[Fractures of the cervical vertebrae: diagnosis with multi-slice spiral CT].

PURPOSE: It is the aim of this study to investigate the efficiency of multislice helical CT for the diagnosis of cervical spine fractures. The advantages of this technique are demonstrated by case reports. MATERIAL AND METHODS: The entire cervical spine or selected vertebral bodies of 66 patients with cervical spine fractures known from preceding plain films were scanned with a multislice helical CT. The CT-scans were obtained with a slice thickness of 1.25 mm and with two different pitches (0.75 or 1.5) and table speeds (3.75 or 7.5 mm/rot.). Additionally, sagittal and coronal reformations were performed. RESULTS: The mean scan-time for the cervical spine was 13 seconds. High quality sagittal and coronal reformations were obtained from axial images within a few minutes. Fractures of the dens (n = 17) and of the vertebral body of C3-C7 (n = 12) occurred predominantly. CONCLUSION: Multislice helical CT is an effective tool to diagnose fractures of the cervical spine rapidly and exactly.

Adult↗

[Virtual endoscopy of the upper airway with spiral CT].

PURPOSE: The technical conditions, the optimized scanning protocols and the facilities of virtual endoscopy (VE) are presented in an overview. METHODS: Phantom studies showed that, for a single-row-detector helical CT, collimation of 3.0 mm combined with pitch of 1.5 provided an optimal compromise between image quality and the scan duration per breath-hold. A multi-row-detector helical CT requires only a fraction of the scanning time. This is especially important for patients with dyspnea. RESULTS: The threshold-dependent virtual endoscopic surface rendering is a reliable and rapidly practicable reconstruction algorithm for the imaging of the upper airway. CONCLUSIONS: The VE technique is suitable for the imaging of space-occupying tumors and restricted stenoses. With VE follow-up examinations can be performed non-invasively and interventional procedures can be prepared in an optimal way. Because of the computed tomographic data acquisition the structure of the mucosa is not assessable and there is no opportunity to obtain a biopsy specimen.

Bronchoscopes↗

A multipurpose phantom for quality assurance of contrast-enhanced MR imaging of the breast.

A phantom consisting of four components was developed to simulate contrast-enhanced MR imaging of the breast. These components included the correlation between the signal intensity and the contrast medium concentration, the uniformity of signals within surface coils, artefacts due to opposed-phase imaging effects, spatial resolution and the acquisition of relevant signal-to-time curves. Repetitive measurements demonstrated an excellent reproduction of phantom imaging with a deviation in signal intensity of approximately 5 %. The presented phantom allows the optimization of examination protocols as well as the comparison of different examination techniques. Furthermore, it enables the routine quality monitoring of contrast-enhanced MR imaging of the breast.

Breast↗

3D MR angiography of the entire aorta: modified application of the body-phased array coil for a single-shot technique.

OBJECTIVE: Evaluation of different contrast-enhanced MR angiography imaging protocols for visualization of the entire aorta in breath-hold technique. METHODS AND PATIENTS: Three different CE (0.15 mmol/kg) MRA protocols were evaluated by phantom and patient studies: (1) two separate MRA with conventional application of the body-phased array coil; (2) a single-shot MRA with modified application of the body-phased array coil; (3) a single-shot MRA with the body coil. Duplex sonography, CTA and DSA were used as standard of reference. RESULTS: In all examinations the entire aorta could be visualized. The best SNR was acquired with protocol (1). The SNR of protocol (2) was reduced if the sagittal body diameter of the patient was greater than 20 cm and decreased significantly with diameters over 30 cm. By the use of protocol (3) the SNR was notably poor. The quality scored for the visualization of the entire aorta was 97.5% (protocol 1); 92.5% (protocol 2); and 80.0% (protocol 3). CONCLUSION: In most cases the modified application of the body-phased array coil allows the imaging of the entire aorta as a single-shot 3D CE MRA in diagnostic quality.

Adolescent↗

[Stent artifacts in 3D MR angiography: experimental studies].

