PubMed Health⌕ Search

Biomedical subjects

F Diekmann

Publications and source records attributed to F Diekmann.

At least 19 recordsLinked to original sources

Evolution of proteinuria after conversion from calcineurin inhibitors (CNI) to sirolimus (SRL) in renal transplant patients: a multicenter study.

Conversion from calcineurin inhibitors (CNI) to sirolimus (SRL) has become an option in patients with chronic allograft nephropathy or other conditions. However, in some cases an increase of proteinuria has been reported after such therapeutic intervention. The aim of this study was to characterize the clinical course of this so far unexplained proteinuria after conversion. We performed a retrospective analysis evaluating 94 renal transplant patients from various Spanish centers. Proteinuria (629 determinations) and clinical developments were analyzed between 6 months before and 6 months after conversion. Patients were divided into three groups according to mean proteinuria before conversion (group A: <300 mg/d; group B: 300 to 2000 mg/d; and group C: >2 g/d). The mean proteinuria level was 1.69 g/24 h (n = 312 determinations) before and 2.36 g/24 h after conversion (n = 317 determinations; P = .006), which corresponds to an overall increase of 25% (1.55 to 1.69 g/24 h considering only determinations of 1 month before and 1 month after conversion; P = NS). We could not detect any clear correlation between proteinuria and serum creatinine nor between changes of proteinuria and changes of serum creatinine. A variance analysis for repeated measures showed an increase in proteinuria compared to the preconversion values (P = .003), and when the three groups of preconversion proteinuria were evaluated separately it could be observed that this change in the evolution of proteinuria was almost completely dependent of an increase in the group C (preconversion proteinuria greater than 2 g/d; P = .03), whereas in the other two groups changes were almost irrelevant. Finally, the switch to SRL in renal transplant recipients is followed by an increase in the level of proteinuria predominantly dependent of an increase in patients with high levels of preconversion proteinuria, whereas it seems to be irrelevant in patients without or with light or moderate proteinuria. These results suggest that this might not be a direct effect of SRL.

Calcineurin Inhibitors↗

Enteric-coated mycophenolate sodium: safe conversion from mycophenolate mofetil in maintenance renal transplant recipients.

Mycophenolate mofetil (MMF), in combination with cyclosporine and corticosteroids, improves long-term graft function and survival in renal transplant recipients. However, optimal MMF therapy may be limited by gastrointestinal (GI) intolerance, which may result in the need for MMF dose reduction, interruption, or discontinuation, leading to increased risk of acute rejection. Enteric-coated mycophenolate sodium (EC-MPS) is an advanced formulation delivering mycophenolic acid (MPA), developed with the objective of improving MPA-related upper GI adverse events. A pivotal, 12-month, phase III, randomized, multicenter, double-blind, double-dummy, parallel group study investigated whether stable renal transplant patients can be converted from MMF to EC-MPS therapy without compromising tolerability or efficacy. Stable renal transplant recipients received either MMF, 1000 mg b.i.d. (n=159), or EC-MPS, 720 mg b.i.d. (n=163), for 12 months. The incidence of GI adverse events was comparable between both treatment groups at 3 and 6 months, but there was a trend toward reduced severity of GI side effects in the EC-MPS group. There were fewer serious adverse events with EC-MPS and significantly fewer serious infections (P<.05). This comparable safety profile for EC-MPS and MMF also extended to elderly patients and patients with diabetes at baseline. For the composite efficacy variable of biopsy-proven acute rejection, graft loss, death, or loss to follow-up, EC-MPS had a lower 12-month efficacy failure rate (EC-MPS: 7.5% vs MMF: 12.3%; P=ns). These data demonstrate that stable renal transplant recipients receiving MMF can be converted to EC-MPS with no efficacy or tolerability compromise.

Adult↗

Early postoperative ultrasound of kidney transplants: evaluation of contrast medium dynamics using time-intensity curves.

