Evaluation of a wavelet-based computer-assisted detection system for identifying microcalcifications in digital full-field mammography.

Abstract

PURPOSE: To evaluate a new wavelet-based computer-assisted detection (CAD) system for detecting and enhancing microcalcifications. MATERIAL AND METHODS: A total of 280 mammograms acquired by full-field digital mammography (Senographe 2000D; G.E. Medical Systems Milwaukee, Wisc., USA) were analyzed with and without a new wavelet-based CAD system for detecting and enhancing microcalcifications. The mammograms comprised roughly equal numbers of cases from each of the BIRADS (Breast Imaging, Reporting and Data System, according to the American College of Roentgenology) categories 1-5. Histologic confirmation was available for all of the 180 cases assigned BIRADS categories 3-5. Four readers interpreted all 280 images for suspicious microcalcifications using a scale of 1-5. The readers alternately assessed 5 images with and 5 without CAD. In a second reading immediately following the first, the readers had to reassess the 280 mammograms. The images that had already been interpreted without CAD were now presented with CAD and vice versa. The images were interpreted as soft copies on a diagnostic mammography workstation (Image Diagnost GmbH, Neufahrn/Munich, Germany). All images interpreted with CAD were presented with enhancement of microcalcifications by wavelet algorithms and prompting of microcalcifications. ROC (receiver operating characteristic) analyses were performed, and image interpretation time with and without CAD was measured. RESULTS: The overall time for interpretation required by all 4 readers together was 483 min with CAD compared to 580 min without CAD. ROC analysis revealed no significant advantage of CAD for the individual readers. Readers 3 (0.811/0.817) and 4 (0.799/0.843) had a slightly improved AUC (area under the curve) with CAD. Readers 1 and 2 had a slightly lower AUC with CAD (0.832 versus 0.861 and 0.818 versus 0.849). CONCLUSION: The CAD system significantly (P<0.05, t test) speeded up image interpretation with respect to the identification of microcalcifications, while the diagnostic quality remained almost identical under the study conditions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F Diekmann, S Diekmann, M Bollow, K G Hermann, K Richter, P Heinlein, W Schneider, B Hamm. 2004. Evaluation of a wavelet-based computer-assisted detection system for identifying microcalcifications in digital full-field mammography.. https://doi.org/10.1080/02841850410003770

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of 4 MV photon surface dose among Varian, Siemens, and Elekta linear accelerators for tangential breast treatment: a phantom study.

PURPOSE: We have compared the differences in a 4-MV photon surface dose among Varian, Siemens, and Elekta linear accelerators (linacs) with wedges for tangential breast treatment. MATERIALS AND METHODS: The wedge factor and the surface dose were measured using a solid water phantom and an ion chamber for each linear accelerator with various field sizes and wedge angles. A tangential treatment plan was applied to an elliptical hollow cylinder water phantom with a radiochromic film placed thereon. A dose was delivered to a simulated target in the phantom, and the resulting dose distribution was analyzed using a film scanner. RESULTS: Varian's wedges resulted in the highest wedge factors, ranging from 0.37 to 0.75 depending on the wedge angles. Varian's wedges led to the highest normalized skin doses, ranging between 0.40 and 0.73 depending on the wedge angles and field sizes. In the cylinder phantom test with two tangential beams, the Varian linac provided a nearly 20% higher maximum dose than the Siemens and Elekta linacs. CONCLUSION: The Varian linac resulted in the highest surface doses, and the Elekta linac led to the lowest for nearly all the measurement conditions we employed, including open beams.

Breast Diseases↗

[Is the application of CAD useful for radiologists for passing the official tests required for outpatient breast imaging?].

PURPOSE: To analyze whether currently available CAD systems meet the diagnostic requirements for passing screening tests (first reader CAD) and to analyze whether the additional usage of CAD systems provides significant support for the diagnosing radiologist on the basis of official screening test cases (second reading by CAD). MATERIAL AND METHODS: 200 images of 100 mammographies of 50 patients of an official screening test case collection were analyzed double-blind with and without CAD printouts (iCAD, USA ) by three radiologists: one experienced in breast analysis and CAD application, one experienced in mammography analysis but inexperienced in CAD usage, one with minimal experience with breast analysis and CAD application. All radiologists measured the largest diameter of any malignant mass. The mean value of these calculations was correlated to the largest diameter given by CAD prompts. RESULTS: The mean sensitivity and specificity increased slightly as a result of the additional usage of CAD (1 and 0.6 %, resp.). Both values are not statistically significant. The highest effect was measured for the radiologist with CAD experience, while no effect was measured for the inexperienced radiologist. CAD met the sensitivity requirements but not the specificity criteria (96 and 20.3 %, resp.). The sizes given by CAD prompts corresponded significantly with the real sizes (r = 0.45, p < 0.05). CONCLUSION: A statistically significant effect of the use of CAD could not been detected dependent on the radiological experience or the CAD experience. The effect of CAD on radiologists is still subtle despite the highly sensitive CAD performance due to the high number of false positive prompts and thus does not reach statistical significance. Sizes given by CAD prompts correlate significantly with the real sizes of malignant lesions.

Breast Diseases↗