PubMed Health⌕ Search

Biomedical subjects

Eric Champion

Publications and source records attributed to Eric Champion.

4 recordsLinked to original sources

Cadmium fixation by synthetic hydroxyapatite in aqueous solution--thermal behaviour.

This study deals with the mechanism of the cadmium uptake by synthetic hydroxyapatite (HA: Ca10(PO4)6(OH)2) in aqueous solution. The rate of cadmium fixation by hydroxyapatite was investigated at 10 and 50 degrees C using batch experiments. Inductively coupled plasma atomic emission spectrometry, X-ray diffraction, FT-IR spectroscopy and electron microscopy were used to characterize the starting HA and the samples. The thermal behaviour of the powders was determined with the help of three thermoanalytical techniques (TGA, DTA, and MS) and temperature programmed X-ray diffraction. Cadmium immobilization kinetics can be divided into two steps: substitution of Ca2+ ions by Cd2+ in the HA lattice at the particle's surface, followed by their incorporation into the hydroxyapatite bulk. This results in the formation of an apatite solid solution, which is very important because in this way decontamination and storage can be performed with the same material.

Cadmium↗

Quantitative kinetic analysis of gene expression during human osteoblastic adhesion on orthopaedic materials.

Little information was found in the literature about the expression on hydroxyapatite (HA) materials of genes specific of cellular adhesion molecules although more were found on titanium-based substrates. Hence, the goal of this work was to study by a kinetic approach from 30 min to 4 days the adhesion of Saos-2 cells on microporous (mHA) and non-microporous hydroxyapatite (pHA) in comparison to polished titanium. Our strategy associated the visualization of adhesion proteins inside the cells by immunohistochemistry and the quantitative expression of genes at mRNA level by real-time PCR. The cell morphology was assessed using scanning electron microscopy and the number of cells thanks to biochemical techniques. The cellular attachment was the highest on mHA from 30 min to 24 h although the cell growth on mHA was the lowest after 4 days. Generally, the Saos-2 osteoblastic cells morphology on mHA was radically different than on other surfaces with the particularity of the cytoplasmic edge, which appeared un-distinguishable from the surface. The revelation by specific antibodies of proteins of the cytoskeleton (actin) and the focal adhesions (FAK, phosphotyrosine) confirmed that adhesion and spreading were different on the 3 materials. The actin stress fibres were less numerous and shorter on mHA ceramics. Cells had more focal contacts after 4 h on mHA compared to other substrates but less after 24 h. The highest values of total proteins were extracted from mHA at 0.5 and 24 h and from pHA at 1, 4, and 96 h. The alphav and beta1 integrin, actin, FAK, and ERK gene expression were found to be different with adhesion time and with materials. C-jun expression was comparable on mHA, titanium and plastic but was largely higher than on pHA at 0.5 and 1 h. On the contrary, c-fos expression was the highest on pHA after 0.5 h and the lowest after 1h. This difference between c-fos and c-jun expression on pHA after 0.5 h could be related to the fact that these two genes may differ in their signalling pathways. The expression of the alkaline phosphatase gene after 4 days was lower on mHA compared to other materials demonstrating that the microstructure of the mHA ceramic was not favourable to Saos-2 cells differentiation. Finally, it was demonstrated in this study that HA and titanium surfaces influence as well gene expression at early times of adhesion as the synthesis of adhesion proteins but also proliferation and differentiation phases. Indeed, the signal transduction pathways involved in adhesion of Saos-2 cells on HA and titanium were confirmed by the sequential expression of alphav and beta1 integrins, FAK, and ERK genes followed by the expression of c-jun and c-fos genes for proliferation and alkaline phosphatase gene for differentiation.

Base Sequence↗

Influence of hydroxyapatite microstructure on human bone cell response.

Microstructure of calcium phosphate ceramics has been shown to influence long-term in vitro cellular events like proliferation and differentiation, and to favor bone integration in vivo. As long-term cellular events are known to be dependent of early cell adhesion events, we decided to study the in vitro influence of the microstructure of a microporous hydroxyapatite (mHA) and a nonmicroporous hydroxyapatite (pHA) ceramic on serum protein adsorption and SaOs-2 human bone cells attachment after 30 min, 1, 4, and 24 h and cell growth after 96 h. Plastic coverslips were used as controls. Hydroxyapatite composition of mHA and pHA was confirmed by X-ray diffraction and Fourier transform infra-red spectroscopy. The surface energies of ceramics were calculated from contact-angle measurements in di-iodomethane, water or complete culture medium. The total surface energy was 44.8 mJ/m(2) for pHA and 48.7 mJ/m(2) for plastic. The contact-angle measurement was impossible on mHA likely because they displayed 12% of open microporosity, pHA ceramic exhibiting only closed pores (2.5%). Moreover, the roughness amplitude was largely higher on mHA (Sa = 4.35 microm) than on pHA (Sa = 0.065 microm) and plastic (Sa = 0.042 microm). Three different techniques were used to evaluate protein adsorption on the ceramics. SDS-PAGE of desorbed proteins demonstrated that more proteins desorbed from mHA (66.02 microg/m(2)) than from pHA (17.2 microg/m(2)) or plastic (0.08 microg/m(2)). A new method was used to evaluate in situ the quantity of adsorbed total proteins: the temperature-programmed desorption (TPD) analysis coupled with mass spectrometry. The TPD analysis confirmed that 10-fold more proteins adsorbed on mHA compared with those on pHA. A direct immunolabeling on ceramics revealed than more fibronectin and serum albumin adsorbed on microporous ceramic than on dense ceramic. The morphology of SaOs-2 cells was the same on all the substrates after 30 min. At later time points, cell morphology on mHA was radically different than on other surfaces, with the particularity of the cytoplasmic edge that appeared undistinguishable from the surface. Only the extremity of the cells and lamellipodia were visible. Cells seemed like "adsorbed" by the mHA surface, whereas on plastic and pHA surfaces the cells displayed classical aspects of polygonal spreading. The cells displayed on mHA the highest initial attachment potential after 30 min, 1, 4, 24 h but the lower proliferation potential after four days. This study confirms that a microporous ceramic surface can modulate the adsorption of proteins and further the adhesion and proliferation of human bone cells.

Adsorption↗

Removal of surface by-products from sintered hydroxyapatite: effect of a chelation treatment on fibronectin adsorption and cell adhesion.

It was observed that fibronectin precipitates when deposited on hydroxyapatite (HA) ceramics. Fibronectin's known affinity for calcium and the composition of the ceramic itself suggested that calcium release could be the main cause of this aggregation effect. It was then decided to investigate the effect of a surface chelation treatment on fibronectin adsorption, and MG63 cell adhesion, onto porous ceramics of hydroxyapatite (HA), beta-tricalcium phosphate (beta-TCP), and HA/TCP biphasic material (BCP). Those ceramics were immersed in an EDTA solution and the effect of this treatment on the material composition was assayed. X-ray diffraction data showed the presence of alpha- and beta-TCP phases in HA and BCP materials, which were both completely removed by the chelation treatment in the case of HA. On BCP, alpha-TCP was removed and beta-TCP partially dissolved. The TCP material, which was pure beta-TCP, underwent a mass loss, but no change in composition was observed. Adhesion of MG63 cells was overall higher on the fibronectin-coated EDTA-treated HA material, but was especially enhanced on EDTA-treated HA. Changes in surface morphologies, as compared with the use of scanning electron microscopy, did not seem to be related to the effects observed. The EDTA treatment proved to be a very efficient way of removing by-products of HA sintered materials, and thus enhancing the biocompatibility of the material.

Adsorption↗