Plane-wave fluorescence tomography with adaptive finite elements.

We present three-dimensional fluorescence yield tomography of a tissue phantom in a noncontact reflectance imaging setup. The method employs planar illumination with modulated light and frequency domain fluorescence measurements made on the illumination plane. An adaptive finite-element algorithm is used to handle the ill-posed and computationally demanding inverse image reconstruction problem. Tomographic images of fluorescent targets buried at 1-2 cm depths from the illumination surface demonstrate the feasibility of fluorescence tomography from reflectance tomography in clinically relevant tissue volumes.

Algorithms↗

Evaluation of ingredient concentration in powders using two-speed photon migration theory and measurements.

Two-speed photon migration in densely packed powder blends wherein the particle diameters are much larger than the incident wavelength are simulated with (i) dynamic simulation of particle sedimentation for generating powder structure, (ii) the complete-random-mixture model for predicting the active pharmaceutical ingredient (API) distribution within the powder bed, and (iii) Monte Carlo for tracking the photon trajectories. The simulation results reveal that while both absorption and isotropic scattering coefficients increase with solid-volume fraction ranging from 0.12 to 0.64, the absorption-to-isotropic-scattering ratio is (i) independent of the solid-volume fraction for particle refractive index ranging from 1.2 to 1.8 and (ii) linearly dependent upon the API volume concentration ranging from 0% to 5%. Frequency domain photon migration measurements of resin powder beds of varying particle size verified the developed simulation method. Measurements of lactose powder beds of varying particle size, solid-volume fraction, and ferric oxide particles content verified the simulation results that evidence independence of the absorption-to-isotropic-scattering ratio upon solid-volume fraction.

Absorption↗

Fully adaptive FEM based fluorescence optical tomography from time-dependent measurements with area illumination and detection.

Using an area-illumination and area-detection scheme, we acquire fluorescence frequency domain measurements from a tissue phantom with an embedded fluorescent target and obtain tomographic reconstructions of the interior fluorescence absorption map with an adaptive finite element based scheme. The tissue phantom consisted of a clear acrylic cubic box (512 ml) filled with 1% Liposyn solution, while the fluorescent targets were 5 mm diameter glass bulbs filled with 1 microM Indocyanine Green dye solution in 1% Liposyn. Frequency domain area illumination and detection employed a planar excitation source using an expanded intensity modulated (100 MHz) 785 nm diode laser light and a gain modulated image intensified charge coupled device camera, respectively. The excitation pattern was characterized by isolating the singly scattered component with cross polarizers and was input into a dual adaptive finite element-based scheme for three dimensional reconstructions of fluorescent targets embedded beneath the phantom surface. Adaptive mesh refinement techniques allowed efficient simulation of the incident excitation light and the reconstruction of fluorescent targets buried at the depths of 1 and 2 cm. The results demonstrate the first clinically relevant noncontact fluorescence tomography with adaptive finite element methods.

Algorithms↗

Three-dimensional fluorescence lifetime tomography.

Near-infrared fluorescence tomography using molecularly targeted lifetime-sensitive, fluorescent contrast agents have applications for early-stage cancer diagnostics. Yet, although the measurement of fluorescent lifetime imaging microscopy (FLIM) is extensively used in microscopy and spectroscopy applications, demonstration of fluorescence lifetime tomography for medical imaging is limited to two-dimensional studies. Herein, the feasibility of three-dimensional fluorescence-lifetime tomography on clinically relevant phantom volumes is established, using (i) a gainmodulated intensified charge coupled device (CCD) and modulated laser diode imaging system, (ii) two fluorescent contrast agents, e.g., Indocyanine green and 3-3'-Diethylthiatricarbocyanine iodide differing in their fluorescence lifetime by 0.62 ns, and (iii) a two stage approximate extended Kalman filter reconstruction algorithm. Fluorescence measurements of phase and amplitude were acquired on the phantom surface under different target to background fluorescence absorption (70:1, 100:1) and fluorescence lifetime (1:1, 2.1:1) contrasts at target depths of 1.4-2 cm. The Bayesian tomography algorithm was employed to obtain three-dimensional images of lifetime and absorption owing to the fluorophores.

Algorithms↗

Detection of single and multiple targets in tissue phantoms with fluorescence-enhanced optical imaging: feasibility study.

