PubMed Health⌕ Search

Biomedical subjects

E P Paganini

Publications and source records attributed to E P Paganini.

At least 19 recordsLinked to original sources

Mortality after acute renal failure: models for prognostic stratification and risk adjustment.

To adjust adequately for comorbidity and severity of illness in quality improvement efforts and prospective clinical trials, predictors of death after acute renal failure (ARF) must be accurately identified. Most epidemiological studies of ARF in the critically ill have been based at single centers, or have examined exposures at single time points using discrete outcomes (e.g., in-hospital mortality). We analyzed data from the Program to Improve Care in Acute Renal Disease (PICARD), a multi-center observational study of ARF. We determined correlates of mortality in 618 patients with ARF in intensive care units using three distinct analytic approaches. The predictive power of models using information obtained on the day of ARF diagnosis was extremely low. At the time of consultation, advanced age, oliguria, hepatic failure, respiratory failure, sepsis, and thrombocytopenia were associated with mortality. Upon initiation of dialysis for ARF, advanced age, hepatic failure, respiratory failure, sepsis, and thrombocytopenia were associated with mortality; higher blood urea nitrogen and lower serum creatinine were also associated with mortality in logistic regression models. Models incorporating time-varying covariates enhanced predictive power by reducing misclassification and incorporating day-to-day changes in extra-renal organ system failure and the provision of dialysis during the course of ARF. Using data from the PICARD multi-center cohort study of ARF in critically ill patients, we developed several predictive models for prognostic stratification and risk-adjustment. By incorporating exposures over time, the discriminatory power of predictive models in ARF can be significantly improved.

APACHE↗

A preliminary survey of bacterial contamination of the dialysate circuit in continuous veno-venous hemodialysis.

AIMS: The problem of dialysate bacterial contamination has not been defined in continuous renal replacement therapy. We assessed the bacterial integrity of source bicarbonate dialysate (study 1) and the continuous veno-venous HD (CVVHD) bicarbonate dialysate circuit (study 2). METHODS: Study 1: 50 ml dialysate were collected from 41 bags randomly selected from 150 consecutively made dialysate bags, immediately after manufacture or after 24, 48 or 72 h. Study 2: 10 ml dialysate were drawn from 4 sample points ranged along the dialysate circuit in 18 therapies (mean duration 119.5 +/- 72.0 h). All points were sampled at therapy start then daily, bar the proximal point which was sampled after each dialysate bag change. All dialysate samples underwent Gram stain and aerobic/anaerobic culture. Samples over 10 ml were cultured after centrifugation (15 min, 4,000 rpm). A disseminated contamination (DC) involved > or = 1 sample point at a time and/or was sustained over time. RESULTS: Study 1: One bag was culture-positive (staphylococcal/diphtheroid growths; 48-h sample). Study 2: Six DCs developed in 6 therapies (1 at therapy end, 5 sustained to therapy end (duration 57.25 +/- 45.95 h), 5 with Gram-negative bacilli, all involving reported growths of > or = 1,000 cfu). Dialyzer-inclusive dialysate circuit changes were more frequent in non-DC therapies (change rate: DC, 0.08 +/- 0.12/day, non-DC, 0.34 +/- 0.23, p = 0.02, permutation tests with general scores) but did not entirely prevent DC or alter it once underway. CONCLUSIONS: Sustained bacterial contamination of bicarbonate-based CVVHD is common and could relate to the completeness of dialysate circuit change. The importance of technique and regular quality control is highlighted.

Bacillus↗

The end-stage renal disease program. Experience with a chronic disease capitated health plan.

The ESRD program has demonstrated the potential for a capitated, disease-oriented, total care method of patient support. Given both the increasing age and complexity of the patient population, not only has the cost per patient decreased over the life of the program, but the standardized mortality rates have also declined. Technology has bridged the gap and made the relative cost per treatment more affordable and science has developed medications and techniques that have enhanced both patient comfort and longevity. As more complex patients enter the fold of the ESRD program, an increased awareness of enhanced coordination of care needs to be recognized.

Humans↗

Role of the nephrologist in the intensive care unit.

Intensive care units (ICUs) are increasingly becoming a focal point for tension between medical specialists. In an extreme approach to this issue, some ICUs have become closed units managed by intensivists, with other specialists, such as nephrologists, having a restricted supportive role. The nephrologist, a subspecialist with broad skills in general internal medicine, has trained and appropriately can serve as the primary physician for patients with significant renal failure and end-stage renal disease in multiple hospital settings, including the ICU. Sick and complex hospitalized patients offer ample opportunity for a collaborative interaction between the nephrologist and intensivist in the ICU.

