Validation of respiratory mechanics software in microprocessor-controlled ventilators.

Abstract

BACKGROUND AND METHODS: Several microprocessor-controlled ventilators, available for clinical use, contain optional computer software programs capable of performing near-instantaneous determinations of airway resistance and lung compliance. This study was undertaken to determine the validity of the measurements for airway resistance and lung compliance obtained by the software packages on three microprocessor-controlled ventilators. Three ventilator models were studied. An artificial ventilator-patient circuit was constructed using a test lung and an endotracheal tube. Airway pressure and gas flow curves were recorded using conventional means. Static lung compliance and airway resistance were calculated using standard equations, while automated measurements were obtained from the ventilators. The following parameters were then varied to simulate a wide variety of clinical situations: tidal volume, peak inspiratory flow rate, respiratory rate, endotracheal tube, and test lung compliance. RESULTS: Automated measurements were highly correlated with values obtained manually (resistance: Puritan-Bennett 7200a r2 = .94, Bear 5 r2 = .98, Veolar r2 = .96; compliance: 7200a r2 = .93, Bear 5 r2 = .97, Veolar r2 = .97). Calculated limits of agreement between the two methods demonstrate that although not in absolute agreement, the software-determined values for airway resistance and lung compliance differed from the manually derived values in a ventilator-specific, predictable fashion. CONCLUSIONS: The correlation and agreement demonstrated between values of airway resistance and lung compliance measured by the respiratory mechanics software packages and those values derived manually suggest that these software packages may be useful for measuring trends, as well as responding to treatment in the clinical setting. These results apply only to the controlled, mechanical ventilation mode. Further studies are indicated to validate this software in patients capable of generating spontaneous breaths.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R J Korst, R Orlando, N S Yeston, M Molin, A C de Graff, E Gluck. 1992. Validation of respiratory mechanics software in microprocessor-controlled ventilators.. https://doi.org/10.1097/00003246-199208000-00015

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Correction of compliance and resistance altered by endotracheal tube leaks and non-linear pressure/volume-relationships.

Measurements of lung compliance (C) and resistance (R) are influenced by endotracheal tube leaks (ETTL) as well as non-linear pressure/volume relationships (P/V relationship). To keep C and R reliable, we developed an algorithm to mathematically correct inspiratory and expiratory volume (V) and flow. In this study, a ventilated lung model for non-linear P/V relationship with adjustment of an increasing ETTL was studied. In addition, the recordings (airway pressure, flow, and volume) of 21 infants (median weight: 1,220 g, range: 640-2,160 g, with a median leak size of 32%, range: 24-56%) were investigated. C and R were calculated continuously from the recordings of flow, volume, and airway pressure over time according to the changing volume. A method especially developed for the analysis of non-linear pressure-volume-relationship (APVNL) was employed. C and R affected by leaks were corrected applying the newly developed mathematical algorithm and compared with measurements without leakage. C could be corrected up to a leak of 80% and R up to 55% leak at half tidal V for the model with non-linear P/V-R. C and R without leak and after leak correction did not differ significantly in all infants where the APVNL method was applied (P > 0.05).

Airway Resistance↗

Parenchymal tethering, airway wall stiffness, and the dynamics of bronchoconstriction.

We do not yet have a good quantitative understanding of how the force-velocity properties of airway smooth muscle interact with the opposing loads of parenchymal tethering and airway wall stiffness to produce the dynamics of bronchoconstriction. We therefore developed a two-dimensional computational model of a dynamically narrowing airway embedded in uniformly elastic lung parenchyma and compared the predictions of the model to published measurements of airway resistance made in rats and rabbits during the development of bronchoconstriction following a bolus injection of methacholine. The model accurately reproduced the experimental time-courses of airway resistance as a function of both lung inflation pressure and tidal volume. The model also showed that the stiffness of the airway wall is similar in rats and rabbits, and significantly greater than that of the lung parenchyma. Our results indicate that the main features of the dynamical nature of bronchoconstriction in vivo can be understood in terms of the classic Hill force-velocity relationship operating against elastic loads provided by the surrounding lung parenchyma and an airway wall that is stiffer than the parenchyma.

Airway Resistance↗

Use of dynamic compliance for open lung positive end-expiratory pressure titration in an experimental study.

OBJECTIVE: We tested whether the continuous monitoring of dynamic compliance could become a useful bedside tool for detecting the beginning of collapse of a fully recruited lung. DESIGN: Prospective laboratory animal investigation. SETTING: Clinical physiology research laboratory, University of Uppsala, Sweden. SUBJECTS: Eight pigs submitted to repeated lung lavages. INTERVENTIONS: Lung recruitment maneuver, the effect of which was confirmed by predefined oxygenation, lung mechanics, and computed tomography scan criteria, was followed by a positive end-expiratory pressure (PEEP) reduction trial in a volume control mode with a tidal volume of 6 mL/kg. Every 10 mins, PEEP was reduced in steps of 2 cm H2O starting from 24 cm H2O. During PEEP reduction, lung collapse was defined by the maximum dynamic compliance value after which a first measurable decrease occurred. Open lung PEEP according to dynamic compliance was then defined as the level of PEEP before the point of collapse. This value was compared with oxygenation (Pao2) and CT scans. MEASUREMENTS AND MAIN RESULTS: Pao2 and dynamic compliance were monitored continuously, whereas computed tomography scans were obtained at the end of each pressure step. Collapse defined by dynamic compliance occurred at a PEEP of 14 cm H2O. This level coincided with the oxygenation-based collapse point when also shunt started to increase and occurred one step before the percentage of nonaerated tissue on the computed tomography exceeded 5%. Open lung PEEP was thus at 16 cm H2O, the level at which oxygenation and computed tomography scan confirmed a fully open, not yet collapsed lung condition. CONCLUSIONS: In this experimental model, the continuous monitoring of dynamic compliance identified the beginning of collapse after lung recruitment. These findings were confirmed by oxygenation and computed tomography scans. This method might become a valuable bedside tool for identifying the level of PEEP that prevents end-expiratory collapse.

Airway Resistance↗