PubMed Health⌕ Search

Biomedical subjects

Ernest Sturdik

Publications and source records attributed to Ernest Sturdik.

5 recordsLinked to original sources

Oxidation of liposomal membrane suppressed by flavonoids: quantitative structure-activity relationship.

Antioxidant activity of the set of 12 flavonoids in heterogeneous membrane system of dioleoyl phosphatidylcholine liposomes stressed by peroxidative damage induced by 2,2'-azobis-(2-amidinopropane)hydrochloride azoiniciator and evaluated by the thiocyanate method was assessed. Antioxidant activity (pIC(50)) was correlated with 19 molecule parameters calculated for the minimum energy conformers of the compounds tested. The linear regression analysis revealed that the parameter of hydration energy E(HYDR) (R = -0.747) was the best predictor of antioxidant activity in a liposomal system.

Flavonoids↗

Improved selectivity of microbial biosensor using membrane coating. Application to the analysis of ethanol during fermentation.

A ferricyanide mediated microbial biosensor for ethanol detection was prepared by surface modification of a glassy carbon electrode. The selectivity of the whole Gluconobacter oxydans cell biosensor for ethanol determination was greatly enhanced by the size exclusion effect of a cellulose acetate (CA) membrane. The use of a CA membrane increased the ethanol to glucose sensitivity ratio by a factor of 58.2 and even the ethanol to glycerol sensitivity ratio by a factor of 7.5 compared with the use of a dialysis membrane. The biosensor provides rapid and sensitive detection of ethanol with a limit of detection of 0.85 microM (S/N=3). The selectivity of the biosensor toward alcohols was better compared to previously published enzyme biosensors based on alcohol oxidase or alcohol dehydrogenases. The biosensor was successfully used in an off-line monitoring of ethanol during batch fermentation by immobilized Saccharomyces cerevisiae cells with an initial glucose concentration of 200 g l(-1).

Biofilms↗

Amperometric urea biosensor based on urease and electropolymerized toluidine blue dye as a pH-sensitive redox probe.

The electropolymerized toluidine blue film deposited on the glassy carbon electrode show amperometrically detectable pH sensitivity. This feature of polytoluidine blue (PTOB) film was used for a construction of an amperometric urea biosensor. We have observed a linear shift of the formal redox potential with increasing pH value between 4 and 8 giving the slope of 81 mV(Delta) pH(-1). Polytoluidine blue film has had a significantly increased stability and higher electrochemical activity compared to the adsorbed monomeric dye. The polytoluidine blue urea biosensor has been operating at a working potential of -200 mV vs. SCE. The sensitivity of the biosensor was 980 nA mM(-1) cm(-2). The biosensor showed linearity in concentration range up to 0.8 mM with the detection limit of 0.02 mM (S/N=3).

Biosensing Techniques↗

Indirect evidence of direct electron communication between the active site of galactose oxidase and a graphite electrode.

Bi-enzymatic biosensor based on galactose oxidase (GalOD) and horseradish peroxidase (HRP) using ferrocene as an efficient mediator was constructed. When a dependence of a working potential on the sensor performance was examined, an unusual behaviour was observed. With increasing of an applied working potential a lower concentration of substrate to attain full linear range was needed. A fully linear dependence from the first substrate addition was observed at and above the working potential of 150 mV. This activation of the biosensor response by an applied working potential very well corresponds with a formal potential of GalOD (156 mV). When a membrane prevented GalOD access to the electrode surface was applied, no activation effect of a working potential on the sensor performance was observed. Thus, it can be assumed that direct electron communication between GalOD and the electrode occurred.

Binding Sites↗

Monitoring of ethanol during fermentation using a microbial biosensor with enhanced selectivity.

The present study is concerning the construction of ferricyanide-mediated Gluconobacter oxydans cell ethanol biosensor. The size exclusion effect of a cellulose acetate membrane was used for elimination of glucose interferences during ethanol assays in real samples. A typical response time of the biosensor was 13 s with a high sensitivity of 3.5 microA mM(-1). The microbial biosensor exhibits a very low detection limit of 0.85 microM and a wide linear range from 2 to 270 microM. The operational stability was excellent. During 8.5 h of repetitive ethanol assays, no decrease in the sensor sensitivity was observed. The biosensor was successfully used in the off-line monitoring of ethanol fermentation with a good agreement with HPLC measurements (R(2)=0.998).

Biosensing Techniques↗