PubMed Health⌕ Search

Biomedical subjects

F Berger

Publications and source records attributed to F Berger.

At least 109 records · Page 6Linked to original sources

[Interventional occlusion of atrial septum defects larter than 20 mm in diameter].

UNLABELLED: Over the last few years, various devices for the interventional closure of atrial septal defects (ASD) up to a diameter of 20 mm have been developed. We report our clinical experience in closing ASD with a diameter larger than 20 mm diameter with the Amplatzer Septal Occluder (ASO). METHOD: The stretched diameter of the ASD was measured by inflating a sizing balloon within the defect until an indentation in the circumference in the balloon could be observed. An ASO with a stent diameter 2-4 mm larger than the indentation in the circumference of the balloon was chosen and implanted via 9-12 French sheaths. In contrast to the closure of smaller defects, pullback of the device onto the atrial septum was only performed when the connecting stent of the ASO was completely deployed in order to achieve maximal centering characteristics and optimal support of the retention skirt of the left atrial disc on the edges of the defect. Only then was the right atrial disc deployed and actively configured by advancing the sheath and the delivery cable against the atrial septum. Implantation was only attempted if the atrial septal rims (except the anterior rim around the aorta) measured more than 7 mm by echocardiography to avoid injury or disturbance of sensitive intracardiac structures. After placement, the fixation of the device and the mechanical stability was proven by an extensive "Minnesota wiggle". The ASO was released only when TEE showed no or a trivial residual color flow through the connecting stent; otherwise repositioning was performed. RESULTS: Out of 352 patients (P) with successful closure of interatrial defects, 70 P (age: 1.1-77.3 years) had stretched defects larger than 20 mm diameter (median 22 mm diameter (20-36), 25/75% quartiles = 20/26 mm). Mean shunt size was Qp:Qs 2.1:1 (0.7-3.9:1), mean fluoroscopy time 10.9 min (0-63). Complete closure could be achieved in 85.7/93.1/100% after 3 months, 1 and 2 years, respectively. Besides 3 P with persistent atrial fibrillation, only 5 P showed transient atrial tachyarrhythmias, 2 only periprocedural and 3 within the first 3 months after implantation were treated with beta-blocker. In one patient, an acute embolization of the device occurred because a diminished posterior rim was not visualized by a monoplane TEE probe necessitating surgical explantation and defect occlusion. Despite oversizing the device, no "mushrooming" misconfiguration were observed. CONCLUSION: Transcatheter closure of large atrial septal defects with the Amplatzer Septal Occluder is feasible, safe and effective. Risk of complications do not seem to occur more frequently than after closure of smaller defects if one adheres to certain sizing and implantation measures. The incidence of transient atrial tachyarrhythmias seems to be low.

Adolescent↗

[Interventional treatment of congenital heart defects in infants with a body weight up to 2,500 grams].

BACKGROUND: Pediatricians and neonatologists are still reluctant to consider invasive cardiological or cardiosurgical treatment in low body weight infants because it is believed to considerably increase the risk. The aim of this study was to assess the results and complications of percutaneous transcatheter interventions in infants with a weight below 2.5 kilograms. METHODS: Retrospective analysis was undertaken for all patients with a weight below 2.5 kilograms who underwent cardiac catheterization from 01/1994 to 04/1999. During this time 42 diagnostic catheterizations in 29 patients and 27 transcatheter interventions in 24 patients were performed. RESULTS: Surgery was replaced or effectively postponed in 9 (33%) out of 27 transcatheter interventions. This was possible for pulmonary stenosis, valvular aortic stenosis and aortic coarctation. A stabilization of the hemodynamic situation was possible in 14 patients. An antegrade pulmonary flow was established in 5, an effective interatrial shunt created in 5 and the arterial duct stented in 3 patients. Only 3 patients had no benefit from the intervention; however, there were no deaths nor hemodynamic complications. Arrhythmias occurred in 9% of all catheterizations and interventions but were transient in all cases. Femoral arterial complications were observed in 30% of all arterial catheterizations. CONCLUSION: Diagnostic cardiac catheterization and percutaneous transcatheter interventions can be performed with low mortality and acceptable morbidity in low weight infnats. Transcatheter interventions can replace surgery, postpone the necessity for surgery or stabilize the hemodynamic situation prior to surgery.

