Relatively low proportion of dystrophin gene deletions in Israeli Duchenne and Becker muscular dystrophy patients.

Duchenne muscular dystrophy (DMD) and Becker muscular dystrophy (BMD) are allelic disorders caused by mutations in the X-linked dystrophin gene. The most common mutations in western populations are deletions that are spread non-randomly throughout the gene. Molecular analysis of the dystrophin gene structure by hybridization of the full length cDNA to Southern blots and by PCR in 62 unrelated Israeli male DMD/BMD patients showed deletions in 23 (37%). This proportion is significantly lower than that found in European and North American populations (55-65%). Seventy-eight percent of the deletions were confined to exons 44-52, half of these to exons 44-45, and the remaining 22% to exons 1 and 19. There was no correlation between the size of the deletion and the severity of the disease. All the deletions causing frameshift resulted in the DMD phenotypes.

Blotting, Southern↗

Use of ultrahigh frequency ventilation in patients with ARDS. A preliminary report.

STUDY OBJECTIVE: Our objective was to compare the efficacy of ultrahigh frequency ventilation (UHFV) (frequencies > 3 Hz) with respect to oxygenation, airway pressures, and hemodynamic parameters in patients with adult respiratory distress syndrome (ARDS) who were not responding to conventional ventilation. DESIGN: We used a prospective, multicenter, nonrandomized study design in which each patient served as his own control. SETTING: Three university-affiliated, tertiary-care medical centers participated. PATIENTS: Persons aged 16 to 79 years old with ARDS and unresponsive to conventional ventilation, as defined by a Food and Drug Administration (FDA) approved protocol, were included. INTERVENTIONS: Ninety patients who were not responding to conventional ventilation were changed to UHFV using a microcomputer-controlled device. MEASUREMENTS AND RESULTS: The patient's blood gas, hemodynamic, and airway pressure variables were measured just before, and at 1 and 24 h after the switch to UHFV. We demonstrated clinically significant improvements in arterial oxygen tension (PaO2) and reductions in peak and mean inspiratory pressures. CONCLUSIONS: In a multicenter study, UHFV improved respiratory gas exchange and reduced airway pressure variables at both 1 h and 24 h after the onset of UHFV when compared with conventional ventilation just prior to the change and without hemodynamic deterioration, in patients with severe ARDS.

Adolescent↗

Techniques for weaning a patient from mechanical ventilation; when to begin, what method to use, and how to predict outcome.

A variety of methods have been employed to help wean patients from prolonged ventilatory support. Although synchronized intermittent mandatory ventilation is probably the most widely used, it has not been shown to be clearly superior to T piece or pressure support weaning. Regardless of the method you choose, begin weaning before the patient's lung function has returned to normal or baseline levels and end when the patient shows the minimum capacity necessary to sustain himself off the ventilator. The patient's response to the change in the level of ventilatory support governs the rapidity of weaning. The rapid shallow breathing index can be useful in predicting weaning outcome, as is the patient's ability to tolerate a weaning trial.

Contraindications↗

Validation of respiratory mechanics software in microprocessor-controlled ventilators.

BACKGROUND AND METHODS: Several microprocessor-controlled ventilators, available for clinical use, contain optional computer software programs capable of performing near-instantaneous determinations of airway resistance and lung compliance. This study was undertaken to determine the validity of the measurements for airway resistance and lung compliance obtained by the software packages on three microprocessor-controlled ventilators. Three ventilator models were studied. An artificial ventilator-patient circuit was constructed using a test lung and an endotracheal tube. Airway pressure and gas flow curves were recorded using conventional means. Static lung compliance and airway resistance were calculated using standard equations, while automated measurements were obtained from the ventilators. The following parameters were then varied to simulate a wide variety of clinical situations: tidal volume, peak inspiratory flow rate, respiratory rate, endotracheal tube, and test lung compliance. RESULTS: Automated measurements were highly correlated with values obtained manually (resistance: Puritan-Bennett 7200a r2 = .94, Bear 5 r2 = .98, Veolar r2 = .96; compliance: 7200a r2 = .93, Bear 5 r2 = .97, Veolar r2 = .97). Calculated limits of agreement between the two methods demonstrate that although not in absolute agreement, the software-determined values for airway resistance and lung compliance differed from the manually derived values in a ventilator-specific, predictable fashion. CONCLUSIONS: The correlation and agreement demonstrated between values of airway resistance and lung compliance measured by the respiratory mechanics software packages and those values derived manually suggest that these software packages may be useful for measuring trends, as well as responding to treatment in the clinical setting. These results apply only to the controlled, mechanical ventilation mode. Further studies are indicated to validate this software in patients capable of generating spontaneous breaths.