OBJECTIVE: To evaluate kidney recipients in the early posttransplant phase by semiquantitative analysis of the arterial arrival of ultrasound (US) contrast medium using time-intensity curves. PATIENTS AND METHODS: Twenty-two kidney recipients underwent US examination after intravenous bolus administration of 2.4 ml of US contrast medium (SonoVue, Bracco Altana) 5 to 7 days after transplantation. The examinations were performed with the Aplio US system (Toshiba) and a 3.5-MHz wideband transducer using contrast harmonic imaging at a low mechanical index of 0.1. Arterial arrival was documented digitally over 60 sec (image repetition rate: 10 images per sec) for subsequent evaluation of contrast medium kinetics in the main renal artery, interlobar artery, subcapsular area, and renal vein using the system's integrated time-intensity curve (TIC) software. The increase, decrease, and percentage enhancement factor were calculated from the curves. Four patients were excluded from analysis because of perirenal hematoma (n = 3) or a polar perfusion loss demonstrated by power Doppler (n = 1). RESULTS: Twelve of the remaining 18 patients assigned to the nonrejection group showed an uneventful clinical course. These had uniform TICs with an early and steep increase of similar magnitude in the main renal artery (11.7 +/- 4.5 intensity units/sec), interlobar artery (8.7 +/- 4.6 intensity units/sec), and subcapsular area (8.3 +/- 3.7 intensity units/sec) followed by a washout and subsequent plateau phase. Six patients showed histologically proven acute rejection on day 5 or 6 after transplantation (rejection group). This group had a delayed (time to peak in the subcapsular area: 32.9 +/- 8.3 sec in the rejection group versus 20.9 +/- 4.7 sec in the nonrejection group, p < 0.05) and smaller subcapsular percentage increase (41.2 +/- 21.9 % versus 114.4 +/- 59.8 %, p < 0.05). In the rejection group the subcapsular area (3.8 +/- 2.3 intensity units/sec) showed a less pronounced increase than the main renal artery (7.9 +/- 5.9 intensity units/sec) and interlobar artery (8.7 +/- 3.8 intensity units/sec). The RI in the rejection group was in the normal range at the time of contrast-enhanced US (day 5: 0.78 +/- 0.06) and increased to abnormal levels in the further course (day 7: 0.94 +/- 0.09). CONCLUSIONS: Quantitative determination of arterial arrival of an US contrast medium in the early phase after kidney transplantation is possible. This new US procedure might identify acute rejection earlier than conventional techniques.

Adult↗

[Preoperative MRT of the breast in invasive lobular carcinoma in comparison with invasive ductal carcinoma].

PURPOSE: To evaluate the role of preoperative MRI of the breast in invasive lobular carcinoma (ILC) compared to invasive ductal carcinoma (IDC). MATERIALS AND METHODS: For one year, all patients transferred by the hospital's gynecologic outpatient service for suspicious findings in routine mammography and/or ultrasound (conventional modalities = CM) underwent preoperative MRI of the breast. Retrospective analysis of the histologic findings identified 17 patients with ILC. These were compared with 30 proven IDC patients, chosen by random. The MRI findings of these 2 patient groups were compared with regard to the detection of additional lesions. The average number of additional lesions detected by MRI was compared for significant differences between both groups using the T-test for paired samples. RESULTS: In the 17 patients with ILC, conventional modalities (CM) identified 21malignant lesions whereas MRI detected a total of 30 lesions. At least one additional lesion was detected by MRI in 7 of the 17 patients with ILC. In the 30 patients with IDC, on the other hand, MRI detected an additional lesion in three instances only. In one patient of the ILC group, MRI identified an additional lesion in the contralateral breast that had escaped detection by CM. No additional contralateral lesion was detected by MRI in any of the IDC patients. Benefit of MRI in ILC-Group: The mean numbers of detected malignant lesions differed significantly between diagnosis by MRI and CM in the ILC group (1.77 carcinomas per patient with MRI versus 1.24 with conventional modalities, T-test, p = 0.0078). Benefit of MRI in IDC-Group: although it was possible to find 1.27 carcinomas vs. 1.17 carcinomas per patient in the IDC-Group, this benefit was not statistical significant (T-test, p = 0.0831). CONCLUSION: Preoperative MRI detects multiple additional lesions compared to the ones already known by CM. The higher incidence of multiple lesions in ILC compared to IDC and the difficult diagnosis of ILC in CM might be the reason for the fact that preoperative MRI is particularly useful in patients with ILC.