Continuity of Patient Care↗

A fractional dialysate collection method to estimate solute removal in continuous venovenous hemodialysis.

BACKGROUND: Fractional direct dialysis quantification (fDDQ), whereby a known proportion of dialysate effluent is sampled, can reliably estimate total solute removal in intermittent hemodialysis (IHD). Our study aimed to develop and test the technique in continuous venovenous hemodialysis (CVVHD). METHODS: Twenty dialysate collections (mean duration 23.5 hours, range 17.25 to 26.6) were performed in 12 patients on CVVHD. An infusion pump diverted 10% of the total effluent volume to the fractional collection (fc), the remainder being channeled into the bulk collection (bc). Both fc and bc were collected on ice and assayed for urea nitrogen (UN) and creatinine (Cr). Actual solute removal (ASR) was calculated from the measured effluent volume and solute concentrations of the fc and bc. Estimated solute removal (ESR) was calculated from the product of the fc solute concentration and effluent volume. All fc/bc samples in 15 out of 20 collections underwent gram stain and aerobic/anaerobic culture. RESULTS: Bland-Altman analyses suggested good agreement between ASR and ESR [absolute values of percentage differences: 95% CI = 1.73, 5.17% (UN); 1.88, 4.31% (Cr)]. Favorable concordance correlation coefficients confirmed this [rc = 0.995 (UN), 0.997 (Cr)] and were apparently unaffected by heavy pseudomonal growths in 4 out of 7 culture positive collections [rc = 0.997 (UN), 0.997 (Cr); culture negative (N = 8), rc = 0.996 (UN), 0.997 Cr)]. CONCLUSION: fDDQ, using 24-hour, pump-assisted, cooled fractional dialysate sampling reliably estimates total solute removal and provides a practical alternative to total dialysate collection in assessing delivered dialysis dose.

Creatinine↗

Acute renal failure in the intensive care unit. Therapy overview, patient risk stratification, complications of renal replacement, and special circumstances.

This article provides a basic definition of severity scoring among patients with acute renal failure and extends the definition into the types of dialysis support that are generally used in intensive care unit acute renal failure. Acute dialysis dosing and the problems that create a difference between chronic renal failure and acute renal failure support are described, the dialytic techniques and side effects and complications of each are compared, and nonrenal-based special situations in which extracorporeal therapy has been found to be helpful are defined.

Acute Kidney Injury↗

Peripheral donor leukocytes prolong survival of rat renal allografts.

BACKGROUND: The development of strategies to enhance the survival of transplanted organs and to potentially lower or even discontinue immunosuppressive therapy would represent a significant advancement in post-transplant patient care. METHODS: We studied the effect of pretransplant infusion of donor leukocytes alone or in combination with a short course of cyclosporine on the long-term outcome of a rat model of kidney allograft. RESULTS: A single intravenous infusion of donor peripheral blood leukocytes (100x10(6) cells) from Brown-Norway (BN) rats into major histocompatibility complex (MHC) incompatible Lewis recipients largely failed to prolong kidney allograft viability from the same donor transplanted 60, 40, or 30 days after cell infusion. A short course of cyclosporine (per se, unable to prolong graft survival) was started at the same day of donor leukocyte infusion, but instead was able to prolong the survival of the BN kidney transplant-performed 40 days later-but not of a Wistar Furth (WF) third party, with some animals even developing tolerance. A mixed lymphocyte reaction of host cells from long-term surviving rats to BN stimulator cells was significantly reduced as compared with controls. Donor BN DNA was detected in the peripheral blood of Lewis rats until day 40 after BN leukocyte infusion. Microchimerism persisted (60 to 70 days post-transplant) in most long-term graft recipients. Reducing the time interval between donor leukocyte infusion and subsequent kidney transplant to 10 days still prolonged graft survival. Donor peripheral blood mononuclear cells, but not polymorphonuclear cells, in the leukocyte preparation contributed to prolong kidney allograft survival. CONCLUSIONS: Pretransplant donor leukocyte infusion under the appropriate conditions can tip the immune balance toward improved graft acceptance. This result could be relevant to the achievement of donor-specific tolerance of the graft with the maintenance of an intact response to third-party antigens.

Animals↗

Cooling effect of continuous renal replacement therapy in critically ill patients.

