PubMed Health⌕ Search

Biomedical subjects

Erik H Anderson

Publications and source records attributed to Erik H Anderson.

3 recordsLinked to original sources

Soft X-ray microscopy at a spatial resolution better than 15 nm.

Analytical tools that have spatial resolution at the nanometre scale are indispensable for the life and physical sciences. It is desirable that these tools also permit elemental and chemical identification on a scale of 10 nm or less, with large penetration depths. A variety of techniques in X-ray imaging are currently being developed that may provide these combined capabilities. Here we report the achievement of sub-15-nm spatial resolution with a soft X-ray microscope--and a clear path to below 10 nm--using an overlay technique for zone plate fabrication. The microscope covers a spectral range from a photon energy of 250 eV (approximately 5 nm wavelength) to 1.8 keV (approximately 0.7 nm), so that primary K and L atomic resonances of elements such as C, N, O, Al, Ti, Fe, Co and Ni can be probed. This X-ray microscopy technique is therefore suitable for a wide range of studies: biological imaging in the water window; studies of wet environmental samples; studies of magnetic nanostructures with both elemental and spin-orbit sensitivity; studies that require viewing through thin windows, coatings or substrates (such as buried electronic devices in a silicon chip); and three-dimensional imaging of cryogenically fixed biological cells.

Biological Science Disciplines↗

Design, fabrication, and characterization of high-efficiency extreme-ultraviolet diffusers.

As the development of extreme-ultraviolet (EUV) lithography progresses, interest grows in the extension of traditional optical components to the EUV regime. Because of the strong absorption of EUV by most materials and because of its extremely short wavelength, however, it is difficult to implement many components that are commonplace in the longer-wavelength regimes. One such example is the diffuser that is often implemented with ordinary ground glass in the visible light regime. Here we demonstrate the fabrication of reflective EUV diffusers with high efficiency within a controllable bandwidth. Using these techniques, we have fabricated diffusers with efficiencies exceeding 10% within a moderate angular single-sided bandwidth of approximately 0.06 rad.

Journal Article↗

High resolution 3D x-ray diffraction microscopy.

We have imaged a 2D buried Ni nanostructure at 8 nm resolution using coherent x-ray diffraction and the oversampling phasing method. By employing a 3D imaging reconstruction algorithm, for the first time we have experimentally determined the 3D structure of a noncrystalline nanostructured material at 50 nm resolution. The 2D and 3D imaging resolution is currently limited by the exposure time and the computing power, while the ultimate resolution is limited by the x-ray wavelengths. We believe these results pave the way for the development of atomic resolution 3D x-ray diffraction microscopy.

Microscopy↗