PURPOSE: The purpose of this phantom study was to evaluate the visualization of vascular stents by using contrast-enhanced (CE) 3D MR angiography (MRA). METHODS: The measurements were performed on a Magnetom Vision operating at 1.5 T with 25 mT/m gradients by using a head coil; a 3D FISP sequence (TR/TE/FA 4.6 ms/1.8 ms/30 degrees) was used. A phantom was designed with a length of 20 cm and consisted of a plastic cylinder filled with hydrogel. Tubes were used to install 7 different stents (Strecker, Boston Scientific; Cragg, Mintec; Wall, Schneider; Memotherm, Angiomed; St-Come, Trigon-MTS; Sinus, Optimed; Palmaz, Johnson & Johnson) with different metal components. The tubes were perfused with a solution of water and Gd-DTPA. Four radiologists evaluated the image quality. The measurements of the endoluminal stent diameters were compared with the findings obtained by digital subtraction angiography. The signal intensities were measured before (inflow), within (stent) and after (outflow) the different stent types. RESULTS: The endoluminal diameter of the Cragg stent and the strecker graft were easily detectable. The signal loss within the lumen of the Wall stent was approx. 10% in relation to the inflow and outflow measurements. The result was an only slightly reduced image quality. The other grafts (St-Come, Sinus, Palmaz, Memotherm) showed significant signal losses ranging from 65% to 96%. A correct diagnosis was not possible within these graft lumina. CONCLUSION: Contrast-enhanced MR angiography can be used to evaluate vascular stents. A prerequisite is the application of particular commercially available grafts.

Angiography, Digital Subtraction↗

[Full-field digital mammography: a phantom study for detection of microcalcification].

OBJECTIVES: The study compares direct full-field digital mammography (FFDM) to the state-of-the-art conventional screen-film mammography (SFM) concerning the detectability of simulated microcalcifications. MATERIALS AND METHODS: The investigations were performed with a FFDM system (Senographe 2000D, GEMS) and a SFM system (Senographe DMR, GEMS, Fuji UM MA film with Fuji UM MAMMO FINE screen). An anthropomorphic breast phantom with superimposed microcalcifications (50-200 microns) was used to evaluate the detectability of microcalcifications with a confidence level ranging from 1 to 5. Contact mammograms and magnification spot views (m = 1.8) of the FFDM and SFM systems were compared. A receiver operating characteristic (ROC) analysis was performed by three well-experienced readers. RESULTS: The ROC analysis revealed a higher performance of the digital images compared to the conventional screen-film mammograms. The area under the ROC-curve (Az) in the digital contact mammograms was 0.68 versus 0.63 in the conventional technique. The results were not significantly different. In digital spot views, Az was 0.79 versus 0.70 in the conventional spot views. CONCLUSIONS: The results suggest that FFDM is at least equivalent or--as far as spot views are concerned--may be superior to conventional SFM in the detection of microcalcifications.

Breast Diseases↗

[The radial scar in contrast media-enhanced MR mammography].

INTRODUCTION: In patients with the mammographic findings of a radial scar, contrast enhanced (CE) MR mammography was evaluated in a retrospective study. MATERIAL AND METHODS: In 24 women with radial opacities and black star configurations, CE MR mammography was performed. Examinations were done on a 1.5 T system using bilateral superficial coil (2D technique, T1-weighted FLASH-sequence, TR 336 ms, TE 5 ms, FA 90 degrees). Findings in mammography and MR mammography were compared with the histological results. RESULTS: 15 radial scars (including 4 with additional ADH) and 9 carcinomas (6 in coexistence with a radial scar) presenting with a diameter of 3 mm to 13 mm were evaluated. There was no evidence of malignancy in MRI in 12 of 15 radial scars. In MR mammography 6 of the carcinomas fulfilled the criteria for malignant tumors. There were 3 borderline cases (scored 3 points) corresponding histologically to 1 radial scar, and to 2 carcinomas. Within the results found in MRI there were 2 false positives and 1 false negative. CONCLUSION: CE MR mammography is superior to other imaging modalities in the differentiation between radial scars and carcinomas. However, lesions suggestive of radial scars have to be removed surgically.

