PubMed Health⌕ Search

Biomedical subjects

Eiichi Tamiya

Publications and source records attributed to Eiichi Tamiya.

At least 19 recordsLinked to original sources

Label-free protein biosensor based on aptamer-modified carbon nanotube field-effect transistors.

We have fabricated label-free protein biosensors based on aptamer-modified carbon nanotube field-effect transistors (CNT-FETs) for the detection of immunoglobulin E (IgE). After the covalent immobilization of 5'-amino-modified 45-mer aptamers on the CNT channels, the electrical properties of the CNT-FETs were monitored in real time. The introduction of target IgE at various concentrations caused a sharp decrease in the source-drain current, and a gradual saturation was observed at lower concentrations. The amount of the net source-drain current before and after IgE introduction on the aptamer-modified CNT-FETs increased as a function of IgE concentration. The detection limit for IgE was determined as 250 pM. We have also prepared CNT-FET biosensors using a monoclonal antibody against IgE (IgE-mAb). The electrical properties of the aptamer- and antibody-modified CNT-FETs were compared. The performance of aptamer-modified CNT-FETs provided better results than the ones obtained using IgE-mAb-modified CNT-FETs under similar conditions. Thus, we suggest that the aptamer-modified CNT-FETs are promising candidates for the development of label-free protein biosensors.

Aptamers, Nucleotide↗

Label-free immunosensor for prostate-specific antigen based on single-walled carbon nanotube array-modified microelectrodes.

We have fabricated a label-free electrochemical immunosensor using microelectrode arrays modified with single-walled carbon nanotubes (SWNTs). Label-free detection of a cancer marker, total prostate-specific antigen (T-PSA), was carried out using differential pulse voltammetry (DPV). The current signals, derived from the oxidation of tyrosine (Tyr), and tryptophan (Trp) residues, increased with the interaction between T-PSA on T-PSA-mAb covalently immobilized on SWNTs. The selectivity of our biosensor was challenged using bovine serum albumin (BSA) as the target protein. The detection limit for T-PSA was determined as 0.25 ng/mL. Since the cut-off limit of T-PSA between prostate hyperplasia and cancer is 4 ng/mL, the performance of our label-free electrochemical immunosensor seems promising for further clinical applications.

Biosensing Techniques↗

Multiple label-free detection of antigen-antibody reaction using localized surface plasmon resonance-based core-shell structured nanoparticle layer nanochip.

In this research, a localized surface plasmon resonance (LSPR)-based bioanalysis method for developing multiarray optical nanochip suitable for screening bimolecular interactions is described. LSPR-based label-free monitoring enables to solve the problems of conventional methods that require large sample volumes and time-consuming labeling procedures. We developed a multiarray LSPR-based nanochip for the label-free detection of proteins. The multiarray format was constructed by a core-shell-structured nanoparticle layer, which provided 300 nanospots on the sensing surface. Antibodies were immobilized onto the nanospots using their interaction with Protein A. The concentrations of antigens were determined from the peak absorption intensity of the LSPR spectra. We demonstrated the capability of the array measurement using immunoglobulins (IgA, IgD, IgG, IgM), C-reactive protein, and fibrinogen. The detection limit of our label-free method was 100 pg/mL. Our nanochip is readily transferable to monitor the interactions of other biomolecules, such as whole cells or receptors, with a massively parallel detection capability in a highly miniaturized package. We anticipate that the direct label-free optical immunoassay of proteins reported here will revolutionize clinical diagnosis and accelerate the development of hand-held and user-friendly point-of-care devices.

Antigen-Antibody Reactions↗

Circumventing air bubbles in microfluidic systems and quantitative continuous-flow PCR applications.

