PubMed Health⌕ Search

Biomedical subjects

E Halpern

Publications and source records attributed to E Halpern.

At least 19 recordsLinked to original sources

Potential influence of acute CT on inpatient costs in patients with ischemic stroke.

RATIONALE AND OBJECTIVES: Patients presenting with ischemic brain symptoms have widely variable outcomes dependent to some degree on the pathologic basis of their stroke syndrome. The purpose of this study was to determine the cost implications of the emergency use of a computed tomographic (CT) protocol comprising unenhanced CT, head and neck CT angiography, and whole-brain CT perfusion. MATERIALS AND METHODS: By using a retrospective patient database from a tertiary care facility and publicly available cost data, the authors derived the potential savings from the use of CT angiography. CT perfusion, or both at hospital arrival by means of a cost model. The cost of the CT angiography-CT perfusion protocol was determined from Medicare reimbursement rates and compared with that of traditional imaging protocols. Cost savings were estimated as a decrease in the length of stay for most stroke patients, whereas the most benign (lacunar) strokes were assumed to be managed in a non-acute setting. Misdiagnosis cost (erroneously not admitting a patient with nonlacunar stroke) was calculated as the cost of a severe complication. Sensitivity testing included varying the percentage of misdiagnosed patients and admitting patients with lacunar stroke. RESULTS: The nationwide net savings that would result from the adoption of the CT angiography-CT perfusion protocol are in the $1.2 billion range (-$154 million to $2.1 billion) when patients with lacunar strokes are treated nonacutely and $1.8 billion when those patients are admitted for acute care. CONCLUSION: The results demonstrate the potential effect of implementing a CT angiography-CT perfusion protocol. In particular, prompt CT angiography-CT perfusion imaging could have an effect on the cost of acute care in the treatment of stroke.

Cerebral Angiography↗

Family psychology from an Israeli perspective.

A perspective of family psychology in Israel is drawn against a background of evolving indigenous elaboration suited to Israel's unique circumstances (J. I. Good & A. Ben-David, 1995). Its development shows a progression from the original source of an enriching but dominant culture (J. J. Gergen, A. Gulerce, A. Lock, & G. Misra, 1996; E. Halpern, 1985) to a discipline growing within the Israeli geopolitical reality, constraints of academic infrastructures, and training resources. One can currently recognize a discipline that is increasingly congruent with its cultural texture as well as the histories and traditions of individual families in a multifaceted society. This evolution is thought to bear similarities to the course that family therapy originally took and to where the roots of family psychology can be found. To echo F. W. Kaslow's (1987, 1991) analysis of this evolution in the United States, the heritage of family psychology in Israel also basically lies in mainstream psychology.

Family↗

Dual contrast enhanced magnetic resonance imaging of the liver with superparamagnetic iron oxide followed by gadolinium for lesion detection and characterization.

AIM: Iron oxide contrast agents are useful for lesion detection, and extracellular gadolinium chelates are advocated for lesion characterization. We undertook a study to determine if dual contrast enhanced liver imaging with sequential use of ferumoxides particles and gadolinium (Gd)-DTPA can be performed in the same imaging protocol. MATERIALS AND METHODS: Sixteen patients underwent dual contrast magnetic resonance imaging (MRI) of the liver for evaluation of known/suspected focal lesions which included, metastases (n = 5), hepatocellular carcinoma (HCC;n = 3), cholangiocharcinoma(n = 1) and focal nodular hyperplasia (FNH;n = 3). Pre- and post-iron oxide T1-weighted gradient recalled echo (GRE) and T2-weighted fast spin echo (FSE) sequences were obtained, followed by post-Gd-DTPA (0.1 mmol/kg) multi-phase dynamic T1-weighted out-of-phase GRE imaging. Images were analysed in a blinded fashion by three experts using a three-point scoring system for lesion conspicuity on pre- and post-iron oxide T1 images as well as for reader's confidence in characterizing liver lesions on post Gd-DTPA T1 images. RESULTS: No statistically significant difference in lesion conspicuity was observed on pre- and post-iron oxide T1-GRE images in this small study cohort. The presence of iron oxide did not appreciably diminish image quality of post-gadolinium sequences and did not prevent characterization of liver lesions. CONCLUSION: Our results suggest that characterization of focal liver lesion with Gd-enhanced liver MRI is still possible following iron oxide enhanced imaging.Kubaska, S.et al. (2001). Clinical Radiology, 56, 410-415

Adult↗

Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors?