PURPOSE: To evaluate the feasibility of reconstructing single and multiple targets by using fluorescence-enhanced tomography of a breast tissue phantom. MATERIALS AND METHODS: Frequency-domain fluorescence measurements were performed in cup-shaped tissue phantoms of clinically relevant size (diameter, 10 cm) in which single or multiple 0.5-1.0-cm(3) targets that contained micromolar concentrations of indocyanine green with 1:0 and 100:1 target-to-background (T:B) contrast ratios had been embedded. Rapid acquisition of time-dependent fluorescent light measurements was performed at the phantom surface in response to point illumination of excitation light by using a gain-modulated intensified charge-coupled device detection system. Boundary surface measurements were used to tomographically reconstruct the interior targets located with various experimental conditions. RESULTS: Single 1.0-cm(3) targets located between 1.43 and 2.82 cm deep from the phantom surface at a T:B contrast ratio of 100:1 and three approximately 0.55-cm(3) targets located about 1.30 cm deep at a T:B contrast ratio of 1:0 were reconstructed with minimal or no artifacts by using boundary surface fluorescence measurements and an approximate extended Kalman filter algorithm. CONCLUSION: It is feasible to detect single or multiple fluorescent targets in tissue phantoms of clinically relevant size by using fluorescence-enhanced optical tomography.

Algorithms↗

Investigation of structure factors in dense colloidal suspensions using frequency domain photon migration: polydisperse systems.

Frequency domain photon migration (FDPM) technique was employed to investigate the structure factors of dense, polydisperse colloidal suspensions. The angle-integrated structure factors, [S(q)], extracted from FDPM measurements of scattering properties at volume fractions ranging from 0.05 to 0.4, were compared with the values predicted from the polydisperse hard sphere Percus-Yevick (HSPY) model, as well as decoupling approximation (DA) and local monodisperse approximation (LMA) models that incorporated independently measured particle size information. Results show that the polydisperse HSPY model is the most suitable for accounting for particle interactions which predominantly arise from volume exclusion effects. Furthermore, the influence of size polydispersity upon [S(q)] is most significant at high volume fractions. The static structure factors at small wave vector q, S(0), were also assessed from dual wavelength FDPM measurements by using the small wave number approximation as well as the local monodisperse approximation. The measured S(0) agrees well with the values predicted by the polydisperse HSPY model.

Journal Article↗

Validating the assumption to the interference approximation by use of measurements of absorption efficiency and hindered scattering in dense suspensions.

Frequency domain photon migration (FDPM) measurements were employed to accurately quantify optical properties of both the suspending fluid and particles within dense polystyrene suspensions of 143- or 226-nm mean diameter at varying concentrations (5-30% by volume). The measured absorption coefficients varied linearly with particle volume fraction whereas the isotropic scattering coefficients varied nonlinearly in agreement with the prediction that utilizes the hard-sphere structure factor model. These results validate the interference approximation of light scattering to describe light propagation accurately within dense suspensions. Furthermore, owing to the accuracy of FDPM absorption measurements, the imaginary refractive indices for both particles and their suspending fluid were determined and were found to compare favorably with literature values.

Light↗

Measurement of low-dose active pharmaceutical ingredient in a pharmaceutical blend using frequency-domain photon migration.

Frequency-domain photon migration (FDPM) measurements of time-dependent light propagation are conducted to provide the powder absorbance for quantitative prediction of terazosin as the active pharmaceutical ingredient (API) in a low-dose (0.72 wt %) oral tablet formulation. Calibration of the FDPM-derived powder absorbance at discrete wavelengths of 514, 650, 687, and 785 nm was performed for API contents ranging between 0 and 1.5 wt % in mixtures showing maximum sensitivity at 650 nm. The relative standard deviation (RSD) of FDPM absorption coefficient measurement at 650 nm in a well-mixed 1.08 wt % terazosin blend was <1.6%, of which no more than 0.12% arose from FDPM instrumental error and the remainder was attributable to the complete-random-mixture model. The applicability of FDPM as an on-line sensor for powder-blending operations was further evaluated by analyzing grab samples taken directly from five locations of a 2-cu-ft Gallay blender at intervals of 5 min within the blending process. FDPM results indicate that homogeneity was largely achieved in the first 10 min, during which the RSD of API content across five sampling locations decreased from 27% to 8%, and the RSD decreased to 5% after 25 min of blending. Evolution of homogeneity within the blending process assessed through FDPM measurements was fit to the first-order model of particle blending further evidencing applicability for monitoring powder-blending processes.

