[Heart assist systems--current status].

Abstract

BACKGROUND: Heart failure is the leading cause of death in the developed countries. Organ-preserving operative procedures on the failing heart like coronary artery bypass procedures or resection of left ventricular aneurysms are part of the routine care in cardiac surgery today. Terminal heart failure refractory to optimized drug therapy, however, will require a heart transplantation or the implantation of artificial blood pumps. While heart transplantation has proven to provide excellent long-term results with 10-year survival rates at 50%, it will remain a casuistic therapy, limited by the comparatively small number of procedures which can be performed. ARTIFICIAL BLOOD PUMPS: The current status of development of artificial blood pumps is represented by the broad availability of partially-implantable electric motor-driven left ventricular assist devices (LVAD), which still require a percutaneous cable for energy supply and device control from external sources while the blood pump itself resides inside the body. The recently introduced axial-flow devices (DeBakey, Jarvik 2000 and HeartMate II LVADs) deliver a continuous blood flow and obviously provide distinct advantages with regard to a reduction in size, weight and energy demands, simplified implantation technique and device control when compared to the previously available partially-implantable electric motor-driven pulsatile blood pumps (Novacor N100, TCl Heart Mate LVADs). The first systems designed for long-term or permanent use (Lion Heart LVAD, AbioCor replacement heart) are completely implantable devices featuring percutaneous energy transmission and device control. However, the latter are more complex devices and their clinical application is still limited to a small number of cases, which precludes a judgment about their potential at this time. INDICATIONS: The use of paracorporeal pneumatically accentuated blood pump systems is still indicated in cases of most severe biventricular heart failure and multiorgan failure or if only short- to mid-term circulatory support is anticipated. Well established indications for utilization of artificial blood pumps are the bridge-to-transplant procedure, which yields results comparable to primary heart transplantation, and acute cardiac failure following myocardial infarction or cardiac surgical procedures. In newborns and children, encouraging results were obtained when miniaturized blood pumps of the Berlin Heart System were utilized for heart failure in myocarditis or dilative cardiomyopathy. With advanced reliability of artificial blood pumps and in face of the high incidence of heart failure, especially in the older age group, the long-term application of artificial bloods pump appears to be justified.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Roland Hetzer, Michael J Jurmann, Evgenij V Potapov, Ewald Hennig, Brigitte Stiller, Johannes H Müller, Yuguo Weng. 2002. [Heart assist systems--current status].. https://doi.org/10.1007/s00059-002-2400-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dual-trap technique for reduction of low-frequency noise in force measuring optical tweezers.

High-resolution long-time force measurements by optical tweezers are often limited by low-frequency (1/f) noise. A dual-trap technique is presented that can reduce such noise in the force signal. It incorporates a second trap (a reference trap) that probes the noise in the system and it is based upon the assumption that the low-frequency parts of the noise from the two traps are correlated. A subtraction of the low-frequency signal from the reference trap from the signal from the force measuring trap will therefore yield a net signal that is significantly less influenced by noise. It is shown that this dual-trap technique can reduce the noise in the force signal up to 60% depending on detection bandwidth.

Equipment Design↗

Optimization of doses received by the hospital staff and the members of the family of patients undergoing 111In-DTPA-D-Phe1-Octreotide therapy.

According to the Euratom Directives (96/29, 97/43), the doses received by the workers as well as the family of patients and third persons during medical exposures, should conform to the dose constraint levels (DCLs), established by the authorities for each group in the context of optimisation. This study deals with the implementation of a radiation protection protocol, concerning the aforementioned group members for patients undergoing treatment with 111In-DTPA-D-Phe1-Octreotide, after intra-arterial infusion. It is shown that by applying this protocol the annual doses to the medical and technical staff are considerably reduced and remain below the established DCLs. Following the post-release behaviour instructions given to the patient, doses to the family and third persons may be kept lower than the corresponding DCLs provided by the National Regulations.

Equipment Design↗

In vivo myograph measurement of muscle contraction at optimal length.

BACKGROUND: Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Consequently, for clinical testing only semi-quantitative methods have been used. METHODS: We present a newly developed myograph, an accurate measuring device for muscle contraction, consisting of three elements. Firstly, an element for adjusting the axle of the device and the physiological axis of muscle contraction; secondly, an element to accurately position and reposition the extremity of the muscle; and thirdly, an element for the progressive pre-stretching and isometric locking of the target muscle. Thus it is possible to examine individual in vivo muscles in every pre-stretched, specified position, to maintain constant muscle-length conditions, and to accurately re-establish the conditions of the measurement process at later sessions. RESULTS: In a sequence of experiments the force of contraction of the muscle at differing stretching lengths were recorded and the forces determined. The optimum muscle length for maximal force of contraction was established. In a following sequence of experiments with smaller graduations around this optimal stretching length an increasingly accurate optimum muscle length for maximal force of contraction was determined. This optimum length was also accurately re-established at later sessions. CONCLUSION: We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations.

Equipment Design↗