PubMed Health⌕ Search

Biomedical subjects

E Matson

Publications and source records attributed to E Matson.

At least 19 recordsLinked to original sources

Effect of diode laser and fluoride varnish on initial surface demineralization of primary dentition enamel: an in vitro study.

INTRODUCTION: Previous investigations have demonstrated improved enamel caries resistance after laser irradiation. The purpose of this in vitro study was to assess the caries-preventive potential of 809 nm diode laser treatment of the enamel of primary teeth compared to topical fluoride application. METHODS: Eighty samples of sound primary teeth were embedded in plastic and stored in saline solution. The enamel surface of 80 samples was polished in an area of 2 x 2 mm. These tooth specimens were randomly assigned to one control and three test groups: (1) no treatment/control; (2) application of 0.1 mg of fluoride varnish (Duraphat) for 6 h; (3) diode laser application (809 nm, 140 mJ, 50 Hz, Ø 600 micro m fibre, contact mode, absorber, 1 min; ORA-LASER01 I.S.T.); and (4) combined application - laser/fluoride varnish. Caries-like lesions were created by pH-cycling. After lesion formation, longitudinal sections were taken and examined by polarized light microscopy. RESULTS: In the control group, all samples showed lesions up to 30 micro m in depth. After laser application, lesions could be identified in 15 out of 20 samples. Topical fluoride treatment in groups 2 (varnish) and 4 (laser/varnish) completely inhibited the development of caries-like lesions in all samples. CONCLUSION: In this in vitro investigation, topical fluoride treatment enhances the resistance of sound enamel of primary teeth more effectively than diode laser application.

Chi-Square Distribution↗

The influence of the surface treatment and saliva on the color of two porcelains.

The color of an object is a psychophysical phenomenon. Regarding its physical aspect, the amount of light reflected from the surface of an object is taken into consideration many times. Two brands of porcelain were used to make 10 specimens that were submitted to the following treatments: glaze, grinding, polishing and overglaze. All samples were analyzed with or without saliva. The final color differences of the ceramic were evaluated using a spectrophotometer, and reflectance curves were obtained. Results showed that there were no differences between the brands of porcelain. Saliva did not interfere with the color of the porcelain, but re-established the original one, after the grinding process had altered it. The polishing also contributed to re-established the original color. The overglaze altered the original color, with or without saliva.

Aluminum Silicates↗

Microhardness of Nd:YAG laser irradiated enamel surfaces.

Several studies have been conducted in order to verify effects of laser irradiation on dental structures. However, different settings and methods employed have led to inconclusive results. The aim of this study was to evaluate the effects of several settings of Nd:YAG laser irradiation on enamel microhardness. Fifteen groups of 10 human third molars each were submitted to Vickers microhardness indentations prior to and after laser irradiation. The data were submitted to the t-test for dependent samples (P < 0.05) for statistical evaluation. Lower total delivered energy (under 30 J) resulted in no statistically significant difference of microhardness between irradiated and non-irradiated samples, whereas higher energy settings decreased enamel surface microhardness significantly. This can be due to the significant temperature rise during irradiation. Thus, we conclude that laser irradiation, under the conditions of this study, is not suitable for improving enamel properties, because of decreased microhardness of irradiated samples.

Aluminum Silicates↗

Pulp response and cytotoxicity evaluation of 2 dentin bonding agents.

OBJECTIVE: This study evaluated the biocompatibility of two dentin bonding agents (Clearfil Liner Bond 2 and Scotchbond Multi-Purpose) applied in human dental pulps and cell cultures. METHOD AND MATERIALS: In vivo: Twenty human third molars that were scheduled for extraction were used. After cavity preparation, pulp exposure was achieved with a carbide bur. Hemorrhage control was obtained with saline solution. In 16 teeth, adhesive pulp capping was performed and the cavities were sealed with resin composite. In the control group (n = 4), pulps were capped with Ca(OH)2 and the cavities were sealed with IRM. Teeth were extracted 30 or 90 days following treatment and prepared for histological examination and bacterial detection. In vitro: materials were applied in Petri dishes, where NIH-3T3 cells were plated. The cells were counted 2, 4, and 6 days after plating to obtain the growth curves and to determine cell viability. All data were submitted to statistical analysis. RESULTS: In vivo: Dentin bridge formation was seen in all teeth capped with Ca(OH)2, without an inflammatory response. Mild inflammatory responses and dentin bridge formation after 90 days were observed in 50% of specimens treated with Liner Bond 2. Pulps treated with Scotchbond Multi-Purpose presented mild to severe inflammatory response, and no mineralized tissue formation was detected. Bacteria were not disclosed in any specimen. In vitro: The cytotoxicity was similar between the two bonding agents, and both had statistically higher cytotoxic effects (P < 0.002) than Ca(OH)2. CONCLUSION: Ca(OH)2 produced pulp healing in all teeth and exhibited lower cytotoxic effects than both adhesive systems; however, pulp healing was also observed under Liner Bond 2.

