Abstract

The "limit of recognition" (LOR) has been defined as the minimum concentration at which reliable individual vapor recognition can be achieved with a multisensor array, and methodology for determining the LORs of individual vapors probabilistically on the basis of sensor array response patterns has been reported. This article explores the problems of defining and evaluating LORs for vapor mixtures in terms of the absolute and relative component vapor concentrations, where the mixture must be discriminated from those component vapors and from the subset of possible lower-order component mixtures. Monte Carlo simulations and principal components regression analyses of an extant database of calibrated responses to a set of 16 vapors from an array of 6 diverse polymer-coated surface acoustic wave sensors are used to illustrate the approach and to examine trends in LOR values among the 120 possible binary mixtures and 560 possible ternary mixtures in the data set. At concentrations exceeding the LOD, 89% of the binary mixtures could be reliably recognized (<5% error) over some composite concentration range, while only 3% of the ternary mixtures could be recognized. Most binary mixtures could be recognized only if the constituent vapor relative concentration ratio, defined in terms of multiples of the LOD for each vapor, was < or =20. Correlations with the Euclidean distance(s) separating the normalized constituent vapor response vectors allow reasonably accurate predictions of the limiting recognizable mixture composition ranges for binary and ternary cases. Results are considered in the context of using microsensor arrays for vapor detection and recognition in microanalytical systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Meng-Da Hsieh, Edward T Zellers. 2004-04-01. Limits of recognition for simple vapor mixtures determined with a microsensor array.. https://doi.org/10.1021/ac035294w

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effectiveness of high-dose versus standard-dose influenza vaccines against hospitalisation according to frailty risk: a prespecified analysis of the randomised trial DANFLU-2.

BACKGROUND: Frailty is a major risk factor for influenza-related complications and can influence vaccine effectiveness. We aimed to assess the relative vaccine effectiveness (rVE) of high-dose (HD-IIV) versus standard-dose inactivated influenza vaccine (SD-IIV) in older adults aged 65 years or older according to frailty risk. METHODS: This study was a prespecified analysis of DANFLU-2, an open-label, individually randomised trial, conducted in Denmark during three consecutive influenza seasons (2022-23, 2023-24, and 2024-25). Adults aged 65 years or older were randomised (1:1) to the HD-IIV or SD-IIV group. The primary endpoint was hospitalisation for influenza or pneumonia. Frailty was defined according to the validated Hospital Frailty Risk Score (HFRS) based on ICD-10 codes within 10 years before randomisation. Participants were stratified into three HFRS categories, namely low (<5 points), intermediate (5-15 points), and high (>15 points) frailty risk. The rVE of HD-IIV versus SD-IIV against the primary endpoint was assessed across prespecified HFRS categories and treating HFRS as a continuous variable. Pearson's chi-square test was used to compare safety events across frailty risk groups and randomisation groups. FINDINGS: Among 332&#x2009;438 randomised participants (mean age 73&#xb7;7 years [SD 5&#xb7;8]; 161&#x2009;538 [48&#xb7;6%] were female), 276&#x2009;173 (83&#xb7;1%) had low frailty risk, 52&#x2009;395 (15&#xb7;8%) had intermediate frailty risk, and 3861 (1&#xb7;2%) had high frailty risk. The primary endpoint of hospitalisation for influenza or pneumonia occurred in 1424 (0&#xb7;5%) of 276&#x2009;173 participants with low frailty risk, 761 (1&#xb7;5%) of 52&#x2009;395 with intermediate frailty risk, and 163 (4&#xb7;2%) of 3861 with high frailty risk (relative risk [RR] for intermediate vs low frailty risk 2&#xb7;8 [95% CI 2&#xb7;6-3&#xb7;1]; RR for high vs low frailty risk 8&#xb7;2 [7&#xb7;0-9&#xb7;6]). HFRS as a continuous variable significantly modified the effect of HD-IIV versus SD-IIV against the primary endpoint with higher rVE estimates with increasing HFRS (pinteraction=0&#xb7;020). The rVE was 0&#xb7;2% (95% CI -10&#xb7;8 to 10&#xb7;2) among those with low frailty risk, 13&#xb7;1% (-0&#xb7;4 to 24&#xb7;8) among those with intermediate frailty risk, and 19&#xb7;9% (-10&#xb7;3 to 42&#xb7;1) among those with high frailty risk. No significant interaction was observed when HFRS was assessed according to the prespecified categorical frailty groups (pinteraction=0&#xb7;17). The proportion of participants with at least one serious adverse event increased across frailty risk groups (13&#x2009;366 [4&#xb7;8%] of 275&#x2009;795 for low frailty risk, 5475 [10&#xb7;5%] of 52&#x2009;315 for intermediate frailty risk, and 777 [20&#xb7;2%] of 3850 for high frailty risk; p<0&#xb7;0001), with similar proportions of serious adverse events in the HD-IIV and SD-IIV groups for each frailty risk group. INTERPRETATION: Among adults aged 65 years or older in Denmark, frailty risk might modify the effects of HD-IIV versus SD-IIV against hospitalisation for influenza or pneumonia, with higher rVE estimates with increasing frailty risk. These findings might support considering high-dose influenza vaccines for frail older adults. However, effect modification was not evident when frailty was assessed using prespecified categorical subgroups, and subgroup-specific estimates were imprecise, with 95% CIs crossing the null. These results should be considered exploratory, warranting further investigation. FUNDING: The DANFLU-2 trial was funded by Sanofi.

Journal Article↗