PubMed Health⌕ Search

Biomedical subjects

F Dannheim

Publications and source records attributed to F Dannheim.

At least 19 recordsLinked to original sources

[Conventional perimetry. Part 3: Static perimetry: grid--strategy--visualisation].

Methods for visual field examination using static strategies began with manual static profile perimetry. The transition from a linear stimulus alignment along the profile section to a two-dimensional grid arrangement introduced the era of static grid perimetry. The use of computers makes it possible to automate and standardise this process, allowing the examiner to choose the visual field area, an adequate grid and the optimal strategy, while leaving the processing, visualisation and recording completely observer-independent. This contribution is based only on conventional static procedures for visual field examination (the use of white on white perimetry) as this technique is easily accessible, standardised and well established in everyday practice.

Diagnosis, Computer-Assisted↗

[Conventional techniques of visual field examination: part 4 Static perimetry: interpretation--perimetric indices--follow-up--perimetry in childhood].

Visual field examination with fixed stimuli was first realized in manual static profile perimetry. The transition from a linear stimulus alignment along a profile section towards a two-dimensional arrangement introduced the era of static grid perimetry. Application of computer technology nowadays allows automation and standardization of this procedure, which enables the examiner to select the necessary visual field area, the adequate grid, and the optimal strategy for an estimation of differential luminance sensitivity. Furthermore, the computer independently takes over the recording, visualization, and processing of the perimetric procedure. This contribution discusses conventional static visual field examinations since these are widely used, easily accessible, well established for practical application, and standardized. This paper (part 4) explicitly focuses on the correct interpretation of automated static strategies of visual field examinations. Furthermore the classification and scoring of visual field defects as well as quality control, progression analysis, and perimetry in childhood are addressed. This manuscript is based on three preceding parts, which were published in previous issues of this journal [27, 28, 29].

Child↗

[Conventional perimetry I: introduction--basics].

Evaluation of visual field findings is an essential ophthalmological task. Applying psychophysical principles enables non-invasive (topo-)diagnostics in case of unexplained visual loss or suspected lesions of the visual pathways. Furthermore, any kind of expert opinion or ability test depends critically on adequate visual field findings. Repeated examinations allow the functional follow-up of a disease and judgement of therapeutic efficiency. This paper is explicitly focused on conventional strategies of visual field examination, since these are widespread, easily accessible, standardized and well established in everyday practice. Part 1 of this continuing education series will mainly impart basic concepts in perimetry and psychophysics. It will also consider indications and the necessary general setup of a perimetric examination. Furthermore, a concept of scotoma classification is explained.

Humans↗

[Conventional techniques of visual field examination Part 2: confrontation visual field testing -- kinetic perimetry].

Evaluation of visual field findings is an essential ophthalmological task. Applying psychophysical principles enables noninvasive (topo-)diagnosis in cases of unexplained visual loss or suspected lesions of the visual pathway. Furthermore, any kind of expert opinion or ability test critically depends on adequate visual field findings. Repeated examinations allow functional follow-up of a disease and assessment of therapeutic efficiency. This paper explicitly focuses on conventional strategies since these are widespread, easily accessible, standardized, and well established in everyday practice over years. Standardized white-on-white perimetry with moving targets (kinetic perimetry) is the major topic of this paper (part 2) in addition to "rough"/preliminary confrontation visual field testing. This review series is aimed at imparting basic concepts in perimetry and psychophysics to ophthalmologists and also addresses interested physicians from other disciplines.

Eye Movements↗

[Topometry of the optic papilla with the glaucoma-scope].

Reproducibility of measurements of the "Glaucoma-Scope", a new topometric device (software version 3.12), was assessed by optic disk analysis of 10 eyes in 10 healthy subjects. Each analysis was carried out by 4 independent observers. Examinations of one of these eyes were repeated 10 times by each one of the 4 observers. The instrument was also applied to a sample of 117 eyes in 60 patients from a glaucoma clinic. The minimal requirements were determined to be a pupil diameter of 5 mm and lens-related visual acuity > 0.8. The coefficient of variation for the different optic disk parameters in the repeated examinations ranged from 3.5% to 15.7%. The maximal discrepancy between values of vertical C/D ratio within any of the subjects ranged from 0.01 to 0.12 (mean 0.05). Glaucoma-Scope measurements revealed a smaller value for disk area than those from computer-assisted manual planimetry, with a constant factor of 0.81. The measurement of vertical C/D ratio by Glaucoma-Scope and a stereoscopic estimate correlated highly in a subset consisting of 20 glaucoma patients and the 10 healthy subjects (r = 0.786; p < 0.0001). A considerable discrepancy (larger or smaller) was apparent between values found through clinical inspection of 6 of the 117 eyes (4 of 60 patients) and those found with the Glaucoma-Scope. In these 6 eyes subsequent analyses utilizing a more recent software version yielded a good correlation between the two methods. The Glaucoma-Scope allows sufficiently reproducible optic disk topometry.

Adolescent↗

[Chronic open angle glaucoma: correlation of pattern electroretinography and visual field indices].