Adult↗

[Radiation exposure in full-field digital mammography with a flat-panel x-ray detector based on amorphous silicon in comparison with conventional screen-film mammography].

PURPOSE: Comparison of radiation exposure between a digital amorphous silicon and a screen-film based mammography system. Evaluation of a possible potential of full-field digital mammography in order to decrease the radiation dose. METHODS: The average glandular dose for phantom thicknesses from 30 to 60 mm was calculated from experimentally determined entrance surface air kerma for a digital and a conventional mammography system. The effect of reducing the detector dose and of changing the radiation quality on radiation exposure and on image quality were investigated. RESULTS: By using the delivered settings of the automatic exposure control (AEC) devices, both mammographic systems needed nearly the same doses. Regulations and guidelines on radiation doses were complied. With the digital system, a reduction of radiation exposure of up to 40% by using a higher radiation quality and decreasing slightly the detector dose without loss of diagnostic image quality, might be possible. CONCLUSION: The potential of full-field digital mammography for radiation dose reduction, as shown in the present phantom study, needs however, a careful examination under clinical conditions.

Female↗

[Multislice CT angiography: optimization of scan parameters in a vascular phantom].

PURPOSE: The aim of this study is to determine the optimal scan parameters for the evaluation of experimental vascular stenoses with a multislice-helical CT. MATERIAL AND METHODS: A vascular phantom consisting of four tubes with an inner diameter of 8 mm and with experimental stenoses of 50%, 75% and 90% was scanned in different tube orientations using a multislice-CT scanner (LightSpeed QX/i, GE, Milwaukee, USA). Examinations were performed with increasing collimations (1.25-5 mm), tube currents (100-300 mA) and two different table speeds (0.75 HQ mode and 1.5 HS mode). RESULTS: The most exact measurements were obtained in tubes angulated parallel to the scan direction with a collimation of 2.5 mm in the HQ mode (7.5 mm/rot.). An almost equivalent accuracy was obtained in the HS mode (15 mm/rot.) with a collimation of 2.5 mm when higher tube currents (300 mA) were employed. The degree of stenoses was overestimated when the tube was angulated perpendicular to the z-axis. CONCLUSION: Multislice-CT provides a good detection rate of vascular stenoses especially at 0 degree and also at 45 degrees angulation in the HQ mode. The use of the HS mode with higher tube currents allows scanning of longer distances with almost identical accuracy.

Angiography↗

[Full-field digital mammography: dose-dependent detectability of breast lesions and microcalcinosis].

OBJECTIVES: The study compares contrast-detail and microcalcification detectability of a full-field digital mammography (FFDM) to a state-of-the-art conventional screen-film mammography (SFM) by using different doses in the digital system. MATERIALS AND METHODS: The investigations were performed with an FFDM (Senographe 2000 D, GEMS) and an SFM system (Senographe DMR, GEMS) using a contrast-detail mammography phantom (CDMAM) and an anthropomorphic breast phantom with superimposed microcalcifications. The digital detector was exposed with standard dose of SFM and with a dose reduction of up to 75%. Contrast-detail curves and correct observation ratio (COR) were performed for the CDMAM phantom. ROC analysis with a confidence level ranging from 1 to 5 was done with the results of the anthropomorphic phantom. RESULTS: Digital mammography with the same dose revealed at least an equivalent or even higher detectability rate than conventional mammography, COR could be increased at about 10-25%. The ROC analysis yielded better results for the FFDM system. The same lesion detectability in digital mammography as in the conventional method was reached at a dose reduction of about 25%, concerning spot views even at higher reduction. Dose reduction in the anthropomorphic phantom resulted in a linear loss of detectability. The same detectability as in conventional mammography was reached, however, by a dose reduction of about 50%. CONCLUSION: The results suggest that FFDM is at least equivalent to or--as far as spot views are concerned--superior to conventional SFM concerning the detectability of simulated lesions. Thus, a potential of dose reduction is suggested.

Breast Diseases↗

67Ga-citrate and 99Tcm-MDP for estimating the severity of vertebral osteomyelitis.

