Evaluation of a cinevideodensitometric method for measuring vessel dimensions from digitized angiograms.

A cinevideodensitometric method for measuring the dimensions of small vessels by computer analysis of digitized cineangiograms was developed and validated in radiographic phantom models. With this method, which is based on full-width-at-half-maximum analysis of videodensitometric profile curves, the diameters of contrast-filled plexiglass cylinders ranging from 1.78 mm to 4.14 mm in diameter were measured to within 2% mean error. The theoretical basis for this method of cinevideodensitometric analysis is provided.

Angiography↗

Radionuclide administration to nursing mothers: mathematically derived guidelines.

We determined a formula to establish objective guidelines for the administration of radionuclides to nursing mothers. The formula is based on the maximum permissible dose to the infant's critical organ, serial measurements of breast milk activity, milk volume, and dose to the critical organ per microcurie in milk. Using worst-case assumptions, we believe that cessation of nursing for 24 hours after administration of technetium labeled radiopharmaceuticals is sufficient for safety. Longer-lived agents require greater delays. Iodine-123 radiopharmaceuticals are preferable to iodine-131 agents and should always be used when studying the unblocked thyroid.

Animals↗

Effect of coronary stenotic lesions on regional myocardial blood flow at rest.

To determine the effect of atherosclerotic coronary lesions on myocardial blood flow in patients at rest, regional myocardial blood flow was measured distal to stenotic lesions in 29 patients with isolated proximal lesions of the left anterior descending artery. Severity of coronary stenosis was measured by computer-assisted cinevideodensitometric analysis of digitized coronary arteriograms. Regional myocardial blood flow was measured from the clearance rate of intracoronary 133Xe injected into the left main coronary artery and recorded with a multicrystal scintillation camera. In 21 patients with stenotic lesions ranging from 19% to 84% area reduction, distal regional myocardial blood flow was normal. In all eight patients with reduced regional myocardial blood flow distal to left anterior descending lesions, the minimum area of each stenotic lesion was less 0.80 mm2 (mean 0.34 +/- 0.2 mm2), minimum calculated diameter was less than 1 mm (mean 0.59 +/- 0.3 mm), and percent stenosis, based on the reduction in cross-sectional area, was greater than 85% (mean 94 +/- 4%). For all patients, distal flow, expressed as a fraction of normal flow, correlated with the lesion cross-sectional area (r = .84), minimum luminal diameter (r = .84), and percent area stenosis (r = -.70). Thus, resting myocardial blood flow distal to stenotic lesions of the proximal coronary arteries remains normal until the degree of narrowing is severe. The dimensions observed for critical coronary stenotic lesions correlate well with theoretical predictions based on fluid mechanics and with experimental preparations in laboratory animals.

Cineangiography↗

Normal thermographic standards for the cervical spine and upper extremities.

Although thermography has been used for a variety of abnormal conditions, extensive data on large, relatively asymptomatic populations has heretofore not been available. More specifically, no data deal with the upper extremities and, more particularly, no analyses are based on simultaneous thermograms of the posterior neck and shoulders. The current study undertook this task. The results confirm the existence of thermal symmetry in the overwhelming majority of 100 normal relatively asymptomatic, actively employed factory workers. Conversely, if persistent, statistically significant thermal asymmetry exists, as outlined and correlates with patient symptomatology, an organic basis for it should be sought.

Adolescent↗

A radioimmunoassay for total captopril in human serum or plasma samples.

A radioimmunoassay for the measurement of total captopril in serum and heparinized plasma has been developed. Prior to the assay, serum or heparinized plasma samples are subjected to tri-n-butyl-phosphine reduction followed by N-ethylmaleimide (NEM) derivatization. The assay utilizes in-house NEM-captopril antibody, [125I]NEM-captopril radiolabel and human serum standards. Satisfactory zero binding and sensitivity are obtained after 3 h of incubation at room temperature. Separation of the antibody-bound and free radiolabeled antigen is achieved by employing a polyethylene glycol solution. The assay was shown to have excellent parallelism, recovery, and precision. Cross-reactivities with potentially interfering substances were low.

