Publications and source records attributed to Edward T Zellers.

7 recordsLinked to original sources

Chamber evaluation of a portable GC with tunable retention and microsensor-array detection for indoor air quality monitoring.

The evaluation of a novel prototype instrument designed for on-site determinations of VOC mixtures found in indoor working environments is described. The instrument contains a miniature multi-stage preconcentrator, a dual-column separation module with pressure-tunable retention capabilities, and an integrated array of three polymer-coated surface acoustic wave sensors. It was challenged with dynamic test-atmospheres of a set of 15 common indoor air contaminants at parts-per-billion concentrations within a stainless-steel chamber under a range of conditions. Vapours were reliably identified at a known level of confidence by combining column retention times with sensor-array response patterns and applying a multivariate statistical test of pattern fidelity for the chromatographically resolved vapours. Estimates of vapour concentrations fell within 7% on average of those determined by EPA Method TO-17, and limits of detection ranged from 0.2 to 28 ppb at 25 degrees C for 1 L samples collected and analyzed in <12 min. No significant humidity effects were observed (0-90% RH). Increasing the chamber temperature from 25 to 30 degrees C reduced the retention times of the more volatile analytes which, in turn, demanded alterations in the scheduling of column-junction-point pressure (flow) modulations performed during the analysis. Reductions in sensor sensitivities with increasing temperature were predictable and similar among the sensors in the array such that most response patterns were not altered significantly. Short-term fluctuations in concentration were accurately tracked by the instrument. Results indicate that this type of instrument could provide routine, semi-autonomous, near-real-time, multi-vapour monitoring in support of efforts to assess air quality in office environments.

Air Pollution, Indoor↗

First-generation hybrid MEMS gas chromatograph.

The fabrication, assembly, and initial testing of a hybrid microfabricated gas chromatograph (microGC) is described. The microGC incorporates capabilities for on-board calibration, sample preconcentration and focused thermal desorption, temperature-programmed separations, and "spectral" detection with an integrated array of microsensors, and is designed for rapid determinations of complex mixtures of environmental contaminants at trace concentrations. Ambient air is used as the carrier gas to avoid the need for on-board gas supplies. The microsystem is plumbed through an etched-Si/glass microfluidic interconnection substrate with fused silica capillaries and employs a miniature commercial pump and valve subsystem for directing sample flow. The latest performance data on each system component are presented followed by first analytical results from the working microsystem. Tradeoffs in system performance as a function of volumetric flow rate are explored. The determination of an 11-vapor mixture of typical indoor air contaminants in less than 90 s is demonstrated with projected detection limits in the low part-per-billion concentration range for a preconcentrated air-sample volume of 0.25 L.

Air↗

Limits of recognition for simple vapor mixtures determined with a microsensor array.

The "limit of recognition" (LOR) has been defined as the minimum concentration at which reliable individual vapor recognition can be achieved with a multisensor array, and methodology for determining the LORs of individual vapors probabilistically on the basis of sensor array response patterns has been reported. This article explores the problems of defining and evaluating LORs for vapor mixtures in terms of the absolute and relative component vapor concentrations, where the mixture must be discriminated from those component vapors and from the subset of possible lower-order component mixtures. Monte Carlo simulations and principal components regression analyses of an extant database of calibrated responses to a set of 16 vapors from an array of 6 diverse polymer-coated surface acoustic wave sensors are used to illustrate the approach and to examine trends in LOR values among the 120 possible binary mixtures and 560 possible ternary mixtures in the data set. At concentrations exceeding the LOD, 89% of the binary mixtures could be reliably recognized (<5% error) over some composite concentration range, while only 3% of the ternary mixtures could be recognized. Most binary mixtures could be recognized only if the constituent vapor relative concentration ratio, defined in terms of multiples of the LOD for each vapor, was < or =20. Correlations with the Euclidean distance(s) separating the normalized constituent vapor response vectors allow reasonably accurate predictions of the limiting recognizable mixture composition ranges for binary and ternary cases. Results are considered in the context of using microsensor arrays for vapor detection and recognition in microanalytical systems.

Journal Article↗

Adaptation and evaluation of a personal electronic nose for selective multivapor analysis.

