PubMed Health⌕ Search

Biomedical subjects

E Grabbe

Publications and source records attributed to E Grabbe.

At least 37 records · Page 2Linked to original sources

18F-FDG hybrid PET in patients with suspected spondylitis.

This study investigated the value of fluorine-18 2'-deoxy-2-fluoro- D-glucose (FDG) imaging with a double-headed gamma camera operated in coincidence (hybrid PET) detection mode in patients with suspected spondylitis. Comparison was made with conventional nuclear medicine imaging modalities and magnetic resonance imaging (MRI). Sixteen patients with suspected spondylitis (nine male, seven female, mean age 59 years) prospectively underwent FDG hybrid PET (296 MBq) and MRI. For intra-individual comparison, the patients were also imaged with technetium-99m methylene diphosphonate (MDP) (555 MBq) ( n=13) and/or gallium-67 citrate (185 MBq) ( n=11). For FDG hybrid PET, two or three transverse scans were performed. Ratios of infected (target) to non-infected (background) (T/B) vertebral bodies were calculated. MR images were obtained of the region of interest. Patients found positive for spondylitis with MRI and/or FDG hybrid PET underwent surgical intervention and histological grading of the individual infected foci. Twelve out of 16 patients were found to be positive for spondylitis. Independent of the grade of infection and the location in the spine, all known infected vertebrae ( n=23, 9 thoracic, 12 lumbar, 2 sacral) were detected by FDG hybrid PET. T/B ratios higher than 1.45+/-0.05 (at 1 h p.i.) were indicative of infectious disease, whereas ratios below this value were found in cases of degenerative change. FDG hybrid PET was superior to MRI in patients who had a history of surgery and suffered from a high-grade infection in combination with paravertebral abscess formation ( n=2; further computed tomography was needed) and in those with low-grade spondylitis ( n=2, no oedema) or discitis ( n=2, mild oedema). False-positive 67Ga citrate images ( n=5: 2 spondylodiscitis, 1 aortitis, 1 pleuritis, 1 pulmonary tuberculosis) and 99mTc-MDP SPET ( n=4: 1 osteoporosis, 2 spondylodiscitis, 1 fracture) were equally well detected by FDG hybrid PET and MRI. No diagnostic problems were seen in the other patients ( n=5). In this study, FDG hybrid PET was superior to MRI, 67Ga citrate and (99m)Tc-MDP, especially in patients with low-grade spondylitis (as compared with MRI), adjacent soft tissue infections (as compared with 67Ga citrate) and advanced bone degeneration (as compared with 99mTc-MDP).

Adult↗

[Quality management in a radiology department].

PURPOSE: To increase the quality of internal and external interactions (patients, clinical colleagues, technicians, radiologists) in a department of radiology. METHOD: Accompanied by a well-experienced adviser workshops have been performed dealing with different topics like "contact to patients," "performance of the radiological report and interaction with the referring colleague" or "research and teaching." A catalogue of different actions was defined to reduce hindrances within the internal and external work-flow. RESULTS: A total number of 53 actions was defined and related to different persons who were responsible for the realisation of the measures within a time interval. Six months after starting the quality management 46 (86%) of the defined actions were realised successfully, and another 4 (8%) measures were still running. There was a moderate increase of satisfaction of the patients and clinical colleagues considering the waiting time. CONCLUSIONS: A quality management in a radiological department allows an optimisation of the internal and external interactions. However, the guidance of a well-experienced adviser is as essential as the continuous control of successful finished measures.

Education↗

[Soft copy versus hard copy findings in digital mammography].

The advantages of full field digital mammography are the excellent and reliable image quality and the reduction of radiation exposure. Image acquisition and display are decoupled in digital mammography allowing for optimization of both independently. Image displays are currently either hardcopy produced with a laser printer or softcopy using a computer monitor. Since the amount of data is high the hardware and software must meet specific technical specifications. The diagnostic accuracy of softcopy and hardcopy interpretation is comparable if a high resolution laser printer and a high quality workstation with high spatial and contrast resolution monitors are used. However, using film display the potential benefits of digital mammography in terms of manipulation of the data is lost. Additional diagnostic benefits might be gained by the combination of softcopy display and computer assisted diagnosis (CAD) and telemammography.