Captopril↗

Left ventricular volume: physical basis for attenuation corrections in radionuclide determinations.

Absolute left ventricular volume has been calculated from gated blood pool studies by estimating an attenuation correction for left ventricular counts. We studied the physical basis of these corrections by evaluating x-ray photon attenuation from CT scans of the thorax (10 second scans, no gating). CT numbers were converted to linear attenuation coefficients (LACs) at 140 keV, and LACs from the center of the left ventricle or esophagus to the chest wall (40 degrees left anterior oblique position) were determined in 12 patients of various body habitus. The mean LACs were virtually identical (0.13 cm-1 +/- 0.02 cm-1 SD), but were less than the LAC of water (0.15 cm-1). However, the esophagus was 66% further from the chest wall than the center of the left ventricle. These results suggest that conventional methods overestimate attenuation and show that LAC variability between individuals can be large. Better methods of attenuation correction may improve count-based estimates of left ventricular volume.

Adult↗

Interference in immunoassay.

With the proliferation of immunoassays used in the clinical laboratory, we have come to realize that there are many factors which can interfere with these assays. Some of these, like exogenous radioactivity, will only interfere with one type of immunoassay--the radioimmunoassay. Other interferences will affect all types of immunoassays, although perhaps to differing degrees. This article will survey some of the more common types of interfering substances which may affect immunoassays, including tube types, serum factors, and the interferences which are specifically due to the type of label used in the assay.

Antibodies↗

The role of 99mTc pertechnetate uptake in the evaluation of thyroid function.

To investigate the usefulness of the 20 min 99mTc-pertechnetate uptake test, the records of 246 consecutive patients were reviewed. Of these, 192 patients (151 females, 41 males; 10 weeks to 78 years) had at least one year clinical follow-up or a confirmed diagnosis by biopsy or surgery and were included in our study. In these patients, the 99mTc pertechnetate uptake and hormonal values (T3 resin uptake, T4 RIA, T-index) were obtained. These results were then compared to the clinical diagnosis at the time of the uptake and one year later. All patients received an i.v. injection of 5 mCi of 99mTc pertechnetate. Imaging was performed using a pinhole collimator and a scintillation camera interfaced to a computer. Regions of interest for the thyroid and the background were used to calculate the 20 min 99mTc pertechnetate uptake as a percentage of the injected dose. 99mTc uptake and hormonal values were confirmatory in 158 patients (82.3%): 138 were euthyroid, 18 were hyperthyroid and 2 were hypothyroid. In 29 other patients (15.1%) the pertechnetate uptake provided useful additional information and helped to identify Hashimoto's thyroiditis (8 patients); thyroid suppression by exogenous iodide, steroids or T4 (7 patients); overtreated hyperthyroidism (1 patient); persistent hyperthyroidism (5 patients); different stages of Grave's disease (4 patients); and toxic nodular goiter (4 patients). The 99mTc uptake was misleading in 5 euthyroid patients (2.6%). We have found the 99mTc pertechnetate uptake a useful adjunct to measurement of hormonal levels in patients with suspected thyroid disease.

Adolescent↗

Human platelets labeled with In-111 8-hydroxyquinoline: kinetics, distribution, and estimates of radiation dose.

Platelets from nine normal male subjects were labeled with In-111 8-hydroxyquinoline (In-111 oxine) in the presence of plasma in either "closed" blood transfer packs or in "open" test tubes. The mean labeling efficiencies in these two systems were 27 and 53%, respectively. Mean survival time of In-111-labeled autologous platelets was 8.76 days, with a standard deviation of 1.05 according to the maximum-likelihood estimate of the gamma-function model. The initial recovery of In-111 platelets in the circulation was 57% with a standard deviation of 11%. The distribution of In-111 platelets in liver and spleen was quantitated by anterior, posterior, and transmission gamma-camera imaging. During the first 30 min, 38% of the injected dose accumulated in the spleen, 13% in the liver. No significant increase in In-111 radioactivity was observed in either of the two organs over a 3-9-day period. The bone marrow was an additional site of In-111 accumulation. The spleen was the critical organ with respect to radiation dose. The splenic dose was estimated to be 34 rad/mCi In-111 platelets, that of the liver 2.1 rad/mCi. With the injection of 100-150 microCi of In-111-labeled platelets in normal subjects, giving a splenic radiation of 5 rad, a complete 10-day survival study can be performed and uptake of In-111 in different organs can be measured quantitatively for at least 3-4 days.

