One year clinical follow up of paclitaxel eluting stents for acute myocardial infarction compared with sirolimus eluting stents.

OBJECTIVE: To compare clinical outcome of paclitaxel eluting stents (PES) versus sirolimus eluting stents (SES) for the treatment of acute ST elevation myocardial infarction. DESIGN AND PATIENTS: The first 136 consecutive patients treated exclusively with PES in the setting of primary percutaneous coronary intervention for acute myocardial infarction in this single centre registry were prospectively clinically assessed at 30 days and one year. They were compared with 186 consecutive patients treated exclusively with SES in the preceding period. SETTING: Academic tertiary referral centre. RESULTS: At 30 days, the rate of all cause mortality and reinfarction was similar between groups (6.5% v 6.6% for SES and PES, respectively, p = 1.0). A significant difference in target vessel revascularisation (TVR) was seen in favour of SES (1.1% v 5.1% for PES, p = 0.04). This was driven by stent thrombosis (n = 4), especially in the bifurcation stenting (n = 2). At one year, no significant differences were seen between groups, with no late thrombosis and 1.5% in-stent restenosis (needing TVR) in PES versus no reinterventions in SES (p = 0.2). One year survival free of major adverse cardiac events (MACE) was 90.2% for SES and 85% for PES (p = 0.16). CONCLUSIONS: No significant differences were seen in MACE-free survival at one year between SES and PES for the treatment of acute myocardial infarction with very low rates of reintervention for restenosis. Bifurcation stenting in acute myocardial infarction should, if possible, be avoided because of the increased risk of stent thrombosis.

Adult↗

Methodological considerations and approach to cross-technique comparisons using in vivo coronary plaque characterization based on intravascular ultrasound radiofrequency data analysis: insights from the Integrated Biomarker and Imaging Study (IBIS).

Grey scale intravascular ultrasound (IVUS) is a valuable clinical tool to assess the extent and severity of coronary atheroma. However, it cannot reliably identify plaques with a high-risk of future clinical events. Serial IVUS studies to assess the progression and/or regression of atherosclerotic plaques demonstrated only modest effects, of pharmacological intervention on plaque burden, even when clinical efficacy is documented. Spectral analysis of radiofrequency ultrasound data (IVUS-virtual histology (IVUS-VH), Volcano Therapeutics, Rancho Cordova, CA) has the potential to characterize accurately plaque composition. The Integrated Biomarker and Imaging Study (IBIS) evaluated both invasive and non-invasive imaging techniques along with the assessment of novel biomarkers to characterize sub-clinical atherosclerosis. IVUS-VH was not included at the start of the IBIS protocol. The purpose of this paper is to describe the methodology we used to obtain and analyse IVUS-VH images and the approach to cross-correlations with the other techniques.

Biomarkers↗

Sonotherapy, antirestenotic therapeutic ultrasound in coronary arteries: the first clinical experience.

We studied the safety and feasibility of intracoronary sonotherapy (IST) and its effect on the coronary vessel at 6 months. Thirty-seven patients with stable or unstable angina were included (40 lesions). The indication was de novo lesion (n = 26), restenosis (n = 2), in-stent restenosis (n = 11), and a total occlusion of a venous bypass graft. After successful angioplasty, IST was performed using a 5 Fr catheter with three serial ultrasound transducers operating at 1 MHz. IST was successfully performed in 36 lesions (success rate, 90%). IST exposure time per lesion was 718 +/- 127 sec. During hospital stay, one patient died due to a bleeding complication. At 6-month follow-up, one patient experienced acute myocardial infarction, eight patients underwent repeat PTCA. No patient underwent CABG. Late lumen loss was 1.05 +/- 0.70 mm with a restenosis rate of 25%. IVUS analysis revealed a neointima burden of 25% +/- 11%. IST can be applied safely and with high acute procedural success. Sonotherapy-related major adverse events were not observed. Late lumen loss and neointimal growth were similar to conventional PTCA approaches. These results justify the initiation of randomized clinical efficacy studies.

Aged↗

Clinical and angiographic acute and follow up results of intracoronary beta brachytherapy in saphenous vein bypass grafts: a subgroup analysis of the multicentre European registry of intraluminal coronary beta brachytherapy (RENO).