The pattern electroretinogram has already proven to be useful in detecting early stages of chronic open-angle glaucoma. We were interested in the degree of correlation between pattern ERG amplitudes and definite visual field defects. Fifteen glaucoma patients with a wide range of visual field defects were examined with pattern electroretinogram (stimulus with reversal rate of 8/s, checksizes of 0.9 degree and 6.9 degrees, covering a visual field of up to 9 degrees eccentricity). The patients' visual fields obtained with the Octopus 1-2-3 perimeter were analyzed with the perimetric analysis system PERIDATA using the indices of conformity for localized defects and the regional indices created from the mean deviation in certain parts of the 30 degrees field. In our results we were only able to find a significant correlation within the 5% level between the pattern ERG amplitudes and the sector index (large checksize, correlation coefficient r = -0.58, p = 0.03) and with the mean deviation in the region between 10 degrees and 20 degrees (small checksize, r = -0.538, p = 0.044). In summary, a marginal correlation between electrophysiological data and perimetric parameters was demonstrated. We try to explain the remarkable correlation between the amplitudes (small pattern) that were recorded from the central 9 degrees with the mean defects from the visual field peripheral of 10 degrees with the frequent combination of diffuse and localized field defects in glaucoma. Examination with the pattern ERG alone does not seem to be appropriate for grading the focal glaucomatous damage.

Adult↗

[Pattern electroretinography in routine clinical diagnosis of open angle glaucoma].

According to current opinion, the pattern electroretinogram (ERG) is generated in the retinal ganglion cells. Therefore, the amplitude is expected to be reduced in diseases of the optic nerve. This leads to the conclusion that the pattern ERG might be applied in detecting ganglion cell loss in the routine clinical diagnosis of chronic open-angle glaucoma. Pattern ERGs were recorded in 15 patients with defined chronic open-angle glaucoma and 21 control individuals using a DTL fiber electrode at two different check sizes. A Fourier analysis of the ERG results reduces the subjectivity when analysing the amplitudes on screen and implies the possibility of multicentric comparability. The reliability of coordinating a value of a future patient to the correct group was estimated to 82% for the Fourier data by the bivariate discriminant analysis, based on the amplitudes of both check sizes. In this way, the relatively high interindividual variability will be partly overcome. The ability of the ERG amplitudes to separate glaucoma patients from healthy persons was determined by the AUC value, using a combination of sensitivity and specificity extracted from the ROC curves. The AUC value has its maximum at 1.0. We found an AUC value of 0.8, which confirmed the information given by the pattern ERG amplitudes. Healthy individuals and glaucoma patients cannot be separated completely by the procedure but, combined with additional clinical parameters, further validation can be achieved.

Adult↗

Sensitivity and specificity of optic disc parameters in chronic glaucoma.

PURPOSE: Optic disc parameters are commonly used for the early detection of glaucomatous optic discs. We used receiver operating characteristics (ROC) curves to illustrate the separation characteristics of different disc parameters for this purpose. METHODS: We performed computer perimetry and computerized optic disc topometry on 93 eyes of 53 subjects with glaucoma and glaucoma-related diseases. The optic disc parameters were correlated with visual field indexes, and ROC curves for the detection of glaucomatous disc changes were calculated. RESULTS: According to clinical experience, the vertical cup/disc ratio was able to identify the glaucomatous eyes the most easily, whereas the neuroretinal rim area was less helpful in this regard. In terms of the correlation of optic disc parameters with visual field indexes, the rim area was the more powerful of the two. The cup volume showed neither separation of glaucomatous from normal eyes nor correlation with visual field indexes. CONCLUSIONS: The vertical cup-to-disc ratio is the most suitable for screening purposes, whereas the rim area is more valuable for follow-up evaluation.

Chronic Disease↗

The topographical relationship between optic disc and visual field in glaucoma.

The spatial relationship between anatomy and function in glaucoma was studied in 15 selected cases of focal damage. Based on planimetric data of the optic disc the anatomical site of damage was defined as the sector with the thinnest neuroretinal rim. Perimetric data were evaluated with regard to 21 regions of the 'Perimetric Nerve Fibre Bundle Map' (Weber & Ulrich 1990a). The site of damage was defined as those regions with at least 50% of depressed points. The site of the affected rim and the number of the corresponding Perimetric Nerve Fiber Bundles showed a linear correlation over a limited range of the superior and inferior pole of the disc. A 'functional disc map' could be established for 6 perimetric regions.

Glaucoma↗

[Peritest].

Explore the source record for details and available documents.

Glaucoma↗

The Peritest, a new automatic and semi-automatic perimeter.

The Peritest is a new automatic and semi-automatic (manual) perimeter for detection and limited assessment of visual field defects. It uses either multiple or single stimulus static perimetry. The lightsources are LED's. A total of 206 positions can be examined including the center; 151 positions inside 25 degrees-eccentricity. The programmes use a threshold-related gradient adapted suprathreshold (0.6) strategy. The results are printed on a special chart using non-interpolated grey scales for indicating local reduction of sensitivity. General and local reduction of sensitivity are separated. The progress of the examination can be followed on a LED-monitor. The reliability of the patient is measured. 70% of small early glaucomatous defects (that are only found by high resolution meridional static perimetry) were detected. Such defects are not usually detected by routine kinetic perimetry. More peripheral defects were detected (greater than 25 degrees) than by kinetic perimetry. Due to the relatively high number of stimuli the typical configuration of defects was satisfactorily demonstrated for defects of moderate size and larger. The duration of the examination varies from less than 4 min. for a semi-automatic examination of normal eyes to 10-20 min. for automatic examination of eyes with defects of moderate size (average 15 minutes for 206 positions).

Glaucoma↗