3T3 Cells↗

Nd:YAG laser influence on tensile bond strength of self-etching adhesive systems.

OBJECTIVE: We evaluated the tensile bond strength of composite resin on enamel and dentine, treated with Nd:YAG laser before and after bonding procedures. BACKGROUND DATA: The use of laser radiation in dentistry is being developed day by day. One of the possible applications of dental lasers includes increasing the quality of self-etching bonding systems. METHODS: Forty-eight human teeth were used and separated into six groups: Group 1 (enamel control), Clearfil Liner Bond 2V (CLB 2V); group 2 (enamel), Nd:YAG + CLB 2V; group 3 (enamel), CLB 2V + Nd:YAG; group 4 (dentine control), CLB 2V; group 5 (dentine), Nd:YAG + CLB 2V; group 6 (dentine), CLB 2V + Nd:YAG. Tensile bond strength was performed. RESULTS: Enamel means (15,54) were lower than dentine means (20,38). Bond strength of laser before (15,73) was lower than laser after (20,65). Interaction results G1 x G3; G2 x G3; G4 x G1; G2 x G5 were statistically significant. CONCLUSIONS: Tensile bond strength of composites reached with self-etching adhesive systems were greater in dentine than in enamel. The best moment for application of Nd:YAG laser is after the use of adhesive system. Self-etching adhesive systems tested in this study can be used together with Nd:YAG laser without compromising to adhesion to dentine.

Composite Resins↗

Nd:YAG laser effects on the microleakage of composite resin restorations.

OBJECTIVE: This study evaluated microleakage of composite restorations submitted to marginal treatment with Nd:YAG laser and surface sealant. BACKGROUND DATA: Previous studies have demonstrated that Nd:YAG-lased enamel melted and became recrystallized with a morphologic appearance similar to lava, and has been used clinically in the sealing of enamel pits and fissures. METHODS: Class V cavities in enamel of human premolars were restored with composite resin (Z100, 3M) and randomly divided in six groups: G1, control; G2, surface sealant marginal treatment; G3 to G6, were treated with pulsed Nd:YAG laser (1.064 microm) marginal treatment, contact fiberoptic (300 microm), air cooling, for 30 seconds, powers of 1.2-2 W, repetition rates of 20-30 Hz, energies of 40-100 mJ. Teeth were impermeabilized, immersed in a rhodamine dye, sectioned, and evaluated under stereomicroscope microscopy with scores. RESULTS: There were significant differences between marginal treatments; there were no differences between groups 1, 2, and 4, and 3,5, and 6; lower values of microleakage were at groups 3, 5, and 6 (Kruskal-Wallis,p = 0.05). CONCLUSION: Nd:YAG laser showed improved marginal sealing and decreased microleakage of composite resins restorations.

Acrylic Resins↗

The bactericidal effect of Ho:YAG laser irradiation within contaminated root dentinal samples.

OBJECTIVE: This in vitro study investigates the bactericidal effect of pulsed Ho:YAG laser irradiation in the depth of contaminated dentin specimens. BACKGROUND DATA: Previous studies have shown the effectiveness of laser irradiation in bacterial reduction of infected root canal. METHODS: Root dentin of bovine teeth were sliced longitudinally in 180 samples of 100 microm, 300 microm, and 500 microm thickness, sterilized, dried, and inoculated on one side, with 1 microL of Enterococcus faecalis suspension. The opposite side's were irradiated four times for 5 seconds each with Ho:YAG laser irradiation, a wavelength of 2.10 microm, using four different energy settings: 1 W/5 Hz; 1 W/10 Hz; 1.5 W/5 Hz, and 2.0 W/5 Hz through a 320-microm quartz fiber at an angle of approximately 5 degrees. In addition, two control groups were investigated, the first was inoculated and not submitted to any treatment, the second was inoculated and treated with NaOCl and H2O2. The remaining bacteria from each dentin sample in a transport media were removed by vibration, serially diluted, and plated out on culture dishes selective for Enterococcus faecalis. RESULTS: When compared with the untreated control group or even with the group treated with NaOCl plus H2O2, counting of colonies forming units (CFU) from the laser-treated samples revealed a high significant bacterial elimination with a maximum of 98.46% and a minimum of 83.65%. CONCLUSIONS: Our findings demonstrate a significant decrease of the bacterial population in depth, suggesting that the Ho:YAG laser irradiation could be effective to eliminate the microorganisms harbored within dentin or contaminated canals.

Animals↗

Microleakage of resin-based composite restorations with ceramic inserts.