Breast Neoplasms↗

[Digital full field mammography: comparison between radiographic direct magnification and digital monitor zooming].

PURPOSE: Our goal was to compare digital magnification mammograms with images zoomed from the digital contact mammogram in patients with microcalcifications. PATIENTS AND METHODS: Fifty-five patients with 57 microcalcification clusters were evaluated with a FFDM system (Senographe 2000D, GE). In addition to a digital contact mammogram, a digital direct magnification mammogram (factor 1.8 [MAG1.8]) and an image zoomed from the contact mammogram with a magnification factor of 1.8 [ZOOM1.8] were obtained in each patient. The image quality (perfect = 5 points to inadequate = 1 point) and the characterization of microcalcifications (BI-RADS 2-5) were evaluated by 4 readers. The results were compared to histopathologic findings in 35 patients (37 lesions) and follow-up in 20 patients. RESULTS: Histopathology revealed 16 benign and 21 malignant lesions. 20 patients had benign changes verified by long-term follow-up. Image quality of direct magnification FFDM was assessed superior (4.44 points) to zoomed images (4.14 points). Sensitivity was superior for direct magnification (97.5%) in comparison to the zoomed images (96.3%). However, specificity (MAG1.8: 34.3%, ZOOM1.8: 40%), PPV (MAG1.8: 47.5%, ZOOM1.8: 49.8%) and accuracy (MAG1.8: 58.1%, ZOOM1.8: 61.2%) were better with zooming technique. Deviation steps from best BI-RADS assessment were 0.45 for MAG1.8 and 0.44 for ZOOM1.8. CONCLUSIONS: In patients with mammographic microcalcifications, monitor zooming of the digital contact mammogram is equivalent to direct magnification FFDM. Therefore, monitor zooming allows a reduction of the radiation exposure and an optimization of the work-flow.

Breast Diseases↗

[Physical and technical aspects of digital mammography].

The establishment of digital mammography systems constitutes a slow process, the reason for this being the general need of particular image quality in mammography. This article provides an overview of the physical basis of digital mammography with high image quality and dose as low as reasonably achievable. The trade-off of high contrast resolution and effective quantum efficiency of the imaging system on the one hand, and the demand of high spatial resolution or very small pixel size on the other hand is discussed. The actual status of the available digital detector technology for mammography is described. The digital systems presently available are superior to conventional screen-film mammographic systems with respect to contrast resolution. An outlook on possible further developments in the field of digital mammography is presented.

Equipment Design↗

[Morphological and functional MRI studies after correction of aortic isthmus stenosis].

PURPOSE: To compare the results of different methods for postoperative assessment after coarctation repair by magnetic resonance imaging and to evaluate their reliability. The morphometric results are contrasted to functional parameters of CW Doppler, oscillometric pressure gradient and flow quantification in VEC-MRI. METHODS: 54 patients (age: 6 to 36 years) were assessed by MRI 3 to 31 years after coarctation repair. The aortic diameters were compared to growth-dependent normal values and to the diameter of the ascending (AA) and descending aorta (DA), and their mean values (MV). RESULTS: Patients after coarctation repair had mostly subnormal diameters of AA (mean value: 80% of normal) and AD (95% of normal). Compared to the control group, mean dispersion of AD diameters was significantly larger in the patient group (2.6 vs. 1.5 mm, p < 0.001). Degree of stenosis varied with the method. It was similar when using normal values and the diameter for DA, but dispersion was smaller when normal values were used. Correlation of the functional parameter to the degree of stenosis was weak. The highest correlation (r = 0.78) was reached when using normal values as the reference with mean cross-sectional velocity from VEC-MRI. CONCLUSION: The use of normal values as the reference for quantification of residual coarctation is more reliable than common methods. Since only one measurement is needed, it seems to be less susceptible to errors and more practical. MRI offers not only a tool for accurate morphologic assessment, but with VEC-MRI it is also possible to obtain a functional parameter which is superior to oscillometric pressure gradient and CW Doppler.