Breast↗

Evaluation of a wavelet-based computer-assisted detection system for identifying microcalcifications in digital full-field mammography.

PURPOSE: To evaluate a new wavelet-based computer-assisted detection (CAD) system for detecting and enhancing microcalcifications. MATERIAL AND METHODS: A total of 280 mammograms acquired by full-field digital mammography (Senographe 2000D; G.E. Medical Systems Milwaukee, Wisc., USA) were analyzed with and without a new wavelet-based CAD system for detecting and enhancing microcalcifications. The mammograms comprised roughly equal numbers of cases from each of the BIRADS (Breast Imaging, Reporting and Data System, according to the American College of Roentgenology) categories 1-5. Histologic confirmation was available for all of the 180 cases assigned BIRADS categories 3-5. Four readers interpreted all 280 images for suspicious microcalcifications using a scale of 1-5. The readers alternately assessed 5 images with and 5 without CAD. In a second reading immediately following the first, the readers had to reassess the 280 mammograms. The images that had already been interpreted without CAD were now presented with CAD and vice versa. The images were interpreted as soft copies on a diagnostic mammography workstation (Image Diagnost GmbH, Neufahrn/Munich, Germany). All images interpreted with CAD were presented with enhancement of microcalcifications by wavelet algorithms and prompting of microcalcifications. ROC (receiver operating characteristic) analyses were performed, and image interpretation time with and without CAD was measured. RESULTS: The overall time for interpretation required by all 4 readers together was 483 min with CAD compared to 580 min without CAD. ROC analysis revealed no significant advantage of CAD for the individual readers. Readers 3 (0.811/0.817) and 4 (0.799/0.843) had a slightly improved AUC (area under the curve) with CAD. Readers 1 and 2 had a slightly lower AUC with CAD (0.832 versus 0.861 and 0.818 versus 0.849). CONCLUSION: The CAD system significantly (P<0.05, t test) speeded up image interpretation with respect to the identification of microcalcifications, while the diagnostic quality remained almost identical under the study conditions.

Breast Diseases↗

Use of iodine-based contrast media in digital full-field mammography--initial experience.

AIM: To investigate the use of iodine-based contrast media in digital full-field mammography. METHODS: After performing initial phantom studies, seven patients underwent digital mammography (Senographe 2000D, GE Medical Systems, Milwaukee, USA) using a specially filtered beam before as well as 60, 120, and 180 seconds after injection of 80 ml of iodine contrast medium (Ultravist 370, Schering AG, Germany). The precontrast mammograms were then subtracted from the postcontrast mammograms and the resulting images compared with a contrast-enhanced dynamic MRI study, performed on all women. RESULTS: Contrast medium accumulation within the tumors was visualized with a good quality in all cases. The conditions under which successful contrast-enhanced digital mammography can be performed were determined in phantom studies. CONCLUSIONS: Contrast-enhanced digital mammography has a potential for improving the visualization of breast tumors in mammography using special beam filtering, adjusted x-ray parameters, proper timing, and suitable subtraction software.

Breast Neoplasms↗

[Dose reduction through gridless technique in digital full-field mammography].

PURPOSE: To determine the role of the scatter grid in digital full-field mammography with respect to image quality and dose and to compare the experimental results with initial clinical experience. MATERIALS AND METHODS: A phantom consisting of 205 fields that enclose gold dots of different thickness and size (CD-Mam phantom, Medical Department, Nijmegen, Netherlands) was used for digital full-field mammography with the conventional grid module and a special gridless module. Four different breast thicknesses were simulated using Plexiglas as scatter material. First, the phantom was exposed at the parameter and dose settings automatically selected in each experimental setup (with and without grid). Subsequently, the phantom was exposed at the different simulated breast thicknesses using the gridless module in combination with the parameters automatically selected for the grid module. This was followed by a series of phantom mammograms obtained with the experimental setup reversed. The 16 mammograms were evaluated by 3 readers and the results compared considering breast thickness, radiation dose, and quality. The gridless module was used for preoperative labeling in 16 patients for comparison of mammograms obtained with and without a grid. RESULTS: For the same entrance dose used in routine mammography, digital mammography without grid is superior to digital mammography with grid when performed on simulated thin breasts (Plexiglas less than 3 cm), with no difference found when performed on simulated large breasts. The advantages of gridless mammography are more pronounced at a markedly reduced entrance dose (identical parenchymal dose without and with grid using the dose automatically selected for the gridless module). This tendency is confirmed by the initial clinical comparison. CONCLUSION: Gridless digital full-field mammography has the potential to reduce the dose further, in addition to already known mechanisms of dose reduction. However, the gridless system must be adjusted (markedly higher "switch-off dose" at the detector) to achieve an overall dose reduction since gridless mammography is inferior to grid mammography for identical doses at the detector plane.

