PubMed Health⌕ Search

Biomedical subjects

F García-Godoy

Publications and source records attributed to F García-Godoy.

At least 91 records · Page 5Linked to original sources

Digital radiology and image analysis for approximal caries diagnosis.

The aim of this study was to determine if radiology combined with digital reception and image analysis, radiovisiography (RVG), is effective in the early diagnosis of simulated approximal carious lesions. An experimental lesion similar to the one produced by caries was made in 39 permanent molars and premolars. Radiographic images of these lesions were obtained under standardized conditions using RVG. The image obtained was magnified 700 times and the densities of the lesion, the enamel, the dentin, and the pulp were measured using an image analysis program (Visualdent). The results showed statistically significant differences between the density of the produced lesions and that of healthy enamel. This measurement was independent of the differing thickness of the approximal enamel surface in molars and premolars. These results indicated the potential usefulness of the system tested in the diagnosis of incipient approximal caries.

Dental Caries↗

Evaluation of different methods for cleaning and preparing occlusal fissures.

The effectiveness of different methods for cleaning and preparing occlusal fissures before placing sealants was evaluated. Extracted mandibular molars received such treatments as brushing, pumicing, bur preparing, and air abrasion before application of fissure sealants. FluroShield fissure sealant was then applied to the occlusal fissures. Specimens were subjected to thermo-cycling and then immersed in a 10% solution of methylene blue, and finally sectioned. The sections were examined and photographed in a stereomicroscope, and the dye penetration was recorded using a scoring system. The results indicated that only the control (brushing with a dry brush) and the pumicing groups demonstrated dye penetration to the base of the sealant. Teeth prepared with the #1/4 round bur and air abrasion demonstrated a better seal in evaluated fissures. For this study, those three groups (occlusal fissures prepared with the #1/4 round bur and two air abrasion methods), demonstrated significantly better sealing (P < 0.01) than the control group and the other groups tested.

Air Abrasion, Dental↗

Multiple eruption cysts: report of case.

The eruption cyst is a type of soft tissue cyst associated with erupting teeth. It occurs usually in childhood, and they appear to be more prevalent in the maxillary arch. This paper presents a case report of a fifteen-month-old child who presented six eruption cysts simultaneously and their treatment.

Dentigerous Cyst↗

Effect of 1.23 percent APF gel on fluoride-releasing restorative materials.

This study evaluated the effect of a 1.23 percent APF gel on the surface morphological characteristics and surface roughness of one high-viscosity (Fuji IX GP), three polyacid-modified resin-based composites (Dyract AP, F2000 and Compoglass F) (PMRC), and two resin-modified glass-ionomer cements (Vitremer and Fuji II LC). A microfilled nonfluoridated resin-based composite (Silux Plus) was used as a control. All materials were handled according to the manufacturers' instructions. The fluoride gel used in the study was a 1.23 percent acidulated phosphate fluoride gel (APF) (Nupro APF). The specimens were repeatedly exposed to the APF gel with cotton applicators for a period that simulated the equivalent of 4 yrs (1 min/6 mo) under prophylactic fluoride treatment. Average surface roughness (Ra) of the control and treated specimens was measured. Three separate Ra measurements along the direction of rotation of the finishing and perpendicular to the finishing direction and edge of the mold were made for each specimen surface. In each group, specimens with Ra closest to the mean were removed from the molds, sputter-coated with gold and examined using a scanning electron microscope. The results showed that all tested materials, except Vitremer, displayed increased surface roughness values following APF treatment. However, this was not statistically significant for Compoglass F, Vitremer and Fuji II LC. Among PMRC materials, F2000 displayed the highest Ra average value, although the differences between F2000 and Dyract AP and of Compoglass F and Dyract AP was not statistically significant. Comparisons of the Ra values between Silux Plus and the other test materials revealed statistically significant differences except for Dyract AP and Compoglass F. No statistically significant difference was found between the Ra values of Vitremer and Fuji II LC following APF treatment. Among all groups, Fuji IX GP displayed the highest surface roughness.

Acidulated Phosphate Fluoride↗

Resorption of a calcium hydroxide/iodoform paste (Vitapex) in root canal therapy for primary teeth: a case report.

This case report presents a clinical and radiographic follow-up (38 months) of pulpectomy treatment performed on maxillary primary anterior teeth using Vitapex. Vitapex was resorbed extraradicularly and intraradicularly without apparent ill effect, and proved to be clinically and radiographically successful. The present case report illustrates that even if the paste resorbs within the canals, the clinical and radiographical outcome is excellent. A longer follow-up is recommended to evaluate if there is any effect on the permanent succedaneous tooth.