OBJECTIVE: To assess clinically and angiographically the feasibility, safety, and effectiveness of vascular brachytherapy (VBT) in saphenous vein bypass grafts (SVG). PATIENTS AND METHODS: 67 of 1098 (6.1%) consecutive patients of the European registry of intraluminal coronary beta brachytherapy underwent treatment for 68 SVG lesions by VBT using a Sr/Y(90) source train (BetaCath). Clinical follow up data were obtained for all of them after a mean (SD) of 6.3 (2.4) months and angiographic follow up was performed in 61 patients (91.0%) after 6.9 (2.0) months. RESULTS: 58 (86.6%) patients were men, their mean (SD) age was 66 (10) years, 28 (41.8%) had unstable angina, and 21 (31.3%) had diabetes. Fifty three (77.9%) lesions were in-stent restenosis, 13 (19.1%) de novo lesions, and 2 (3.0%) non-stented restenotic lesions. Mean (SD) reference diameter before the intervention was 4.19 (0.52) mm, mean (SD) lesion length was 23.56 (20.38) mm, and mean (SD) minimum lumen diameter measured 0.73 (0.62) mm. Mean (SD) acute gain was 3.02 (0.88) mm. The prescribed radiation dose was 20.1 (3.2) Gy. Pullback manoeuvres were performed in 17 (25.0%) of cases. Most patients received combined aspirin and thienopyridin treatment for 6 or 12 months after the procedure. Technical success was obtained in 62 (91.2%) treated lesions and in-hospital major adverse cardiac events occurred in 4.5%. At follow up, mean (SD) reference diameter was 4.20 (0.53) mm, minimum lumen diameter 2.94 (1.50) mm, and late loss 0.86 (1.25) mm. The overall major adverse cardiac events rate was 26.7%. CONCLUSION: VBT of SVG is feasible and safe. At follow up the reintervention rate and cardiac morbidity and mortality seem to be favourable, considering that interventions in SVG usually are associated with the highest risks.

Aged↗

Angiographic findings of the multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL): sirolimus-eluting stents inhibit restenosis irrespective of the vessel size.

BACKGROUND: Restenosis remains the major limitation of coronary catheter-based intervention. In small vessels, the amount of neointimal tissue is disproportionately greater than the vessel caliber, resulting in higher restenosis rates. In the Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL) trial, approximately 40% of the vessels were small (<2.5 mm). The present study evaluates the relationship between angiographic outcome and vessel diameter for sirolimus-eluting stents. METHODS AND RESULTS: Patients were randomized to receive either an 18-mm bare metal Bx VELOCITY (BS group, n=118), or a sirolimus-eluting Bx VELOCITY stent (SES group, n=120). Subgroups were stratified into tertiles according to their reference diameter (RD; stratum I, RD <2.36 mm; stratum II, RD 2.36 mm to 2.84 mm; stratum III, RD >2.84 mm). At 6-month follow-up, the restenosis rate in the SES group was 0% in all strata (versus 35%, 26%, and 20%, respectively, in the BS group). In-stent late loss was 0.01+/-0.25 versus 0.80+/-0.43 mm in stratum I, 0.01+/-0.38 versus 0.88+/-0.57 mm in stratum II, and -0.06+/-0.35 versus 0.74+/-0.57 mm in stratum III (SES versus BS). In SES, the minimal lumen diameter (MLD) remained unchanged (Delta -0.72 to 0.72 mm) in 97% of the lesions and increased (=late gain, DeltaMLD <-0.72 mm) in 3% of the lesions. Multivariate predictors for late loss were treatment allocation (P<0.001) and postprocedural MLD (P= 0.008). CONCLUSIONS: Sirolimus-eluting stents prevent neointimal proliferation and late lumen loss irrespective of the vessel diameter. The classic inverse relationship between vessel diameter and restenosis rate was seen in the bare stent group but not in the sirolimus-eluting stent group.

Angioplasty, Balloon, Coronary↗

Flow velocity and predictors of a suboptimal coronary flow velocity reserve after coronary balloon angioplasty.

AIMS: This study was conducted to analyse flow velocity parameters and predictors of a suboptimal coronary flow reserve (<2.5) following balloon angioplasty. METHODS: Two hundred and twenty-five patients underwent sequential intracoronary Doppler as part of the DEBATE I study. Of these, 183, with complete angiography and Doppler at the 6-month follow-up, were included. Univariate and multivariate logistic analysis was performed to identify independent predictors of post-procedural suboptimal coronary flow reserve, defined as coronary flow reserve <2.5. RESULTS: Forty-eight per cent (n=88) of the patients achieved a suboptimal coronary flow reserve. These patients had higher baseline velocities (cm.s(-1)) before balloon angioplasty (18+/-9 vs 14+/-6, P=0.004), after balloon angioplasty (22+/-11 vs 14+/-5, P<0.001) and at follow-up (19+/-9 vs 16+/-6, P=0.011) than the optimal coronary flow reserve group. Although the suboptimal group had lower hyperaemic velocities (cm.s(-1)) after balloon angioplasty than the optimal group (42+/-17 vs 49+/-16, P=0.008), these velocities became similar at follow-up. Increasing age (odds ratio, OR 1.071, P=0.0002), female gender (OR 2.52, P=0.014) and increasing pre-procedural baseline average peak velocities (OR 1.056, P<0.001) were found to be independent predictors of a suboptimal coronary flow reserve following balloon angioplasty. CONCLUSION: A suboptimal coronary flow reserve was associated with (1) a chronically elevated baseline average peak velocity (2) a transient deficit in the hyperaemic average peak velocity (3) the elderly, and female gender.