Hypothermia is reported to increase intensive care unit (ICU) mortality. The heat loss that occurs during continuous renal replacement therapy (CRRT) favors the development of hypothermia. In an effort to assess the influence of CRRT on body temperature, we reviewed the records of 72 consecutive ICU patients treated with CRRT and further prospectively studied the temperature in the inlet and outlet lines for blood and dialysate of 27 other patients at various flow settings during continuous venovenous hemodialysis (CVVHD). Among the 72 retrospective cases, 36 episodes of hypothermia (core body temperature <35.5 degrees C) occurred and persisted for a mean of 2.6+/-1.8 days. It was more frequent during venovenous than arteriovenous modalities (31 of 67 v5 of 20, respectively); no patients developed hypothermia during arteriovenous slow continuous ultrafiltration (AVSCUS), whereas 48% of the patients undergoing CVVHD became hypothermic, occurring earlier in the therapy course (days 2 to 4). Mean arterial pressure (MAP) tended to increase after CRRT initiation, but absolute changes were not statistically significant. In the prospective arm, the CVVHD circuit temperatures were directly measured. Whereas no attempt was made to change body temperature, stepwise changes in blood (Qb) and dialysate flow rate (Qd) produced venous circuit temperature changes: the higher the Qb, the smaller the arteriovenous temperature differences independent of changes in Qd (P < 0.001). Also, venous circuit temperature varied directly with Qd at fixed Qb (P < 0.001). This relationship also held for temperature conversion to lost energy units per minute. Using room temperature dialysate, CRRT may significantly lower patients' core temperatures. Although the clinical significance of this effect is not clear at this point, energy loss during CVVHD may be important in hemodynamic stability or patient prognosis.

APACHE↗

The move from dead to living membranes: bioartificial organ support of failing systems.

Several studies show that the diagnosis of acute renal failure still is predictive of high mortality. The reasons for this dismal prognosis despite improvements in dialytic methodologies and critical care are not entirely clear. Continuous renal replacement therapies have to date not shown improved outcome. Dialysis is conceptually not truly a "renal replacement therapy," because the many reabsorptive, metabolic, synthetic, and endocrine functions that occur in the kidney are not duplicated. This dilemma is applicable in varying degrees to other failing organs. Another therapeutic approach to a variety of organ failure conditions could be the transplantation of specific cell types to replace specific functions in the diseased host. The phenomenon of bioencapsulation with synthetic semipermeable membranes offers the possibility of allowing transplanted cells to function while sequestering them from the host's immune system. At this time, a bioartificial kidney is being developed that can be placed in series with a hemofilter and consists of proximal tubular cells layered on the surface of the hollow fibers of a dialyzer. Metabolic and transport functions appear to be intact. Further testing and refinement of this model will occur, which represents a potentially revolutionary form of therapy for renal disease.

Acute Kidney Injury↗

Predictors of mortality and the provision of dialysis in patients with acute tubular necrosis. The Auriculin Anaritide Acute Renal Failure Study Group.

To explore the natural history of critically ill patients with acute renal failure due to acute tubular necrosis, we evaluated 256 patients enrolled in the placebo arm of a randomized clinical trial. Death and the composite outcome, death or the provision of dialysis, were determined with follow-up to 60 d. The relative risks (RR) and 95% confidence intervals (95% CI) associated with routinely available demographic, clinical, and laboratory variables were estimated using proportional hazards regression. Ninety-three (36%) deaths were documented; an additional 52 (20%) patients who survived received dialysis. Predictors of mortality included male gender (RR, 2.01; 95% CI, 1.21 to 3.36), oliguria (RR, 2.25; 95% CI, 1.43 to 3.55), mechanical ventilation (RR, 1.86; 95% CI, 1.18 to 2.93), acute myocardial infarction (RR, 3.14; 95% CI, 1.85 to 5.31), acute stroke or seizure (RR, 3.08; 95% CI, 1.56 to 6.06), chronic immunosuppression (RR, 2.37; 95% CI, 1.16 to 4.88), hyperbilirubinemia (RR, 1.06; 95% CI, 1.03 to 1.08 per 1 mg/dl increase in total bilirubin) and metabolic acidosis (RR, 0.95; 95% CI, 0.90 to 0.99 per 1 mEq/L increase in serum bicarbonate concentration). Predictors of death or the provision of dialysis were oliguria (RR, 5.95; 95% CI, 3.96 to 8.95), mechanical ventilation (RR, 1.53; 95% CI, 1.07 to 2.21), acute myocardial infarction (RR, 1.95; 95% CI, 1.24 to 3.07), arrhythmia (RR, 1.51; 95% CI, 1.04 to 2.19), and hypoalbuminemia (RR, 0.56; 95% CI, 0.42 to 0.74 per 1 g/dl increase in serum albumin concentration). Neither mortality nor the provision of dialysis was related to patient age. These observations can be used to estimate risk early in the course of acute tubular necrosis. Furthermore, these and related models may be used to adjust for case-mix variation in quality improvement efforts, and to objectively stratify patients in future intervention trials aimed at favorably altering the course of hospital-acquired acute renal failure.