PURPOSE: To study factors that may influence pneumothorax and chest tube placement rate, especially needle dwell time and pleural puncture angle. MATERIALS AND METHODS: In 159 patients, 160 coaxial computed tomography (CT)-guided lung biopsies were performed. Dwell time, the time between pleural puncture and needle removal, was calculated. The smallest angle of the needle with the pleura ("needle-pleural angle") was measured. These and other variables were correlated with pneumothorax and chest tube rates. RESULTS: One hundred fifty biopsies were included. There were 58 (39%) pneumothoraces (14 noted only at CT), with eight (5%) biopsies resulting in chest tube placement. Longer dwell times (mean, 29 minutes; range, 12-66 minutes) did not correlate with pneumothoraces (P =.81). Smaller needle-pleural angles (< 80 degrees) [corrected], decreased forced expiratory volume in 1 second to vital capacity ratio (<50%), lateral pleural puncture, and lesions along fissures were associated with higher [corrected] pneumothorax rates (P <.05). Emphysema along the needle path, pulmonary function tests showing ventilatory obstruction, and lesions along fissures predisposed patients to chest tube placement (P <.05). Pleural thickening and prior surgery were associated with lower pneumothorax rates (P <.05). CONCLUSION: Longer dwell times do not correlate with pneumothorax and should not influence the decision to obtain more biopsy samples. A shallow pleural puncture angle may increase the pneumothorax rate.

Aged↗

Schizophrenic subjects show aberrant fMRI activation of dorsolateral prefrontal cortex and basal ganglia during working memory performance.

BACKGROUND: Working memory (WM) deficits in schizophrenia have been associated with dorsolateral prefrontal cortex (DLPFC) dysfunction in neuroimaging studies. We previously found increased DLPFC activation in schizophrenic versus normal subjects during WM performance (Manoach et al 1999b). We now have investigated whether schizophrenic subjects recruit different brain regions, particularly the basal ganglia and thalamus, components of frontostriatal circuitry thought to mediate WM. METHODS: We examined regional brain activation in nine normal and nine schizophrenic subjects during WM performance using functional magnetic resonance imaging. Subjects performed a modified version of the Sternberg Item Recognition Paradigm that included a monetary reward for correct responses. We compared high and low WM load conditions to each other and to a non-WM baseline condition. We examined activation in both individual subjects and averaged group data. RESULTS: Relative to normal subjects, schizophrenic subjects exhibited deficient WM performance, at least an equal magnitude of right DLPFC activation, significantly greater left DLPFC activation, and increased spatial heterogeneity of DLPFC activation. Furthermore, only the schizophrenic group activated the basal ganglia and thalamus, even when matched for task performance with the normal group. CONCLUSIONS: Aberrant WM performance and brain activation in schizophrenia may reflect dysfunction of frontostriatal circuitry that subserves WM. Future studies will elucidate the contribution of the anatomical components of this circuitry to WM deficits.

Adult↗

Factor analysis of computerized and traditional tests used in mild brain injury research.

The present study examines the relation between a set of computerized neuropsychological measures, Automated Neuropsychological Assessment Metrics (ANAM), and a set of traditional clinical neuropsychological tests. Both sets of tests have been employed in recent studies of mild brain injury. Factor analysis and stepwise regression indicate that both sets of tests measure similar underlying constructs of cognitive processing speed, resistance to interference, and working memory. The present findings indicate strong concordance between computerized and traditional neuropsychological measures and support the construct validity of ANAM and similar procedures.

Adolescent↗

Helical CT protocols for the abdomen and pelvis: a survey.

