The Peritest, a new automatic and semi-automatic perimeter.

Abstract

The Peritest is a new automatic and semi-automatic (manual) perimeter for detection and limited assessment of visual field defects. It uses either multiple or single stimulus static perimetry. The lightsources are LED's. A total of 206 positions can be examined including the center; 151 positions inside 25 degrees-eccentricity. The programmes use a threshold-related gradient adapted suprathreshold (0.6) strategy. The results are printed on a special chart using non-interpolated grey scales for indicating local reduction of sensitivity. General and local reduction of sensitivity are separated. The progress of the examination can be followed on a LED-monitor. The reliability of the patient is measured. 70% of small early glaucomatous defects (that are only found by high resolution meridional static perimetry) were detected. Such defects are not usually detected by routine kinetic perimetry. More peripheral defects were detected (greater than 25 degrees) than by kinetic perimetry. Due to the relatively high number of stimuli the typical configuration of defects was satisfactorily demonstrated for defects of moderate size and larger. The duration of the examination varies from less than 4 min. for a semi-automatic examination of normal eyes to 10-20 min. for automatic examination of eyes with defects of moderate size (average 15 minutes for 206 positions).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E L Greve, F Dannheim, D Bakker. 1982. The Peritest, a new automatic and semi-automatic perimeter.. https://doi.org/10.1007/bf00149155

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Do scleral flap dimensions influence reliability of intraocular pressure control in experimental trabeculectomy?

AIM: To compare the effect on intraocular pressure (IOP) of large vs small scleral flap size during trabeculectomy using adjustable sutures. METHODS: Trabeculectomy operations were performed on nine donor human eyes connected to a constant flow infusion with real-time IOP monitoring. Large scleral flaps (4 x 4 mm, 16 mm(2), n=12) or small scleral flaps (3 x 2 mm, 6 mm(2), n=9) were constructed over 0.76 mm(2) sclerostomies. For each procedure, equilibrium IOP was measured following tight closure with two four-throw adjustable 10-0 nylon sutures. RESULTS: Five scleral flaps were thin or poorly constructed; four of these were in the initial seven procedures, implying learning effect. These had a mean absolute IOP of 7.6 mmHg (range 2.7-12.4 mmHg) and mean relative IOP of 28.3% of baseline (range 10-45.8%) after closure. In the remaining 16 good quality procedures, mean IOP was 1.3 mmHg (range 0-3.4 mmHg) after sclerostomy, confirming minimal outflow resistance before closure. Following flap closure mean IOP was 20 mmHg (SD 4.4, range 15.5-29.3 mmHg) for large (n=8), and 18.7 mmHg (SD 3.6, 15.9-25.8 mmHg) for small (n=8) flaps (unpaired t-test, P=0.26). Mean IOP (% baseline) was 71.6% (SD 8.4, range 60.6-86.6%) and 66% (SD=12.7, 46.8-86.6%) for large and small flap groups, respectively (unpaired t-test, P=0.2). CONCLUSIONS: Well-constructed scleral flaps of both sizes were able to support an average IOP at least two-thirds of baseline, and both had similar absolute IOP levels. Errors in flap construction resulted in loss of IOP control. Smaller flap size does not appear to compromise control of early postoperative IOP using adjustable sutures.

Glaucoma↗