Absorption↗

In vivo rehardening of enamel eroded by a cola drink.

There are many concerns about the erosive effects of acidic beverages. In this study, the effects of Pepsi-Cola (pH 2.41) on bovine enamel and the rehardening effect resulting from intraoral exposure of the teeth were determined by microhardness testing (Vicker's Hardness Number). Bovine enamel specimens (VHN 380.00 +/- 12.74) were immersed in 100 ml of Pepsi-Cola for five minutes and subsequently exposed to human intraoral environment through the use of a removable resin plate. Microhardness testing was performed on specimens after one hour, twenty-four hours and forty-eight hours of exposure to an intraoral environment. The microhardness value was significantly (p < 0.05) reduced by the cola beverage (VHN 262.13 +/- 20.34), and significantly (p < 0.05) increased after intraoral exposure for one hour (VHN 299.75 +/- 26.86) and twenty-four hours (VHN 328.00 +/- 18.70). The difference in the microhardness between the twenty-four-hour group and the forty-eight-hour group (VHN 333.50 +/- 15.13) was not significant (p > 0.05). The microhardness value of the forty-eight-hour group was significantly less than the values recorded during the initial pre-study measurements p < 0.05).

Acids↗

Clinical evaluation of glass ionomers used as fissure sealants: twenty-four-month results.

This study evaluated the twenty-four-month retention and effectiveness in dental caries prevention, of Vitremer and Ketac-Bond glass ionomers used as occlusal sealants. The initial sample consisted of 200 school children ages six to eight years whose permanent first molars were sound. The children were divided into two experimental groups (group 1 Vitremer; group 2 Ketac-Bond) and a control group (group 3 unsealed molars). Statistical analysis (Mann-Whitney test) revealed that there were statistically significant differences between the retention levels of the experimental groups A and B in the three evaluation periods (six-, twelve- and twenty-four-month) with Vitremer showing superior results. As to caries incidence, there was a statistically significant difference (chi 2 test) between the experimental groups (A and B) and the control group indicating that glass ionomers are effective for prevention of caries in the occlusal surfaces. Two independent variables were correlated with the presence of caries or that of a restored tooth after twenty-four months (odds ratio) revealing that children who presented white spots (WS) had a probability of presenting caries or restorations that was 5.0, 3.07 and 1.93 times greater at six, twelve, and twenty-four months, respectively than that of children who did not show WS in the experimental groups A and B and in the control group, respectively. The variable represented by the "dmf" index showed a statistically significant correlation (chi 2 test) in the control group, in which there was a 3.26 times greater probability of children presenting a "dmf" index equal to or greater than 1 in the development of caries or who presented a restored tooth in relation to those who did not have a history of caries ("dmf" = 0).

Cariostatic Agents↗

Effect of eccentric load cycling on microleakage of Class V flowable and packable composite resin restorations.

Class V composite restorations are subject to the stresses that induce non-carious cervical lesions. This study evaluated the effect of eccentric oblique load on microleakage of restorations. Class V cavities were randomly prepared on the buccal surfaces of 40 recently extracted premolars and restored with composite resin according to manufacturers' directions. Teeth were randomly assigned to one of four treatment groups with 10 teeth per group: (1) flowable resin (Revolution) without load cycling; (2) packable resin (Prodigy Condensable) without load cycling; (3) flowable resin with load cycling (200,000 cycles) and (4) packable resin with load cycling (200,000 cycles). All teeth were then immersed in 2% methylene blue solution for 24 hours after thermocycling (500 cycles). Dye penetration was measured (scores 0-3). The results indicated that adding load cycling significantly increased microleakage (p < 0.05). No significant differences in microleakage were observed for flowable resin vs packable resin. Gingival margins had significantly more microleakage (p < 0.05) than occlusal margins.

Analysis of Variance↗

Black stain and dental caries in schoolchildren in Potenza, Italy.

This study examined the correlation between dark pigmented dental plaque (black stain) and caries. Black stain was observed in 67 of 1086 schoolchildren (from 6-12 years old). The mean DMF-T was 0.49 = 1.05 for children with black stain and 0.97 = 1.40 for children with black without black stain (p<0.05). The results suggest an association between black stain and a decreased caries experience at least in the permanent dentition. Further studies are necessary to examine the etiology and whether or not black stain can protect against caries.

Child↗

Herpetic gingivostomatitis and teething difficulty in infants.