Adolescent↗

[Indications for percutaneous stereotactic vacuum core biopsy of the breast].

As a consequence of technical improvements and an increased number of investigations in asymptomatic patients, more and more suspicious lesions are being detected in mammography. These lesions can be evaluated using different biopsy techniques. In comparison to open biopsy, stereotactic methods require less costs and time, and reduce morbidity. The introduction of the vacuum core biopsy method allowed the excision of suspicious areas through a single needle insertion. In the current literature, however, the indications for vacuum core biopsy are being discussed controversely. This article includes an introduction of this specific technique, a presentation of the BI-RADS (Breast Imaging Reporting and Data System) categories and an overview of the literature of the indications for use of the vacuum system. The "pros and cons" of vacuum core biopsy will be discussed in comparison with the alternative biopsy methods.

Biopsy↗

Average glandular dose with amorphous silicon full-field digital mammography - Clinical results.

PURPOSE: Determination of average glandular dose with a full-field digital mammography system using a flat-panel X-ray detector based on amorphous silicon technology for a large group of patients. MATERIAL AND METHODS: The patient group includes women who were examined in a 4-month period with the digital mammographic system Senographe 2000D. The number of women was 591 and the number of exposures was 1116; only cranio-caudal projections were considered. Various quantities, including entrance surface air kerma, tube loading, and compressed breast thickness, were determined during actual mammography. Average glandular dose was determined using conversion factors g for standard breast composition. RESULTS: The mean average glandular dose was 1.51 mGy (0.66 - 4.05 mGy) for a single view. The mean compressed breast thickness was 55.7 mm. The mean age of patients was 55 years (34 - 81 years). CONCLUSION: The results demonstrate that full-field digital mammography with a flat-panel detector based on amorphous silicon needs about 25 % less dose in comparison with conventional screen-film mammography.

Adult↗

[Multislice helical CT (MSCT) for mid-facial trauma: Optimization of parameters for scanning and reconstruction].

PURPOSE: To determine the optimal scan parameters in multislice helical CT (MSCT) of the facial bone complex for both axial scanning and multiplanar reconstructions. MATERIAL AND METHODS: An anthropomorphic skull phantom was examined with a MSCT. Axial scans were performed with continuously increasing collimations (4 x 1.25 - 4 x 2.5 mm), tube current (20 - 200 mA) and table speeds (3.75 mm/rot. and 7.5 mm/rot.). Multiplanar reconstructions in coronal and parasagittal planes with different reconstruction increment and slice thickness were evaluated in terms of image noise, contour artifacts and visualisation of anatomical structures. RESULTS: The best image quality was obtained with a collimation of 4 x 1.25 mm and a table speed of 3.75 mm/rot. A reconstruction increment of 0.6 mm achieved the best time to image quality relation. With these parameters the bone structures were depicted in an optimal way without artifacts. The tube current could be reduced to 50 mA without significant loss of image quality. The optimized protocol was used for regular routine examinations in patients with facial trauma (n = 66). CONCLUSIONS: Low-dose MSCT using thin collimation, low table speed and small reconstruction increments provides excellent data for both axial images and multiplanar reconstructions in patients with facial trauma. An additional examination in coronal orientation is therefore no longer necessary.

Adult↗

Receptor binding kinetics of human IL-3 variants with altered proliferative activity.