The evaluation of a commercial, belt-mountable "electronic nose" modified for the rapid recognition and quantification of individual solvent vapors and simple vapor mixtures at low ppm concentrations is described. Marketed under the name VaporLab this direct-reading instrument was designed for qualitative determinations of the presence or absence of selected individual vapors and was adapted in this study for quantitative determinations of vapors and vapor-mixture components. Vapor samples are concentrated on a small adsorbent bed and then thermally desorbed for analysis by an array of four polymer-coated surface acoustic wave sensors. Tests were performed with 13 organic solvent vapors individually and in selected binary, ternary, and quaternary mixtures at concentrations ranging from 0.1 to 12 times the respective American Conference of Governmental Industrial Hygienists' (ACGIH) threshold limit value (TLV). Pattern recognition analyses yielded a library of response patterns to which subsequent actual and virtual (i.e., Monte-Carlo simulated) samples were compared to assess performance. Limits of detection >0.025 x TLV are achieved (based on the most sensitive sensors) for 0.25 L of preconcentrated air samples collected over a 2-min period. Individual vapors from different functional group classes can be recognized, quantified, and discriminated from other vapors with little error, and discrimination of the components of binary mixtures is possible where the component vapor response patterns are sufficiently different. Within-class individual vapor and binary-mixture discriminations are more difficult and most ternary and higher-order mixtures could not be analyzed with acceptable accuracy. Changes in ambient humidity have no effect on responses and changes in temperature lead to well-behaved and compensable changes in responses. Tests of fluctuating concentrations demonstrate the capability for accurately tracking short-term variations in exposure. Overall, results suggest that this instrument could serve effectively as a personal exposure monitor in previously characterized occupational environments with proper revisions in design.

Air Pollution, Indoor↗

Portable gas chromatograph with tunable retention and sensor array detection for determination of complex vapor mixtures.

A prototype portable gas chromatograph that combines a multiadsorbent preconcentrator/focuser, a tandem-column separation stage with individual column temperature control and junction point pressure modulation, and a detector consisting of an integrated array of polymer-coated surface acoustic wave microsensors is described. Using scheduled first-column stop-flow intervals and independent temperature programming of the two columns, it is possible to adjust the retention of eluting analyte vapors to maximize vapor recognition with the microsensor array and minimize the time of analysis. A retention window approach is combined with Monte Carlo simulations to guide retention tuning requirements and facilitate pattern recognition analyses. The determination of a 30-vapor mixture of common indoor air contaminants in < 10 min is demonstrated using ambient air as the carrier gas. Detection limits of < 10 ppb are achieved for the majority of compounds from a 1-L air sample on the basis of the most sensitive sensor in the array. Performance is assessed in the context of near-real-time indoor air quality monitoring applications.

Air Pollution, Indoor↗

Dual-chemiresistor GC detector employing monolayer-protected metal nanocluster interfaces.

The synthesis and testing of two gold-thiolate monolayer-protected (nano)clusters as interfacial layers on a dual-chemiresistor vapor sensor array are described. Responses (changes in dc resistance) to each of 11 organic solvent vapors are rapid, reversible, and linear with concentration at low vapor concentrations, becoming sublinear at higher concentrations. Limits of detection (LODs) range from 0.1 to 24 parts per million and vary inversely with solvent vapor pressure. When configured as a GC detector and used to analyze 0.5-L preconcentrated samples of the 11-vapor mixture, the array provides LODs of < or = 700 parts per trillion for most vapors, comparing favorably with those from an integrated array of polymer-coated surface acoustic wave sensors configured and tested similarly. This first report on the use of such an array as a GC detector shows that the combination of response patterns and GC retention times improves capabilities for vapor recognition compared to the sensor array alone or to single-detector GC systems. Spray-coated nanocluster thin films can be deposited reproducibly and exhibit response stability in air that ranges from fair to excellent for up to several months. Scaling the active device area down by a factor of 16 has no significant effect on sensitivity. Implications of these results for portable vapor sensing systems are discussed.

Journal Article↗

Multi-adsorbent preconcentration/focusing module for portable-GC/microsensor-array analysis of complex vapor mixtures.

A small multi-adsorbent preconcentration/focusing module for a portable GC with microsensor-array detector designed to determine complex mixtures of volatile and semi-volatile organic compounds encountered in indoor working environments is described. Candidate adsorbents were assessed on the basis of analyte thermal-desorption bandwidth and efficiency, chromatographic peak shape, and breakthrough volume against mixtures of organic compounds ranging over four orders of magnitude in vapor pressure. A capillary packed with just 12.3 mg of adsorbent material comprising Carbopack B (8 mg), Carbopack X (2.5 mg) and Carboxen 1000 (1.8 mg) provided the best tradeoff in operating variables, while maintaining sufficient capacity for a 1 L air sample containing a mixture of up to 43 compounds, each at 100 parts-per-billion, at an ambient relative humidity of up to 100%. On-column focusing and temperature programming were used to enhance chromatographic separations, and detection limits as low as 100 parts-per-trillion were achieved for a 1 L air sample using an integrated array of polymer-coated surface-acoustic-wave (SAW) sensors. Implications for field analysis of indoor air quality are emphasized.

Acoustics↗