This investigation was conducted to determine whether primary herpetic gingivostomatitis may be responsible for those signs and symptoms commonly attributed to teething in infants. Twenty infants presenting with a parental diagnosis which indicated teething difficulty were included in this study (Group A). Twenty infants who were in no distress served as controls (Group B). Oral swab samples were obtained from each infant and then processed to ascertain the presence of herpes simplex virus (HSV). Each infant's temperature and oral status also were recorded. Nine subjects in Group A (45%) were positive for HSV. Of these nine, seven had elevated temperatures (less than 100 degrees F) and all had signs of oral infection of varying severity. Of the 11 subjects in Group A who were negative for HSV, five had elevated temperatures, but none showed evidence of oral infection. Subjects in Group B were all negative for HSV, elevated temperature, and signs of oral infection. Results of this study suggest that oral HSV infection should be included in the differential diagnosis of infants presenting with a parental diagnosis of teething difficulty.

Child, Preschool↗

Comparison of different DIAGNOdent cut-off limits for in vivo detection of occlusal caries.

This study tested recently recommended cut-off limits for the laser fluorescence based device DIAGNOdent (KaVo) for detection of occlusal caries. Two hundred and forty-eight permanent molars from 94 patients (mean age 19.2 years) of a general dental practice were included. After professional tooth cleaning, the teeth were examined visually and by the laser fluorescence method. The extent of occlusal lesions (gold standard) was determined after minimal operative intervention. Upon fissure opening, 24 teeth had enamel caries and 224 teeth revealed dentin caries, of which 58 and 166, respectively, were up to or beyond half the dentin. The optimal cut-off limits based on the highest kappa-values (0.51 and 0.54) were > 18 for superficial dentinal caries (D3) and > 37 for deep dentinal caries (D4). The comparison with DIAGNOdent cut-offs given by the manufacturer (n = 4) and those based on clinical trials with in vivo validation (n = 4) and in vitro studies with histological validation (n = 3) revealed a considerable variation in performance. Recommended cut-offs between 17 and 21 for superficial dentin lesions were in the same order of magnitude (0.48-0.51). On the D4 level, only the manufacturer's cut-off of > 34 achieved the best performance (0.51). According to the highest kappa-values and the area under the ROC curves (D3: A(z) = 0.903; D4: A(z) = 0.830), the agreement between the extent of validated caries and laser fluorescence value is still unsatisfactory.

Adult↗

Composite resin bond strength after enamel bleaching.

This study evaluated the effect of enamel bleaching with a commercial product on the sheer bond strength of a composite resin. A total of 45 human extracted permanent molars were used. A flat enamel surface was obtained with 600-grit SiC paper. The teeth were then randomly distributed into three groups of 15 teeth each: Group 1: Enamel etching with 37% phosphoric acid gel (Coe) for 60 seconds, placement of an unfilled resin (Coe) thinly applied with a brush and a composite resin (Occlusin); Group 2: Enamel bleaching (Rembrandt Lighten Bleaching Gel, Den-Mat) for one hour, etching for 60 seconds and placement of unfilled and composite resins. Group 3: Enamel bleaching for 24 hours, etching for 60 seconds, and placement of unfilled and composite resins. A nylon ring over the etched enamel retained the composite resin. The teeth were thermocycled (X100) and sheared with a knife-edged blade in an Instron machine running at a cross-head speed of 1 mm/min. The results in MPa were: Group 1: 12.86 +/- 4.83, Group 2: 12.33 +/- 2.95, and Group 3: 7.67 +/- 1.98. An ANOVA revealed that Groups 1 and 2 were significantly different from Group 3 (P < 0.001). Fracture within the enamel occurred in 53% in Group 1, 33% in Group 2, and 0% in Group 3. The study reveals that the shear bond strength of composite resins is significantly reduced after enamel bleaching for 24 hours.

Analysis of Variance↗

Enamel and dentin bond strength and bonding mechanism to dentin of Gluma CPS to primary teeth.