OBJECTIVE: We surveyed members of the Society of Computed Body Tomography/Magnetic Resonance to evaluate current techniques used for helical CT in the abdomen and pelvis. MATERIALS AND METHODS: The survey was distributed to 70 members (36 institutions) of the Society of Computed Body Tomography/Magnetic Resonance. The survey included general questions related to abdominal and pelvic helical CT and also asked the members to write a protocol for 12 hypothetical requisitions. RESULTS: Thirty-two members (46%) responded, representing 28 institutions (78%). The number of protocols for helical CT of the abdomen and pelvis at each institution ranges from 2 to 35 (median, 11). IV contrast material is administered for 90% (median) of abdominal and pelvic CT examinations. Nonionic contrast material is used for 68% (median) of these examinations. IV contrast material is used by 100% of institutions for tumor staging protocols except for one institution that does not use IV contrast material for lymphoma staging. Fifty percent of the institutions obtain two- or three-phases of liver images for breast cancer staging. For all protocols, the average collimation and reconstruction interval is 7 mm except for renal (5 mm) and adrenal (4 mm) protocols. Rectal contrast material is administered most commonly for colon cancer staging (39% of institutions). CONCLUSION: There is a wide range in the number of protocols used for helical CT in the abdomen and pelvis among the responding institutions. Most protocols include use of nonionic IV contrast material injected at a rate of 3 ml/sec and a collimation of 7 mm.

Clinical Protocols↗

Schizophrenic subjects activate dorsolateral prefrontal cortex during a working memory task, as measured by fMRI.

BACKGROUND: Neuroimaging studies of schizophrenic subjects performing working memory (WM) tasks have demonstrated a relative hypoactivity of prefrontal cortex compared with normal subjects. METHODS: Using functional magnetic resonance imaging (fMRI), we compared dorsolateral prefrontal cortex (DLPFC) activation in 12 schizophrenic and 10 normal subjects during rewarded performance of a WM task. Subjects performed a modified version of the Sternberg Item Recognition Paradigm (SIRP), a continuous performance, choice reaction time (RT) task that requires WM. We compared a high WM load condition with a nonWM choice RT condition and with a low WM load condition. RESULTS: Schizophrenic subjects performed the tasks better than chance but worse than normal subjects. They showed greater activation than normal subjects in the left DLPFC but did not differ in the right DLPFC or in the control region. In the schizophrenic group, left DLPFC activation was inversely correlated with task performance, as measured by errors. CONCLUSIONS: These findings contrast with previous studies that demonstrated task-related hypofrontality in schizophrenia. Task parameters that may contribute to this difference are discussed. We hypothesize that the performance and activation differences we observed are also manifestations of prefrontal dysfunction in schizophrenia. They reflect inefficient functioning of the neural circuitry involved in WM.

Adult↗

Breast cancer: computer simulation method for estimating optimal intervals for screening.

PURPOSE: To develop and evaluate a mathematic method that can be used to determine the optimal screening interval for detection of breast cancer prior to distant metastatic spread. MATERIALS AND METHODS: A computer simulation was developed with the use of biologically based data from the literature on the rates of tumor growth and spread, which can be used to calculate the course of breast cancer growth and metastasis. RESULTS: On the basis of the data available at this time, the results of the simulations suggested that a screening interval of 2 years would result in a 22% reduction in the rate of distant metastatic disease, an interval of 1 year would result in a 51% reduction, and an interval of 6 months would result in an 80% reduction. CONCLUSION: These findings suggest that more frequent screening could dramatically reduce the death rate from breast cancer.

Appointments and Schedules↗

Simian immunodeficiency virus encephalitis in rhesus macaques is associated with rapid disease progression.