Polymerase chain reaction (PCR) is an essential part of research based on genomics or cell analysis. The development of a microfluidic device that would be suitable for high-temperature-based reactions therefore becomes an important contribution towards the integration of micro-total analysis systems (muTAS). However, problems associated with the generation of air bubbles in the microchannels before the introduction of the assay liquid, which we call the "initial start-up" in this study, made the flow irregular and unstable. In this report, we have tried to address these problems by adapting a novel liquid-flow method for high-temperature-based reactions. A PDMS-based microfluidic device was fabricated by soft-lithography techniques and placed on a cartridge heater. The generation of the air bubbles was prevented by introducing the fluorinated oil, an inert and highly viscous liquid, as the cap just before the introduction of the sample solutions into the microchannels. The technique was applied for continuous-flow PCR, which could perform PCR on-chip in a microfluidic system. For the evaluation of practical accuracy, plasmid DNA that serves as a reference molecule for the quantification of genetically modified (GM) maize was used as the template DNA for continuous-flow PCR. After PCR, the products were collected in a vial and analyzed by gel electrophoresis to confirm the accuracy of the results. Additionally, quantitative continuous-flow PCR was performed using TaqMan technology on our PCR device. A laser detection system was also used for the quantitative PCR method. We observed a linear relationship between the threshold cycle (Ct) and the initial DNA concentration. These results showed that it would be possible to quantify the initial copies of the template DNA on our microfluidic device. Accurate quantitative DNA analysis in microfluidic systems is required for the integration of PCR with muTAS, thus we anticipate that our device would have promising potential for applications in a wide range of research.

DNA↗

Label-free electrochemical immunoassay for the detection of human chorionic gonadotropin hormone.

Here we report on a new and rapid immunoassay for the label-free voltammetric detection of human chorionic gonadotropin hormone (hCG) in urine. Monitoring the changes in the current signals of antibodies (Abs) before and after the binding of the antigen (Ag) provides the basis for an immunoassay that is simple, rapid, and cost-effective. Since hCG is found at highly elevated levels in pregnant female urine with the range of 30,000-200,000 mIU/mL (approximately 30-200 nM) by 8-10 weeks into pregnancy, its label-free electrochemical detection was achieved by using our method. The coverage of the electrode surface with the Ab and the incubation time with the target Ag were optimized for the detection of hCG. The limit of detection of our method was calculated to be 15 pM (n = 3, approximately 15 mIU/mL) in synthetic hCG samples and 20 pM (n = 3, approximately 20 mIU/mL) in human urine. The electrochemical results for the detection of hCG in the urine samples were in agreement with the results obtained using a reference system, enzyme-linked immunosorbent assay. Further research about the intrinsic electroactivity of Abs and their target molecules would surely provide new and sensitive screening assays, as well as extensive data regarding their interaction mechanisms.

Antibodies, Monoclonal↗

Rapid and onsite BOD sensing system using luminous bacterial cells-immobilized chip.

A BOD monitoring system based on a bio-chip which immobilized luminous bacterium in micrometer-order holes were arrayed and fabricated by micro-machine techniques, was developed. The acrylic chip (3 cmx3 cm) comprises nine micro-holes (diameter: 700 microm or 1 mm, depth: 100 microm) arranged in a three by three array. Cells of the marine luminous bacterium, Photobacterium phosphoreum IFO 13896, which was grown at 15 degrees C for 15 h, were immobilized with 3% or 15% sodium alginate gel. BOD standard solutions or actual sample solution (approximately 10 microl) was fallen onto the cell-arrayed chip, and then the chip was incubated at 25 degrees C for 25 min. After incubation, bioluminescence from the each hole was gray-scaled and measured by a chemi-imager or newly developed onsite-type-monitoring system using a digital camera and a mobile-type personal computer. BOD values less than 16 ppm could detect by the chip, in particular, linear relationship at the concentrations between 0 and 16 ppm could be observed when luminous cells were immobilized with 3% sodium alginate gel. Steady bioluminescence was observed on the chip in the presence of BOD standard solution (GGA solution) which contained mineral elements. Furthermore, simultaneous detection of BOD values in various samples could be employed in the single chip. These results showed that the monitoring system with bio-chip could achieve high-through-put and onsite BOD detection. Our newly developed onsite-type BOD detection system which was used a digital camera and a (mobile) laptop computer was applied to measure and detect organic pollution due to biodegradable substances in wastewater treatment system. The same performance as the chemi-imager system was obtained for data of bioluminescence. The obtained BOD values showed a similar correlation with that of the conventional method for BOD determination (BOD5). These results suggested for successful achievement of high-though-put and onsite detection of BOD in practical.