Airway Resistance↗

The technique of instituting mechanical ventilation. Patient preparation; endotracheal intubation; monitoring.

Potential indications for mechanical ventilation include hypoxemia unresponsive to oxygen administration, hypercapnia resulting in acidemia, and an unstable chest wall. For best results, carefully prepare the patient (both physically and emotionally) before instituting ventilation. Sedatives and local anesthesia can facilitate intubation; avoid paralytic agents unless you are experienced at intubation. The oral route is most commonly used. Once the patient circuit is attached to the endotracheal tube, reexamine the patient and double-check the inspiratory flow and I:E ratio; adjust the ventilator's settings as necessary. Monitor the patient frequently to ascertain the adequacy of alveolar ventilation and arterial oxygen.

Animals↗

Beyond the basics: operating the new generation of ventilator. A look at the features and functions of these units.

Most modern ventilators have several key features in common: microprocessor control of operational and monitoring functions; electromechanical valves to control and adjust gas flow patterns; and extensive monitoring systems. In addition, these machines can provide a number of different modes of ventilation (including pressure support). Though not microprocessor-controlled, the Siemens Servo 900 series ventilators use feedback electronics to adjust inspiratory flow based on expiratory flow to meet preset volumes. In contrast, the Bennett 7200 units use microprocessor-regulated solenoid valves to deliver preset tidal volume. High-frequency ventilators deliver smaller tidal volumes at rates greater than 60 bpm.

Adult↗

Detection of breast cancer by measuring areolar blood flow--a pilot study.

Regional blood flow in the areola was measured by using the non-invasive transient thermal clearance method in normal breasts and in breasts involved with cancer. Areolar blood flow (ABF) in normal breasts was almost constant for women in the age range 20-60y, but decreased at higher ages. ABF in breasts involved with cancer was higher than that in the contralateral breast, and higher than the average normal ABF in the corresponding age group. The effect was more prominent in the left breast. The transient thermal clearance method provides a potential non-invasive means for detection of breast cancer.

Adult↗

Serial levels of CA 19-9 and CEA in colonic cancer.

The use of serial carbohydrate antigen (CA) 19-9 assays was assessed by comparison with serial carcino-embryonic antigen (CEA) levels on the plasmas of 53 patients with colorectal carcinoma. The patients had all undergone resection for their primary tumors and in six instances subsequent resections for hepatic metastases. Initial CA 19-9 levels were greater than or equal to 37 U/mL in 22 of the 53 patients (41%) and in 68% of the patients with metastatic disease. Similar trends of serial CA 19-9 and CEA levels were found in 79% of the 53 patients. One patient with initially normal CEA levels had elevated CA 19-9 levels from the start. In ten of the 53 patients (19%), serial CA 19-9 levels remained low despite tumor recurrence or progression, and despite increasing CEA levels above 5 ng/mL. The increasing serial CEA trends predicted recurrence in 88% and increasing CA 19-9 trends in 50% of cases, which was increased to 70% by including trends of CA 19-9 levels below 37 U/mL. Following hepatic lobectomy, both serial CEA and CA 19-9 levels decreased rapidly. Used alone, serial CA 19-9 levels did not appear to be as sensitive as standard CEA in this retrospective study of selected patients.

Adult↗