Central nervous system (CNS) disease is a major feature of simian immunodeficiency virus (SIV) infection of macaques. To define the spectrum of CNS lesions in SIV-infected macaques and the potential associations with viral strain and disease course, we performed a retrospective analysis of necropsies on 124 macaques with SIV-induced AIDS. Histologic evidence of CNS disease was observed in 71 (57.3%) of the 124 animals. SIV encephalitis was the most common CNS lesion occurring in 43.7% (31/71) of the animals with CNS disease and 25% of all animals. The incidence of SIVE correlated significantly with shortened survival (P=0.0207). In addition, SIVE was seen in 42.9% (15/35) of rapid progressors (animals that died within 200 days) compared to only 18% (16/89) of normal progressors (animals that lived longer than 200 days) (P=0.011). Animals with SIVE had higher viral loads in peripheral blood than those that did not, but this difference did not reach statistical significance. Similarly, while animals infected with uncloned SIVmac251 had a higher incidence of SIVE (27.5%; 14/51) than animals infected with molecularly cloned SIVmac239 and its T-cell tropic derivatives (18.5%; 10/54) this difference was not statistically significant. In this study rapid disease progression and SIVE were highly correlated making separation of viral determinants of virulence from those of neurovirulence difficult.

Animals↗

Liver metastases: improved detection with dynamic gadolinium-enhanced MR imaging?

PURPOSE: To compare dynamic gadolinium-enhanced with unenhanced magnetic resonance (MR) imaging in detection of liver metastases. MATERIALS AND METHODS: Two groups of patients were prospectively examined with unenhanced and dynamic gadolinium-enhanced MR imaging. The first group (n = 48) had proved liver metastases; the second group (n = 49) did not. One set of unenhanced and one set of gadolinium-enhanced MR images were selected per patient. Three independent, blinded readers assessed the images for presence, number, location, and conspicuity of lesions. Data were analyzed with receiver operating characteristic curves, and contrast-to-noise ratios were calculated for the images. RESULTS: There was no statistically significant difference between the use of unenhanced and gadolinium-enhanced MR images in the differentiation of patients with from patients without metastases. The numbers of false-positive and false-negative diagnoses of individual lesions were higher (not statistically significant) with dynamic MR images than with unenhanced MR images. At dynamic MR imaging, contrast-to-noise ratio was highest in the early phase (30 seconds after injection of the contrast agent) but was not significantly different from the contrast-to noise ratio of the T2-weighted images. CONCLUSION: Dynamic gadolinium-enhanced MR imaging showed no improvement over unenhanced MR imaging in detectability of liver metastases.

Adult↗

Poly(ethylene glycol)-coated anti-cardiac myosin immunoliposomes: factors influencing targeted accumulation in the infarcted myocardium.

Biodistribution and infarct accumulation of different liposome preparations in rabbits with experimental myocardial infarction have been investigated. The influence of such parameters as liposome size, and presence or absence of poly(ethylene glycol) (PEG) and infarct-specific antimyosin antibody (AM) on liposome behavior in vivo was studied. All three variables were shown to affect liposome biodistribution, liposome size being the least significant variable. Statistical analysis of the data obtained demonstrated that of all variables, PEG coating expresses the strongest influence on the liposome blood clearance, significantly (P=0.0001) increasing the mean level of blood radioactivity under all circumstances. Infarct accumulation depended upon the presence of both PEG (P=0.0013) and AM (P=0.005). The infarct-to-normal ratio was affected by the presence of AM (P=0.0002), but the extent of the effect depended also on the presence of PEG (P=0.01). Two differing mechanisms can be seen in infarct accumulation of PEG-liposomes (slow accumulation via the impaired filtration) and AM-liposomes (specific binding of immunoliposomes with the exposed antigen). Both mechanisms are supplementary in case of liposomes carrying PEG and AM at the same time. An optimization strategy is suggested for using liposomes as carriers for diagnostic (a high target-to-nontarget ratio is required) and therapeutic (a high absolute accumulation in the target is required) agents.

Animals↗

Continuous assessment of relative cerebral blood volume in transient ischemia using steady state susceptibility-contrast MRI.