Biosensing Techniques↗

A novel enhancement assay for immunochromatographic test strips using gold nanoparticles.

The immunochromatographic assay is a well-known and convenient diagnostic system. In this report, the development of a novel enhancement assay for the test strips is described. Additionally, this highly sensitive immunochromatographic assay was applied to detect human chorionic gonadotropin hormone (HCG) as the model case. The primary antibody-conjugated gold nanoparticles were used as the enhancer of the standard method. The primary antibodies were immobilized within a defined detection zone (test line) on the diagnostic nitrocellulose membrane. The secondary antibodies were conjugated with colloidal gold nanoparticles. In combination with an effective sample pretreatment, the gold-conjugated antibodies and the primary antibodies formed a sandwich complex with the target protein. Within the test line, the sandwich complex was immobilized, and furthermore, concentrated by the enhancer resulting in a localized surface plasmon resonance (LSPR) phenomenon and a distinct red color on the test line. The intensity of color of the red test line (signal intensity), which correlated directly with the concentration of the target protein in the standard or spiked samples, was assessed visually and by computer image analysis using a three-determination analysis. Under optimum conditions, the limit of detection (LOD) for HCG assay was 1 pg/mL. When using human serum, 10 pg/mL of HCG could be detected. We have also spiked total prostate-specific antigen (TPSA) in female serum. The LOD for TPSA was determined as 0.2 ng/mL. With this method, the quantitative determination of the target protein could be completed in less than 15 min. Our novel immunochromatographic strips using the enhancing method based on LSPR of gold nanoparticles are useful as a rapid and simple screening method for the detection of important analytes for medical applications, environmental monitoring, food control, and biosecurity.

Chorionic Gonadotropin↗

Electrochemical genosensor based on peptide nucleic acid-mediated PCR and asymmetric PCR techniques: Electrostatic interactions with a metal cation.

The unique structure of peptide nucleic acids (PNAs), linking the N-(2-aminoethyl)glycine units that create a neutral backbone, and prevent it from acting as a primer for DNA polymerase, has been utilized in an electrochemical biosensor scheme for simple and sensitive detection of hybridization. When the PNA is targeted against a single-nucleotide polymorphism (SNP) or wild-type site on the gene, PNA-mediated polymerase chain reaction (PCR) clamping method effectively blocks the formation of a PCR product. In our report, PNA probe for PCR clamping was targeted against the wild-type site of alcohol dehydrogenase. The electrostatic interactions between the negatively charged DNA and neutral PNA molecules with redox-active metal cation cobalt(III)hexamine ([Co(NH3)6]3+) were monitored using differential pulse voltammetry. The electrostatic binding of [Co(NH3)6]3+ to DNA provided the basis for the discrimination against PNA/PNA, PNA/DNA, and DNA/DNA hybrid molecules. We have optimized the experimental conditions, such as probe concentration, [Co(NH3)6]3+ concentration, accumulation time for [Co(NH3)6]3+, and target concentration. A new pretreatment method has also been employed to allow fast and simple detection of hybridization reaction between the PCR amplicon and the probe on glassy carbon electrode (GCE) surface. This method was based on the application of a high-temperature treatment (95 degrees C, 5 min), followed by a 1-min incubation in the presence of DNA primers. The excess concentration of DNA primers prevented the rehybridization of the denatured strands, while enabling the target gene sequence to bind with the immobilized probe. Additionally, asymmetric PCR was employed to detect the presence of genetically modified organism in standard Roundup Ready soybean samples. The amplicons of asymmetric PCR, which were predominantly single-stranded DNA as a result of unequal primer concentration, hybridized with the DNA probe on the sensor surface efficiently. The attachment of long single-strands on GCE surface caused the accumulation of [Co(NH3)6]3+ and a high current response. Here, we report a versatile method that would allow for simple and rapid analysis of nucleic acids in combination with PNA-mediated PCR and asymmetric PCR techniques by using an electrochemical genosensor.