The binding kinetics of native IL-3 and a set of truncated IL-3 variants to the alpha subunit of the IL-3 receptor (IL-3Ralpha) were studied using surface plasmon resonance. These variants, with amino acid substitutions at residues, 22, 42, 43, 45, 46, 113, or 116, have previously been identified to have altered capacity to stimulate cell proliferation compared to native IL-3(1-133). In this study, variants E43N and F113Y exhibited >100-fold slower association rates than IL-3(15-125) consistent with residues 43 and 113 being essential for the binding of IL-3 to the IL-3Ralpha. Variants G42A, G42D, Q45V, D46S, K116V, and K116W exhibited increased association rates (up to 15-fold relative to IL-3(15-125)) and decreased dissociation rates (up to 7-fold). The results demonstrate that both the association and dissociation rates for the binding of IL-3 to the IL-3Ralpha are altered by truncation and by amino acid substitution at individual sites. Intracellular signaling studies using K116W and E43N demonstrate that differences in the IL-3alpha binding characteristics are reflected in magnitude and kinetics of STAT5 phosphorylation.

Amino Acid Substitution↗

Preoperative local MRI-staging of patients with a suspected pancreatic mass.

The aim of this study was to define the value of MRI of the pancreas for preoperative local staging of patients with a suspected pancreatic mass. Ninety-four patients (41 women, 53 men; age range 32-87 years) with a suspected pancreatic tumor underwent preoperative staging with MRI on a 1.5-T system. The MRI protocol included breath-hold MR cholangiopancreatography in turbo spin-echo technique, biphasic contrast-enhanced 3D MR angiography, and MRI of the upper abdomen with breath-hold T2-weighted half-Fourier acquired single-shot turbo spin-echo and T1-weighted fast-low-angle-shot (pre- and postcontrast) sequences. Data were collected prospectively and analyzed by two radiologists in agreement modality. Evaluation criteria were vascular involvement, resectability, and a characterization benign vs malignant. Results were compared to histopathology in 78 patients. Sixteen patients were followed-up. In 74 of 94 patients a solid tumor or an inflammation of the pancreas ( n=62) or the papilla ( n=12) was detected. In this group, MRI had a sensitivity of 98%, a specificity of 92%, and an accuracy of 96% in the characterization of malignant tumors. Regarding only the solid tumors, the positive predictive value of MRI was 87% with respect to resectability. Other pathologic findings included adenoma or inflammation of the duodenum ( n=5), carcinoma or benign stenosis of the choledochus duct ( n=7) and carcinoma of the gall bladder ( n=2). In 6 patients MRI did not depict any pathologic findings, and follow-up confirmed this interpretation. Magnetic resonance imaging allows a local preoperative staging in patients with suspected pancreatic tumor. Limitations, however, concern to the diagnostics of peritoneal and/or liver metastases.

Adult↗

[Value and significance of digital full-field mammography within the scope of mammography screening].

To evaluate the digital technique for screening mammography various experimental studies and clinical examinations were performed by using direct full-field digital mammography (FFDM). The findings concerning the detectability and characterization of microcalcifications and soft tissue masses as well as the radiation exposure were compared to the state-of-the-art conventional screen-film mammography (SFM). The results of these studies revealed a high performance of the digital images, which are at least equivalent to the conventional images, whereas digital spot views were significantly superior to conventional ones particularly in the detection of microcalcifications. This was especially true, when the potential of post-processing was used. In addition, the sensitivity of FFDM should be increased, if computer-aided-diagnosis (CAD) is available. Furthermore, the patient radiation dose can be significantly reduced. Additional advantages are quick and easy handling, efficient data transfer and digital archiving. Thus, FFDM will become an important tool in screening mammography.

Breast Neoplasms↗

[MR-angiography in portal hypertension. State of the art].

When imaging the portal vascular system colour-coded sonography and CT angiography are used as an alternative to intraarterial DSA. Today fast CE 3D-MRA is the imaging modality of choice in the diagnostic of patients with portal hypertension. It enables a clear picture of the portalvenous vascular system and portalsytemic shunts. Statements regarding velocity and direction of blood flow can be made with additional use of TOF and PC techniques. CE-3D MRA can be used preoperatively before liver transplantation or shunt surgery. In the follow-up of interventional or surgical procedures exact statements concerning haemodynamically significant pathologies e.g. vascular thromboses, stenoses and occlusions can be made. Patient consent is symplify and the numbers of complications can be reduced as well as duration of surgery minimized applying this technique.