Angioplasty, Balloon↗

Routine intracoronary beta-irradiation. Acute and one year outcome in patients at high risk for recurrence of stenosis.

AIMS: Intracoronary radiation is a promising therapy potentially reducing restenosis following catheter-based interventions. Currently, only limited data on this treatment are available. The feasibility and outcome in daily routine practice, however, is unknown. METHODS AND RESULTS: In 100 consecutive patients, intracoronary beta-radiation was performed with a (90)Strontium system (Novoste Beta-Cathtrade mark) following angioplasty. Predominantly complex (73% type B2 and C) and long lesions (length 24.3+/-15.3 mm) were included (37% de novo, 19% restenotic and 44% in-stent restenotic lesions). Radiation success was 100%. Mean prescribed dose was 19.8+/-2.5 Gy. A pullback procedure was performed in 19% lesions. Geographic miss occurred in 8% lesions. Periprocedural thrombus formation occurred in four lesions, dissection in nine lesions. During hospital stay, no death, acute myocardial infarction, or repeat revascularization was observed. Major adverse cardiac events occurred predominantly between 6 and 12 months after the index procedure with major adverse cardiac event-free survival of 66% at 12 months (one death, 10 Q-wave myocardial infarctions, 23 target vessel revascularizations; ranked for worst event). CONCLUSION: Routine catheter-based intracoronary beta-radiation therapy after angioplasty is safe and feasible with a high acute procedural success. The clinical 1-year follow-up showed delayed occurrence of major adverse cardiac events between 6 and 12 months after the index procedure.

Aged↗

Value of coronary stenotic flow velocity acceleration in prediction of angiographic restenosis following balloon angioplasty.

INTRODUCTION: Quantitative angiographic assessment after balloon angioplasty is a poor predictor of immediate and long-term outcome. However, the measurement of blood flow velocity during angioplasty has been proved clinically useful. AIMS: To analyse the value of the maximal stenotic flow velocity and the presence of stenotic flow velocity acceleration (aSV) for the long-term outcome after balloon angioplasty. METHODS AND RESULTS: Patients undergoing single lesion angioplasty within the DEBATE trial were included. aSV was defined as acceleration in the stenotic coronary flow velocity >50% baseline velocity assessed at a reference site of the target vessel. After balloon angioplasty diameter stenosis, minimal lumen diameter (MLD) and coronary flow velocity reserve were similar between the aSV (n=54) and non-aSV group (n=125). At follow-up, the aSV group had a higher restenosis rate (52% vs 30%, P=0.006) The presence of aSV was the strongest independent predictor of restenosis (OR 3.08, 95% CI 1.35 to 7.05, P=0.008). The best predictive cut-off value of SV was 101cm.s(-1) (sensitivity of 46%, specificity of 81%, positive predictive value of 85% and a negative predictive value of 58%). CONCLUSION: Following angioplasty, SV appears to be exquisitely sensitive to the changes experienced at the treated area without depending on the status of the microcirculation.

Angioplasty, Balloon↗

Sirolimus eluting stent in the treatment of atherosclerosis coronary artery disease.