Artifacts↗

[Sacroiliitis in children with spondyloarthropathy: therapeutic effect of CT-Guided intra-articular corticosteroid injection].

PURPOSE: The prospective investigation of the therapeutic effect of CT-guided intra-articular corticosteroid injection into inflammatory sacroiliac (SI) joints compared to conventional treatment with nonsteroidal anti-inflammatory drugs (NSAIDS) in children with juvenile spondyloarthropathy (jSpA) and the determination of the role of dynamic magnetic resonance imaging (MRI) in establishing the indication and monitoring the therapy. MATERIALS AND METHODS: The study comprises 89 children with known jSpA who were diagnosed by MRI to have a unilateral or bilateral sacroiliitis. Therapy with NSAIDS was initiated or continued in all 89 patients. Four weeks after the diagnostic MRI, two groups were distinguished according to the clinical response to NSAIDS, with group 1 consisting of 33 responders and group 2 of 56 non-responders. The patients of group 2 were treated with CT-guided intra-articular corticosteroid injection (low-dose injection) while the therapy with NSAIDS was continued. A total of 83 SI joints were punctured without complications, 27 bilaterally and 29 unilaterally. The indication for the intervention was based on inflammatory activity as determined by MRI. The therapy was monitored by clinical follow-up every 8 to 12 weeks over a period of 20 months. Follow-up by dynamic MRI was performed in all 56 children of group 2 and in 15 of the 33 children of group 1 within 8 +/- 4 months of the initial examination. RESULTS: A total of 87.5% of the children in group 2 showed a statistically significant decrease in their subjective complaints from 6.9 +/- 3.4 to 1.8 +/- 1.7 (p < 0.05) as measured on a visual analog scale (VAS from 0 to 10). Improvement was seen as early as 1.5 +/- 1.0 weeks after the intervention and lasted for a mean of 12 +/- 6 months. The children in group 1 already showed similar improvement of the VAS from 6.8 +/- 3.2 to 1.5 +/- 1.4 (p < 0.05) during the initial four weeks of NSAIDS therapy, with the improvement lasting for the 20-month observation period. The follow-up dynamic MRI (0.1 mmol/kg body weight) during therapy showed a statistically significant lower contrast-enhancement in both groups (group 1: 117 +/- 43 % versus 38 +/- 24 %, p < 0.05; group 2: 127 +/- 59 % versus 38 +/- 22 %, p < 0.05). One third of the patients of group 2 showed progression of joint destruction despite absence of subjective complaints. CONCLUSION: CT-guided intra-articular corticosteroid injection has proven an effective, symptomatic, and uncomplicated therapy of acute sacroiliitis in patients with jSpA. Dynamic MRI has a role in establishing the indication for intervention but its role for any follow-up is restricted to cases with inconclusive clinical response.

Adolescent↗

[Visualization of microcalcifications on mammographies obtained by digital full-field mammography in comparison to conventional film-screen mammography].

PURPOSE: To evaluate the visualization of microcalcifications on mammographies obtained by full-field digital mammography (FFDM) in comparison to conventional film-screen mammography (FSM). MATERIAL AND METHODS: Forty-seven digital and film-screen mammographies depicting histologically proven lesions (27 benign, 20 malignant) were assessed by 4 readers. The images obtained with the different systems were comparable in terms of positioning. Maximum time interval between film-screen mammography and digital mammography was three months. Using a questionnaire, the readers evaluated the number of microcalcifications and their subjective conspicuity for FFDM (Senographe 2000D, GE Medical Systems, Milwaukee, USA) and FSM. A 7-point scale based on the BIRADS classification was used to characterize the calcifications by means of ROC analysis. RESULTS: No statistically significant differences were seen between the two types of mammography among the readers in assessing the number of microcalcifications. The subjective conspicuity of microcalcifications was found to be significantly better for digital mammographies. The diagnosis assigned by the readers did not show significant differences between the two systems. CONCLUSION: Although the subjective conspicuity of microcalcifications was found to be significantly better on digital mammography compared to film-screen mammography, there was no significant advantage of digital mammography resulting from the higher contrast resolution nor a disadvantage in terms of characterization of microcalcifications resulting from the lower spacial resolution. The advantages of digital mammography (e. g. CAD-systems, archiving, dose reduction) can be used without a loss of diagnostic quality.

