PubMed Health⌕ Search

Biomedical subjects

Elizabeth M Dax

Publications and source records attributed to Elizabeth M Dax.

10 recordsLinked to original sources

Commercial enzyme immunoassay adapted for the detection of antibodies to hepatitis C virus in dried blood spots.

BACKGROUND: Dried blood spots (DBS) provide a convenient method for blood sample collection in many settings where the prevalence of infection with hepatitis C virus (HCV) is increasing. Consequently, HCV assays are required that produce reliable results using samples derived from DBS. OBJECTIVES AND STUDY DESIGN: The optimum buffer for the elution of samples from DBS was selected and the performance of a commercial enzyme immunoassay (EIA) was evaluated using these DBS eluates and paired plasma samples. RESULTS: DBS with paired plasma samples were compared using this modified commercial EIA, which was found to have an estimated sensitivity and specificity of approximately 100% for detecting anti-HCV antibodies in DBS. CONCLUSION: A DBS-based assay for the detection of antibodies to HCV will prove valuable for collecting epidemiological data in the field or in under resourced settings.

Blood Specimen Collection↗

Humoral immune response to primary rubella virus infection.

An assay capable of distinguishing between the immune response generated by recent exposure to rubella virus and the immune response existing as a result of past exposure or immunization is required for the diagnosis of primary rubella virus infection, especially in pregnant women. Avidity assays, which are based on the premise that chaotropic agents can be used to selectively dissociate the low-avidity antibodies generated early in the course of infection, have become routinely used in an effort to accomplish this. We have thoroughly investigated the immunological basis of an avidity assay using a viral lysate-based assay and an enzyme-linked immunosorbent assay (ELISA) based on a peptide analogue of the putative immunodominant region of the E1 glycoprotein (E1208-239). The relative affinities of the antibodies directed against E1208-239 were measured by surface plasmon resonance and were found to correlate well with the avidity index calculated from the ELISA results. We found that the immune response generated during primary rubella virus infection consists of an initial low-affinity peak of immunoglobulin M (IgM) reactivity followed by transient peaks of low-avidity IgG3 and IgA reactivity. The predominant response is an IgG1 response which increases in concentration and affinity progressively over the course of infection. Incubation with the chaotropic agent used in the avidity assay abolished the detection of the early low-affinity peaks of IgM, IgA, and IgG3 reactivity while leaving the high-affinity IgG1 response relatively unaffected. The present study supported the premise that avidity assays based on appropriate antigens can be useful to confirm primary rubella virus infection.

Amino Acid Sequence↗

HIV testing in 2006: issues and methods.

Infection with HIV and subsequent development of AIDS is a pandemic. The Joint United Nations Program on HIV/AIDS together with the WHO and many relevant funding bodies demand that those infected should be reliably identified so that people who need, or will need, therapy may be provided for over time. This means that there is a renewed interest in testing for HIV and in laboratories' performances and quality. Whatever the conditions under which testing is performed, and whatever the levels of training, the tests and their outcomes must exhibit equivalent, high standards of performance and reliable results. This is regardless of whether testing is conducted in the most sophisticated laboratories (either diagnostic or transfusion screening) to voluntary testing and counseling centers where those conducting testing may not be technically trained. This is not currently the case, especially in some places where HIV is most prevalent. To achieve uniformly high performance standards, quality assurance programs are imperative, but currently not sufficiently valued to be well supported with adequate funding or human resources. Accurate HIV testing is a cornerstone of blood safety, diagnosis of infection, patient management and surveillance.

Animals↗

Evaluation of three immunoassays used for detection of anti-rubella virus immunoglobulin M antibodies.

Three automated assays (Abbott AxSYM, Bayer ADVIA Centaur, and bioMerieux VIDAS) used for the detection of rubella virus-specific immunoglobulin M were evaluated. A total of 57 samples from individuals with evidence of infection with rubella virus were used to estimate sensitivity, and 220 samples from blood donors and individuals attending an antenatal clinic who had no evidence of recent infection were used to estimate specificity. Seroconversion panels comprising an additional 31 samples from four individuals were used to determine clinical sensitivity. Samples containing potentially cross-reacting substances were also tested. The sensitivities of the three assays ranged from 84.2 to 96.5%, and the specificities ranged from 96.8 to 99.9%. The Abbott AxSYM assay detected more reactive samples than the other two assays when a panel of 57 positive samples was tested. Bayer ADVIA Centaur detected more reactive samples in the seroconversion panels than the other two assays. All three assays evaluated reported a reactive result in 1 or more of the 48 samples containing potentially cross-reacting analytes. The assays demonstrated comparable performance in testing of a well-characterized panel of samples.

Antibodies, Viral↗

Incidence immunoassay for distinguishing recent from established HIV-1 infection in therapy-naive populations.

OBJECTIVE: To identify a specific marker of recent HIV-1 infection. DESIGN: The humoral immune response in individuals recently infected with HIV-1 was followed by analysing the antibody isotype-specific response generated to HIV-1 antigens in sequential samples collected during and following seroconversion. METHODS: Antibody isotype-specific HIV-1 Western blots were analysed to identify interactions indicative of recent HIV-1 infection. These responses were further quantified using an antibody isotype-specific enzyme-linked immunoabsorbent assay based on recombinant HIV-1 antigens. RESULTS: During maturation of the immune response to HIV-1 infection, a rapid and enduring IgG1 isotype response was seen to all the major proteins transcribed by env, gag and pol. An early transient peak of IgG3 reactivity to p24 was observed over an interval of approximately 1-4 months following HIV-1 infection. The presence of IgG3 reactivity to p24 permitted established infection to be distinguished from recently infected individuals during this time period. CONCLUSION: An assay for anti-p24 IgG3 reactivity would provide an estimate of the incidence of HIV infection that may be applicable for epidemiological surveys as well as for monitoring new infections during vaccine trials and for managing treatment programmes.

