PubMed Health⌕ Search

Biomedical subjects

E Martuscelli

Publications and source records attributed to E Martuscelli.

At least 37 records · Page 2Linked to original sources

Characterization and long-term prognosis of patients with effort-induced silent myocardial ischaemia.

The aim of this study was to evaluate the anatomo-clinical correlations and the prognostic significance of silent myocardial ischaemia (SI) during exercise testing (ET). Four hundred and six patients with angiographically proven CAD and positive ET were studied. Patients were divided into two groups: 309 patients (Group A) with positive ET for both electrocardiographical findings and angina, and 97 patients (Group B) with positive ET for electrocardiographical findings but not for angina (SI). In Group A the following clinical characteristics differed significantly from Group B: incidence of diabetes mellitus (15.8% vs 27.8%, P less than 0.04); duration of disease (less than 1 month from its first manifestation) (30.4% vs 54.6%, P less than 0.001) and a positive ET at low work-load (41.7% vs 50.5%, P less than 0.05). Mortality during follow-up (mean 72 +/- 11 months) was 8.6% in Group A and 8.2% in Group B (NS). Incidence of sudden death was similar in the two groups (2.9% vs 2.06%; NS). The multivariate analysis shown as independent variables, related significantly with a poor prognosis in both groups: left ventricular function (P less than 0.0001); prior myocardial infarction (P less than 0.0001); and multivessel disease (P less than 0.001). In conclusion, patients with a recent onset of symptoms, a positive ET at low workload and diabetes mellitus are more likely to present SI during ET. The long-term prognosis and the incidence of sudden death are similar in patients with painful and painless myocardial ischaemia during ET.

Angina Pectoris↗

[THe surgical treatment of aneurysmatic lesions of the ascending aorta: the immediate and long-term results in 40 patients].

From January 1981 to January 1991, 40 patients underwent operation for acute ascending aorta dissection (AAD, 14 patients), chronic ascending aorta dissection (CAD, 9 patients) or aortic ectasia (AE, 17 patients), with simultaneous aortic valve replacement in 30 cases (75%). Average age was 54 years with a 3:1 M/F ratio. In 20 cases (50%) a composite graft bearing a mechanical bileaflet valve was inserted with coronary artery reattachment (Bentall operation). In 16 cases (40%) the ascending aorta was replaced by a woven dacron graft alone (7 cases) or associated with aortic valve substitution (7 cases) or resuspension (2 cases). In 1 case (2.5%) a sutureless ring graft replacement of ascending aorta was carried out and 3 patients (7.5%) underwent aortoplasty with aortic valve substitution. Postoperative mortality rate was 21% for AAD group, 11% for CAD group and 6% for AE group. Non-fatal postoperative complications developed in 36% of AAD patients and in 78% and 29% of CAD and AE patients respectively. These complications occurred in 45% of patients who underwent Bentall operation, in 44% of those who underwent ascending aorta replacement associated with aortic substitution or resuspension, and in 14% of those operated of simple ascending aorta replacement. Average follow-up was 41.6 months (range 1.7-107.4 months). During this period 5 deaths occurred for a long-term mortality rate of 14.2%. Out of 30 survivors 21 (70%) underwent CT-study to evaluate the natural course of the false channel and the risk of redissection or late aneurysm formation.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Hypertrophic cardiomyopathy: is a left ventricular outflow tract gradient a major prognostic determinant?

The relationship of left ventricular outflow tract gradient as well as of clinical, ECG and haemodynamic data to presenting features and prognosis was evaluated in 125 consecutive patients with hypertropic cardiomyopathy, 79 men and 46 women (mean age: 34 +/- 7 years) studied between January 1970 and December 1985. Most clinical, ECG and haemodynamic findings were similar in the 44 patients (35%) with a pressure gradient (greater than or equal to 30 mmHg) and in the 81 patients (65%) without. Those with obstruction had greater ECG voltage SV1 and RV5; however, higher grade ventricular arrhythmias were more common in patients without obstruction. During a mean follow-up period of 7.6 +/- 4.5 years (range 2-18 years), death from a cardiac cause occurred in 28 patients (21 died suddenly) and was significantly less common in patients with a pressure gradient than in those without (11% vs 28%, P = 0.039). Univariate analysis of survival curves showed that the most powerful predictors of a poor prognosis were ejection fraction P = 0.0001), mean pulmonary artery pressure (P = 0.0001), dyspnoea (P = 0.001), left ventricular end-diastolic pressure (P = 0.002), complex ventricular arrhythmias (P = 0.029) and severe mitral regurgitation (P = 0.037). Using multivariate analysis, a decreased ejection fraction (P = 0.006) and a raised mean pulmonary artery pressure (P = 0.022) were the only independent prognostic determinants. Thus, the presence of a left ventricular outflow tract gradient does not seem of adverse prognostic significance. Risk factor characterization in patients with hypertrophic cardiomyopathy may be improved by assessment of ventricular arrhythmias in the context of left ventricular function.