Breast Diseases↗

Treating type 2 diabetes in renal insufficiency: the role of pioglitazone.

The advent of new antidiabetic drugs is of special importance for diabetic patients with already impaired renal function since renal insufficiency is a relative or absolute contraindication for several of the established hypoglycemic drugs. Pioglitazone is a novel oral hypoglycemic agent that increases insulin responsiveness in target tissues. Pioglitazone and its active metabolites are excreted mainly via the liver. Drug exposure remains almost constant across a wide range of renal function since there is no accumulation of the drug or its active metabolites during repeated dosing in renal insufficiency. The pharmacokinetic properties of pioglitazone are ideally suited for patients with renal insufficiency. Although there are possible side effects (mainly fluid retention and weight gain and--very rarely--hepatotoxicity). Pioglitazone has a good safety profile in diabetic patients with impaired renal function.

Area Under Curve↗

[Digital full field mammography after breast augmentation].

PURPOSE: The use of digital full field mammography for imaging augmented breasts. METHODS: Images of a sponge, as a tissue equivalent, partly covered with one of three different implants (silicone, silicone/saline, saline) were obtained using digital and film-screen technique. The visualisation of the sponge structure covered by the implant and next to the implant was evaluated by two radiologists. Results were compared to clinical results from 35 patients with implants. RESULTS: Two images with different parameter settings have to be obtained to visualize the covered sponge structure and the structure around the implant with film-screen technique. Digital mammography allows assessment of both areas using one image at different window settings. The assessability of covered structures depends on the type of implant. These results are in keeping with our clinical experiences. CONCLUSION: Digital mammography allows equal or better assessment of covered and non-covered tissue in augmented breasts without the need for additional exposures.

Breast Diseases↗

[Comparing the visualization of microcalcifications with direct magnification in digital full-field mammography vs. film-screen mammography].

PURPOSE: To evaluate the conspicuity of microcalcifications in magnified mammographic views of preparations obtained with full field digital mammography (FFDM), film-screen mammography (FSM), and the DIMA technique. MATERIAL AND METHODS: Twelve preparations were examined by FFDM and FSM using 1.8 x magnification and DIMA using 7 x magnification. Parameter settings were identical for all three techniques. The number of visible microcalcifications was then determined for each modality by three radiologists. As far as possible, all preparations were X-rayed at 22 kV and 10 mAS. RESULTS: Altogether 9705 calcifications were counted (DIMA: 1609/1542/1534; FFDM: 1020/753/881; FSM: 901/643/822). The total number of microcalcifications identified with the DIMA technique was 4685 as compared to 2654 with FFDM and 2366 with FSM. The calcifications counted with FFDM and FSM thus corresponded to 56.6 % and 50.5 %, respectively, of those identified with DIMA. The differences between the groups were statistically significant (F-Test, p < 0.05). CONCLUSION: Significantly more calcifications are identified when magnified mammographic views of preparations containing microcalcifications are obtained with the DIMA technique compared to FFDM or FSM. FFDM depicts markedly more calcifications than FSM. This means one should increase spatial resolution. Digital mammography offers the potential for improved visualization of microcalcifications with advanced applications.

Breast Neoplasms↗

[Improved diagnosis through digital mammography with the assistance of computer algorithms].