Base Sequence↗

Resin-based micropipette tip for immunochromatographic assays in urine samples.

A novel bioanalysis system based on immunochromatography was developed in connection with a nitrocellulose resin modified micropipette tip, such as ZipTip. The sandwich-type immunoassay was applied to our bioanalysis system. The simple handling of the micropipette enabled us to increase the sample volume and detect low concentrations of target antigens in urine samples. In addition, the washing procedure could also be performed easily to reduce the background signal levels. For analytical evaluations, the color intensity was captured by a flatbed scanner, and processed by a software. We have achieved the detection of human chorionic gonadotropin (hCG) and prostate-specific antigen (PSA). The detection limit of hCG was 0.5 ng/ml (0.05 ng/tip), which is comparable to that of other conventional immunochromatographic systems. Moreover, the detection of PSA was greatly improved over the existing systems with the application of different sample volumes, such as 1 ng/ml (0.2 ng/tip) in a 200 microl sample volume, and 1 ng/ml (0.3 ng/tip) in 300 microl sample volume. Our bioanalysis system is a promising candidate for application to point-of-care tests with its simple handling and high sensitivity.

Antibodies, Monoclonal↗

Damage to and recovery of coastlines polluted with C-heavy oil spilled from the Nakhodka.

The damage to and recovery of the Japanese coastline from Suzu, Ishikawa Prefecture to Mikuni, Fukui Prefecture was investigated visually over three years after a C-heavy oil spill from the Russian tanker "Nakhodka" in the Japan Sea on January 2, 1997. The beached C-heavy oil tended to remain for a long time on coasts of bedrock and boulder/cobble/pebble but it was removed rapidly from coasts of gravel/sand and man-made structures such as concrete tetrapods. On the coasts of the latter type, wave energy appeared to be the main force removing the oil. One year after the spill, C-heavy oil tended to remain strongly on the sheltered coasts of bedrock and boulder/cobble/pebble. Even on coasts of this type, the contamination was remarkably absent by 2 years after the spill. The concentration levels of polycyclic aromatic hydrocarbons (PAHs) in oil lumps, sand and seawater were monitored during 3 years following the spill. The concentrations of PAHs having 2 or 3 rings decreased more quickly than did those of PAHs having 4 or more rings, suggesting that volatilization was the main cause of the decrease. On the other hand, the concentrations of PAHs having 4 to 6 rings did not start to decrease until 7 months after the spill. The main cause of the decrease seemed to be photolysis. The concentration of BaP in seawater off the polluted coasts was high 1 month after the spill and then decreased. Three years after the spill, the level fell to the sub ng/L level, which was as low as the level in seawater along unpolluted clean coasts in Japan. The concentration of BaP in greenling was higher than the normal level only during the first two months after the spill. These results suggest that the coastlines in Ishikawa and Fukui Prefectures that were polluted with C-heavy oil recovered in 3 years.

Animals↗

Single-cell microarray for analyzing cellular response.

Detection of cellular response by measuring intracellular calcium, (Ca2+)i with Ca2+-dependent fluorescent dye are standard approaches to detect ligand-stimulated cells and to study signaling through ligand/receptor interaction. We describe a single-cell microarray system to analyze cellular response of individual cells such as lymphocytes using microchamber array chips. The single-cell microarray chip is made from polystyrene with over 30,000 microchambers, which can accommodate only single cells. Lymphocytes derived from mouse spleen or human blood were spread on the microarray, and over 80% of the microchambers achieved single-cell status. Stimulation of B-cells through antigen receptors on the microarray allowed us to detect activated B-cells by comparing the states of single B-cells before and after stimulation with antigen, which is disabled for flow cytometry. In addition, this novel method demonstrated retrieval of positive single B-cells from microchambers by a micromanipulator and achieved antibody DNA analysis. The system is suitable for high-throughput analysis of intracellular Ca2+ response at the single-cell level and is applicable to screen antigen-specific lymphocytes for making specific monoclonal antibody.