The aim of this study was to evaluate the roles of 67Ga-citrate and 99Tcm-methylene diphosphonate (99Tcm-MDP) planar and single photon emission tomographic (SPET) imaging in patients with vertebral osteomyelitis. Thirty patients (22 females, 8 males) aged 62.7 +/- 16.4 years (mean +/- s) were enrolled prospectively between May 1995 and May 1998. The patients had been on antibiotics for 7 +/- 4 weeks prior to the study. Histology was available for all but nine patients with mild infections, who were evaluated by a combination of magnetic resonance imaging (MRI), clinical and laboratory tests. 67Ga-citrate (185 MBq) and three-phase bone (555 MBq 99Tcm-MDP) planar and SPET imaging were performed in all patients, together with MRI as a comparison. In total, 67 infectious foci were detected. Based on histology, there were four cases of severe, 13 cases of moderate and four cases of mild osteomyelitis; nine mild infections were also classified by the combination of MRI, clinical and laboratory results. Combined MRI and 67Ga-citrate SPET correctly classified all patients; MRI detected all 67 infectious foci, whereas 67Ga-citrate SPET identified 54 only. False-negative results were seen with all other modalities, especially in cases of mild and moderate infection. 67Ga-citrate SPET identified unsuspected cases of endocarditis (n = 2), paravertebral abscess (n = 1), subaxillary soft tissue abscess (n = 1) and rib osteomyelitis (n = 1). For 67Ga-citrate SPET, the target-to-background ratio was 2.24 +/- 0.31, 1.76 +/- 0.07 and 1.30 +/- 0.18 for severe, moderate and mild osteomyelitis, respectively. Significant differences were noted between severe and moderate infection (P = 0.0051) and between severe and mild infection (P < 0.0001); that between moderate and mild infection was non-significant. For 99Tcm-MDP planar and SPET imaging, and for planar 67Ga-citrate imaging, there was no correlation with severity. We conclude that 67Ga-citrate SPET is able to identify vertebral osteomyelitis and detect additional sites of infection. It can also aid in determining the severity of infection and, potentially, the response to therapy.

Aged↗

Surface plasmon resonance biosensor studies of human wild-type and mutant lecithin cholesterol acyltransferase interactions with lipoproteins.

Binding of lecithin cholesterol acyltransferase (LCAT) to lipoprotein surfaces is a key step in the reverse cholesterol transport process, as the subsequent cholesterol esterification reaction drives the removal of cholesterol from tissues into plasma. In this study, the surface plasmon resonance method was used to investigate the binding kinetics and affinity of LCAT for lipoproteins. Reconstituted high-density lipoproteins (rHDL) containing apolipoprotein A-I or A-II, (apoA-I or apoA-II), low-density lipoproteins (LDL), and small unilamellar phosphatidylcholine vesicles, with biotin tags, were immobilized on biosensor chips containing streptavidin, and the binding kinetics of pure recombinant LCAT were examined as a function of LCAT concentration. In addition, three mutants of LCAT (T123I, N228K, and (Delta53-71) were examined in their interactions with LDL. For the wild-type LCAT, binding to all lipid surfaces had the same association rate constant, k(a), but different dissociation rate constants, k(d), that depended on the presence of apoA-I (k(d) decreased) and different lipids in LDL. Furthermore, increased ionic strength of the buffer decreased k(a) for the binding of LCAT to apoA-I rHDL. For the LCAT mutants, the Delta53-71 (lid-deletion mutant) exhibited no binding to LDL, while the LCAT-deficiency mutants (T123I and N228K) had nearly normal binding to LDL. In conclusion, the association of LCAT to lipoprotein surfaces is essentially independent of their composition but has a small electrostatic contribution, while dissociation of LCAT from lipoproteins is decreased due to the presence of apoA-I, suggesting protein-protein interactions. Also, the region of LCAT between residues 53 and 71 is essential for interfacial binding.

Apolipoprotein A-I↗

[Biphasic liver diagnosis with multiplanar-detector spiral CT].

