PubMed Health⌕ Search

Biomedical subjects

Enrique J Fernández

Publications and source records attributed to Enrique J Fernández.

6 recordsLinked to original sources

Three-dimensional adaptive optics ultrahigh-resolution optical coherence tomography using a liquid crystal spatial light modulator.

A liquid crystal programmable phase modulator (PPM) is used as correcting device in an adaptive optics system for three-dimensional ultrahigh-resolution optical coherence tomography (UHR OCT). The feasibility of the PPM to correct high order aberrations even when using polychromatic light is studied, showing potential for future clinical use. Volumetric UHR OCT of the living retina, obtained with up 25,000A-scans/s and high resolution enables visualization of retinal features that might correspond to groups of terminal bars of photoreceptors at the external limiting membrane.

Humans↗

Study on the effects of monochromatic aberrations in the accommodation response by using adaptive optics.

The effect of asymmetric monochromatic aberrations in the accommodation response was studied by using an adaptive optics (AO) system. This approach permits the precise modification of ocular aberrations during accommodation. The AO system is composed of a real-time Hartmann-Shack wavefront sensor and a membrane deformable mirror with 37 independent actuators. The accommodation response was measured in two subjects with their normal aberrations and with the asymmetric aberrations terms corrected. We found a significant and systematic increase in the response accommodation time, and a reduction in the peak velocity, in both subjects when the aberrations were corrected in real time. However, neither the latency time nor the precision of the accommodation were affected. These results may indicate that the monochromatic aberrations play a role in driving the accommodation response.

Accommodation, Ocular↗

Neural compensation for the eye's optical aberrations.

A fundamental problem facing sensory systems is to recover useful information about the external world from signals that are corrupted by the sensory process itself. Retinal images in the human eye are affected by optical aberrations that cannot be corrected with ordinary spectacles or contact lenses, and the specific pattern of these aberrations is different in every eye. Though these aberrations always blur the retinal image, our subjective impression is that the visual world is sharp and clear, suggesting that the brain might compensate for their subjective influence. The recent introduction of adaptive optics to control the eye's aberrations now makes it possible to directly test this idea. If the brain compensates for the eye's aberrations, vision should be clearest with the eye's own aberrations rather than with unfamiliar ones. We asked subjects to view a stimulus through an adaptive optics system that either recreated their own aberrations or a rotated version of them. For all five subjects tested, the stimulus seen with the subject's own aberrations was always sharper than when seen through the rotated version. This supports the hypothesis that the neural visual system is adapted to the eye's aberrations, thereby removing somehow the effects of blur generated by the sensory apparatus from visual experience. This result could have important implications for methods to correct higher order aberrations with customized refractive surgery because some benefits of optimizing the correction optically might be undone by the nervous system's compensation for the old aberrations.

Adaptation, Physiological↗

Are optical aberrations during accommodation a significant problem for refractive surgery?

PURPOSE: To study the limits to a perfect ideal customized wavefront correction due to the change of aberrations during accommodation. METHODS. We measured the dynamic changes of ocular aberrations during accommodation in normal eyes with a real-time Hartmann-Shack wavefront sensor. Those results were used in computer simulations to predict the benefit of a perfect customized correction. RESULTS: Due to the continuous changes of the aberrations over time, an ideal perfect static correction will not provide stable aberration-free optics. For example, when the eye accommodates to near objects, due to the changing aberrations, the eye will become aberrated again. An alternative correction using the aberration pattern for a slightly accommodated condition could provide a better-correction in a larger accommodative range, although at the cost of non-perfect correction for far vision. CONCLUSIONS: Due to the dynamic nature of ocular optics, a static perfect correction, for instance performed in customized refractive surgery, would not remain perfect for every condition occurring during normal accommodation.

Accommodation, Ocular↗

Adaptive optics visual simulator.

PURPOSE: To develop a prototype instrument that uses adaptive optics to introduce virtually any desired aberration profile in a subject's eye. At the same time, the instrument could be used to evaluate the subject's spatial vision for each controlled aberration profile. This "aberration testing station" or "visual simulator" allows us to study the relationship between specific aberrations and visual quality. METHODS: The apparatus uses infrared light to measure the wavefront aberration of the system plus the eye with a Hartmann-Shack wavefront sensor. Defocus is added (or removed) with a computer-controlled, motorized optometer, while higher order aberrations are introduced by a 37-channel membrane deformable mirror. A parallel viewing channel is used for visual testing with the instrument. Visual acuity, contrast sensitivity, and other visual tests are performed under normal viewing for each desired aberration profile. RESULTS: The range of defocus that can be added is nearly unlimited, while the maximum amount of other aberration modes is restricted to approximately 0.5 microm, depending on mode. Pure modes or any selected combination of modes can be produced with high repeatability and precision (usually better than 0.05 microm), and the system works for pupil diameters up to 6 mm (with a natural pupil). CONCLUSIONS: The adaptive optics visual simulator is a powerful, non-invasive tool to evaluate how aberrations affect vision. In addition, it can be used for the interactive design and testing of new ophthalmic devices, and for the simulation of visual outcomes in customized refractive surgery.

Astigmatism↗

Adaptive optics for vision: the eye's adaptation to point spread function.

PURPOSE: Despite the fact that ocular aberrations blur retinal images, our subjective impression of the visual world is sharp, which suggests that the visual system compensates for subjective influence. If the brain adjusts for specific aberrations of the eye, vision should be clearest when looking through a subject's typical wave aberration rather than through an unfamiliar one. We used adaptive optics techniques to control the eye's aberrations in order to evaluate this hypothesis. METHODS: We used adaptive optics to produce point spread functions (PSFs) that were rotated versions of the eye's typical PSF by angles in 45 degrees intervals. Five normal subjects were asked to view a stimulus with their own PSF or with a rotated version, and to adjust the magnitude of the aberrations in the rotated case to match the subjective blur of the stimulus to that seen when the wave aberration was in typical orientation. RESULTS: The magnitude of the rotated wave aberration required to match the blur with the typical wave aberration was 20% to 40% less, indicating that subjective blur for the stimulus increased significantly when the PSF was rotated. CONCLUSION: These results support the hypothesis that the neural visual system is adapted to an eye's aberrations and has important implications for correcting higher order aberrations with customized refractive surgery or contact lenses. The full visual benefit of optimizing optical correction requires that the nervous system compensate for the new correction.

Diagnostic Techniques, Ophthalmological↗