Birth Weight↗

[Iloprost as inhalational and intravenous long-term treatment of patients with primary pulmonary hypertension. Register of the Berlin Study Group for Pulmonary Hypertension]].

Follow-up data for 81 consecutive patients with primary pulmonary hypertension (PPH) and pulmonary hypertension related to connective tissue diseases or liver cirrhosis, entered into a multicenter registry in Berlin between 1/96 and 11/99, are described. At entry into the registry the diagnosis of PPH was known for 22 +/- 32 months. Hemodynamically, these patients were characterized by a right atrial pressure of 8.6 +/- 5 mmHg, a mean pulmonary arterial pressure of 58.9 +/- 17 mmHg, a cardiac index of 1.8 +/- 0.6 l/min/m2 and a pulmonary vascular resistance of 1574 +/- 787 dyn x s x cm-5. In about one third of the patients, a restrictive and/or obstructive pulmonary physiology was found while the majority showed signs compatible with small airway disease. Furthermore, diffusion abnormalities were found in about 65% of the patients. When added to conventional medical therapy the treatment with inhaled or continuously infused prostanoids represents a major improvement in the treatment of patients with PPH. Aerosolized iloprost therapy was started in 51 patients and was continued for 12 and 24 months in 20 and 6 patients, respectively. This therapy was well tolerated without any significant changes in pulmonary function or signs of toxicity. About 25% of these patients had to be switched to continuous intravenous therapy due to progressive clinical and hemodynamic deterioration. About two thirds of these "rescue patients" could be stabilized on intravenous therapy and discharged from the hospital. Based on the currently available evidence, the continuous infusion of prostanoids represents an important part of the standard therapy in the treatment of patients with PPH. These first long-term data on inhaled iloprost therapy in this patient group illustrate the potential value of this well-tolerated and effective treatment within the concept of a differentiated treatment plan for patients with PPH. However, the true importance of prostanoid inhalation in comparison to continuous intravenous therapy in PPH remains to be determined in randomized controlled trials.

Administration, Inhalation↗

[Artificial heart in terminal stage of dilated cardiomyopathy in childhood].

In children with dilated cardiomyopathy the disease may progress so rapidly that they die during the waiting period before a suitable donor organ is found. Fifteen children of 4 months to 15 years of age had been in congestive heart failure with multiorgan failure due to dilated cardiomyopathy, where intensive medical treatment had failed. After resuscitation, a miniaturized pulsatile ventricular assist device for the mechanical replacement of heart function was implanted. The biventricular assist device ("Berlin Heart") consists of two extracorporeal pneumatically driven polyurethane blood pumps, with a multi-layer flexible membrane that separates a blood and an air chamber. Four silicon cannulae connect the blood pumps to the patient. A three-leaflet valve prevents blood reflux. The pumps are driven by a pulsatile electropneumatic system. In 12 of the 15 children the bridging to transplantation was successful with a support time of 1 to 98 days (mean 24 days). Nine of them were extubated and mobilized while assisted. Three children died during the support time due to hemorrhage, sepsis, and pulmonary failure. In addition, there was one infarction of the arteria cerebri media. To date seven of the transplanted children are in good condition on follow-up. The beneficial effects of ventricular assist device use are well known in adult patients and with special devices it can be transferred to infants and children in whom longer need for support is anticipated. Even in small infants it is an effective method for bridging to cardiac transplantation.

Adolescent↗

Results of transvenous occlusion of secundum atrial septal defects with the fourth generation buttoned device: comparison with first, second and third generation devices. International Buttoned Device Trial Group.

