PubMed Health⌕ Search

PubMed · 12361172

Adaptive optics visual simulator.

Abstract

PURPOSE: To develop a prototype instrument that uses adaptive optics to introduce virtually any desired aberration profile in a subject's eye. At the same time, the instrument could be used to evaluate the subject's spatial vision for each controlled aberration profile. This "aberration testing station" or "visual simulator" allows us to study the relationship between specific aberrations and visual quality. METHODS: The apparatus uses infrared light to measure the wavefront aberration of the system plus the eye with a Hartmann-Shack wavefront sensor. Defocus is added (or removed) with a computer-controlled, motorized optometer, while higher order aberrations are introduced by a 37-channel membrane deformable mirror. A parallel viewing channel is used for visual testing with the instrument. Visual acuity, contrast sensitivity, and other visual tests are performed under normal viewing for each desired aberration profile. RESULTS: The range of defocus that can be added is nearly unlimited, while the maximum amount of other aberration modes is restricted to approximately 0.5 microm, depending on mode. Pure modes or any selected combination of modes can be produced with high repeatability and precision (usually better than 0.05 microm), and the system works for pupil diameters up to 6 mm (with a natural pupil). CONCLUSIONS: The adaptive optics visual simulator is a powerful, non-invasive tool to evaluate how aberrations affect vision. In addition, it can be used for the interactive design and testing of new ophthalmic devices, and for the simulation of visual outcomes in customized refractive surgery.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Enrique J Fernández, Silvestre Manzanera, Patricia Piers, Pablo Artal. Adaptive optics visual simulator.. https://doi.org/10.3928/1081-597x-20020901-27

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Mathematical model of corneal surface smoothing after laser refractive surgery.

PURPOSE: To construct a quantitative model of corneal surface smoothing after laser ablation for refractive correction. DESIGN: Experimental study, interventional case series, and meta-analysis of literature. METHODS: A theory of epithelial smoothing in response to corneal contour change is derived from differential equations that describe epithelial migration, growth, and loss. Computer simulations calculate the effects on postoperative epithelial thickness, topography, refraction, and spherical aberration. Model parameter is matched with laser in situ keratomileusis (LASIK) outcome in literature and in a retrospective study of primary spherical myopic (77 eyes) and hyperopic (19 eyes) corrections. Surgically induced refractive change was the main outcome measure. RESULTS: Simulated epithelial remodeling after myopic ablation produces central epithelial thickening, reduction in achieved correction, and induction of oblate spherical aberration. Simulation of hyperopic ablation shows peripheral epithelial thickening, a larger reduction in correction, and induction of prolate spherical aberration. Simulation using a minus cylinder laser ablation pattern shows decreased astigmatism correction and increased hyperopic shift. In the LASIK series, linear regression of achieved correction vs ablation setting in hyperopic and minus cylinder corrections shows slopes of 0.97, 0.71, and 0.74, respectively. These clinical results match model predictions when the smoothing constant is set at 0.32, 0.63, and 0.55 mm, respectively. CONCLUSIONS: Epithelial thickness modulations after ablation can be modeled mathematically to explain clinically observed regression and induction of aberration. The cornea appears to smooth over ablated features smaller than approximately 0.5 mm. The model provides an approach for designing ablation patterns that precompensate for the smoothing to improve final outcome.

Astigmatism↗

Corneal ectasia detected 32 months after LASIK for correction of myopia and asymmetric astigmatism.

We report a case of corneal ectasia detected 32 months after laser in situ keratomileusis (LASIK) for correction of -4.25 diopters (D) of myopia associated with -2.00 D of regular but slight asymmetric astigmatism. The patient retained stable visual acuity for 15 months postoperatively. The preoperative corneal thickness was 540 microm, and the postablation untouched stroma was assumed to be 290 microm. Although a rare complication of LASIK, corneal ectasia can occur, and there is no consensus regarding how much stroma should be left intact to avoid it. Until we have a better understanding of corneal strength, we think surface photorefractive keratectomy or laser-assisted subepithelial keratectomy ablations should be considered instead of LASIK in borderline cases.

Astigmatism↗