The utility of a noninvasive steady state susceptibility-contrast MRI technique for continuous measurement of relative cerebral blood volume (rCBV) during global transient ischemia and subsequent hyperemia in a feline ischemia model is demonstrated. The measurements were obtained during a 10-min period of occlusion and 1-h period of reperfusion. Maximal hyperemic responses in gray matter, basal ganglia, and white matter (observed at 7,7, and 5 min, respectively) were 1.9 +/- 0.5, 1.8 +/- 0.3, and 1.7 +/- 0.6 times greater than baseline CBV (mean +/- SEM). Thirty to forty minutes after onset of reperfusion, CBV returned to normal. Thereafter, it decreased below baseline, nearing the control level by 1 h after onset of reperfusion. Steady state susceptibility-contrast MRI permits continuous, in vivo mapping of alterations in CBV.

Animals↗

Time-lapse quantitative computed tomography lymphography: assessing lymphatic function in vivo.

RATIONALE AND OBJECTIVES: Immobility and massage produce different local limb lymph flow rates. We studied their influence on accumulation of radiopaque nanoparticulates in regional lymph nodes of normal rabbits. METHODS: Quantitative lymphography at 10-min intervals was used to follow the transport of subcutaneous (s.c.) nanoparticulates produced from insoluble esters of diatrizoic acid. In one design, both hindpaws received 0.5 ml of nanoparticulate s.c., and one hindpaw was massaged. In a second design, one hindpaw was injected and massaged while imaging the popliteal, presacral, and paraaortic nodes every 10 min. RESULTS: Gentle massage rapidly increased popliteal node accumulation in comparison with the immobile limb. On the massaged side, mean Hounsfield (HU) units, maximum Hounsfield units, and calculated iodine were significantly greater at 10 min and all subsequent times. In the node transfer experiments, it took 12, 30, and 45 min, respectively, to obtain 100-HU mean attenuation; 200-HU maximum attenuation thresholds were achieved at 20, 47, and 69 min, respectively. CONCLUSION: Quantitative computed tomography lymphography reflects local lymph physiology. Gentle massage of the s.c. injection site is a powerful lymphotropic stimulus.

Analysis of Variance↗

T2-weighted MR imaging of the upper part of the abdomen: should fat suppression be used routinely?

OBJECTIVE: Fat suppression has shown promise in improving the quality of T2-weighted spin-echo MR images of the upper part of the abdomen. The purpose of this study was to determine whether fat-suppressed images should be routinely used in lieu of conventional images. Accordingly, we prospectively compared the two techniques in a series of patients with both normal and abnormal findings in the upper part of the abdomen. MATERIALS AND METHODS: Conventional and fat-suppressed T2-weighted spin-echo images (3000/80,160 [TR/TE]) were obtained in 45 consecutive patients referred for MR imaging of the upper part of the abdomen. Thirty-three patients had abnormal findings, and 22 of those 33 patients had histologic or follow-up confirmation of the diagnosis (14 with metastasis, one with hepatoma, four with hemangiomas, and three with cysts). Signal intensities (hepatic lesions, liver, spleen) and noise were measured to calculate signal-to-noise ratios and contrast-to-noise ratios. Qualitative comparison (liver, hepatic lesions, porta hepatis, spleen, pancreas, bowel, kidneys, adrenal glands, noise), evaluation of the number of hepatic lesions, and characterization of hepatic lesions were done by independent observers. RESULTS: Compared with conventional images, fat-suppressed images had higher signal-to-noise ratios (lesions, liver, spleen) and contrast-to-noise ratios (lesion-liver and spleen-liver) (p < .005). In qualitative comparison, three of three radiologists preferred fat-suppressed over conventional images for depiction of hepatic lesions and all upper abdominal organs except the liver, for which no clear preference was shown for either technique. Detection rates for hepatic lesions were similar with both types of images (observer 1: 112 lesions on fat-suppressed vs 118 on conventional images, observer 2: 142 vs 135), as was the characterization of hepatic lesions (91% accuracy on fat-suppressed images and 84% accuracy on conventional images, for 22 proved lesions and two observers). CONCLUSION: Fat-suppressed T2-weighted spin-echo MR images were better than non-fat-suppressed images for evaluation of the upper part of the abdomen. These results suggest that fat suppression should be routinely used in T2-weighted MR imaging of the upper part of the abdomen.

Abdomen↗