Stent implantation represents the most commonly performed percutaneous coronary intervention nowadays. However, instent restenosis due to exaggerated neointimal hyperplasia remains a problem to overcome. Neointimal hyperplasia is a vascular response to stent injury; it mainly consists of smooth muscle cells proliferation. The underlying molecular mechanisms of restenosis were explained in this review article. Recently, drug-eluting stent has been proposed as a potential method to prevent instent restenosis. Animal studies have confirmed safety and efficacy of sirolimus-eluting stent implantation in vivo. The FIM trial, which was the first clinical study on sirolimus-eluting stent in de novo lesions, has shown an astonishing 0% restenosis rate. The RAVEL trial was the first prospective, double-blind, multi-center trial that randomized 238 patients at 19 institutions with de novo lesions into sirolimus-eluting versus bare Bx velocity stent. Six-month binary restenosis rate in the sirolimus-group was again 0% compared to 26.6% in the control group. Angiographic late loss and major cardiac event were also significantly lower in the sirolimus-group. The SIRIUS trial is an ongoing study conducted in 53 US centers that randomized 1100 patients with de novo lesion into sirolimus-eluting and bare stents. Preliminary results also showed a significant reduction in binary restenosis, late loss and repeat revascularization rates. Apart from de novo lesions, early experience of sirolimus-eluting stent implantation for instent restenosis in non-randomized study was also promising, achieving a single-digit repeat restenosis rate. As compare with standard coronary stent, a sirolimus-eluting stent shows considerable promise for the prevention of neointimal proliferation, restenosis and associated clinical events.

Angioplasty, Balloon, Coronary↗

"Edge Effect" of (32)p radioactive stents is caused by the combination of chronic stent injury and radioactive dose falloff.

BACKGROUND: Radioactive stents have been reported to reduce in-stent neointimal thickening. An unexpected increase in neointimal response was observed, however, at the stent-to-artery transitions, the so-called "edge effect." To investigate the factors involved in this edge effect, we studied stents with 1 radioactive half and 1 regular nonradioactive half, thereby creating a midstent radioactive dose-falloff zone next to a nonradioactive stent-artery transition at one side and a radioactive stent-artery transition at the other side. METHODS AND RESULTS: Half-radioactive stents (n=20) and nonradioactive control stents (n=10) were implanted in the coronary arteries of Yucatan micropigs. Animals received aspirin and clopidogrel as antithrombotics. After 4 weeks, a significant midstent stenosis was observed by angiography in the half-radioactive stents. Two animals died suddenly because of coronary occlusion at this mid zone at 8 and 10 weeks. At 12-week follow-up angiography, intravascular ultrasound and histomorphometry showed a significant neointimal thickening at the midstent dose-falloff zone of the half-radioactive stents, but not at the stent-to-artery transitions at both extremities. Such a midstent response (mean angiographic late loss 1.0 mm) was not observed in the nonradioactive stents (mean loss 0.4 to 0.6 mm; P< 0.01). CONCLUSIONS: The edge effect of high-dose radioactive stents in porcine coronary arteries is associated with the combination of stent injury and radioactive dose falloff.

Animals↗

Randomized comparison of coronary stent implantation under ultrasound or angiographic guidance to reduce stent restenosis (OPTICUS Study).

BACKGROUND: Observational studies in selected patients have shown remarkably low restenosis rates after ultrasound-guided stent implantation. However, it is unknown whether this implantation strategy improves long-term angiographic and clinical outcome in routine clinical practice. Methods and Results-- A total of 550 patients with a symptomatic coronary lesion or silent ischemia were randomly assigned to either ultrasound-guided or angiography-guided implantation of </=2 tubular stents. The primary end points were angiographic dichotomous restenosis rate, minimal lumen diameter, and percent diameter stenosis after 6 months as determined by quantitative coronary angiography. Secondary end points were the occurrence rates of major adverse cardiac events (death, myocardial infarction, coronary bypass surgery, and repeat percutaneous intervention) after 6 and 12 months of follow-up. At 6 months, repeat angiography revealed no significant differences between the groups with ultrasound- or angiography-guided stent implantation with respect to dichotomous restenosis rate (24.5% versus 22.8%, P=0.68), minimal lumen diameter (1.95+/-0.72 mm versus 1.91+/-0.68 mm, P=0.52), and percent diameter stenosis (34.8+/-20.6% versus 36.8+/-19.6%, P=0.29), respectively. At 12 months, neither major adverse cardiac events (relative risk, 1.07; 95% CI 0.75 to 1.52; P=0.71) nor repeat percutaneous interventions (relative risk 1.04; 95% CI 0.64 to 1.67; P=0.87) were reduced in the ultrasound-guided group. CONCLUSIONS: This study does not support the routine use of ultrasound guidance for coronary stenting. Angiography-guided optimization of tubular stents can be performed with comparable angiographic and clinical long-term results.

Blood Vessel Prosthesis Implantation↗

Geographical miss during catheter-based intracoronary beta-radiation: incidence and implications in the BRIE study. Beta-Radiation In Europe.