OBJECTIVES: The purpose of this study was to assess safety and effectiveness of the fourth generation buttoned device in dosing atrial septal defects (ASDs) and to test the hypothesis that introduction of double button reduces unbuttoning rate without reducing effectiveness. BACKGROUND: Because of the high unbuttoning rate (7.2%) with first, second and third generation buttoned devices, the device was modified (fourth generation) so that there were two radiopaque spring buttons 4 mm apart on the button loop attached to the occluder. METHODS: During a four-year period ending in September 1997, 423 patients, ages 1.5 to 80 years (median 16 years), underwent closure of ASD at 40 medical centers around the world. RESULTS: The ASD size varied between 5 and 30 mm (median 17 mm). The device size varied between 25 and 60 mm. Unbuttoning occurred in 4 (0.9%) of 423 patients. Effective occlusion, defined as no (n = 343) or trivial (n = 34) residual shunt on echo-Doppler studies performed within 24 h of the procedure, was demonstrated in 377 patients (90%). Thus, the unbuttoning rate (0.9 vs. 7.2%) decreased (p<0.01) while effective occlusion rate (90 vs. 92%) remained unchanged (p>0.1) with this device, compared with earlier generation devices. During follow-up from one month to five years (23+/-15 months), 21 (5%) of 417 patients required surgical (n = 12) or transcatheter (n = 9) reintervention, mostly to treat significant residual shunt. In the remaining patients there was gradual reduction and disappearance of the residual shunt. No wire integrity problems were observed. CONCLUSIONS: These data suggest that the fourth generation buttoned device is as effective as earlier generation devices, but without significant unbuttoning. Follow-up results remained good, with a reintervention-free rate of 89% at five years.

Adolescent↗

An enzymatic procedure for the purification of DNA restriction fragments without gel electrophoresis and ethidium bromide staining.

A rapid and simple enzymatic method for the purification of a DNA fragment from a restriction digest was developed. The method is based on the two features of exonuclease III activity: digestion of DNA from a 3'-OH at blunt or recessed ends and failure to initiate digestion at DNA ends with four-base 3' overhangs. Herein, we establish a method for purification of a DNA restriction fragment without any physical separation via gel electrophoresis. The elimination of the ethidium bromide staining and ultraviolet irradiation steps should increase the quality and the safety of the purified DNA, a matter of major concern in the perspective of human gene therapy. In addition, since the method described does not use the visualization of the restriction fragments or their difference in size it can be used to purify a DNA fragment from a pool of DNA fragments with the same size even when microquantities of material are available.

DNA↗

Optimal conduit size for extracardiac Fontan operation.

BACKGROUND: Lack of conduit growth potential and thrombogenicity are the main drawbacks of the extracardiac Fontan operation (ECFO). Optimal size of the conduit according to the patients age and inferior vena cava diameter has not been established. OBJECTIVES: We set out to ascertain whether the optimal dimensions of the conduit could be determined before an ECFO. METHODS: Actual and expected age-related inferior vena cava diameters were compared with the extracardiac conduit diameter in 20 patients after ECFO. In 50 other pediatric and adult patients, the distance between intrapericardial part of the inferior vena cava and the undersurface of the right pulmonary artery (IVC-RPA) was measured. Cases of conduit thrombosis were analyzed. RESULTS: The actual diameter of the inferior vena cava was variable and has a weak correlation with anthropometric data and expected diameter (R=0.07-0.23, P=0.32-0.76). The IVC-RPA distance correlated with height (R=0.87, P=0.0001), but was also variable. At the age of 2-4 years and body weight 12-15 kg IVC diameter and IVC-RPA distance are equal to 60-80% of adult values. Conduit thrombosis developed in two patients with unfavorable Fontan hemodynamics and oversized conduits. CONCLUSIONS: Considering the inferior vena cava size, ECFO may be performed at the age of 2-3 years and at a body weight 12-15 kg, when a hemodynamically optimal almost adult sized conduit can be implanted. Optimization of the conduit is necessary on the basis of the actual inferior vena cava diameter and IVC-RPA distance. Anticoagulation postoperatively should be considered to prevent conduit thrombosis in patients with suboptimal Fontan circulation

Adolescent↗

Treatment of atrial septal defects in symptomatic children aged less than 2 years of age using the Amplatzer septal occluder.

