately 30% lower with the distal electrode as the anode. The use of anodal shocks may obviate the need for a subcutaneous patch and allow more frequent implantation of a transvenous lead system.

Adult↗

The economic impact of transvenous defibrillation lead systems.

The purpose of this study was to compare implant charges and convalescence for transvenous and epicardial defibrillation systems. Hospital stay, intensive care utilization, professional fees, and hospital bills were compared in 44 patients who underwent implantation of a cardiac defibrillator between September 1991 and May 1993. Twenty-five consecutive patients received an epicardial lead system, while 19 consecutive patients underwent implantation of the entire transvenous defibrillation system in the electrophysiology laboratory. There were no significant differences between the two groups in mean age or left ventricular ejection fraction. There was a significant reduction in postoperative hospital convalescence from 7.2 +/- 2.0 days with epicardial systems to 3.1 +/- 1.5 days with transvenous systems (P < 0.001). Postoperative intensive care unit stay was significantly reduced with transvenous systems compared with epicardial systems (0.1 +/- 0.2 vs 1.5 +/- 0.9 days; P < 0.001). Hospital charges were also significantly reduced with the transvenous lead system implants. Mean implant charges were lower with transvenous systems: $32,090 +/- $2,620 vs $38,307 +/- $2,701 (P < 0.001); convalescence charges were lower: $5,861 +/- $5,010 $12,447 +/- $4,969 (P < 0.001); the total hospital bill was also significantly lower with transvenous systems: $53,459 +/- $12,588 vs $71,981 +/- $16,172 (P < 0.001). Professional fees for implantation ($4,131 +/- $1,724 vs $6,100 +/- 0, P < 0.001), convalescence care ($1,258 +/- $960 vs $2,846 +/- $1,770; P < 0.001), and total professional fees ($12,925 +/- $4,772 vs $15,731 +/- $4,055, P < 0.05) were lower in the transvenous defibrillation group.(ABSTRACT TRUNCATED AT 250 WORDS)

Convalescence↗

Effects of partial and complete ablation of the slow pathway on fast pathway properties in patients with atrioventricular nodal reentrant tachycardia.

INTRODUCTION: The purpose of this study was to prospectively compare the effects of complete and partial ablation of slow pathway function on the fast pathway effective refractory period (ERP). METHODS AND RESULTS: The subjects were 20 patients (mean age 43 +/- 13 years) with atrioventricular nodal reentrant tachycardia (AVNRT), no structural heart disease, and easily inducible AVNRT. Autonomic blockade was achieved with propranolol (0.2 mg/kg) and atropine (0.04 mg/kg). After elimination of AVNRT and during autonomic blockade, the presence of residual slow pathway function was determined by the presence of a single AV nodal echo and/or dual AV nodal physiology. After autonomic blockade and before ablation, the mean fast pathway ERP was 319 +/- 44 msec and the mean slow pathway ERP was 251 +/- 31 msec. After slow pathway ablation and during autonomic blockade, 7 patients had residual slow pathway function and 13 did not. Complete loss of slow pathway function was associated with a shortening of the fast pathway ERP from 334 +/- 35 msec to 300 +/- 62 msec (P < 0.01), while the fast pathway ERP did not change significantly in patients with residual slow pathway function (291 +/- 29 msec vs 303 +/- 38 msec, respectively; P = 0.08). A shortening of 30 msec or more in the fast pathway ERP was observed in 11 of 13 patients who did not have residual slow pathway function, compared to 0 of 7 patients with residual slow pathway function (P < 0.001). CONCLUSION: Shortening of the fast pathway ERP after successful ablation of AVNRT is dependent upon complete loss of slow pathway function. This observation is consistent with electrotonic inhibition of the fast pathway by the slow pathway.

Adult↗

Implantation by electrophysiologists of 100 consecutive cardioverter defibrillators with nonthoracotomy lead systems.

