Patients supported for over 4 years with left ventricular assist devices.

Ventricular assist device implantation has become an established therapy in adults and children for bridging to heart transplantation or to aid myocardial recovery. Recently, implantation of left ventricular assist devices as definitive therapy has been recognized as a better option than pharmacological treatment in patients who are not candidates for heart transplantation. This study presents our institution's experience with five patients successfully supported by two different left ventricular assist devices for over 4 years. This unique experience shows that left ventricular assist device support can be extended beyond 4 years with good quality of life and low risk, making it a good alternative for non-transplant candidates.

Adult↗

Improvement in survival after mechanical circulatory support with pneumatic pulsatile ventricular assist devices in pediatric patients.

BACKGROUND: Pediatric size pneumatically driven extracorporeal ventricular assist devices (VAD) for infants and small children were introduced into clinical routine in 1992. In the initial period, the results in infants were poor. Since then, several improvements have been introduced with regard to the cannulas, connectors, heparin coating of the blood pump inner surface, anticoagulant treatment and coagulation monitoring, and earlier decision-making in favor of pump implantation before irreversible shock has set in. METHODS: Since 1990 and as of January 1, 2005, 62 Berlin Heart Excor systems have been implanted in patients below 18 years of age at our institution. The patients were divided into two groups according to the period of treatment: period 1, devices implanted between 1990 and 1998 (n = 34), and period 2, devices implanted between 1999 and 2004 (n = 28). We compared our experience during the earlier and later periods. RESULTS: There were no significant differences in the preoperative patient data between the two periods except for time of support (17.9 +/- 27.7 days versus 53.2 +/- 83.9 days, p = 0.001). In period 1, more patients needed a biventricular VAD whereas in period 2, more patients were effectively treated with a left VAD (p = 0.05). In the later period, the chest could be primarily closed in a significantly higher percentage of infants (0% versus 89%, p = 0.012), and more infants could be extubated on the VAD (0% versus 55%, p = 0.16). Discharge from the hospital after either weaning from the system or heart transplantation was achieved for 35% in period 1 and for 68% in period 2 (p = 0.029). Whereas in period 1 there were no survivors in the group of children younger than 1 year old, during period 2, survival in this age group was similar to that of the two groups of older children (p = 0.024). There was a significant improvement in the discharge rate in period 2 in patients with cardiomyopathy (43% versus 76%, p = 0.045) and postcardiotomy heart failure (0% versus 57%, p = 0.01). CONCLUSIONS: Earlier implantation of VADs, heparin coating of the blood pumps, and substantial modifications in cannula design, anticoagulation, and the coagulation monitoring regimen have led to a significant increase in the survival and discharge rate, especially among children under 1 year of age. The pediatric size Berlin Heart Excor VAD is a valuable option as a bridge to heart transplantation or recovery for children suffering from cardiogenic shock.

Adolescent↗

Natriuretic peptides and E-selectin as predictors of acute deterioration in patients with inotrope-dependent heart failure.

OBJECTIVE: In patients with inotrope-dependent end-stage heart failure the timely application of the most suitable treatment, i.e. heart transplantation, implantation of a ventricular assist device or conservative treatment, is a key issue for therapeutic success. METHODS: Seventy-six inotrope-dependent patients with end-stage heart failure were enrolled. Measurements of hemodynamics, routine laboratory parameters, and clinical examination were performed daily. Additionally, natriuretic peptides (BNP and NT-proBNP) and E-selectin were measured at the end of the study. The patients were retrospectively divided into groups with regard to the following end-points: Group I-deterioration into cardiogenic shock after an initially stable clinical course (n=26); Group II-stable clinical course without deterioration into cardiogenic (n=41); Group III-weaning from inotropic support (n=9). RESULTS: One day before cardiogenic shock occurred, BNP, NT-proBNP and E-selectin were significantly elevated in group I compared with group II. A logistic regression model showed that only BNP and E-selectin were independent predictors of clinical deterioration on the following day. The odds ratio (OR) for E-selectin using a cut-off point of 65ng/ml was 8.7 and for BNP using a cut-off of 500pg/ml it was 4.8. In combination, the OR increased to 11.1. Continuous decrease of NT-proBNP predicted patients in whom weaning from inotropes was possible. CONCLUSIONS: While routine parameters did not predict the clinical course, elevated BNP and E-selectin independently predicted cardiogenic shock on admission and 1 day before its occurrence. The combination showed increased predictive value.

Adolescent↗

Clinical significance of PlA polymorphism of platelet GP IIb/IIIa receptors during long-term VAD support.

