Stent development and local drug delivery.

Stent implantation has become the new standard angioplasty procedure. In-stent re-stenosis remains the major limitation of coronary stenting. Re-stenosis is related to patient-, lesion- and procedure-specific factors. Patient-specific factors can not be influenced to any extent. Procedure-specific factors are affected by implantation technique and stent characteristics. Design and material influence vascular injury and humoral and cellular response. Radiation has been shown to have inhibitory effects on smooth muscle cell growth and neo-intima formation, but in clinical trials the outcome has been hampered by re-stenosis at the edges of the radioactive stent ('candy wrapper'). New approaches target pharmacological modulation of local vascular biology by local administration of drugs. This allows for drug application at the precise site and time of vessel injury. Systemic release is minimal and this may reduce the risk of toxicity. The drug and the delivery vehicle must fulfil pharmacological, pharmacokinetic and mechanical requirements and the application of eluting degradable matrices seems to be a possible solution. Numerous pharmacological agents with antiproliferative properties are currently under clinical investigation, e.g. actinomycin D, rapamycin or paclitaxel. Another approach is for stents to be made of biodegradable materials as an alternative to metallic stents. Their potential long-term complications, such as in-stent re-stenosis and the inaccessibility of the lesion site for surgical revascularization, needs to be assessed. Current investigational devices and the line of (pre)clinical investigation are discussed in detail. Currently, there is little experimental, and only preliminary clinical, understanding of the acute and long-term effects of drug-eluting or biodegradable stents in coronary arteries. The clinical benefit of these approaches still has to be proven.

Angioplasty, Balloon, Coronary↗

Uncomplicated moderate coronary artery dissections after balloon angioplasty: good outcome without stenting.

OBJECTIVE: To study the relation between moderate coronary dissections, coronary flow velocity reserve (CFVR), and long term outcome. METHODS: 523 patients undergoing balloon angioplasty and sequential intracoronary Doppler measurements were examined as part of the DEBATE II trial (Doppler endpoints balloon angioplasty trial Europe). After successful balloon angioplasty, patients were randomised to stenting or no further treatment. Dissections were graded at the core laboratory by two observers and divided into four categories: none, mild (type A-B), moderate (type C), severe (types D to F). Patients with severe dissections (n = 128) or without available reference vessel CFVR (n = 139) were excluded. The remaining 256 patients were divided into two groups according to the presence (group A, n = 45) or absence (group B, n = 211) of moderate dissection. RESULTS: Following balloon angioplasty, there was no difference in CFVR between the two groups. At 12 months follow up, a higher rate of major adverse cardiac events was observed overall in group A than in group B (10 (22%) v 23 (11%), p = 0.041). However, the risk of major adverse events was similar in the subgroups receiving balloon angioplasty (group A, 6 (19%) v group B, 16 (16%), NS). Among group A patients, the adverse events risk was greater in those randomised to stenting (odds ratios 6.603 v 1.197, p = 0.046), whereas there was no difference in risk if the group was analysed according to whether the CFVR was < 2.5 or >/= 2.5 after balloon angioplasty. CONCLUSIONS: Moderate dissections left untreated result in no increased risk of major adverse cardiac events. Additional stenting does not improve the long term outcome.

Aortic Dissection↗

Acute changes of global and regional left ventricular function immediately after direct myocardial revascularization.

Direct myocardial revascularization (DMR) has been proposed to treat patients with severe coronary artery disease who are not amenable for classical revascularization techniques such as percutaneous coronary intervention (PCI) or bypass surgery (CABG). Although recent reports suggest its benefit in alleviating patients' complaints in the long term, there is still a paucity of data on the immediate impact on regional and global myocardial functioning following this treatment. In this overview we discuss our own experience and provide a summary of other data currently available.

Coronary Disease↗

Reproducibility of neointima quantification with motorized intravascular ultrasound pullback in stented coronary arteries.