AIMS: To assess results of closure of atrial septal defects within the oval fossa by devices delivered by catheterisation in symptomatic infants and children under 2 years of age. METHODS AND RESULTS: The Amplatzer septal occluder was used. Results, and complications of transcatheter device treatment in patients aged below 2 years were compared to previous results from our institution. PATIENTS: We attempted closure in 12 consecutive patients below the age of 2 years who presented with an atrial septal defect between May 1997 and 1999. Symptoms were failure to thrive in 6, frequent chest infections in 5, and the need for treatment of heart failure in the other. All were thought to have a defect suitable for interventional closure. The atrial defects were seen in isolation in 10 children, but 2 had associated pulmonary stenosis which had been treated by balloon dilation prior to placement of the Amplatzer occluder. RESULTS: The Amplatzer septal occluder was implanted at a mean age of 1.4 +/- 0.4, with a range from 0.8 to 1.8 years. Ratios of pulmonary-to-systemic flow had been 2.1 +/- 0.5, with a range from 1.6 and 3.2, and the defect was measured at 12 +/- 4 mms. Fluoroscopy time was 12.8 +/- 10.2 minutes, with a range from 5 to 43 minutes, and the time of the overall procedure was 162 +/- 70 minutes, with a range from 85 to 360 minutes. It proved necessary to remove the device in 2 patients (16%) because of a residual shunt and movement after release. One of these developed transient neurological complications. Both subsequently underwent surgical treatment. CONCLUSION: Symptomatic patients less than 2 years of age can undergo successful closure of an atrial septal defect using the Amplatzer device, but the rates of success are less, and procedure time longer, than in older children or adults.

Cardiac Catheterization↗

Intracranial pseudolymphoma.

Intracranial pseudolymphoma is a rare tumor of the central nervous system. A 35-year-old woman presented with a frontal subcutaneous tumor. Magnetic resonance imaging revealed a left frontal meningeal tumor involving subcutaneous tissue without bone involvement. The mass was completely removed and the histological aspect of all tumor sections was that of a lymphoid hyperplasia with polyclonal proliferation. These findings were characteristic of pseudolymphoma defined as a hyperplasia of follicular and diffuse lymphoid type with assessment of its polyclonality by immunophenotyping on frozen sections, completed by molecular biology techniques.

Adult↗

Transcatheter closure of multiple atrial septal defects. Initial results and value of two- and three-dimensional transoesophageal echocardiography.

AIMS: To examine the feasibility of transcatheter closure of multiple atrial septal defects using two Amplatzer devices simultaneously and to describe the importance and the role of two- and three-dimensional transoesophageal echocardiography in the selection and closure of such defects. METHODS: Twenty-two patients with more than one atrial septal defect underwent an attempt at transcatheter closure of their atrial septal defects at a mean+/-SD age of 30. 8+/-18.6 years (range 3.7-65.9 years) and mean weight of 56.6+/-25.5 kg (range 12.9-99 kg) using two Amplatzer devices implanted simultaneously via two separate delivery systems. During catheterization, two dimensional transoesophageal echocardiography was performed in all but one patient, during and after transcatheter closure, while three dimensional transoesophageal echocardiography was performed in six patients before and after transcatheter closure. RESULTS: Forty-four devices were deployed in all patients to close 45 defects (one patient with three defects closed by two devices). Two dimensional transoesophageal echocardiography was helpful in selection and in guiding correct deployment of the devices. The mean size of the larger defect, as measured by transoesophageal echocardiography was 12.8+/-5.9 mm and the mean size of the smaller defect was 6.6+/-3.0 mm. The mean size of the larger devices was 15+/-7.5 mm, and 8.4+/-3.7 mm for the smaller. Three dimensional transoesophageal echocardiography provided superior imaging and demonstrated the number, shape and the surrounding structures of the atrial septal defects in one single view. The median fluoroscopy time was 28.7 min. Device embolization with successful catheter retrieval occurred in one patient. Forty-four devices were evaluated by colour Doppler transoesophageal echocardiography immediately after the catheterization with a successful closure rate of 97.7%. On follow-up colour Doppler transthoracic echocardiography demonstrated successful closure in 97.5% at 3 months. CONCLUSIONS: The use of more than one Amplatzer septal occluder to close multiple atrial septal defects is safe and effective. The use of two- and three-dimensional transoesophageal echocardiography provided useful information for transcatheter closure of multiple atrial septal defects using two devices. Three-dimensional transoesophageal echocardiography enhanced our ability to image and understand the spatial relationship of the atrial septal defect anatomy.

Adolescent↗

Late-diastolic forward flow in the aorta induced by left atrial contraction.

Late-diastolic forward flow is a well-described phenomenon detectable by Doppler echocardiography in the pulmonary trunk. It is supported by a restrictive right ventricular diastolic function and by a low end-diastolic pulmonary artery pressure. A similar phenomenon for the left ventricle and the aorta has not been described. We report a case of a preterm infant with aortic stenosis and endocardial fibroelastosis, who underwent balloon valvuloplasty. Restrictive left ventricular diastolic filling led to high left atrial pressure (27 mm Hg) and a very pathologic ratio of early-to-late peak velocities (2.6) for an infant of 29 weeks' gestation. In combination with a low diastolic aortic pressure (24 mm Hg) caused by moderate aortic regurgitation after intervention, a late-diastolic forward flow was detectable in the aorta during left atrial contraction with pulsed Doppler echocardiography.