BACKGROUND: Traditional lead systems for implantable cardioverter defibrillators (ICDs) require a thoracotomy for placement. Nonthoracotomy lead systems are available and are usually implanted by an electrophysiologist and a surgeon. The purpose of this study was to prospectively evaluate the safety and efficacy of ICD implantation with a nonthoracotomy lead system by electrophysiologists. METHODS AND RESULTS: A consecutive series of 100 patients (mean age, 61 +/- 13 years, +/- SD) underwent ICD implantation with a nonthoracotomy lead system while intubated and under general anesthesia. Seventy-seven patients had coronary artery disease, 15 had idiopathic cardiomyopathy, 6 had miscellaneous heart disease, and 2 had structurally normal hearts. The mean ejection fraction was 0.29 +/- 0.13. Sixty-eight patients had suffered a cardiac arrest, and 32 had had ventricular tachycardia or syncope. All patients except 9 underwent electrophysiological testing and had failed 1 +/- 1 drug trials before ICD implantation. Three types of nonthoracotomy lead systems were used. The nonthoracotomy lead with an ICD was successfully implanted in 96 patients (96%). Of the unsuccessful implants, 1 patient did not have venous access, the passive fixation lead in 1 would not remain lodged, 1 had elevated defibrillation thresholds, and 1 developed a hemopneumothorax while venous access was being obtained. The mean defibrillation threshold was 17 +/- 6 J. The mean procedure duration was 161 +/- 57 minutes. When a subcutaneous patch was used (n = 58), the procedure duration was 189 +/- 5 minutes, and when a subcutaneous patch was not required (n = 40), the procedure lasted 123 +/- 37 minutes (P < .0001). Patients remained in the hospital 4.5 +/- 4.1 days after implantation, with no procedure-related deaths. Acute complications occurred in 10 patients; 2 had lead dislodgments, 1 with previous abdominal surgery had his abdominal cavity entered (without other complications) while the ICD pocket was being made, 1 had postoperative heart failure, 1 developed a large hematoma when anticoagulation therapy was initiated, 3 required reintubation because of excessive anesthesia, 1 developed superficial cellulitis, and 1 developed a hemopneumothorax secondary to a lacerated subclavian vein. During 6 +/- 3 months of follow-up, 2 patients developed lead fractures. CONCLUSIONS: (1) Electrophysiologists can implant an ICD with a nonthoracotomy lead system safely and with a high success rate; (2) use of a subcutaneous patch correlates with longer procedure durations; and (3) special precautions should be taken in patients with previous abdominal surgery.

Anesthesia, General↗

Analysis of junctional ectopy during radiofrequency ablation of the slow pathway in patients with atrioventricular nodal reentrant tachycardia.

BACKGROUND: Junctional ectopy may occur during radiofrequency (RF) catheter ablation of the slow pathway in patients with atrioventricular nodal reentrant tachycardia (AVNRT). The purpose of the present study was to characterize this junctional ectopy quantitatively. METHODS AND RESULTS: The subjects of this study were 52 consecutive patients with AVNRT who underwent slow pathway ablation and 5 additional patients included retrospectively because they had developed high-degree atrioventricular (AV) block during the procedure. A combined anatomic and electrogram mapping approach was used for slow pathway ablation, and AVNRT was successfully eliminated in all patients. In the group of 52 consecutive patients, the incidence of junctional ectopy was significantly higher during 52 effective applications of RF energy than during 366 ineffective applications (100% versus 65%, P < .001). Compared with ineffective RF energy applications, successful RF energy applications had a significantly longer duration of individual bursts of junctional ectopy (7.1 +/- 7.1 versus 5.0 +/- 7.0 seconds [+/- SD], P < .05), a greater total number of junctional beats during the applications (24 +/- 16 versus 15 +/- 8, P < .01), and a greater total span of time during which junctional ectopy occurred (19 +/- 15 versus 11 +/- 12 seconds, P < .01). Four of the 52 patients plus an additional 5 patients developed transient AV block lasting 34 +/- 37 seconds. In 1 of the 9 patients who had transient AV block, third-degree AV nodal block requiring a permanent pacemaker recurred 2 weeks later. In each of the 9 patients who developed AV block, there was ventriculoatrial (VA) block in association with junctional ectopy during the RF energy application immediately preceding the AV block. Among 48 patients who did not develop AV block, 17 patients had at least one episode of VA block during junctional ectopy. The positive predictive value of VA block during junctional ectopy for the development of AV block was 19% in the consecutive series of 52 patients. Among 31 patients who always had 1:1 VA conduction in association with junctional ectopy, 12 had poor VA conduction in the baseline state, with a VA block cycle length of at least 500 milliseconds during ventricular pacing. CONCLUSIONS: In patients with AVNRT undergoing slow pathway ablation, junctional ectopy during the application of RF energy is a sensitive but nonspecific marker of successful ablation. The bursts of junctional ectopy are significantly longer at effective target sites than at ineffective sites. VA conduction should be expected during the junctional ectopy that accompanies slow pathway ablation, even when there is poor VA conduction during baseline ventricular pacing. VA block during junctional ectopy is a harbinger of AV block in patients undergoing RF ablation of the slow pathway. If energy applications are discontinued as soon as VA block occurs, the risk of AV block may be markedly reduced.

Adolescent↗

Results and efficiency of programmed ventricular stimulation with four extrastimuli compared with one, two, and three extrastimuli.