BACKGROUND: Intravascular ultrasound (IVUS) imaging has shown excellent reproducibility immediately after coronary stent implantation. However, the variability of measurements in lesions late after stent implantation, when neointima formation is present, has not been studied. Neointimal tissue is generally low echogenic and thus difficult to quantify. We therefore sought to analyze the reproducibility of morphometric measurements late after stent implantation. METHODS AND RESULTS: Fifty consecutive patients were investigated 6 months after Palmaz-Schatz stent implantation (motorized catheter pullback 0.5 mm/s). Two experienced investigators independently identified the stent area, lumen area, and neointimal area at different sites within the stent. Planimetric measurements were performed with commercially available software. Correlation coefficient and mean difference for corresponding measurements were calculated for the intraobserver and interobserver comparisons. Variability for the intraobserver and interobserver comparisons was similar. Observer agreement regarding the presence of neointimal hyperplasia was as high as 71% (interobserver comparison 62%). The mean difference for neointima area was 0.06 +/- 1.5 mm(2) (-0.6 +/- 1.5 mm(2)); mean differences for lumen area were 0.02 +/- 0.19 mm(2) (0.03 +/- 0.17 mm(2)) and for stent area 0.01 +/- 0.09 mm(2) (-0.02 +/- 0.12 mm(2)) (values for interobserver comparison are given in parentheses). Correlation between measurements was high for all structures: correlation coefficients were 0.66 (0.69) for neointima, 0.94 (0.95) for lumen, and 0.95 (0. 91) for stent area. CONCLUSIONS: Morphometric measurements of IVUS investigations with motorized IVUS pullback late after stent placement show good reproducibility. Intraobserver variability and interobserver variability are low. Differences for corresponding measurements were more pronounced for neointima area. Motorized catheter pullback guarantees high reliability of IVUS measurements and should be used routinely for clinical IVUS studies.

Aged↗

Influence of a history of smoking on short term (six month) clinical and angiographic outcome after successful coronary angioplasty.

OBJECTIVES: To assess the influence of smoking on restenosis after coronary angioplasty. DESIGN AND PATIENTS: The incidence of smoking on restenosis was investigated in 2948 patients. They were prospectively enrolled in four major restenosis trials in which quantitative angiography was used before and immediately after successful angioplasty and again at six months. RESULTS: Within the study population there were 530 current smokers, 1690 ex-smokers, and 728 non-smokers. Smokers were more likely to be men (85.9% v 87. 5% v 65.3%, current v ex- v non-, p < 0.001), to be younger (54.0 (9. 0) v 57.0 (9.1) v 59.9 (9.4) years, p < 0.001), to have peripheral vascular disease (7.2% v 5.5% v 2.3%, p < 0.001), and have sustained a previous myocardial infarction (42.9% v 43.9% v 37.9%, p = 0.022), but were less likely to be diabetic (9.1% v 9.5% v 12.6%, p = 0.043) or hypertensive (24.9% v 29.3% v 37.2, p < 0.001). There was no significant difference in the categorical restenosis rate (> 50% diameter stenosis) at six months (35.28% v 35.33% v 37.09%, current v ex- v non-), or the absolute loss (0.29 (0.54) v 0.33 (0.52) v 0. 35 (0.55) mm, respectively; p = 0.172). CONCLUSIONS: Although smokers have a lower incidence of known predisposing risk factors for atherosclerosis, they require coronary intervention almost six years earlier than non-smokers and three years earlier than ex-smokers. Once they undergo successful coronary angioplasty, there appears to be no evidence that smoking influences their short term (six month) outcome, but because of the known long term effects of smoking, patients should still be encouraged to discontinue the habit.

Age Factors↗

Coronary stent implantation in a septal perforator artery: case report and review of the literature.

Septal perforator arteries play an important role in the blood supply of the anterior interventricular septum. Their intramyocardial course makes them inaccessible for coronary bypass revascularization. Although modern catheter-based techniques might be superior to coronary bypass grafting in offering the most complete revascularization in selected patient populations, a systematic review of the literature revealed a paucity of data regarding the outcome of these patients. The present report describes coronary stent implantation in a dominant septal perforator artery and the analysis of the anatomic relationship between the stent and the intraventricular septum using a new imaging technique, catheter-based intracardiac ultrasound.

Arteries↗

Quantitative changes in reference segments during IVUS-guided stent implantation: impact on the criteria for optimal stent expansion.

Intravascular ultrasound is an established method to optimize stent implantation. Stent expansion is estimated from the relation between minimal in-stent cross-sectional area and reference lumen area. We analyzed the periprocedural lumen increment in the reference segments and its impact on intravascular ultrasound (IVUS) criteria for optimized stenting. Seventy-five consecutive patients were studied with a 2.9 Fr, 30-MHz system and motorized pullback (0.5 mm/sec). Lumen area was measured by planimetry; absolute and relative differences in area (delta area) were calculated. Lumen area increment for reference segments proximal and distal to the stent was 6.4% +/- 10.3% and 6.1% +/- 10.8%; 49/75 patients fulfilled all IVUS criteria for optimal stent expansion at the final IVUS assessment, and 10/75 patients met all the IVUS criteria in relation to the first measurement of reference lumen area, but not in relation to the final measurement of reference lumen area. During high-pressure dilatation within the stent, reference lumen increment is visible. If reference lumen planimetry is not repeated after additional high-pressure balloon inflation, the final relative stent expansion may be overestimated.