Aorta↗

Liver injury due to tetrabamate (Atrium): an analysis of 11 cases.

BACKGROUND: Tetrabamate (Atriums), widely used in the treatment of tremor and ethanol-withdrawal symptoms, has been incriminated as a potential cause of reversible acute hepatitis. OBJECTIVE: We report here on 11 patients who experienced tetrabamate-related liver injury, in order to evaluate their clinical, histopathological and evolutive features. PATIENTS AND METHODS: Between 1987 and 1998, 34 cases of tetrabamate-associated acute hepatitis were spontaneously reported to the regional pharmacovigilance center of Lyon. Eleven cases were considered probably to be drug-induced. RESULTS: There were three males and eight females aged 31-82 years (mean, 57 years). The duration of treatment ranged from 33 to 206 days, and indication for treatment was depressive disorders, tremor or prevention of alcohol withdrawal symptoms. Clinical symptoms were asthenia (n = 9), jaundice (n = 3) and/or diffuse rash (n = 3). The pattern of liver injury was cytolytic (n = 10) or cholestatic (n = 1). Three patients presented biological features of hepatic failure. A percutaneous liver biopsy was performed in six patients. Histological examination of the liver specimen showed a large spectrum of lesions: massive hepatocellular necrosis (n = 1), centrilobular and nonconfluent hepatocyte necrosis (n = 2), intracellular cholestasis (n = 3), and granulomatous hepatitis (n = 1). Tetrabamate was discontinued in all patients. In seven patients, a complete recovery was observed 3 weeks to 3 months after drug withdrawal. Two patients, despite a rapid improvement of liver function tests, died from unrelated causes. The remaining two patients died from irreversible hepatic failure. CONCLUSIONS: Our data strongly suggest that tetrabamate may induce acute liver injury, which may eventually result in life-threatening liver failure.

Adult↗

Diagnostic catheterization and balloon sizing of atrial septal defects by echocardiographic guidance without fluoroscopy.

To avoid x-ray exposure prior to interventional closure of atrial septal defects (ASDs), we recently developed a technique for diagnostic catheterization and balloon sizing of the defect by echocardiographic guidance without fluoroscopy. We report on our first experiences with this technique. Fourteen patients with atrial septal perforations (mean age, 23 years; range, 1-66 years) underwent diagnostic catheterization and balloon sizing prior to possible interventional defect closure. Mean size of the defects was 16 mm (7-29 mm). Mean left-to-right shunt was Qp/Qs = 2.0 (range, 1.0-4.0). Without fluoroscopy, the procedures were performed in two children by transthoracic echocardiography (TTE) and in 12 patients by both TTE and transesophageal echocardiography (TEE). Mean procedure time was 59 minutes (range, 35-90 minutes). We conclude that oxymetry, pressure recordings, and the estimation of the balloon-stretched size of atrial septal perforations can be performed safely by echocardiographic guidance without fluoroscopy. The x-ray exposure for patient selection prior to a transcatheter closure of an ASD can be avoided with this technique.

Adolescent↗

Presence of sorbin in human digestive tract and endocrine digestive tumours.

BACKGROUND: Sorbin, a 153 amino acid peptide isolated from porcine intestine, was localised by immunohistochemistry in endocrine cells of the intestinal mucosa and pancreas and in the enteric nervous system in the pig. AIMS: To identify sorbin cells in normal human digestive tissues and to explore the expression of sorbin in 37 digestive endocrine tumours: 14 intestinal carcinoid tumours and 23 endocrine pancreatic tumours including six insulinomas. METHODS: Two polyclonal antibodies against the C-terminal and the N-terminal sequences of porcine sorbin raised in rabbit were used to evaluate sorbin expression by immunohistochemistry. RESULTS: In the human digestive tract, sorbin, characterised by both C-terminal and N-terminal immunoreactivity, was found in enterochromaffin cells of the gastric and intestinal epithelium from the pyloric junction to the descending colon. C-Terminal sorbin immunoreactivity alone was found in plexii from the enteric nervous system and in some insulin-containing cells of normal pancreas. C-Terminal and N-terminal antibodies disclosed sorbin in five of 14 intestinal carcinoid tumours; C-terminal antibody alone disclosed a C-terminal sorbin peptide in two of six insulinomas and three of 17 endocrine pancreatic tumours. The presence of sorbin was not associated with a specific clinical syndrome. CONCLUSIONS: Sorbin is present in the digestive tract in several forms. It is expressed in some intestinal and pancreatic endocrine tumours.