Collateral Circulation↗

[Intramural hematomas of the aorta].

Intramural hematomas (IMH) are regarded as a hemorrhage into the aortic wall. In general a traumatic form can de differentiated from a spontaneous non-traumatic. There is a predisposition of IMH with arterial hypertension and mesoectodermal dysplastic syndromes. The diagnosis is established with the clinical presentation in combination with the findings of different imaging modalities. Acute and subacute discomfort associated with a tendency of collaps are considered as typical presenting complaints. A semicircular or concentric thickening of the aortic wall with the absence of blood flow or a dissection membrane are typical findings in transesophageal echocardiography, computed tomography and magnetic resonance tomography. From a differential diagnostic point of view a distinction from atherosclerotic wall changes, intraluminal thrombi and inflammatory aortic diseases is essential. The IMH is considered as an early presentation of aortic dissection, put into and treated according to the Stanford classification. In the course of natural history an IMH can disappear, rupture or progress into a classic aortic dissection.

Aortic Dissection↗

[Diagnosis of lung embolism and underlying venous thrombosis in multi-slice spiral CT].

AIM: To determine the value of multi-slice CT for the diagnosis of acute pulmonary embolism and an underlying venous thrombosis. METHODS: 70 patients with clinically suspected acute pulmonary embolism were examined. Using multi-slice CT a combined examination of the pulmonary arteries and the veins of the lower limb, pelvis and abdomen was performed. Only one single bolus of 150 ml iopromid 300 was injected into a cubital vein with a flow of 4 ml/s. First, the pulmonary arteries were scanned with a slice thickness of 2.5 mm and a pitch of 1.5. On arrival of the contrast medium at the popliteal veins, indicated by bolus trakking, the veins of the lower limbs up to the end of the inferior vena cava were imaged using a slice thickness of 3.75 mm and a pitch of 1.5. The results could be compared with a ventilation-perfusion scan in 48 cases, with a Doppler ultrasound examination in 46 cases, and with a venography in 10 cases. Furthermore, the image quality of all arterial and venous regions was subjectively assessed. RESULTS: In all patients who underwent multi-slice CT the pulmonary arteries as well as the veins of the lower half of the body could be recorded completely. Regarding the pulmonary arteries the image quality showed excellent results for the central and segmental arteries. The region up to the 3rd division in subsegmental branches could be sufficiently judged. More peripherally, a diagnostic assessment was not possible. The image quality of the veins was excellent in all sections, except the calf, where a reliable diagnosis could not be made. The comparison with the other techniques confirmed the superiority of multi-slice CT concerning the central and segmental pulmonary arteries and the veins from the popliteal vein to the inferior vena cava. In contrast, peripheral pulmonary emboli can be detected more certainly in ventilation/perfusion scans. The veins of the calf can be evaluated more reliably with venography. CONCLUSION: Multi-slice CT proved to be an outstanding tool in the diagnosis of acute pulmonary embolism. The clinically suspected disease and a causing venous thrombosis can be detected in a fast and reliable way. At present, multi-slice CT is not suitable for the recognition of peripheral emboli. However, expected technical developments hold promise for future improvements.

Adult↗

[Stereotactic vacuum core biopsy of clustered microcalcifications classified as B1-RADS 3].