Adult↗

Temporal resolution requirements for left ventricular time-activity curves.

To investigate framing rate requirements for left ventricular (LV) time-activity curves, ECG-synchronized blood pool studies of 33 patients were compared to independent techniques for evaluation of LV function. There were no significant differences in LV ejection fractions determined using different framing rates. Systolic time intervals calculated from 64- and 32-point curves were similar and correlated well with those obtained by standard methods (r = 0.81, p less than 0.001). Results from 16-point curves were worse (p less than 0.02). There were no differences between peak ejection and filling rates obtained with 64- and 32-point curves compared to angiography, but the rates calculated using 16-point curves were significantly slower (p less than 0.05). The findings suggest that LV time-activity curves acquired at 16 frames per RR interval do not provide optimum quantification of LV function indexes other than the ejection fraction.

Electrocardiography↗

Blood gastrin levels in hyperthyroidism.

Serum gastrin concentrations were measured in 22 untreated and 10 treated thyrotoxic patients. In contrast to similar studies carried out in Japan, serum gastrin levels were normal in hyperthyroid subjects. The mean value in hyperthyroid subjects (94.8 +/- 34.5 pg/ml) was higher than that in the treated patients (73.6 +/- 33.2 pg/ml), but the difference was not significant (P greater than 0.05).

Adult↗

A study of age-dependent changes in thyroid function tests in adults.

Total serum thyroxine (T4), triiodothyronine (T3), T3 resin uptake (T3U), thyrotrophin (TSH), and reverse T3 (rT3) were measured in 209 healthy adults 20--89 yr old. Mean T4 values for men were stable throughout life, but in females under age 60, T4 values were significantly higher than in older women. Values for T3U in males were significantly higher than in females throughout all decades, although females had a significant increase in T3U after age 60. TSH values increased significantly in females over age 60. Throughout all decades, males had stable TSH levels that were slightly higher than the female results before age 60 and lower thereafter. Mean serum T3 declined similarly for both sexes with increasing age, although not to the extent previously reported. Men had significantly higher mean rT3 values over all decades than females, although female rT3 levels decreased after age 50 whereas males maintained stable values. The physiologic reasons for these findings may be due to sex-related changes in binding proteins and alterations in metabolic clearance rates, production, and degradation of these hormones with increasing age.

Adult↗

A comparison of five methods for monitoring the precision of automated x-ray film processors.

Five different methods for preparing sensitometric strips used to monitor the precision of automated film processors are compared. A method for determining the sensitivity of each system to processor variations is presented; the observed statistical variability is multiplied by the system response to temperature or chemical changes. Pre-exposed sensitometric strips required the use of accurate densitometers and stringent control limits to be effective. X-ray exposed sensitometric strips demonstrated large variations in the x-ray output (2 omega approximately equal to 8.0%) over a period of one month. Some light sensitometers were capable of detecting +/- 1.0 degrees F (+/- 0.6 degrees C) variations in developer temperature in the processor and/or about 10.0 ml of chemical contamination in the processor. Nevertheless, even the light sensitometers were susceptible to problems, e.g. film emulsion selection, line voltage variations, and latent image fading. Advantages and disadvantages of the various sensitometric methods are discussed.

Automation↗

Tc-99m human serum albumin: a suitable agent for plasma volume measurements in man.

In 16 patients we have carried out simultaneous plasma-volume measurements with human serum albumins tagged with Tc-99m (Tc-99m HSA) and I-131 (I-131 HSA). The correlation coefficient was 0.987. Tc-99m HSA, prepared from kits that predictably yield high labeling efficiency (and thereby negligible amounts of TCO4-), is clearly a superior agent for repeat plasma volume determinations, because of its shorter half-life and the reduced radiation dose to the subject.

Humans↗