OBJECTIVE: The aim of this survey was to determine improved diagnostics through digital mammography with assistance of computer algorithms and new investigation techniques. MATERIAL AND METHODS: In general, the presented procedures are practicable with all digital mammography procedures. In our clinic the largest clinical experience exists with the only FDA certified full field mammography device Senograph 2000D (GE Medical Systems). RESULTS: First results from initial studies are shown, which are to evaluate the new procedures. The so-called post processing with visualization of microcalcifications, computer-assisted diagnosis, tomosynthesis, energy subtraction, contrast media in mammography and teleradiology are considered in particular. CONCLUSION: Digital mammography represents a promising procedure, opening new possibilities for improved diagnostic in mammography.

Algorithms↗

Hypokalemic nephropathy after pelvic pouch procedure and protective loop ileostomy.

Proctocolectomy with ileal pouch-anal anastomosis and temporary ileostomy has been established as a curative operation in severe ulcerative colitis during the last 2 decades. Electrolyte imbalances during the first postoperative weeks until ileostomy closure have been reported previously. Here we report about a 70-year-old male patient with a 38 year-history of severe ulcerative colitis who developed slowly progressive renal failure after proctocolectomy with ileal pouch-anal anastomosis and temporary ileostomy. He was referred to our centre with a serum creatinine of 818 micromol/L, hypokalemia of 2.83 mmol/L and metabolic alkalosis as a patient with suspected end-stage renal disease in order to perform shunt surgery and start chronic hemodialysis. However, hypokalemia and metabolic alkalosis are not typical for end-stage renal disease, and renal biopsy showed typical signs of hypokalemic nephropathy. Our patient almost completely recovered after ileostomy closure. This case clearly shows that temporary ileostomy in patients who underwent proctocolectomy, e. g. for ulcerative colitis, is associated with a risk of hypokalemic nephropathy. The appropriate and definite therapy is a surgical one, i. e. ileostomy closure. Monitoring metabolic changes after proctocolectomy and ileostomy, especially during the defunctionalized stage when temporary ileostomy is still present, is essential.

Adult↗

[Initial clinical experiences with digital full-field mammography].

OBJECTIVE: Digital full-field mammography has been used at the Department of Radiology of Charité Medical Center in Berlin since June 1999. This study compares the new digital technique with conventional mammography including a survey of its value in breast imaging and an outline of future prospects. MATERIAL AND METHODS: More than 1,000 of a total of over 5,000 mammographies performed between June 1999 and April 2000 have been obtained using the digital full-field mammography system Senographe 2000D (GE Medical Systems). The digital mammograms were compared with previous conventional films and conventional mammographies performed during the same period (Philips UC Diagnost, Senographe DMRplus). RESULTS: Digital mammographies were equal to conventional ones in all cases and seemed to be superior in detecting microcalcifications in dense glandular tissue. Adequate assessment was possible despite the lower spatial resolution compared to conventional mammography. Additional magnified images were obtained with both techniques for differentiating microcalcifications. CONCLUSIONS: Digital full-field mammography appears to be at least equal to the conventional technique and even superior in some respects. In our experience, the lower spatial resolution of digital mammography has no major disadvantages. The digital system provides new options for electronic storage of mammograms, telemammography, and computer-aided diagnosis.

Breast Neoplasms↗

[Intraoperative digital radiography for diagnosis of nonpalpable breast lesions].

PURPOSE: A procedure for performing intraoperative digital radiography of diagnostic breast specimens directly in the operating suite with teleradiologic assessment by a radiologist is presented. The efficiency of this procedure is compared with that of conventional magnification mammography performed in the radiology department. MATERIAL AND METHODS: Thirty-six specimen radiographs obtained by conventional magnification mammography were compared with 38 intraoperative digital magnification radiographs (DIMA Soft P42 prototype, Feinfocus Inc., Garbsen). The radiographs were assessed for lesion conspicuity and time savings for the surgeon, anesthesiologist, and radiologist. RESULTS: The new procedure identified all 38 labeled pathological lesions, and the conventional technique likewise had a detection rate of 100% (36/36). The new technique resulted in considerable time savings for the surgeon and the radiologist. The duration of surgery was shorter and the time interval from removal of the specimen to reporting of the results was reduced from about 23 min to about 13 min. A single radiograph was sufficient for complete visualization of the specimen in all cases. CONCLUSION: Digital intraoperative specimen radiography considerably reduces the time of surgery depending on the local conditions and is highly accurate in locating a suspicious area within the tissue.

Breast Neoplasms↗