Aged↗

Morphology of perforated atrial septal aneurysm suitable for closure by transcatheter device placement.

OBJECTIVE: To define the morphological criteria of perforated atrial septal aneurysms suitable for closure by a transcatheter device. METHODS: A retrospective analysis of all consecutive patients with atrial septal aneurysm and one or more perforations presenting between May 1997 and June 1999. The aneurysms were classified as: aneurysm with persistent foramen ovale (type A); aneurysm with single atrial septal defect (type B); aneurysm with two perforations requiring more than one device for closure (type C); and aneurysm with multiple perforations (type D). PATIENTS: Data from 50 patients aged 5-78 years (mean 43 years) were analysed; 32 had systemic thromboembolism or transient ischaemic attacks, eight presented with dyspnoea on exercise, and 10 were discovered incidentally but had significant left to right shunt and right ventricular volume overload. RESULTS: In all 18 patients with aneurysm and persistent foramen ovale (type A), transcatheter closure was possible. In nine with aneurysm and atrial septal defect (type B), five defects were closed and four required surgery. Device closure was achieved in all 10 patients with aneurysms and two perforations (type C), but four had a residual shunt. Thirteen patients with multiple perforated aneurysms (type D) underwent surgery. CONCLUSIONS: This classification of morphology of perforations of aneurysm is clinically useful for selecting patients for treatment by transcatheter devices.

Adolescent↗

[Regional transcranial oximetry with near infrared spectroscopy (NIRS) in comparison with measuring oxygen saturation in the jugular bulb in infants and children for monitoring cerebral oxygenation].

Using a dual channel near infrared (NIR) in vivo optical spectroscopy (INVOS) system (INVOS 3100A, Somanetics Corp. Troy, MI, USA) we investigated the relationship between jugular venous oxygen saturation (SjvO2) and regional cerebral oxygen saturation (rSO2) in 30 infants and children (mean age 4.5 years) with congenital heart disease undergoing cardiac catheterisation. The NIRS-SomaSensor (emitter and dual receiver probe) was applied at a standardised right fronto-temporal location (over the right frontal cortex) on the infant's head and covered with an adhesive flexible bandage. Using NIR light (730 and 810 nm) and two source-detector spacings (3 and 4 cm from the transmitter), percentage values of rSO2 were calculated from detected haemoglobin saturations. Simultaneously, jugular venous oxygen saturation (SjvO2) monitoring was performed via a catheter placed in the right internal jugular vein with its tip positioned in the jugular bulb, as verified by fluoroscopy. To compare the reliability of NIRS measurement characteristics, jugular venous blood was analysed for SjvO2 as a reference measure of global cerebral oxygenation, by co-oximetry (OSM3-Hemoximeter, Radiometer Copenhagen, Denmark). Other measured variables included pulse oximetry, arterial blood pressure, and venous and arterial oxygen saturations. Over a jugular venous oxygen saturation range of 31-83%, a significant positive linear correlation was found between rSO2 (NIRS measurement) and SjvO2 (jugular bulb oximetry) (r = 0.93, p < 0.001). No significant correlation was observed between rSO2 values and arterial blood saturation or pulse oximetry. The quantitative correlation between rSO2 (haemoglobin oxygenation in a small hemi-elliptical area of the brain) and reference SjvO2 measurement (method for monitoring global cerebral oxygenation) suggests that NIRS measurement with subtraction algorithm should identify predominantly intracranial saturation in the pediatric age group, and will tend to reflect global oxygenation under physiological conditions. Transcranial oximetry using dual receiving channel NIRS offers a noninvasive, real-time, reliable and practicable means of monitoring cerebral haemoglobin oxygenation changes infants and children with cyanotic and noncyanotic congenital heart disease.

Adolescent↗