Acute Disease↗

Validation of assembled nucleic acid-based tests in diagnostic microbiology laboratories.

Medical microbiology and virology laboratories use nucleic acid tests (NAT) to detect genomic material of infectious organisms in clinical samples. Laboratories choose to perform assembled (or in-house) NAT if commercial assays are not available or if assembled NAT are more economical or accurate. One reason commercial assays are more expensive is because extensive validation is necessary before the kit is marketed, as manufacturers must accept liability for the performance of their assays, assuming their instructions are followed. On the other hand, it is a particular laboratory's responsibility to validate an assembled NAT prior to using it for testing and reporting results on human samples. There are few published guidelines for the validation of assembled NAT. One procedure that laboratories can use to establish a validation process for an assay is detailed in this document. Before validating a method, laboratories must optimise it and then document the protocol. All instruments must be calibrated and maintained throughout the testing process. The validation process involves a series of steps including: (i) testing of dilution series of positive samples to determine the limits of detection of the assay and their linearity over concentrations to be measured in quantitative NAT; (ii) establishing the day-to-day variation of the assay's performance; (iii) evaluating the sensitivity and specificity of the assay as far as practicable, along with the extent of cross-reactivity with other genomic material; and (iv) assuring the quality of assembled assays using quality control procedures that monitor the performance of reagent batches before introducing new lots of reagent for testing.

DNA, Bacterial↗

Advances in laboratory testing for HIV.

In 2004, the diagnosis of established human immunodeficiency virus (HIV) infection can be made with close to 100% assurity. The extraordinarily engineered performances of HIV-screening assays are unprecedented. The well-established confirmatory tests performed by well-versed laboratories using criteria that are well understood in order to interpret the results of these tests give highly accurate outcomes of diagnostic testing strategies. Furthermore, the ability to monitor the progress of the infection and the viral pathogenesis is possible through the use of tests that quantify viral load or the peripheral CD4+ T-cells and other lymphocyte sub-type levels. Newer laboratory testing mechanisms, such as assessment of reverse transcriptase activity and sophisticated cell staining and flow cytometric analyses, have been used to map disease processes and progress on a research level and may be used in future to fine-tune therapy and to follow disease progression in even greater detail. Regulation of all HIV tests is of the highest level in Australia. In-house tests will be expected to conform to the levels specified for commercially produced tests.

Clinical Laboratory Techniques↗

Sensitivity of HCV RNA and HIV RNA blood screening assays.

BACKGROUND: The FDA requirement for sensitivity of viral NAT methods used in blood screening is a 95-percent detection limit of 100 copies per mL, whereas the NAT screening system should have a sensitivity of at least 5000 copies per mL per individual donation. According to the Common Technical Specifications of the European Directive 98/79/EC for in vitro diagnostics, viral standard dilutions (calibrated against the WHO standard) should be tested at least 24 times for a statistically valid assessment of the 95-percent detection limit. STUDY DESIGN AND METHODS: Viral standard dilution panels (PeliCheck, VQC-CLB) were prepared for HCV RNA genotypes 1 and 3 and for HIV RNA genotypes B and E. In a multicenter study, 23 laboratories tested the panels all together in 8 to 91 test runs per NAT method. RESULTS: The following 95-percent detection limits (and 95% CIs) were found on the HCV RNA genotype 1 reference panels (shown as geq/mL): Gen-Probe TMA, 85 (64-118); AmpliScreen, 126 (83-225); AmpliScreen with NucliSens Extractor, 21 (13-44); Amplicor with NucliSens Extractor, 69 (50-102), and Amplicor with Qiagen extraction technology, 144 (74-102). On HIV RNA genotype B dilution panels, the following 95-percent detection limits were found (shown as geq/mL): Gen-Probe TMA, 31 (20-52); AmpliScreen, 126 (67-311); AmpliScreen with NucliSens Extractor, 37 (23-69), and NucliSens QL assay, 123 (51-566). HIV RNA genotype E panels were detected with equal sensitivity as HIV RNA genotype B panels. In the Gen-Probe TMA assay, the 50-percent detection limits on HIV RNA type B and type E were 3.6 (2.6-5.0) and 3.9 (2.4-5.8) geq per mL, respectively. The HCV RNA genotype 1 and 3 standards were detected with equal sensitivity. CONCLUSION: The differences in sensitivity between NAT assays can be explained by the input of isolated viral nucleic acid in the amplification reactions. The FDA requirements for sensitivity of NAT blood screening assays can be met by the Gen-probe TMA, as well as by the AmpliScreen assays, particularly when combined with the NucliSens Extractor.

Adsorption↗

External quality assessment program for Chlamydia trachomatis diagnostic testing by nucleic acid amplification assays.

We report the results from 57 Australian diagnostic laboratories testing two external quality assessment panels using either the Roche Amplicor Chlamydia trachomatis test (R-PCR) or the Abbott LCx Chlamydia trachomatis assay (A-ligase chain reaction [LCR]). Panel samples were either normal urine spiked with Chlamydia trachomatis antigen or clinical urine specimens. There was no significant difference between laboratories or between assays in detection of C. trachomatis-positive clinical samples. Only at the lower limit of detection of the assays did the R-PCR demonstrate increased sensitivity over the A-LCR in the detection of C. trachomatis antigen. However, it was found that single-sample testing could lead to decreased test sensitivity. Detection of the presence of inhibitors of nucleic acid amplification differed between laboratories.

Australia↗