OBJECTIVES: We sought to determine the incidence and causes of geographical miss (GM) and to evaluate its impact on edge restenosis after intracoronary beta-radiation therapy. BACKGROUND: Edge restenosis is a limitation of intracoronary beta-radiation therapy. Geographical miss is the situation in which the radiation source does not fully cover the injured segment and may lead to edge restenosis. METHODS: We analyzed 175 vessels treated according to the Beta-Radiation In Europe (BRIE) study protocol. The effective irradiated segment (EIRS) and both edges were studied with quantitative coronary angiography. The edges of the EIRS that were injured constituted the GM edges. Restenosis was defined as diameter stenosis >50% at follow-up. Geographical miss was determined by simultaneous electrocardiographic-matched, side-by-side projection of the source and balloons deflated at the injury site, in identical angiographic projections surrounded by contrast. RESULTS: Geographical miss affected 41.2% of the edges and increased edge restenosis significantly compared with non-GM edges (16.3% vs. 4.3%, respectively, p = 0.004). Restenosis was increased both in the proximal (p = 0.05) and distal (p = 0.02) GM edges compared with noninjured edges. Geographical miss associated with stent injury significantly increased edge restenosis (p = 0.006), whereas GM related to balloon injury did not significantly increase edge restenosis (p = 0.35). The restenosis in the EIRS was similar between vessels with and without GM (24.3% and 21.6%, respectively, p = 0.8). CONCLUSIONS: Geographical miss is strongly associated with restenosis at the edges of the EIRS. This effect is more prominent when caused by stenting. Geographical miss does not increase restenosis in the EIRS.

Adult↗

The pattern of restenosis and vascular remodelling after cold-end radioactive stent implantation.

BACKGROUND: Edge restenosis is a major problem after radioactive stenting. The cold-end stent has a radioactive mid-segment (15.9 mm) and non-radioactive proximal and distal 5.7 mm segments. Conceptually this may negate the impact of negative vascular remodelling at the edge of the radiation. METHOD AND RESULTS: ECG-gated intravascular ultrasound with three-dimensional reconstruction was performed post-stent implantation and at the 6-month follow-up to assess restenosis within the margins of the stent and at the stent edges in 16 patients. Angiographic restenosis was witnessed in four patients, all in the proximal in-stent position. By intravascular ultrasound in-stent neointimal hyperplasia, with a >50% stented cross-sectional area, was seen in eight patients. This was witnessed proximally (n=2), distally (n=2) and in both segments (n=4). Echolucent tissue, dubbed the 'black hole' was seen as a significant component of neointimal hyperplasia in six out of the eight cases of restenosis. Neointimal hyperplasia was inhibited in the area of radiation: Delta neointimal hyperplasia=3.72 mm3 (8.6%); in-stent at the edges of radiation proximally and distally Delta neointimal hyperplasia was 7.9 mm3 (19.0%) and 11.4 mm3 (25.6%), respectively (P=0.017). At the stent edges there was no significant change in lumen volume. CONCLUSIONS: Cold-end stenting results in increased neointimal hyperplasia in in-stent non-radioactive segments.

Brachytherapy↗

Value of coronary stenotic flow velocity acceleration on the prediction of long-term improvement in functional status after angioplasty.

BACKGROUND: The coronary flow velocity acceleration at the stenotic site (SVA), defined as a > or = 50% increase in resting stenotic velocity when compared with the reference segment, has been shown to be highly sensitive and specific for the diagnosis of a hemodynamically significant stenosis. In this study, we describe the value of postprocedural SVA for the prediction of a lack of improvement in functional activity at long-term follow-up balloon angioplasty (BA). METHODS: We investigated the improvement in functional activity in patients undergoing single native vessel angioplasty and intracoronary Doppler (before BA, after BA, and again at 6-month follow-up) as part of the Doppler Endpoints Balloon Angioplasty Trial Europe (DEBATE) I trial. Lack of improvement was defined as no change in Duke Activity Status Index (DASI) at 6-month follow-up, whereas SVA was defined as > or = 50% elevation in resting velocity at the treated area compared with the distal measurement. RESULTS: SVA was found more frequently in patients without improvement in DASI (45% vs 31%, P =.03). Similar percent diameter stenosis and coronary flow velocity reserve were observed in patients with and those without improvement in DASI at follow-up. By multivariate regression analysis, the presence of SVA (P = .029; odds ratio, 1.97; 95% confidence interval, 1.07 to 3.63) and an elevated DASI at baseline (P < .001; odds ratio, 1.05; 95% confidence interval, 1.03 to 1.07) were associated with a lack of improvement at follow-up. CONCLUSIONS: The detection of SVA was associated with failure of improvement in functional activity at follow-up after coronary intervention.

Angioplasty, Balloon↗