Amino Acid Sequence↗

Estimation of maturity of compost from food wastes and agro-residues by multiple regression analysis.

The composting process of food wastes and tree cuttings was examined on four composting types composed from two kinds of systems and added mixture of microorganisms. The time courses of 32 parameters in each composting type were observed. The efficient composting system was found to be the static aerated reactor system in comparison with the turning pile one. Using the multiple regression analysis of all the data (159 samples) obtained from this study, some parameters were selected to predict the germination index (GI) value, which was adopted as a marker of compost maturity. For example, using the regression model generated from pH, NH(4)(+) concentration, acid phosphatase activity, and esterase activity of water extracts of the compost, GI value was expressed by the multi-linear regression equation (p<0.0001). High correlations between the measured GI value and the predicted one were made in each type of compost. As a result of these observations, the compost maturity might be predicted by only sensing of the water extract at the composting site without any requirements for a large-size equipment and skill, and this prediction system could contribute to the production of a stable compost in wide-spread use for the recycling market.

Acid Phosphatase↗

Label-free detection of peptide nucleic acid-DNA hybridization using localized surface plasmon resonance based optical biosensor.

The development of label-free optical biosensors for DNA and other biomolecules has the potential to impact life sciences as well as screening in medical and environmental applications. In this report, we developed a localized surface plasmon resonance (LSPR) based label-free optical biosensor based on a gold-capped nanoparticle layer substrate immobilized with peptide nucleic acids (PNAs). PNA probe was designed to recognize the target DNA related to tumor necrosis factor. The nanoparticle layer was formed on a gold-deposited glass substrate by the surface modified silica nanoparticles using silane-coupling reagent. The optical properties of gold-capped nanoparticle layer substrate were characterized through monitoring the changes in the absorbance strength, as the thickness of the biomolecular layer increased with hybridization. The detection of PNA-DNA hybridization with target oligonucleotides and PCR-amplified real samples were performed with a limit of detection value of 0.677 pM target DNA. Selective discrimination against a single-base mismatch was also achieved. Our LSPR-based biosensor with the gold-capped nanoparticle layer substrate is applicable to the design of biosensors for monitoring of the interaction of other biomolecules, such as proteins, whole cells, or receptors with a massively parallel detection capability in a highly miniaturized package.

Biosensing Techniques↗

A rapid label-free electrochemical detection and kinetic study of Alzheimer's amyloid beta aggregation.

We present the first electrochemical detection, characterization, and kinetic study of the aggregation of Alzheimer's disease (AD) amyloid beta peptides (Abeta-40, Abeta-42) using three different voltammetric techniques at a glassy carbon electrode (GCE). This method is based on detecting changes in the oxidation signal of tyrosine (Tyr) residue. As the peptides aggregate, there are structure conformational changes, which affect the degree of exposure of Tyr to the molecular surface of the peptides. The results show significant differences in the aggregation process between the two peptides, and these correlate highly with established techniques. The method is rapid and label-free, and the principle can be universally applied to other protein aggregation studies related to diseases, such as Huntington's, Parkinson's, and Creutzfeldt Jacob (CJD). This method could also be explored in screening for the effectiveness of AD therapies.

Alzheimer Disease↗

Constraining the connectivity of neuronal networks cultured on microelectrode arrays with microfluidic techniques: a step towards neuron-based functional chips.