Adolescent↗

[Winging effect in interatrial defect after transseptal mitral valvuloplasty: an anatomical study].

In the balloon catheters the redundancy of the deflated balloon produces 2 or 3 sort of thin wings. The presence of wings can reduce the catheter "pushability" or, in certain conditions, can determine tissue lesion (winging effect). Simulating a transeptal valvuloplasty of the mitral valve by technique of the 2 balloon in human fresh heart, we studied the winging effect over the interatrial septum in 12 hearts; in the first 6 the atrial septum was dilated with a 6 mm balloon (Group A), in the second 6 the atrial septum was dilated with a 10 mm balloon (Group B). The procedure was completed introducing consecutively 2 bigger balloons (15 + 20 mm). We suppose that the winging effect of the 2 bigger balloons (15 + 20 mm) could counter balance the theoretical advantage of a small balloon (6 mm). The atrial septal defect (ASD) after septal dilatation was 5.0 +/- 0.59 mm x 1.56 +/- 0.25 mm (long axis x short axis) in Group A and 6.53 +/- 0.35 x 2.16 +/- 0.39 mm in Group B (p less than 0.01). The final ASD (after introducing the 2 bigger balloons) was 7.04 +/- 1.06 x 2.36 +/- 0.57 mm in Group A and 7.03 +/- 0.18 x 2.16 +/- 0.32 mm in Group B (NS). Our data show that the winging effect can determine biological negative effects.

Catheterization↗

Hemodynamic and clinical effects of captopril in patients with severe congestive heart failure.

In a group of 10 patients (9 male, 1 female, aged 16 to 56, mean 43 years) with severe congestive heart failure (CHF), due to ischemic heart disease (8 cases) or dilatative cardiomyopathy (2 cases), the acute hemodynamic response to captopril (CPT) (90 min after 50 mg po) was evaluated. CPT was then given starting with 15 mg q 8 hr, gradually increased within 2 or 3 days to 50 or 75 mg q 8 hr. A hemodynamic re-evaluation was performed after 20 days, and, in 5 patients, after 1 year of CPT treatment. The clinical follow-up done every 3 months in the outpatient clinic. CPT acutely produced a decrease in mean pulmonary wedge pressure: 23.8 +/- 8.9 to 18.6 +/- 8.6 mmHg, p less than 0.01, and an increase in cardiac index: 2.43 +/- 0.73 to 2.91 +/- 0.85 l/min/m2, p less than 0.01; systemic and pulmonary resistances decreased significantly, with no significant changes in heart rate and in mean brachial artery pressure. This favourable hemodynamic response persisted after 20 days of CPT treatment. In the group of 5 patients, who underwent a third hemodynamic evaluation, no statistically significant differences were demonstrated in respect to the previous control values. All patients on chronic CPT treatment experienced a gradual clinical improvement, reaching a steady state after 2 to 3 weeks; the surviving patients remained stable in the improved functional class for at least 6 months. The mortality rate was 30% in the first year, increasing to 50% in the second and to 60% in the third year of treatment. After a mean follow-up 35.7 months (range 33 to 39) the 4 surviving patients remained in the same functional class as after the first year for therapy. In our CHF patients CPT improved the quality of life, with the best clinical and hemodynamic results the first few months of treatment; life expectancy probably was not affected.

Adolescent↗

[Reliability of the ejection fraction determined with the nuclear stethoscope. Comparison with angiocardiography].

The purpose of this investigation was to compare the Ejection Fraction values simultaneously obtained with the Nuclear Stethoscope and with Cineangiography, in 25 patients (17M-8W) subjected to diagnostic cardiac catheterization. In all patients the determination of Ejection Fraction with the Nuclear Stethoscope always preceded the Cineangiography. Ejection Fraction values obtained with Nuclear Stethoscope change from 32 to 75%; those calculated with Cineangiography, between 18 and 88%. The average Ejection Fraction values obtained with Nuclear Stethoscope (59 +/- 13%) doesn't differ significantly from Cineangiography (59 +/- 21%). There was a direct relationship between Ejection Fraction determined by the Nuclear Stethoscope and Cineangiography (r = 0.93; p less than 0.001). In the obtained results the Authors point out that the Ejection Fraction with Nuclear Stethoscope gives assurance in most patients, although in some particular conditions Nuclear Stethoscope provides Ejection Fraction values which differ from those obtained with Cineangiography. They conclude that Nuclear Stethoscope, for its safe, repeating and simple application, is a methodology of useful employment for Ejection Fraction determination in the single patient, which allows a correct definition of the prognosis and a conforming therapeutic strategy.