Angioplasty, Balloon, Coronary↗

IVUS analysis of the acute and long-term stent result using motorized pullback: intraobserver and interobserver variability.

Intravascular ultrasound imaging has become an established method for analysis of intra-coronary stents. We analyzed the reproducibility of morphometric measurements immediately and late after stent implantation and the variability in the selection of predefined sites during motorized catheter pullback. Fifty consecutive patients were investigated immediately and 6 months after Palmaz-Schatz stent implantation (motorized catheter pullback 0.5 mm/sec; 2.9 Fr; 30-MHz transducer). Two experienced investigators independently identified the proximal and distal reference, stent inlet, stent outlet, and the minimal in-stent area in each imaging run. The longitudinal distance between corresponding measurement sites was calculated. Lumen, stent, and vessel area were assessed by planimetry, mean difference was calculated. Long-term reproducibility was analyzed by comparison of measurements made at predefined sites within the stent, immediately and late after implantation. Observer agreement in identification of predefined measurement sites was high. Longitudinal distance between corresponding measurement sites was low and pronounced for the minimal in-stent lumen area. Variabilities for the intra- and interobserver comparison were similar. Values for interobserver comparison were given in brackets. Acute after stent implantation, the variability for the reference proximal was 4.9% (0.4%), distal -1.0% (-4.2%), minimal in-stent lumen -0.5% (1.3%). At follow-up, variability for the reference proximal was -11.0% (-2.2%), distal -1.0% (-2.3%), minimal in-stent lumen 1.9% (6.1%). Long-term reproducibility for the proximal stent inlet was 2.7% (observer 1) and -0.4% (observer 2), for the distal stent outlet 1.3% (observer 1), -3.0% (observer 2), respectively. IVUS investigations with motorized IVUS pullback in stented coronary segments show a low intra- and interobserver variability, both immediately and late after stent implantation. Absolute and relative area differences are low. Long-term reproducibility of measurements within predefined stent sites was high. Motorized catheter pullback guarantees high reliability of IVUS measurements and should be routinely used for clinical IVUS studies.

Blood Vessel Prosthesis Implantation↗

[Dobutamine stress echocardiography for assessment of intracoronary stent implantation].

UNLABELLED: Stress echocardiography has been shown to be a valuable noninvasive method for the diagnosis of restenosis after coronary angioplasty. To determine the usefulness of dobutamine stress echocardiography (DSE) for assessment of restenosis after intracoronary stent implantation, we studied 50 patients (59+/-10 years; 1-vessel disease, n=16; multivessel disease, n=34) after stent implantation. After 6 month, both DSE (5-40 mcg/kg/min, 0-1mg atropine) and angiography were performed within 48 hours and evaluated in a blinded fashion. Restenosis was defined by quantitative coronary angiography as minimal lumen diameter (LD) <50% of average reference LD. Diagnostic criteria of DSE were new or worsening wall motion abnormalities in corresponding perfusion territories during stress. Angiography revealed restenosis in 8 patients; one patient had a denovostenosis distal to the stented segment (8 x left anterior descending artery, 1 ACVB to the right coronary artery). In 6 of these 9 patients, DSE was positive (mean reduction of LD 88+/-7%; sensitivity 67%), in 3 patients negative (mean reduction of LD 62+/-7%, 1 x termination of DSE because of wall motion abnormalities in an area not supplied by the stented vessel). In 38 of 41 patients without restenosis, DSE showed no stress-induced wall motion abnormalities in the LV area supplied by the stented vessel (specificity 93%). CONCLUSIONS: DSE is a useful noninvasive method for detecting restenosis after intracoronary stent implantation. With negative DSE at follow-up, a functionally relevant stent restenosis is highly unlikely.

Adult↗

Impact of target lesion calcification on coronary stent expansion after rotational atherectomy.