Calibration↗

Near-infrared optical imaging of integrin alphavbeta3 in human tumor xenografts.

In vivo optical imaging is potentially useful for evaluating the presence of tumor markers that are targets of molecular medicine. Here we report the synthesis and characterization of integrin alphavbeta3-targeted peptide cyclo(Lys-Arg-Gly-Asp-Phe) [c(KRGDf )] labeled with fluorescence dyes with wavelength spanning from the visible/near infrared (Cy5.5) to the true near infrared (IRDye800) for optical imaging. In vitro, the peptide-dye conjugates bound specifically to tumor cells expressing alphavbeta3. When administered intravenously into mice at a dose of 6 nmol /mouse, the conjugates accumulated in tumors expressing alphavbeta3. The tumor-to-background ratios for human KS1767 Kaposi's sarcoma in mice injected with Cy5.5-c(KRGDf ) and Cy5.5 were 5.5 and 1.5, respectively. Preinjection of c(KRGDf ) blocked the uptake of Cy5.5-c(KRGDf ) in tumors by 89%. In alphavbeta3-positive M21 and alphavbeta3-negative M21-L human melanoma, fluorescence intensity in the tumor of mice injected with IRDye800 - c(KRGDf ) was 2.3 and 1.3 times that in normal tissue, respectively. Dynamic imaging revealed that Cy5.5- c(KRGDf ) was rapidly taken up by KS1767 tumor immediately after bolus injection. The rate of its uptake in the tumor was reduced by preinjection of c(KRGDf ) in an interval time-dependent manner. Our data suggest that near-infrared fluorescence imaging may be applied to the detection of tumors expressing integrin alphavbeta3 and to the assessment of the optimal biological dose and schedule of targeted therapies.

Animals↗

Characterization of pigment particle absorption efficiencies using frequency domain photon migration.

Time-dependent measurements of multiply scattered light were made using frequency domain photon migration (FDPM) techniques in polystyrene latex as a function of ppm pigment concentration (by weight) in order to determine the wavelength-dependent absorption efficiencies for three different pigment particles. The results demonstrate that the absorption spectra of pigment particles within their dispersing vehicles concur with the complementary color chart. FDPM offers a first-principles method for assessing optical characteristics of pigments within their dispersing vehicles and without the need to resort to conventional measurement of diffuse reflectance from coatings and data analysis using phenomenological theory.

Journal Article↗

Near-infrared optical imaging of epidermal growth factor receptor in breast cancer xenografts.

The specificity of a novel epidermal growth factor (EGF)-Cy5.5 fluorescent optical probe in the detection of EGF receptor (EGFr) was assessed using continuous-wave fluorescence imaging accomplished via an intensified charge-coupled device (CCD) camera. Human mammary MDA-MB-468 (EGFr+) and MDA-MB-435 (EGFr-) cancer cells were incubated with Cy5.5, EGF-Cy5.5, or the anti-EGFr monoclonal antibody C225 or EGF followed by EGF-Cy5.5 and examined under a fluorescence microscope. In vivo imaging was performed on mice with s.c. MDA-MB-468 and MDA-MB-435 tumors. Images were obtained every 6 s for 20 min after i.v. injection of each agent and every 24 h after injection for up to 192 h. Additionally, mice with MDA-MB-468 tumors were injected i.v. with C225 24 h before injection of EGF-Cy5.5. EGF-Cy5.5, but not Cy5.5 or indocyanine green dye (ICG), bound to MDA-MB-468 cells. Binding of EGF-Cy5.5 was blocked by C225 and by EGF. In contrast, binding of EGF-Cy5.5 to MDA-MB-435 cells was not observed. Monitoring of the time-fluorescence intensity in mice confirmed that ICG and Cy5.5 had no favorable binding to tumor regardless of EGFr expression level. In contrast, EGF-Cy5.5 accumulated only in MDA-MB-468 tumors. Moreover, tumor uptake of EGF-Cy5.5 was blocked by C225. ICG and Cy5.5 fluorescence was completely absent from the tumor site, regardless of EGFr expression level, 24 h after injection. Little EGF-Cy5.5 fluorescence was detected in MDA-MB-435 tumors 24 h after injection. In MDA-MB-468 tumors, our data suggest that EGF-Cy5.5 may be used as a specific NIR contrast agent for noninvasive imaging of EGFr expression and monitoring of responses to molecularly targeted therapy.