PURPOSE: Scan protocol optimization and value of a multi-row-detector helical CT (MS-CT) in comparison to a single-row-detector spiral CT (SS-CT) for imaging of focal liver lesions. MATERIALS AND METHODS: The ability of a MS-CT with different scan parameters (slice thickness, scan mode, table-speed, reconstruction interval) for the detection of low-contrast objects was evaluated with a liver phantom and compared to a SS-CT. The clinical value (detection and characterization) of MS-CT with various slice thicknesses (3.75, 5, 7.5 mm) was compared intraindividually in 20 patients with a total of 43 benign and malignant lesions. RESULTS: In the experimental study the MS-CT reached the same detection rates for low-contrast objects despite a three-times faster scan-time compared to a SS-CT. The slice thicknesses of 3.75 and 5 mm proved to be optimal and were superior to a thickness of 7.5 mm for the detection and characterization of liver lesions. A distinct separation between arterial and portal venous phase was achieved by this protocol. CONCLUSION: The MS-CT allows a reliable acquisition of the entire liver parenchyma in defined perfusion phases. It improves the detection and characterization of focal liver lesions with optimized scan parameters with a significantly faster scan time than with the SS-CT.

Adult↗

[The diagnosis of acute aortic diseases with multiplanar-detector CT using the spiral technic].

UNLABELLED: Acute diseases of the central arteries require an immediate investigation. An efficient, fast and reliable diagnosis is necessary because of the high mortality, if the patient remains untreated. These requirements are perfectly fulfilled by the new CT-techniques. METHODS: Suspected aortic diseases were examined with a new multi-slice helical CT. The thoracic or the abdominal aorta as well as the entire vascular tree from the supra-aortic branches to the inguinal arteries were investigated with different CT protocols. The slice-thickness and the scan mode were changed while the total examination time was kept constant for the first two groups. In the third group a monophasic examination was compared to a biphasic one. RESULTS: In the diagnosis of acute aortic diseases multi-slice helical CT proved to be a fast and reliable method with all scan protocols. The objective measurements of contrast homogeneity and image quality were comparable in the first two groups. The monophasic contrast medium injection protocol was superior to the biphasic administration mode. CONCLUSIONS: Multi-slice helical CT appears to be a very effective approach for the diagnosis of acute aortic diseases and seems to be the new gold standard.

Acute Disease↗

MRI of the breast in patients with metastatic disease of unknown primary.

The objective of this study was to assess the value of contrast-enhanced dynamic breast imaging in patients with carcinoma of unknown primary (CUP). Fourteen patients presenting with metastatic disease compatible with breast cancer (axillary lymph node metastasis: n = 6; supraclavicular lymph node metastasis: n = 1; bone metastasis: n = 3; liver metastasis: n = 3; lung metastasis: n = 1), who had no evidence of tumor in X-ray mammograms and ultrasound, underwent bilateral dynamic breast MR imaging. Suspicious lesions were localized preoperatively using a stereotactic device for MR-guided localization procedures. Magnetic resonance imaging revealed suspicious lesions in 9 of 14 patients. Histopathology revealed invasive carcinoma of the breast in 6 of these patients. Two enhancing lesions were fibroadenomas; one proved to be sclerosing adenosis. In 5 patients MR imaging showed no abnormality. Follow-ups performed up to 1 year after initial treatment revealed no breast cancers in these 5 patients. In patients with metastatic disease of unknown primary, MRI of the breast depicts the primary in a considerable number of cases with normal conventional evaluation.

Adult↗

Unusual chondrosarcoma of the larynx: CT findings.

A case of a large low-grade mixed clear-cell and conventional chondrosarcoma of the larynx is reported involving the paraglottic space, the cricoid and thyroid cartilage and characterized by an unusual long clinical course over 22 years, although multiple recurrences occurred without developing metastases. Computed tomography suggests diagnosis by detecting calcifications and adequately demonstrates the extension of the tumor. Innersurface and surface-rendering images document the airway stenosis in all directions. The unusual feature of this case consists in the peculiar histopathological differentiation of the observed chondrosarcoma showing a large clear-cell component.

Chondrosarcoma↗