BACKGROUND: Calcified lesions carry the risk of suboptimal stent expansion. The purpose of this study was to investigate the impact of target lesion calcification on intracoronary ultrasound (ICUS) guided stent expansion after rotational atherectomy. METHODS: Stent expansion was assessed by ICUS in 39 patients with the aid of the proximal stent/proximal reference lumen, the minimal stent/mean reference lumen, and the minimal stent/minor reference lumen ratios as well as the symmetry index. Thirty-nine stent implantations in uncalcified lesions served for comparison. RESULTS: Relative stent expansion ranged between 76.3% +/- 6.7% and 98.4% +/- 16.4%. Categorization according to an ICUS-derived arc of superficial lesion calcium of <180 degrees (average 102 +/- 74 degrees) or >180 degrees (average 248 +/- 71 degrees) revealed decreased stent symmetry in calcified lesions >180 degrees compared with the control group (P <.05). Despite a trend toward less expansion with increasing calcium load, no significant differences of the lumen area ratios between the study groups was present. CONCLUSION: Rotational atherectomy before ICUS-guided stent implantation enables adequate stent expansion even in significant superficial target lesion calcification.

Aged↗

Epicardial intimal thickening in transplant coronary artery disease and resistance vessel response to adenosine: a combined intravascular ultrasound and Doppler study.

BACKGROUND: Transplant coronary artery disease is the major factor limiting long-term survival after cardiac transplantation. Both intravascular ultrasound imaging (IVUS) and intracoronary flow studies have been used to assess the morphologic and functional importance of the disease. However, the impact of epicardial intimal thickening, as quantitated by IVUS, on the resistance vessel response to adenosine has not been explored. METHODS AND RESULTS: Seventy-six coronary arteries without angiographically overt coronary disease (diameter stenosis visually, < or =50%) were studied with both IVUS and intracoronary Doppler in 54 patients 0.5 to 127 months after transplantation. Mean intimal index and mean lumen cross-sectional area (CSA) were determined by IVUS, and the average was obtained for every coronary artery. Coronary flow average peak velocity (APV) was obtained by Doppler before and after administration of 16 microg adenosine to calculate coronary flow velocity reserve (CFVR) and coronary vascular resistance index (CVRI). The hyperemic pressure-flow velocity ratio (hyperemic mean aortic pressure/hyperemic APV) as an index of minimal coronary resistance was further derived. The intimal index (mean, 20.0+/-10%) did not correlate with either CFVR (mean, 2.9+/-0.7, r=.12) or CVRI (mean, 0.33+/-0.1, r=.16). However, a significant correlation between the intimal index and the hyperemic pressure-flow velocity ratio (mean, 1.52+/-0.47 mm Hg/cm/s, r=.74, P<.0001) was found. The hyperemic pressure-flow velocity ratio was not influenced by the presence or absence of left ventricular hypertrophy or a mild acute rejection period (International Society for Heart and Lung Transplantation grades IA and IB). CONCLUSIONS: This study shows that in patients without angiographically overt coronary disease, the degree of epicardial intimal thickening as quantified by IVUS did not predict the adenosine vasodilator response, when determined by commonly used parameters such as CFVR and CVRI. The hyperemic pressure-flow velocity ratio best reflected the functional significance of transplant coronary artery disease.

Adenosine↗

Serial follow-up after optimized ultrasound-guided deployment of Palmaz-Schatz stents. In-stent neointimal proliferation without significant reference segment response.

BACKGROUND: The effects of ultrasound-guided high-pressure stenting on late stent and reference segment dimensions are unknown. In this study, we report about angiographic and ultrasound measurements to assess the amount and distribution of neointimal ingrowth within the stent and the changes of plaque burden and dimensions within the reference segments. METHODS AND RESULTS: Sixty-eight consecutive patients with 72 lesions received single or multiple Palmaz-Schatz coronary stents with a standardized protocol for stent optimization under ultrasound guidance. The residual angiographic diameter stenosis was 3 +/- 12% (reference diameter, 3.16 +/- 0.61 mm). At follow-up 4.8 +/- 2.5 months later, angiography revealed a diameter stenosis of 27 +/- 21% with a restenosis rate of 15.3% (confidence interval: 7.8% to 25.6%). Lumen renarrowing within the stent was exclusively due to neointimal ingrowth; no stent compression was observed. The neointima covered 20 +/- 20% of the stent area and was more pronounced in the midportion of the stent. Volumetric assessment performed in 26 patients resulted in 13 +/- 14% or 65 +/- 28% of the stent volume occupied by neointimal ingrowth in patients without or with restenosis, respectively. Vessel remodeling had an impact on lumen dimensions only at reference sites but not within the stent. Plaque burden of 46 +/- 11% and 48 +/- 11% at the proximal and distal reference sites, respectively, did not show a relevant progression during the follow-up. CONCLUSIONS: Serial ultrasound analyses did not show any evidence of stent compression or relevant vessel remodeling. Restenosis was solely due to neointimal ingrowth. Despite a considerable plaque burden within the reference segments, there was no relevant progression of the disease adjacent to the stent.

Adult↗