Adenocarcinoma↗

Fluorescence lifetime spectroscopy for pH sensing in scattering media.

Fluorescence lifetime spectroscopy in the presence of tissuelike scattering is demonstrated from measurements of phase and modulation ratio as a function of modulation frequency using a pH-sensitive dye, Carboxy Seminaphthofluorescein-1 (C-SNAFL-1). From the optical diffusion equation describing the propagation and generation of fluorescence within solutions of 0.5 microM C-SNAFL-1 containing 2.0% (by volume) of Intralipid as a scatterer, the values of the average lifetime of C-SNAFL-1 were determined as the solution pH varied between 5 and 9. Average lifetime values were found to match those measured using traditional phase-modulation measurement in nonscattering media. Furthermore, the robustness of the spectroscopic technique was demonstrated by conducting lifetime measurements at varying scatterer concentrations (1.5-3.0 vol % Intralipid). These results confirm the approach for analytical sensing in scattering media via fluorescence lifetime kinetics in order to track changes in analyte concentrations.

Journal Article↗

Near-infrared fluorescence contrast-enhanced imaging with area illumination and area detection: the forward imaging problem.

Fluorescence frequency-domain photon migration measurements were acquired from tissue phantoms, each containing a fluorescent target, by means of area illumination and area detection on the same surface and for the first time, to our knowledge, compared with predictions computed with a numerical solution to the coupled photon diffusion equations. We accomplished area illumination and area detection using a planar, intensity-modulated excitation light source and a gain-modulated intensified charge-coupled device camera, respectively. A 1-ml vessel containing 1-microm solution of Indocyanine Green in 1% Liposyn was immersed 1 cm deep in each 512-ml tissue phantom. For most tissue phantoms, the background surrounding the 1-ml target was composed of Liposyn solution containing Indocyanine Green or 3,3'-Diethylthiatricarbocyanine Iodide such that the target-to-background ratio of fluorescence yield was > or = 10:1. Measurements of fluorescence modulation amplitude and phase were predicted with a mean error ranging from 10.1% to 13.6% and 0.56 degrees to 1.72 degrees, respectively. These numbers are similar to those obtained by use of single-pixel frequency-domain photon migration techniques and validate the potential use of area illumination and area detection for biomedical imaging of tissues. Results also demonstrate that target-to-background ratios of fluorescence yield and fluorescence lifetime significantly affect target detectability.

Contrast Media↗

Fluorescence-enhanced optical imaging in large tissue volumes using a gain-modulated ICCD camera.

A novel image-intensified charge-coupled device (ICCD) imaging system has been developed to perform 3D fluorescence tomographic imaging in the frequency-domain using near-infrared contrast agents. The imager is unique since it (i) employs a large tissue-mimicking phantom, which is shaped and sized to resemble a female breast and part of the extended chest-wall region, and (ii) enables rapid data acquisition in the frequency-domain by using a gain-modulated ICCD camera. Diffusion model predictions are compared to experimental measurements using two different referencing schemes under two different experimental conditions of perfect and imperfect uptake of fluorescent agent into a target. From these experimental measurements, three-dimensional images of fluorescent absorption were reconstructed using a computationally efficient variant of the approximate extended Kalman filter algorithm. The current work represents the first time that 3D fluorescence-enhanced optical tomographic reconstructions have been achieved from experimental measurements of the time-dependent light propagation on a clinically relevant breast-shaped tissue phantom using a gain-modulated ICCD camera.

Biophysical Phenomena↗

Application of frequency domain photon migration to particle size analysis and monitoring of pharmaceutical powders.

The frequency domain photon migration (FDPM) technique was employed to determine mean particle size of pharmaceutical powders. Results show that the FDPM-measured scattering coefficient increases linearly with reciprocal mean particle size of powdered samples. In contrast to near-infrared spectroscopy techniques, FDPM technique enables determination of scattering and absorption separately so that it does not require data pretreatment and chemometric calibration models. In addition, this unique advantage provides more detailed information about powder samples, which can be used as a potential tool for on-line monitoring of not only variation of active pharmaceutical ingredient concentrations from changes in the absorption coefficient but also variation of particle sizes from changes in the scattering coefficient.