BACKGROUND: Although bleeding and thromboembolism remain major complications after implantation of ventricular assist devices (VADs), no standard anticoagulation protocols are available. Genetic polymorphism of platelet glycoprotein IIb/IIIa may contribute to the development of complications. The present study demonstrates a relationship between the PlA genotype and postoperative complications in patients implanted with pulsatile and axial flow VADs. METHODS: The PlA genotype was determined in 41 consecutive patients treated with a VAD who received anticoagulation with phenprocoumon and aspirin. Pulsatile Novacor (Novacor Corp, Oakland, CA) and Berlin Heart VADs (Berlin Heart, Berlin, Germany) were implanted in 28 patients and the axial flow MicroMed DeBakey VAD (MicroMed Technology, Inc, Houston, TX) in 13. The relationship between the PlA genotype, the anticoagulation regime, and bleeding and thromboembolic events was analyzed. RESULTS: There were no differences between patients with the A1A1 and A1A2 genotype regarding demographic characteristics, weight, or infection episodes. The international normalized ratio (INR), platelet activation tests, and doses of aspirin and dipyridamol before events were similar in both groups. Patients with the A1A1 genotype developed more bleeding complications (39% vs 0%, p = 0.021), while patients with the A1A2 genotype showed a tendency toward more thromboembolic events (13% vs 30%, p = 0.33). With regard to different types of VAD, patients with the axial flow DeBakey VAD and the A1A1 genotype developed significantly more bleeding complications (70% vs 0%, p = 0.033). CONCLUSIONS: In patients with a long-term VAD determination of PlA polymorphism and subsequent adjustment of the anticoagulation regime may lead to a reduction of bleeding and thromboembolic complications.

Anticoagulants↗

First experiences with a novel magnetically suspended axial flow left ventricular assist device.

UNLABELLED: Axial flow pumps have gained increased acceptance since their first clinical use in 1998. The present report summarizes the clinical experience with patients treated for severe cardiogenic shock for the first time with a newly developed axial flow pump with magnetically levitated bearings. MATERIAL AND METHODS: The axial flow pump Incor was implanted in 24 patients between June 2002 and June 2003. All except one patient were men. In 16 patients dilative cardiomyopathy, in seven ischemic and in one restrictive cardiomypathy had been diagnosed. All patients presented with catecholamine-dependent end-stage heart failure, seven of them were on an artificial ventilator and three were dependent on intraaortic balloon pump support. All patients suffered from organ dysfunction resulting from low cardiac output. RESULTS: There were no perioperative deaths. The 30-day mortality rate was 8% (n = 2); 79% ( n = 19) of patients reached a condition to be discharged home. The cumulative time on the device is 6.9 years; the longest individual time up to July 1, 2003 is 12.6 months. There were no structural defects or failures of the system. In one case the controller had to be exchanged because of intermittent malfunction. Cardiac output ranged between 4 and 6 l in all instances and there were no cases of infection of the drive-line or the system. Hemolysis was present initially but was not detectable in the later course. There were three instances of transient ischemic attacks. Two patients developed late cardiac tamponade with re-opening of the chest after 9 and 14 days. In one patient persistent gastrointestinal bleeding required re-hospitalization and transfusion therapy. Two patients were weaned from the device after 6 and 7 months of support, respectively. CONCLUSION: The preliminary clinical experience with Incor is promising. The flow is sufficient for recovery from multiorgan failure and the pump allows long-term hemolysis-free support. The concept of magnetically levitated bearings has proven to be durable and reliable. In the case that the heart may recover through unloading, weaning from the pump is possible.

Adult↗

Transcontinental transport of a patient with an AbioMed BVS 5000 BVAD.

In patients with severe cardiogenic shock requiring implantation of a short-term assist device transportation to a specialized heart center for further therapy may be necessary. We report the first successful transcontinental air transport (from Singapore to Berlin, Germany) of a patient with fulminating myocarditis requiring implantation of a biventricular assist device.

Air Ambulances↗

Impact of body mass index on outcome in patients after coronary artery bypass grafting with and without valve surgery.