PURPOSE: Evaluation of stereotactic vacuum core biopsy of clustered microcalcifications categorized as BI-RADS 3. MATERIAL AND METHODS: 86 patients with microcalcifications BI-RADS 3 (probably benign, < 3% malignant) underwent a stereotactic vacuum core biopsy (Mammotome, Fa. Ethicon Endo-Surgery Breast Care) using a digital stereotactic unit (Mammotest, Fa. Fischer Imaging). The removal of the calcifications was judged by two radiologists in consensus and classified as complete (100%), major (55-99%) or incomplete (< 50%). RESULTS: 4/86 patients could not be evaluated by vacuum core biopsy due to the localization of the microcalcifications close to the skin or lack of detection. In 40/82 cases a complete, in 38/82 a major, and in 4/82 a incomplete removal was achieved. Histology revealed 67 cases of fibrocystic changes, 4 papillomas, 4 fibroadenomas, 4 cases of atypical ductal hyperplasia (ADH), and 3 ductal carcinomas in situ (DCIS), one of these with a minimal-invasive tumor component. Patient with ADH were advised to undergo surgical biopsy. Histology revealed complete removal. 7 patients had complications or side-effects. CONCLUSIONS: Percutaneous vacuum core biopsy is a reliable minimal-invasive diagnostic method to come to the final diagnosis in patients with clustered microcalcifications categorized BI-RADS 3. However, if malignancy is proven (about 4% of our cases) an open biopsy is necessary.

Adult↗

[Experimental evaluation of vessel diameter from 0.3 to 8 mm in CE MR angiography].

PURPOSE: To evaluate the detection rate of vascular stenosis in contrast-enhanced 3D MR angiography using a flow phantom. MATERIAL AND METHODS: The examinations were performed on a 1.5 T whole body imaging system (Magnetom Symphony/Quantum) with 30 mT/m gradient field strength using a body-phased-array coil. Different 3D sequences (TR/TE/FA < 5 ms/< 2 ms/25 degrees ) with slice thicknesses ranging from 0.67 to 1.25 mm were applied. A gelantine-filled plastic cylinder with PVC tubes of 8 mm diameter was used as a vascular phantom. The tubes had concentric and excentric stenoses (50 - 90 %) of different lengths. For the detection of different vessel diameters another phantom with 0.3 - 8 mm silicon tubes was used. Both systems were flushed with a solution of Gd-DTPA (0.15 mmol/l) and saline at flow rates from 50 to 200 cm/s. The phantoms were positioned 0 degrees, 45 degrees, and 90 degrees towards the z-axis. RESULTS: The degree of stenosis was under- and overestimated in less than 10 %. The sequence with the highest spatial resolution provided the best results. Detection and evaluation of tubes >/= 2 mm proved to be reliable. CONCLUSION: Contrast-enhanced 3D MR angiography provides an almost exact evaluation of the degree of stenosis in the phantom study. Evaluation of vessel diameters < 2 mm is not possible.

Arterial Occlusive Diseases↗

[Impact of different iodine concentrations on abdominal enhancement in biphasic multislice helical CT (MS-CT)].

UNLABELLED: Impact of different iodine concentrations on abdominal enhancement in biphasic multislice helical CT (MS-CT). PURPOSE: To evaluate if different iodine concentrations of a contrast material (c.m.) have an impact on abdominal enhancement in MS-CT during the arterial (AP) and portal venous phase (PVP). MATERIALS AND METHODS: 75 patients underwent biphasic CT of the abdomen. They were assigned to three equally sized groups. For all patients a non-ionic c.m. (iopromide, Ultravist, Schering AG, Berlin) with different iodine concentrations and a constant total iodine load of 37 g with an injection flow rate of 4 ml/s was used. The volume of the c.m. differed depending on the iodine concentrations: group 1 (123 ml of 300 mgl/ml); group 2 (112 ml of 335 mgl/ml); group 3 (100 ml of 370 mgl/ml). The scan delay was optimized by using a bolus tracking device. The groups were compared concerning their mean enhancement of aorta, spleen, pancreas, and liver in the AP and PVP. RESULTS: The comparison of the three groups showed an improved enhancement in aorta, spleen, and pancreas during the AP by using the higher c.m. concentrations. In the PVP the c.m. enhancement of aorta, liver, spleen, and pancreas was independent of the administered c.m. concentration. CONCLUSION: Higher iodine concentrations of c.m. have a positive impact on abdominal enhancement during the AP. The concentration has no influence on the enhancement during the PVP of abdominal MS-CT.

Adult↗