Chemistry, Pharmaceutical↗

Fluorescence-enhanced optical tomography using referenced measurements of heterogeneous media.

A three-dimensional image reconstruction for fluorescence-enhanced frequency-domain photon migration (FDPM) measurements in turbid media is developed and investigated for three different simulated measurement types: 1) absolute emission measurement, or emission measurements of phase and amplitude attenuation made for a given incident point source of excitation light; 2) referenced emission measurements made relative to an excitation measurement conducted at a single reference point away from the incident source; and 3) referenced emission measurements made relative to the excitation measurement conducted at identical points of detection. The image reconstruction algorithm employs a gradient-based constrained truncated Newton (CONTN) method which implements a bounding parameter, which can be used to govern the level of contrast used to discriminate tissue volumes from heterogeneous background tissues. Reverse differentiation technique is used to calculate the gradients. Using simulated data with superimposed noise to achieve a signal-to-noise ratio of 55 and 35 dB to mimic experimental excitation and emission FDPM measurements, respectively, we show the robustness of emission measurements referenced to excitation light. We investigate the performance of algorithm CONTN using these measurement techniques and show that the absorption coefficients due to fluorophore are reconstructed by CONTN accurately and efficiently. Furthermore, we demonstrate the performance of the bounding parameter for rejection of background artifacts owing to background tissue heterogeneity.

Algorithms↗

Near-infrared fluorescence contrast-enhanced imaging with intensified charge-coupled device homodyne detection: measurement precision and accuracy.

Fluorescence frequency-domain photon migration (FDPM) through tissue refers to the propagation of intensity-modulated fluorescent light that originates from tissue-laden fluorophores following illumination with an intensity-modulated excitation light source. FDPM measurements of modulation amplitude and phase are ultimately employed in an inversion algorithm for tomographic reconstruction of interior optical and fluorescent property maps that delineate disease enhanced with fluorescent contrast agent. Because the inverse problem is underdetermined, measurement precision and accuracy crucially impact its solution. Reported here are the precision and accuracy of FDPM measurements acquired using an intensified CCD homodyne detection system. By introducing 32 phase delays between the oscillators used to modulate the intensifier gain and light source intensity at 100 MHz, mean precision is maximized at +/-0.46% and +/-0.26 deg for measurements of modulation amplitude and phase, respectively. Measurement precision improves when the number of phase delays increases. Measurements of fluorescence modulation amplitude and phase, acquired from the surface of a tissue phantom at distances ranging between 0.71 and 3.6 cm from an incident excitation point source, exhibit a mean accuracy of 17% and 1.9 deg, respectively. Measurement accuracy deteriorates with increasing distance from the point source, but for distances up to 1.0 cm from the point source, measurements of fluorescence modulation amplitude and phase exhibit a mean accuracy of 5.4% and 0.30 deg, respectively.

Breast Neoplasms↗

Sensitivity and depth penetration of continuous wave versus frequency-domain photon migration near-infrared fluorescence contrast-enhanced imaging.

The development of near-infrared fluorescent contrast agents and imaging techniques depends on the deep penetration of excitation light through several centimeters of tissue and the sensitive collection of the re-emitted fluorescence. In this contribution, the sensitivity and depth penetration of various fluorescence-enhanced imaging studies is surveyed and compared with current studies using continuous wave (CW) and frequency-domain photon migration (FDPM) measurements with planar wave illumination of modulated excitation light at 100 MHz and area collection of reemitted fluorescent light using a previously developed modulated intensified charge-coupled device camera system. Fluorescence was generated from nanomolar to micromolar solutions of indocyanine green (ICG) in a 100 microL volume submerged at 1-4 cm depths in a 1% Liposyn solution to mimic tissue scattering properties. Enhanced depth penetration and sensitivity are achieved with optimal filter rejection of excitation light, and FDPM rejection of background light is not achieved using CW methods. We show the ability to detect as few as 100 fmol of ICG from area illumination of 785 nm light (5.5 mW/cm2) and FDPM area collection of 830 nm fluorescent light generated from 3 cm below the phantom surface. The lowered noise floor of FDPM measurements enables greater sensitivity and penetration depth than comparable CW measurements.

Photons↗