PubMed Health⌕ Search

PubMed · 16628709

Influence of hydroxyapatite microstructure on human bone cell response.

Abstract

Microstructure of calcium phosphate ceramics has been shown to influence long-term in vitro cellular events like proliferation and differentiation, and to favor bone integration in vivo. As long-term cellular events are known to be dependent of early cell adhesion events, we decided to study the in vitro influence of the microstructure of a microporous hydroxyapatite (mHA) and a nonmicroporous hydroxyapatite (pHA) ceramic on serum protein adsorption and SaOs-2 human bone cells attachment after 30 min, 1, 4, and 24 h and cell growth after 96 h. Plastic coverslips were used as controls. Hydroxyapatite composition of mHA and pHA was confirmed by X-ray diffraction and Fourier transform infra-red spectroscopy. The surface energies of ceramics were calculated from contact-angle measurements in di-iodomethane, water or complete culture medium. The total surface energy was 44.8 mJ/m(2) for pHA and 48.7 mJ/m(2) for plastic. The contact-angle measurement was impossible on mHA likely because they displayed 12% of open microporosity, pHA ceramic exhibiting only closed pores (2.5%). Moreover, the roughness amplitude was largely higher on mHA (Sa = 4.35 microm) than on pHA (Sa = 0.065 microm) and plastic (Sa = 0.042 microm). Three different techniques were used to evaluate protein adsorption on the ceramics. SDS-PAGE of desorbed proteins demonstrated that more proteins desorbed from mHA (66.02 microg/m(2)) than from pHA (17.2 microg/m(2)) or plastic (0.08 microg/m(2)). A new method was used to evaluate in situ the quantity of adsorbed total proteins: the temperature-programmed desorption (TPD) analysis coupled with mass spectrometry. The TPD analysis confirmed that 10-fold more proteins adsorbed on mHA compared with those on pHA. A direct immunolabeling on ceramics revealed than more fibronectin and serum albumin adsorbed on microporous ceramic than on dense ceramic. The morphology of SaOs-2 cells was the same on all the substrates after 30 min. At later time points, cell morphology on mHA was radically different than on other surfaces, with the particularity of the cytoplasmic edge that appeared undistinguishable from the surface. Only the extremity of the cells and lamellipodia were visible. Cells seemed like "adsorbed" by the mHA surface, whereas on plastic and pHA surfaces the cells displayed classical aspects of polygonal spreading. The cells displayed on mHA the highest initial attachment potential after 30 min, 1, 4, 24 h but the lower proliferation potential after four days. This study confirms that a microporous ceramic surface can modulate the adsorption of proteins and further the adhesion and proliferation of human bone cells.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Myriam Rouahi, Olivier Gallet, Eric Champion, Joseph Dentzer, Pierre Hardouin, Karine Anselme. 2006. Influence of hydroxyapatite microstructure on human bone cell response.. https://doi.org/10.1002/jbm.a.30682

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Three-dimensional porous nano-hydroxyapatite@gelatin composite as efficient adsorbent for uranyl ion removal from low-level radioactive wastewater.

The contamination of water resources by uranyl (UO22+) ions poses significant environmental and health risks, requiring the development of efficient and sustainable remediation strategies. Adsorption-based techniques have emerged as promising approaches in the field of UO22+ removal, but the design of cost-effective, high-capacity, and environmentally friendly adsorbents remains challenging. In this study, a three-dimensional porous nano-hydroxyapatite@gelatin (nHAP@Ge) composite was synthesized through glutaraldehyde cross-linking, combining the structural stability of Ge with the high uranium affinity of nHAP. The optimized nHAP@Ge, with a nHAP:Ge mass ratio of 1:0.5, exhibited exceptional UO22+ removal efficiency (97 %), along with high adsorption capacity (364.03 mg/g). Systematic characterizations using scanning electron microscopy (SEM), thermogravimetric analysis (TGA), Fourier transform infrared (FT-IR) spectroscopy, and X-ray photoelectron spectroscopy (XPS) methods revealed that the porous structure and surface functional groups (-OH, Ca2+, and PO43-) of the material synergistically contributed to binding UO22+ species. Furthermore, the incorporation of nHAP into the Ge framework resulted in enhanced thermal stability while significantly improving the UO22+ adsorption performance. This work presents a scalable, eco-friendly, and recyclable strategy for the effective treatment of uranium-contaminated water, with potential applications in nuclear wastewater treatment and environmental remediation.

Adsorption↗

Dual radiolabeling to study protein adsorption competition in relation with hemocompatibility.

Human fibrinogen (Fg) and albumin (HSA) were labeled with (3)H and (14)C, respectively. Dual counting allowed the adsorbed amount of the two proteins to be determined simultaneously. Single adsorption, adsorption of the two proteins in competition, but also exchange (substitution by molecules of the same nature) and displacement (desorption under the action of the other protein) experiments were performed on two model surfaces, glass and polystyrene (PS), as well as on pure polyvinylchloride (PVC-s) and on PVC from blood bag (PVC-b). As expected, the adsorbed amount of a single protein is higher on a hydrophobic compared to a hydrophilic surface. When the two proteins are adsorbed in competition, they are found in equal proportion on glass, while HSA is twice more abundant than Fg on PS and PVC-s and about six times more abundant on PVC-b. This trend is related to an increase of the water contact angle of the substrates. For PVC-b, the contact angle is affected by the presence of aliphatic components exposed at the extreme surface, as determined by angle-resolved X-ray photoelectron spectroscopy. In exchange and displacement experiments, the first adsorbed molecules remain dominating on PS while they can be removed from glass. Given the known importance of HSA and Fg adsorption for the fate of materials placed in contact with blood, the method described in this paper may be used as a first approach to orient the design of surfaces with improved hemocompatibility.

Adsorption↗

Effective immobilization of subunit protein in mesoporous silica modified with ethanol.

Ethoxylated FSM-type mesoporous silica (folded-sheet mesoporous material) with a pore diameter of 6.2 nm (FSM6.2) remarkably enhances rigidly of the structure in aqueous solutions. The esterified material could be used successfully as an adsorbent to accommodate subunit protein, methemoglobin (Fe(3+)). Furthermore, methemoglobin (Fe(3+)) in the pores of ethoxy-FSM is maintained a peroxidase activity similar to the native, indicating methemoglobin retains its fore subunit structure in the pores of FSM6.2.

Adsorption↗