BACKGROUND: Among other preoperative parameters, extremely low or extremely high body mass index (BMI) has been discussed as a substantial risk factor for postoperative complications after cardiac surgery. However, the exact relationship between BMI and postoperative risk has not yet been defined. METHODS: We retrospectively investigated consecutive patients (n=22666) who underwent coronary artery bypass grafting with or without concomitant valve surgery between 1990 and 2001 in our institution. A number of preoperative and intraoperative variables and BMI (as a quadratic term) were used in a logistic regression model as covariates. Further, the patients were divided into 20 groups each with an increase in BMI of 1kg/m(2)(BMI as a categorical variable). The calculations of odds ratios (ORs) for re-intubation, infection, re-exploration, prolonged stay (>1 day) on the intensive care unit (ICU) and 30-day mortality were adjusted for age, gender and type of surgery. RESULTS: In the multivariate analysis only age (OR between 1.01 and 1.038, P<0.01), additional aortic valve (OR between 1.335 and 2.977, P<0.01) or mitral valve surgery (OR between 2.123 and 3.301, P<0.01) showed significant impact on all five end-points. Patients with BMI between 25 and 35kg/m(2)were not at elevated risk for any of the investigated end-points, except for infection. Patients with BMI between 21 and 27kg/m(2)were not at elevated risk for infection. The ORs for postoperative complications were significantly higher in underweight patients compared with obese or severely obese patients, except those for infection. Further, the underweight patients presented significantly more comorbidity. CONCLUSION: Patients with low BMI are at higher risk after cardiac surgery than obese or severely obese patients. We hypothesize that a preoperative focus on avoiding and/or reversing cachexia may be more efficacious than reducing obesity in reducing the overall risk associated with heart surgery.

Body Mass Index↗

New approach in treatment of acute cardiogenic shock requiring mechanical circulatory support.

In 12 patients with acute cardiogenic shock who required mechanical circulatory support a short-term Abiomed BVS 5000 extracorporeal assist device was implanted using the inflow and outflow cannulas of the BerlinHeart extracorporeal assist device. In 7 patients suitable for long-term support the Abiomed pumps were later exchanged for BerlinHeart pumps. This approach avoids the risks associated with repeat sternotomy and use of cardiopulmonary bypass and decreases the total costs of patient care.

Acute Disease↗

Elevated donor cardiac troponin T and procalcitonin indicate two independent mechanisms of early graft failure after heart transplantation.

BACKGROUND: Cardiac troponin T (cTnT) >0.1 microg/l and procalcitonin (PCT) >2 microg/l in the serum of heart donors are predictors of early graft failure after heart transplantation (HTx). The current study investigates the relationship between these two markers and their prognostic value when one or both of them are elevated. METHODS: Cardiac TnT and PCT were measured in serum from 92 consecutive brain-dead donors accepted for HTx. The donors were retrospectively divided into two groups: group I (n=78) donors of hearts with good function, group II (n=14) donors of hearts with early graft failure after transplantation. RESULTS: There were no correlations between cTnT and PCT values (r=0.12, P=0.27). In eight donors in group I one or both markers were elevated. In one donor both markers were above the cut-off levels. In 12 donors (86%) in group II one or both markers were elevated. In two donors both markers were above the cut-off levels and in a further two below. There was no significant interaction between the two markers in either group using a logistic regression model (P=0.28). CONCLUSIONS: Elevated cTnT and PCT levels in the serum of heart donors were independent prognostic markers of early graft failure. This fact may suggest two different mechanisms of early graft failure: primary myocardial damage and damage related to systemic inflammatory response. The combination of both markers had a higher sensitivity than each parameter on its own. Their use as additional parameters may improve heart donor selection.

Adult↗

The MicroMed DeBakey VAD--part I: The pump and the blood flow.

The results obtained in over 100 patients implanted with the MicroMed DeBakey VAD in several centers in Europe and USA (September 2001, M. Loebe, personal communication) demonstrate that the effectiveness of the MicroMed DeBakey VAD is comparable to that of the pulsatile devices and that it also shows some superior properties. Recently, other axial pumps--the Jarvic 2000 (72) and HeartMate II (73)--have come into clinical use. Because the patients show good tolerance of the nonpulsatile blood flow in the early postoperative period, and pulsatility increased with recovery of the left ventricle because of unloading, we believe that the axial pumps will gain wide acceptance and provide a new option in the treatment of heart failure.

Heart-Assist Devices↗

Prognosis after the implantation of an intra-aortic balloon pump in cardiac surgery calculated with a new score.

BACKGROUND: Over the past decade, the use of a ventricular-assist device (VAD) in patients with postcardiotomy cardiogenic shock has resulted in hospital discharge rates of 25% to 40% and is improving. Nevertheless, indications for and timing of the implantation of a VAD in patients who have received an intra-aortic balloon pump (IABP) remain unclear. METHODS AND RESULTS: From July 1996 to March 2000, 391 patients with cardiac low-output syndrome who underwent open-heart surgery and had an IABP implanted were analyzed in a retrospective pilot study. The perioperative mortality was 34% (133 patients). Clinical parameters were analyzed 1 hour after IABP support began. Statistical multivariate analysis showed that patients with an adrenaline requirement higher than 0.5 microg x kg(-1) x min(-1), a left atrial pressure >15 mm Hg, urine output <100 mL/h, and mixed venous saturation (SVO(2)) <60% had poor outcomes. Using this data, we developed an IABP score (0 to 5 points) to predict survival early after IABP implantation in cardiac surgery. We evaluated our score by monitoring another 101 patients as a control group prospectively. Additionally, 210 patients who received coronary artery bypass grafting (CABG) exclusively were analyzed. All investigations confirmed the validity of the score. CONCLUSIONS: The IABP score can predict survival early after IABP implantation. In patients with a high IABP score, implantation of a VAD should be considered.

