Central venous dialysis catheter dysfunction.

Abstract

Central venous catheter dysfunction is a limiting factor in regard to renal replacement therapy efficiency and can thus influence patient morbidity. Early catheter dysfunction is frequently due to mechanical problems such as inadequate positioning, kinking, or constriction, but early fibrin deposition can develop soon after insertion. Delayed dysfunction usually results from thrombus formation, either within the lumen, around the catheter ("fibrin sleeve"), or in the host vein. Catheter dysfunction is suspected clinically or documented by simple imaging studies. It is usually evident and manifested by failure to aspirate blood from the lumen(s), inadequate blood flow and/or high resistance pressures during hemodialysis. However, a more subtle dysfunction may lead to a high recirculation of dialyzed blood and be overlooked if dialysis adequacy is not monitored regularly. Local instillation of a fibrinolytic agent is usually successful in restoring catheter patency. Central venous dialysis catheters present intrinsic limitations consequent to their composition and design, whereas extrinsic limitations result from site of insertion, blood properties and anatomic particularities of a given individual. These characteristics largely determine overall catheter performances. Performance parameters to consider include maximal consistently achievable blood flow rate, resistance to blood flow indicated by arterial and venous pressures during hemodialysis, and blood recirculation rate. Catheter longevity is an important consideration for cuffed catheters implanted for long-term use. The tolerated blood recirculation within central venous dialysis catheters should be below 10% to 15%, and is ideally between 3% to 7% in most clinical settings. Several recent studies confirm that short femoral catheters recirculate significantly more than is desirable. Well functioning and nonreversed internal jugular and subclavian venous catheters have, in general, recirculation rates less than 5%. With regard to various performance criteria, the TwinCath (Medcomp, Harleysville, PA) appears particularly advantageous. In any case, a good catheter maintenance program is of critical importance for the prevention and the early detection of catheter dysfunction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Leblanc, J Y Bosc, E P Paganini, B Canaud. 1997. Central venous dialysis catheter dysfunction.. https://doi.org/10.1016/s1073-4449(97)70026-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A novel technique in selective venous sampling in the localization of parathyroid tumours utilizing a micro-wire and standardized catheter.

Selective venous sampling (SVS) is a useful technique to localize a number of hormone-producing tumours, such as parathyroid tumours, when other imaging techniques are inconclusive. Typically, a 5 French selective single end-hole catheter and standard hydrophilic wire are utilized to access the required vessels and an attempt made to withdraw blood. However, most interventional radiologists are familiar with the difficulty and limited success in withdrawing venous blood through an end-hole catheter. We describe a simple, cheap and novel technique utilizing a micro-wire that we have developed in our interventional suite to overcome this common problem. Having reached the target site with the selective end-hole catheter, a Tuohy Borst adapter is attached to the catheter end. A 0.018-inch micro-wire is then inserted through the selective end-hole catheter such that the distal wire tip exits the distal catheter tip. The purpose of the micro-wire exiting the catheter is to both straighten the catheter tip to a position parallel to the vessel, allowing easier aspiration as well as physically preventing blockage of the catheter by the vein intimal wall collapse on suction. The 5-ml sample required for PTH assay is then successfully obtained via the Tuohy Borst adapter.

Catheterization, Central Venous↗

[Subclavian thrombosis after port system implantation].

The use of implanted central venous catheters with ports has become almost irreplaceable in clinical treatment of cancer patients with advanced disease. It improves the patient's quality of life and simplifies medical treatment. For safe use during outpatient follow-up treatment, possible complications such as wound infections, thrombosis or even pulmonary embolism have to be considered. The incidence of catheter-associated thrombosis in cancer patients has been estimated as 25-66% in screening evaluations. Clinical symptoms were present in only in 6-28% of all patients with diagnosed thromboses. We report on a patient with metastatic malignant melanoma, who developed a deep arm vein thrombosis two weeks after port implantation. The prognosis of deep arm vein thrombosis is determined by the development of pulmonary embolism (8-36%). In such cases, early diagnosis and treatment are essential for the patient's survival.

Catheterization, Central Venous↗