BACKGROUND: Conventional programmed ventricular stimulation protocols are inefficient compared with more recently proposed protocols. The purpose of the present study was to determine if additional efficiency could be derived from a 6-step programmed ventricular stimulation protocol that exclusively uses four extrastimuli. METHODS AND RESULTS: The subjects were 209 consecutive patients with coronary artery disease and documented sustained monomorphic ventricular tachycardia, nonsustained ventricular tachycardia, aborted sudden death, or syncope. These patients underwent 159 electrophysiological tests in the absence of antiarrhythmic drug therapy and 105 electrophysiological tests in the presence of antiarrhythmic therapy. Programmed stimulation was performed with two protocols in random order in each patient. Both protocols used an eight-beat drive train, 4-s intertrain pause, and basic drive cycle lengths of 350, 400, and 600 ms. The 6-step protocol started with coupling intervals of 290, 280, 270, and 260 ms, which were shortened simultaneously in 10-ms steps until S2 was refractory. The 18-step protocol used one, two and three extrastimuli in conventional sequential fashion. The end points were 30 s of sustained monomorphic ventricular tachycardia, two episodes of polymorphic ventricular tachycardia requiring cardioversion, or completion of the protocol at two right ventricular sites. There was no significant difference in the yield of sustained monomorphic ventricular tachycardia using the two protocols, regardless of the clinical presentation or treatment with antiarrhythmic drugs. Polymorphic ventricular tachycardia occurred with the 18-step protocol twice as frequently as with the 6-step protocol (6% versus 3%, P < .001). The duration of the 18-step protocol was significantly longer than that of the 6-step protocol in patients with inducible ventricular tachycardia (5.5 +/- 7 versus 2.3 +/- 2 minutes, P < .001), as well as in patients without inducible ventricular tachycardia (25.4 +/- 7 versus 6.9 +/- 2 minutes, P < .001). CONCLUSION: A stimulation protocol that exclusively uses four extrastimuli improves the specificity and efficiency of programmed ventricular stimulation without compromising the yield of monomorphic ventricular tachycardia in patients with coronary artery disease.

Aged↗

CA-125 concentrations in malignant and nonmalignant disease.

CA-125 is a high-molecular-mass glycoprotein expressed on the cell surface of some derivatives of embryonic coelomic epithelium. This tumor-associated antigen widely used to monitor ovarian carcinomas has been suggested as a promising noninvasive test that could differentiate benign from malignant conditions. Based on results of various studies, CA-125 measurement appears to be very useful in monitoring the response to therapy of ovarian carcinoma and for detecting tumor recurrence as exemplified in Case 1. However, because of the high frequency of false-positive results associated with many benign conditions, CA-125 is of little value as a screening test for ovarian carcinoma. A brief list of the most common benign conditions associated with CA-125 increase includes menstruation, pregnancy, benign pelvic tumors, pelvic inflammatory diseases, ovarian hyperstimulation syndrome, peritonitis, and many diseases leading to pleural effusion or ascites. According to several studies, a marked increase in CA-125 of greater than 1000 units/mL, as seen in Case 2, and even up to 5000 units/mL, could be seen in some benign conditions. This finding further limits the value of CA-125 as a potential noninvasive procedure to differentiate benign from malignant diseases. Although values up to 10,000 units/mL are occasionally seen in patients with ovarian carcinoma, we are reluctant to state that any concentration of CA-125 can be clearly diagnostic of malignancy.

Adult↗

Isolation and characterization of an anticoagulant proteinase, cerastase F-4, from Cerastes cerastes (Egyptian sand viper) venom.

An anticoagulant protease, Cerastase F-4, was isolated from the venom of Cerastes cerastes (Egyptian sand viper) by a combination of gel filtration, ion-exchange chromatography, and HPLC. Homogeneity of the purified anticoagulant was established by discontinuous polyacrylamide disc gel electrophoresis and by isotachophoresis. The anticoagulant enzyme is a single polypeptide chain without subunits having a molecular weight of 22,500. It consists of 28% aspartic acid residues and only 7% are basic amino acids. This agrees well with the fact that the anticoagulant is an acidic protein with an isoelectric point of 5.2. The anticoagulant is a proteolytic enzyme which hydrolyzes casein, fibrinogen and fibrin. The enzyme's optimum activity occurs around 55 degrees C. The anticoagulant showed no phospholipase A activity, low lethal activity, low hemorrhagic and capillary permeability activity, and no myotoxic activity.

Amino Acids↗

Mechanism of the anticoagulant, Cerastase F-4, isolated from Cerastes cerastes (Egyptian sand viper) venom.

An anticoagulant enzyme, Cerastase F-4, from the venom of Cerastes cerastes was purified to homogeneity and was characterized (1). In the present report the mode of its fibrinogenolytic and fibrinolytic actions, and its effects on some other blood coagulation factors are described. Cerastes F-4 was shown to readily hydrolyze the alpha A chain of fibrinogen followed by the hydrolysis of the beta B chain. The gamma-chain was relatively resistant to hydrolysis. It also degrades the three chains of fibrin at different rates. The degradation products of the two substrates shown on SDS-polyacrylamide gel were quite different from those produced by plasmin, indicating different sites of cleavage by the enzyme. Using specific chromogenic substrates, Cerastase F-4 seems not to show thrombin-like, plasmin-like, kallikrein-like, antithrombin, or antiplasmin actions. Also, it does not activate prothrombin or plasminogen but degrades both of them slowly. It is concluded that the anticoagulation property of the purified enzyme, Cerastase F-4, is due to its destruction of fibrinogen.

Blood Coagulation↗