In vitro culture of small neuronal networks with pre-defined topological features is particularly desirable when the electrical activity of such assemblies can be monitored for long periods of time. Indeed, it is hoped that such networks, with pre-determined connectivity, will provide unique insights into the structure/function relationship of biological neural networks and their properties of self-organization. However, the experimental techniques that have been developed so far for that purpose have either failed to provide very long-term pattern definition and retention, or they have not shown potential for integration into more complex microfluidic devices. To address this problem, three-dimensional microfluidic systems in poly(dimethylsiloxane) (PDMS) were fabricated and used in conjunction with both custom-made and commercially available planar microelectrode arrays (pMEAs). Various types of primary neuronal cell cultures were established inside these systems. Extracellular electrical signals were successfully recorded from all types of cells placed inside the patterns, and this bioelectrical activity was present for several weeks. The advantage of this approach is that it can be further integrated with microfluidic devices and pMEAs to yield, for example, complex neuron-based biosensors or chips for pharmacological screening.

Action Potentials↗

Escherichia coli single-strand binding protein-DNA interactions on carbon nanotube-modified electrodes from a label-free electrochemical hybridization sensor.

An electrochemical hybridization biosensor based on the intrinsic oxidation signals of nucleic acids and proteins has been designed, that makes use of the unique binding event between Escherichia coli single-strand binding protein (SSB) and single-stranded DNA (ssDNA). The voltammetric signal from guanine oxidation significantly decreased upon binding of SSB to single-stranded oligonucleotides (probe), anchored on a single-walled carbon nanotube (SWCNT) -modified screen-printed carbon electrode (SPE). Simultaneously, oxidation of the tyrosine (Tyr) and tryptophan (Trp) residues of the SSB protein increased upon binding of the SSB protein to ssDNA and ss-oligonucleotides. After the hybridization, SSB did not bind to the double helix form, and the guanine signal could be observed along with the disappearance of the oxidation signal of the protein. The amplification of intrinsic guanine and protein oxidation signals by SWCNT, and a washing step with sodium dodecylsulfate, enabled the specific detection of a point mutation. Monitoring the changes in the guanine and protein signals upon hybridization greatly simplified the detection procedure. The detection limit of 0.15 microg/ml target DNA can be applied to genetic assays. To the best of our knowledge, this is the first work that utilizes the monitoring of SSB-DNA interactions on a solid transducer for the electrochemical detection of DNA hybridization by using intrinsic oxidation signals.

Base Sequence↗

Microchamber array based DNA quantification and specific sequence detection from a single copy via PCR in nanoliter volumes.

A novel method for DNA quantification and specific sequence detection in a highly integrated silicon microchamber array is described. Polymerase chain reaction (PCR) mixture of only 40 nL volume could be introduced precisely into each chamber of the mineral oil layer coated microarray by using a nanoliter dispensing system. The elimination of carry-over and cross-contamination between microchambers, and multiple DNA amplification and detection by TaqMan chemistry were demonstrated, for the first time, by using our system. Five different gene targets, related to Escherichia coli were amplified and detected simultaneously on the same chip by using DNA from three different serotypes as the templates. The conventional method of DNA quantification, which depends on the real-time monitoring of variations in fluorescence intensity, was not applied to our system, instead a simple method was established. Counting the number of the microchambers with a high fluorescence signal as a consequence of TaqMan PCR provided the precise quantification of trace amounts of DNA. The initial DNA concentration for Rhesus D (RhD) gene in each microchamber was ranged from 0.4 to 12 copies, and quantification was achieved by observing the changes in the released fluorescence signals of the microchambers on the chip. DNA target could be detected as small as 0.4 copies. The amplified DNA was detected with a CCD camera built-in to a fluorescence microscope, and also evaluated by a DNA microarray scanner with associated software. This simple method of counting the high fluorescence signal released in microchambers as a consequence of TaqMan PCR was further integrated with a portable miniaturized thermal cycler unit. Such a small device is surely a strong candidate for low-cost DNA amplification, and detected as little as 0.4 copies of target DNA.

Biosensing Techniques↗