Adolescent↗

Nomogram for calculation of stenotic cardiac valve areas from cardiac output and mean transvalvular gradient.

In 15 patients (group 1) with isolated mitral stenosis and in 14 patients (group 2) with isolated aortic stenosis the stenotic valve areas were calculated according to: A) Gorlin's formula; B) Hakki's simplified formula, using mean mitral gradient by planimetry or peak-to-peak aortic gradient; C) the three-point simplified formula, using mean gradient calculated by the three-point method for both mitral and aortic valve. The three-point method is definitely easier to use than planimetry. The values (mean +/- SD) of mitral valve areas in group 1 patients were, respectively: 1.56 +/- 0.63 cm2; 1.56 +/- 0.55; 1.51 +/- 0.53. The values of aortic valve areas in group 2 patients were: 0.91 +/- 0.63; 0.77 +/- 0.41; 0.88 +/- 0.52. An excellent correlation was shown between the valve area calculated by Gorlin's formula and both Hakki's simplified formula and the three-point simplified formula. For aortic valve area the correlation is even better if the mean gradient by the three-point method is used instead of the peak-to-peak gradient. On the basis of the simplified formula, a nomogram was constructed which allows an immediate calculation of valve areas from cardiac output and transvalvular gradient.

Adult↗

Diagnostic value of electrocardiogram and vectorcardiogram in postinfarction ventricular asynergy.

The ability of ECG-VCG to predict the severity of postinfarction LV asynergy was evaluated in 152 patients with previous myocardial infarction who underwent left cineventriculography in the right anterior oblique view. Various ECG and VCG signs were examined in order to predict the existence of severe asynergy in general (dyskinesia or akinesia or severe hypokinesia) and of dyskinesia in particular. In patients with inferior myocardial infarction (Group A) persistent ST segment elevation was the only specific ECG sign (100%) of severe asynergy; it had a poor sensitivity (6.2%). Four frontal VCG signs (presence of terminal bite, y- greater than 0.18 mV, maximum early superior vector along x axis = MESV greater than or equal to 1.3 mV, duration of initial superior forces = DISF greater than 50 msec) increased the sensitivity of the ECG-VCG method to 75.8% while maintaining a 100% specificity. Regarding the diagnosis of dyskinesia, only the ECG sign of persistent ST segment elevation and the VCG sign of y- greater than or equal to 0.3 mV had a 100% specificity. The sensitivity of the ECG-VCG method was 33.3% (16.6% ECG and 16.6% VCG). In patients with anterior myocardial infarction (Group B), concerning the diagnosis of severe asynergy, the ECG signs of sigma ST greater than 3 mm in anterior leads; pathologic Q wave in four or more anterior leads (including D1 and aVL); and the presence of LAH or LAH + RBBB, had a 100% specificity and a good sensitivity (60.5%). The VCG sign of a narrow horizontal QRS loop increased the sensitivity of the ECG-VCG method to 71% while maintaining a 100% specificity. As for the diagnosis of dyskinesia, the ECG signs with a 100% specificity were sigma ST greater than or equal to 5 mm in anterior leads, a pathologic Q wave in more than five anterior leads (including I and a VL) and RBBB + LAH; these variables had a sensitivity of 48.3%. The VCG sign of a narrow horizontal QRS loop increased the sensitivity of the ECG-VCG method to 79.3% while maintaining a 100% specificity. In patients with inferior plus anterior myocardial infarction (Group A + B) the signs mentioned above for each group were evaluated, confirming a 100% specificity. Regarding the diagnosis of severe asynergy, the ECG signs had a sensitivity of 61.3%, while VCG increased the sensitivity of the ECG-VCG method to 90.3%.(ABSTRACT TRUNCATED AT 400 WORDS)

Adult↗

Acute hemodynamic effects of acebutolol and propranolol.

The acute hemodynamic effects of intravenous acebutolol, 50 mg, and propranolol, 10 mg, were evaluated in 12 patients undergoing diagnostic cardiac catheterization. Each patient received acebutolol or propranolol according to a list of randomization. Both acebutolol and propranolol depressed left ventricular function. There was a significant increase in left ventricular end-diastolic pressure at rest and after isometric exercise, with a concomitant decrease in cardiac index. Systemic vascular resistance was increased by both drugs. The increment after patients received acebutolol was not statistically significant; however, with propranolol it was statistically significant. The overall hemodynamic effects of acebutolol and propranolol are similar, but a quantitative difference exists in their effect on systemic vascular resistance. Acebutolol, a cardioselective agent, produces less of a peripheral vascular beta 2-blockade than does propranolol.

Acebutolol↗