PURPOSE: To evaluate dye penetration of proximal vertical slot resin-based composite (RBC) restorations as a function of cavity size and restorative material employed (RBC, ceramic inserts with low-viscosity resin, and RBC with low-viscosity resin liner). Microleakage was measured using rank scoring and linear measurement of dye penetration and ANOVA and non-parametric tests were used to evaluate the statistical significance of the results. MATERIALS AND METHODS: Ninety erupted crack- and caries-free mandibular third molars, extracted for orthodontic reasons, were used. Proximal vertical slots were prepared on the mesial surfaces of the teeth using diamond instruments at high speed under distilled water coolant. Teeth were placed randomly into nine groups. Three sizes of diamond burs of an ultrasonic cavity preparation system were used under low energy in order to standardize cavity size and shape, each tip size being used in 30 different teeth. The gingival margins were prepared 1 mm above the cemento-enamel junction. Specimens were etched, prepared with bonding agent, restored using three different materials, and immersed in a 50% AgNO3 solution for 8 hrs and sectioned to evaluate the dye penetration. RESULTS: Statistical analysis revealed no statistically significant differences among the nine groups.

Acid Etching, Dental↗

Nd:YAG laser influence on sound dentin bond strength.

OBJECTIVE: In the present study, the authors evaluated tensile bond strength of composite resin to dentin treated with Nd:YAG laser before and after bonding procedures. SUMMARY BACKGROUND DATA: Lasers have been widely used in dentistry and have contributed to the development of new technologies. Adhesive systems have been indicated for most dental procedures and have produced good results. Studies concerned with the combined use of this adhesive system was the subject of this study. METHODS: Thirty noncarious human anterior teeth, freshly extracted, for periodontal reasons, were used. After grinding the buccal dentinal surface until its exposition, specimens were separated into three groups and received the following treatments: (group 1) control--acid etching plus primer plus bond; (group 2) laser plus acid etching plus primer plus bond; (group 3) acid etching plus primer plus bond plus laser. Specimens of composite resin (Z100, 3M, Saint Paul, MN) were constructed on an inverted truncated 3-mm diameter cone mold. Tensile bond strength was performed using Inströn Universal machine, at 0.5 mm/min speed. RESULTS: Analysis of variance (ANOVA) (p < 0.05) determined that the type of dentinal treatments used had an influence on tensile bond strength. Tukey's test, however, showed that group 1 (15.46) and 3 (15.67) had similar results both of which were higher than group 2 (4.57). CONCLUSIONS: Based on the results obtained, one can conclude that group 1 (without laser) and group 3 (laser after bonding) had similar results, both higher than those observed for group 2 (laser before bonding). These results indicate that more research is needed about how a hybrid layer is formed when laser radiation is used.

Dentin↗

Bond strength to dentin with artificial carious lesions: influence of caries detecting dye.

PURPOSE: To evaluate the influence of dyes for caries detection on tensile bond strength of adhesive materials to artificial carious dentin. MATERIALS AND METHODS: Buccal and lingual enamel of human molars were removed leaving intact dentin surfaces. The entire surface of each specimen was covered with nail varnish, keeping a window area of 4 x 4 mm. Artificial carious lesions were induced with acidified gel. Three dyes (0.5% basic fuchsin; Caries Finder and Cari-D-Tect) were used according to manufacturers' recommendations. Specimens were etched with 35% phosphoric acid for 20 s, washed and dried, leaving a wet dentin surface. The adhesive system (Prime & Bond 2.0) was applied in two layers and light-cured. Restorative materials (TPH Spectrum, Dyract, Advance) were bonded using a 3-mm diameter inverted-cone mold. Control groups were made without dye. Eight samples were tested for each group. After 24 hrs of storage in distilled water, the samples were debonded using a testing machine at 0.5 mm/min crosshead speed. RESULTS: ANOVA and Tukey-Kramer test showed that TPH Spectrum (0.73 MPa) and Dyract (0.74 MPa) had similar bond strengths, and both were higher than Advance (0.0 MPa), which was statistically different (P < 0.01). The use of the dyes did not cause any changes in tensile bond strength for any tested materials.

Analysis of Variance↗

Tensile bond strength of two dentin adhesive systems.

The tensile bond strength of one third-generation (XR Bond) and one fourth-generation (Optibond) adhesive system to dentin was compared. The influence of acid etching of dentin on the bond strength in the XR Bond system was also evaluated. In addition, two kinds of curing (photo and dual) of the Optibond system were evaluated. The Optibond system showed a statistically significant higher tensile bond strength to dentin than the XR Bond system. Etching of the dentin before application to XR Bond did not significantly improve the bond strength to dentin. Both photo and dual curing showed similar bond strengths two hours and seven days after sample preparation.

Acid Etching, Dental↗

Effects of acid etching on dentin surface: SEM morphological study.