Adult↗

A protocol for coadministration of i.v. iron dextran and heparin in chronic hemodialysis patients.

The coadministration of intravenous iron dextran and heparin as a continuous infusion during hemodialysis (HD) is a safe and effective method used in maintaining and/or increasing iron stores and hematocrit levels in patients with end stage renal disease (ESRD). The technique of mixing iron dextran in low doses with heparin and infusing this mixture via the heparin syringe pump on the dialysis machine has shown to be cost effective, as well as instrumental in reducing the risk of adverse reactions due to rapid infusion or large dose infusion of iron dextran. At the Cleveland Clinic Foundation, we developed a protocol based on this methodology. A total of more than 1,000 doses of intravenous iron dextran and heparin have been administered to our HD patients using this technique, and no adverse reactions have been reported or observed.

Algorithms↗

Central venous dialysis catheter dysfunction.

Central venous catheter dysfunction is a limiting factor in regard to renal replacement therapy efficiency and can thus influence patient morbidity. Early catheter dysfunction is frequently due to mechanical problems such as inadequate positioning, kinking, or constriction, but early fibrin deposition can develop soon after insertion. Delayed dysfunction usually results from thrombus formation, either within the lumen, around the catheter ("fibrin sleeve"), or in the host vein. Catheter dysfunction is suspected clinically or documented by simple imaging studies. It is usually evident and manifested by failure to aspirate blood from the lumen(s), inadequate blood flow and/or high resistance pressures during hemodialysis. However, a more subtle dysfunction may lead to a high recirculation of dialyzed blood and be overlooked if dialysis adequacy is not monitored regularly. Local instillation of a fibrinolytic agent is usually successful in restoring catheter patency. Central venous dialysis catheters present intrinsic limitations consequent to their composition and design, whereas extrinsic limitations result from site of insertion, blood properties and anatomic particularities of a given individual. These characteristics largely determine overall catheter performances. Performance parameters to consider include maximal consistently achievable blood flow rate, resistance to blood flow indicated by arterial and venous pressures during hemodialysis, and blood recirculation rate. Catheter longevity is an important consideration for cuffed catheters implanted for long-term use. The tolerated blood recirculation within central venous dialysis catheters should be below 10% to 15%, and is ideally between 3% to 7% in most clinical settings. Several recent studies confirm that short femoral catheters recirculate significantly more than is desirable. Well functioning and nonreversed internal jugular and subclavian venous catheters have, in general, recirculation rates less than 5%. With regard to various performance criteria, the TwinCath (Medcomp, Harleysville, PA) appears particularly advantageous. In any case, a good catheter maintenance program is of critical importance for the prevention and the early detection of catheter dysfunction.

Catheterization, Central Venous↗

Validity of four models for predicting outcome in critically ill acute renal failure patients.

OBJECTIVE: Several mathematical models are used to predict the survival of patients in renal failure and have become standards. Few of these models have been sufficiently validated, however, and their applicability at other institutions has been established. DESIGN: We attempted to validate four models used to predict mortality in the setting of acute renal failure (Lohr, Bullock, Cioffi, APACHE II) with a registry of 512 ICU patients who received acute dialysis at our institution between 1988 and 1992. Using mortality as an endpoint, we applied each model as described by the original authors and compared the predicted results against the actual outcomes recorded in the registry. RESULTS: The Lohr Model is based on five risk factors thought to predict mortality or survival. Although we found these five factors were strongly associated with mortality (p < 0.001), more than 20% of the highest-risk group survived. The Bullock Model predicted only 20% of the mortality of our data. For the Cioffi Model, the original study found a clear discrimination score (survivors: 1.76, non-survivors: -0.423); however, we found no significant difference in the score discriminating survivors and non-survivors (survivors: 0.70, non-survivors: 0.71, p = 0.96). APACHE II is a risk model consisting of a premorbid assessment of chronic health and 12 physiologic variables taken during ICU admission. We applied APACHE II to both our cardiac and non-cardiac patients, and found that this score did not discriminate between survivors and non-survivors (p values ranged from 0.37 to 0.62) in acute renal failure in either case: the original APACHE II system was not applied to cardiac surgery patients. CONCLUSIONS: We conclude that models with good performance in their institutions of origin may not be valid in other institutions. Before using a predictive model, validity testing at the specific institution should be undertaken.

APACHE↗