Radiographic detail and variation of the nominal focal spot size: the "focal effect".

It is not generally appreciated that there is a gradation of the focal spot size from the anode to cathode end of an x-ray field that can dramatically affect radiographic detail from one end of a radiograph to the other. The authors name this gradation the "focal effect." Gradations in radiation intensity and focal spot size were measured from anode end to cathode end of a 14 x 17-inch field and were visually demonstrated with lymphangiograms and line-pair patterns. The degradation in spatial resolution along the anode-cathode axis was found to be as much as 75%, depending on the orientation of the patient with respect to the x-ray tube. Radiographic detail is, therefore, significantly improved (even when the large focal spot is used) by exploiting the focal effect and placing the body part requiring the best radiographic detail at the anode end of the table.

Contrast Media

Technologic advances in diagnostic radiology.

Technologic advances in radiographic equipment and procedures for four different areas of diagnostic radiology are reviewed: bone mineral assessments, musculoskeletal imaging, mammography, and chest imaging. For bone mineral assessments the accuracy and precision obtained using single- and dual-energy photon absorptiometry, dual-energy x-ray absorptiometry, and quantitative CT are summarized. Various digital systems employed in musculoskeletal imaging are reviewed. In mammography, papers related to accreditation and research interests are highlighted. The use of photo-simulated phosphor plates and scanned equalization radiographic systems for chest imaging are discussed. Finally advances in radiographic film processing are noted.

Bone Density

A quality-control phantom for digitization of radiographs.

Quality control is fundamental to the clinical application of digital radiography. A 14 x 17-in phantom radiograph was designed to test digital image quality by measurement of five parameters: high-contrast spatial resolution, low-contrast discrimination, linearity of gray-scale response, high-frequency noise, and geometric distortion. The phantom was used to evaluate the AT&T-Philips CommView picture archival and communications system (AT&T Bell Laboratories, West Long Branch, NJ; Philips Medical Systems, Shelton, CT). High-contrast resolution was found to be greater along the diagonal axis of the system than along either the horizontal or vertical axis. Problems with low-contrast discrimination and linearity of gray-scale response were identified. This phantom provides a simple tool for daily quality assurance testing and an objective standard for comparison of image quality between different digital radiography systems.

Quality Control

A study of age-dependent changes in thyroid function tests in adults.

Total serum thyroxine (T4), triiodothyronine (T3), T3 resin uptake (T3U), thyrotrophin (TSH), and reverse T3 (rT3) were measured in 209 healthy adults 20--89 yr old. Mean T4 values for men were stable throughout life, but in females under age 60, T4 values were significantly higher than in older women. Values for T3U in males were significantly higher than in females throughout all decades, although females had a significant increase in T3U after age 60. TSH values increased significantly in females over age 60. Throughout all decades, males had stable TSH levels that were slightly higher than the female results before age 60 and lower thereafter. Mean serum T3 declined similarly for both sexes with increasing age, although not to the extent previously reported. Men had significantly higher mean rT3 values over all decades than females, although female rT3 levels decreased after age 50 whereas males maintained stable values. The physiologic reasons for these findings may be due to sex-related changes in binding proteins and alterations in metabolic clearance rates, production, and degradation of these hormones with increasing age.

Adult

A comparison of five methods for monitoring the precision of automated x-ray film processors.

Five different methods for preparing sensitometric strips used to monitor the precision of automated film processors are compared. A method for determining the sensitivity of each system to processor variations is presented; the observed statistical variability is multiplied by the system response to temperature or chemical changes. Pre-exposed sensitometric strips required the use of accurate densitometers and stringent control limits to be effective. X-ray exposed sensitometric strips demonstrated large variations in the x-ray output (2 omega approximately equal to 8.0%) over a period of one month. Some light sensitometers were capable of detecting +/- 1.0 degrees F (+/- 0.6 degrees C) variations in developer temperature in the processor and/or about 10.0 ml of chemical contamination in the processor. Nevertheless, even the light sensitometers were susceptible to problems, e.g. film emulsion selection, line voltage variations, and latent image fading. Advantages and disadvantages of the various sensitometric methods are discussed.

Automation

Tc-99m human serum albumin: a suitable agent for plasma volume measurements in man.

In 16 patients we have carried out simultaneous plasma-volume measurements with human serum albumins tagged with Tc-99m (Tc-99m HSA) and I-131 (I-131 HSA). The correlation coefficient was 0.987. Tc-99m HSA, prepared from kits that predictably yield high labeling efficiency (and thereby negligible amounts of TCO4-), is clearly a superior agent for repeat plasma volume determinations, because of its shorter half-life and the reduced radiation dose to the subject.

Humans

Mammographic resolution: influence of focal spot intensity distribution and geometry.

The influence of focal spot intensity distribution and geometry upon mammographic image quality were evaluated. The modulation transfer functions (MTF's) for eight different intensity distributions were determined and plotted in a manner to eliminate the effects of magnification and focal spot dimension. The results indicated that the total cross-sectional area is important for focal spots with uniform intensity distributions and equivalent diameters. For equivalent focal spot dimensions, intensity distributions with edge bands were shown to have less spatial resolution than uniform intensity distributions. Focal spots with greater intensities towards their centers provided better resolution than either uniform intensity distributions or distributions with edge bands for equivalent sizes. The type of intensity distribution was also shown to affect the accuracy of star pattern measurements of focal spot size; this method of measurement is only precise for a uniform square intensity distribution. Errors obtained with several other intensity distributions were tabulated. The variations of the effective focal spot size with position along the anode-cathode axis were shown to be of a factor of approximately two to three. The combined effects of geometric blur and film/screen blur were present for various heights above the cassette tray on several different mammographic systems.

Female