The aim of this in vitro study was to evaluate, using scanning electron microscopy (SEM), the effects of acid solutions on dentin surface, and to analyze the depth of demineralization that the acid solutions cause on dentin, using different acids. Fifteen 3-mm thick dentin discs were prepared from the middle third of human molars. Standard smear layer was prepared on the dentin surface using 600 grit sandpaper, for 1 minute. The acids used were 10%, 35% and 37.5% phosphoric acid and 10% maleic acid, for 15 seconds, washed and dried. The control group received no treatment. Dentin discs were fractured, observed on the horizontal surface and also on the fractured surface to evaluate the depth of demineralization. Specimens were immersed in 4% glutaraldehyde in phosphonate buffer, and prepared for SEM examination at 2000X and 4000X magnification. Acid etching of dentin, regardless of the concentration of phosphoric acid, caused removal of the smear layer, exposing the apertures of dentinal tubules. This was not observed when 10% maleic acid was used. At the fractured surface, one could observe an increase in demineralization of the width of dentinal tubules, to a specific depth of about 8.19 to 11 mm, except for 10% maleic acid.

Acid Etching, Dental↗

On the size of Hassall's corpuscles in human fetuses.

The areas of prevailingly solid (SHC) and prevailingly cystic (CHC) Hassall's corpuscles in the thymuses of both male and female fetuses 16-39 weeks old were established. The results show that the mean areas of the Hassall's corpuscles increase with fetal age, with the greatest difference between the 16-19 week and 20-23 week age groups. The data indicate that the thymus represent an organ showing a developmental pattern similar to other organs like the spleen's relative growth in human fetus, whose functions are different during the fetal period, being necessary to study its growth in distinct short periods to determinate differentials growth coefficients.

Age Distribution↗

A morphometrical study of human fetal thymus.

A morphometrical study was made of the thymus lobules in the cortical and medullary layers of male and female fetuses, 16 to 31 weeks old, divided into the age groups 16 to 19, 20 to 23, 24 to 27 and 28 to 31 weeks of intrauterine life. Results were correlated with body and thymus weights; the lobular, cortical and medullary volumes, as obtained using a histometrical method, were proportional to thymus, but not body weight increase. No differences were noted in the volumes and weights investigated as a function of fetal sex.

Body Weight↗

[Microleakage in class V cavities restored with esthetic materials, using different restorative techniques].

The purpose of this study was to compare the microleakage of class V cavities restored with composite resin (CR), resin-modified glass ionomer cement (RMGIC) and polyacid-modified resin composite (PAMRC), using different clinical procedures. Thirty-six noncarious human molars were used in this study. A class V cavity, measuring approximately 3 mm x 4 mm x 2 mm, was prepared in each tooth in both buccal and lingual aspects, with a diamond bur (number 1,093) at high speed, with coolant water spray. The occlusal margin was located on enamel and the gingival margin was located on dentin. The teeth were divided into 9 groups with 8 specimens each. The cavities were restored according to different techniques. The specimens from groups 1, 2, 4 and 5 did not receive acid etching. The samples were stored in water at 37 degrees C for 24 hours, subjected to occlusal load, thermocycled and immersed in rhodamine B. The restorations were then washed and sectioned in buccolingual direction. The depth of dye penetration was scored from zero (no leakage) to 3 (maximum leakage). The Kruskal-Wallis test revealed statistically significant differences between the materials (p < 0.05). PAMRC used without acid etching showed the greatest score of leakage in both margins. In the gingival margin, CR showed scores of leakage lower than those of PAMRC and RMGIC. Additional retentions and acid etching were able to decrease microleakage in PAMRC restorations in both gingival and occlusal margins.

Compomers↗

[Bond strength to dentin of resin composites associated with filled and unfilled adhesive systems].

This study analyzed in vitro two brands of one-step adhesive systems of fourth generation (Optisolo--Kerr, filled; and Single Bond--3M, unfilled) and two composite resins (Prodigy--Kerr and Z100--3M), aiming at evaluating their bond strength to dentin. Eighty human extracted molars were embedded in acrylic resin and grounded until dentin was exposed in longitudinal direction. The specimens were divided in 4 groups. Composite resin cones were bonded to the specimens using the mentioned adhesive systems, following the instructions of the manufacturers. The test-specimens were submitted to tensile tests using a 4442 Universal Mini-Instron Machine with the speed of 0.5 mm/min. The results were converted into MPa, according to the area of adhesion, and submitted to statistical analysis with ANOVA. There was significant statistical difference (p < 0.01) between the adhesive systems (F = 7.24). Optisolo (m = 11.03 +/- 4.23) showed better bond strength than Single Bond (m = 8.37 +/- 4.54). There was no significant statistical difference (p > 0.05) between the composites (F = 0.43).

Bisphenol A-Glycidyl Methacrylate↗