Aged↗

[Heart assist systems--current status].

BACKGROUND: Heart failure is the leading cause of death in the developed countries. Organ-preserving operative procedures on the failing heart like coronary artery bypass procedures or resection of left ventricular aneurysms are part of the routine care in cardiac surgery today. Terminal heart failure refractory to optimized drug therapy, however, will require a heart transplantation or the implantation of artificial blood pumps. While heart transplantation has proven to provide excellent long-term results with 10-year survival rates at 50%, it will remain a casuistic therapy, limited by the comparatively small number of procedures which can be performed. ARTIFICIAL BLOOD PUMPS: The current status of development of artificial blood pumps is represented by the broad availability of partially-implantable electric motor-driven left ventricular assist devices (LVAD), which still require a percutaneous cable for energy supply and device control from external sources while the blood pump itself resides inside the body. The recently introduced axial-flow devices (DeBakey, Jarvik 2000 and HeartMate II LVADs) deliver a continuous blood flow and obviously provide distinct advantages with regard to a reduction in size, weight and energy demands, simplified implantation technique and device control when compared to the previously available partially-implantable electric motor-driven pulsatile blood pumps (Novacor N100, TCl Heart Mate LVADs). The first systems designed for long-term or permanent use (Lion Heart LVAD, AbioCor replacement heart) are completely implantable devices featuring percutaneous energy transmission and device control. However, the latter are more complex devices and their clinical application is still limited to a small number of cases, which precludes a judgment about their potential at this time. INDICATIONS: The use of paracorporeal pneumatically accentuated blood pump systems is still indicated in cases of most severe biventricular heart failure and multiorgan failure or if only short- to mid-term circulatory support is anticipated. Well established indications for utilization of artificial blood pumps are the bridge-to-transplant procedure, which yields results comparable to primary heart transplantation, and acute cardiac failure following myocardial infarction or cardiac surgical procedures. In newborns and children, encouraging results were obtained when miniaturized blood pumps of the Berlin Heart System were utilized for heart failure in myocarditis or dilative cardiomyopathy. With advanced reliability of artificial blood pumps and in face of the high incidence of heart failure, especially in the older age group, the long-term application of artificial bloods pump appears to be justified.

Equipment Design↗

Impact of cardiac surgery using cardiopulmonary bypass on course of chronic lymphatic leukemia: a case-control study.

BACKGROUND: Chronic lymphatic leukemia (CLL) is a common disease among elderly individuals. The number of older patients undergoing operations with cardiopulmonary bypass (CPB) is increasing. The aim of the present study was to evaluate the impact of cardiac surgery using CPB on the long-term course of CLL. METHODS: From 1992 to 2000, a total of 28 patients with CLL underwent heart surgery using CPB at our institution (group I). These patients were compared with 25 patients from the CLL register who were retrospectively matched with regard to preoperative administration of chemotherapy, Binet classification, age, and sex (group II). A time-point was selected for each patient in group II so that the variables for the two groups corresponded in relation to the time of operation of the patients in group I. Midterm follow-up data in both groups were analyzed. RESULTS: There were no differences between groups regarding matched variables. The mean follow-up time was similar in both groups (2.6 +/- 2.2 vs 2.3 +/- 1.3 years, p > 0.5). The 30-day mortality in group I was 14.3%. The mean stay in the intensive care unit was 4.2 +/- 7.5 days; the median number of units of packed red blood cells transfused was three (range 0 to 17). Compared with group II, in group I significantly fewer patients (11 vs 17, p = 0.049) required chemotherapy significantly later (1.98 +/- 2.06 vs 0.84 +/- 1.18 years, p = 0.018). During follow-up, no difference was found between groups regarding severe infections (10 vs 14, p = 0.14). Despite postoperative mortality in group I, the long-term mortality was similar in both groups (p = 0.3). CONCLUSIONS: Cardiac surgery using CPB did not have a negative impact on the natural course of CLL. Moreover, this procedure seems to be associated with a decrease in the number of postoperative chemotherapy administrations and with an increase of chemotherapy-free survival time. Although CLL may be a risk factor in the early postoperative period, it is not a contraindication for cardiac surgery using CPB.

Cardiopulmonary Bypass↗