This study evaluated the shear bond strength to enamel and dentin and bonding mechanism to dentin of Gluma CPS bonding system to primary teeth enamel and dentin. Pekafill hybrid composite was used. Ten specimens were immersed in deionized water at 37 degrees C for twenty-four hours and ten other specimens were subjected to a thermocycling procedure (2000 cycles between 5 degrees and 55 degrees C, dwell time fifteen seconds). After water storage or thermocycling, the bonded cylinders were sheared and the bond strength calculated. After debonding, the failure sites of all samples were evaluated microscopically. The data were analyzed with an ANOVA and Student-Newman-Keuls test. In ten other primary molars, the buccal surfaces were ground flat on wet SiC papers to expose peripheral dentin. Cylindrical buttjoint cavities were prepared with a cylindrical diamond bur. The cavities were treated with Gluma CPS and filled with pekafill as described above. After fifteen-minute water storage, filling excess was removed and marginal integrity and bonding mechanism of five restorations was examined with a light microscope. Five other restorations were evaluated after storage in water at 37 degrees C for twenty-four hours. Maximal gap widths and hybrid layer thickness were determined. The results showed that thermocycling did not affect the shear bond strength to enamel or dentin. There was a statistically significant difference (p < 0.05) between the shear bond strength values obtained in enamel and dentin. The maximal gap width was not significantly different between specimens that were stored in water for fifteen minutes or twenty-four hours. The average hybrid layer thickness was 11.7 +/- 1.1 micrograms. All specimens revealed a resin cohesive failure very close to enamel or dentin surface. The etch patterns produced on the abraded enamel surface were uniform and deeper as compared to the sample that was pumiced. This was also confirmed in the epoxy replicas.

Acid Etching, Dental↗

A comparison of three resin bonding agents to primary tooth dentin.

This study determined the shear bond strength of resin composites to primary dentin using three dentin adhesives and the presence or absence of a hybrid zone. The buccal and lingual surfaces of 40 recently extracted noncarious primary teeth were ground flat with SiC paper ending with the 600 grit. The teeth were divided at randomly into eight groups of five teeth (10 surfaces) each: 1) Unetched dentin, dry dentin, All-Bond 2/Bis-Fil P; 2) Unetched dentin, moist dentin, All-Bond 2/Bis-Fil P; 3) Dentin etched for 15 sec with 10% phosphoric acid, dry dentin, All-Bond 2/Bis-Fil P; 4) Dentin etched for 15 sec with 10% phosphoric acid, moist dentin, All-Bond 2/Bis-Fil P; 5) Dentin etched with 10% maleic acid for 15 sec, dry dentin, Scotchbond Multi-Purpose/Z100; 6) Dentin etched with 10% maleic acid for 15 sec, moist dentin, Scotchbond Multi-Purpose/Z100; 7) Dentin etched with 10 citric acid/3% ferric chloride, dry dentin, Amalgambond Plus/Z100; 8) Dentin etched with 10 citric acid/3% ferric chloride, moist dentin, Amalgambond Plus/Z100. All teeth were thermocycled 1000x (5 and 55 degrees C, 30-sec dwell time), and shear bond strength testing was conducted using an Instron (crosshead speed 0.5 mm/min). Failure sites after debonding were examined with the SEM. For each group, one additional tooth was used to prepare two class V cavities (one facial and one lingual) restored according to the specification in each group, sectioned buccolingually and examined with the SEM. The results, in MPa, were: 1) 12.55 +/- 5.97; 2) 10.41 +/- 6.16; 3) 9.94 +/- 7.26; 4) 12.25 +/- 4.70; 5) 13.02 +/- 8.01; 6) 16.51 +/- 8.62; 7) 12.51 +/- 8.95; 8) 17.93 +/- 6.44. ANOVA and Student-Newman-Keuls tests showed no statistically significant differences. SEM evaluation showed that the smear layer was removed in all groups exposing primary dentin tubules infiltrated by resin. A resin-reinforced hybrid layer was readily seen in all specimens.

Acid Etching, Dental↗

Surface hardness of a resin composite cured with a transparent cone.

The purpose of this study was to evaluate the surface hardness of a resin composite (TPH) polymerized with and without the use of a transparent light-curing cone. Twenty composite blocks were made on a Teflon mold with cylindrical holes of 3 mm depth and 6 mm radius, and were light cured following different procedures. Group 1: Ten samples were pressed with a glass slide and light cured for two 40-sec exposures without the plastic cone; Group 2: Ten samples were light cured using the transparent plastic cone which was pressed down into the composite until the tip was 1 mm from the floor of the cylindrical Teflon mold. The curing light was activated for 40 sec. The cone was then removed and the remaining part of the mold was filled in one portion, pressed with a glass slide, and light cured for 40 sec. After curing, the samples were placed in distilled water for 48 hr. The hardness of the samples was then measured with a Rockwell Hardness Tester at three different points on each composite block; therefore, 30 measurements per group were taken. The data were statistically analyzed using an unpaired Student's t test. The results revealed that the resin composite cured with the transparent plastic cone had a statistically significant higher surface hardness value (P < 0.0001) than the group cured without the cone.

Composite Resins↗