A femtogram resolution mass sensor platform, based on SOI electrostatically driven resonant cantilever. Part I: electromechanical model and parameter extraction.

A microcantilever based platform for mass detection in the femtogram range has been integrated in the doped top silicon layer of a SOI substrate. The on-plane fundamental resonance mode of the cantilever is excited electrostatically and detected capacitively by means of two parallel placed electrodes in a two port configuration. An electromechanical model of the cantilever-electrodes transducer and its implementation in a SPICE environment are presented. The model takes into account non-linearities from variable cantilever-electrode gap, fringing field contributions and real deflection shape of the cantilever for the calculation of the driving electrostatic force. A fitting of the model to the measured S(21) transmitted power frequency response is performed to extract the characteristic sensor parameters as Young modulus, Q factor, electrical parasitics and mass responsivity.

Journal Article↗

A femtogram resolution mass sensor platform based on SOI electrostatically driven resonant cantilever. Part II: sensor calibration and glycerine evaporation rate measurement.

This paper presents mass measurements of glycerine beads performed by means of laterally resonant micro-cantilevers. The transducer architecture is based on a resonant cantilever electrostatically coupled by two parallel placed electrodes. Previous to glycerine measurements, a calibration of the mass sensor has been performed by measuring a standard mass based on latex spheres. From these measurements, a value of the mass responsivity is deduced. In addition, a study of the transducer phase noise has been carried out in order to determine the minimum detectable mass. Mass measurements experiments have been performed by detecting the change on the resonance frequency of the on-plane cantilever resonant mode, produced by locally deposited mass. Additionally, the mass losses detected on the calibrated transducer after glycerine drop deposition allowed determining its evaporation rate.

Journal Article↗

On the electromechanical modelling of a resonating nano-cantilever-based transducer.

An electromechanical model for a transducer based on a lateral resonating cantilever is described. The on-plane vibrations of the cantilever are excited electrostatically by applying DC and AC voltages from a driver electrode placed closely parallel to the cantilever. The model predicts the static deflection and the frequency response of the oscillation amplitude for different voltage polarization conditions. For the electrostatic force calculation the model takes into account the real deflection shape of the cantilever and the contribution to the cantilever-driver capacitance of the fringing field. Both the static and dynamic predictions have been validated experimentally by measuring the deflection of the cantilever by means of an optical microscope.

Journal Article↗

Thermal AFM: a thermopile case study.

In this work, an atomic force microscope (AFM) with an integrated thermal sensor has been used to obtain the local spatial distribution of temperatures in a micromachined thermopile with submicron resolution. In this communication, we will show how the dimensional, structural and functional characteristics of a thermopile suits well with the requirements for AFM thermal imaging, and how a deeper insight of the thermopile operation can be gained with the aid of these advanced scanning probe-based tools.

Diagnostic Imaging↗

Comparison of highly efficient absorbing boundary conditions for the beam propagation method.

Numerical experiments using the paraxial finite-difference beam propagation method have been performed with the following boundary conditions: perfectly matched layer, Higdon absorbing boundary conditions, complementary operators method, and extended complementary operators method. We have shown that Higdon operators must be modified for the paraxial wave equation to take into account the spectrum of incident rays on the boundaries of the computational domain. Reflection coefficients, accuracy, numerical dissipation/ gain, memory requirements, and time computation are compared and discussed for these absorbing techniques.

Journal Article↗

Characterization of antiresonant reflecting optical waveguide devices by scanning near-field optical microscopy.

Silicon-based antiresonant reflecting optical waveguide (ARROW) devices were studied by means of a scanning near-field optical microscope. Various structures such as a Y junction of a Mach-Zehnder interferometer and a directional optical coupler were characterized, showing the propagation of the light inside the devices simultaneously with the topography. Scattering on the splitting point of the Y junction was shown, as well as a partial coupling of the light between the two branches of the coupler. Measurements on the decay length of the evanescent field were also performed to study the use of the ARROW waveguide for sensor purposes.

Journal Article↗

Atomic force microscope characterization of a resonating nanocantilever.

An atomic force microscope (AFM) is used as a nanometer-scale resolution tool for the characterization of the electromechanical behaviour of a resonant cantilever-based mass sensor. The cantilever is actuated electrostatically by applying DC and AC voltages from a driver electrode placed closely parallel to the cantilever. In order to minimize the interaction between AFM probe and the resonating transducer cantilever, the AFM is operated in a dynamic non-contact mode, using oscillation amplitudes corresponding to a low force regime. The dependence of the static cantilever deflection on DC voltage and of the oscillation amplitude on the frequency of the AC voltage is measured by this technique and the results are fitted by a simple non-linear electromechanical model.

Journal Article↗

AFM lithography of aluminum for fabrication of nanomechanical systems.

Nanolithography by local anodic oxidation of surfaces using atomic force microscopy (AFM) has proven to be more reproducible when using dynamic, non-contact mode. Hereby, the tip/sample interaction forces are reduced dramatically compared to contact mode, and thus tip wear is greatly reduced. Anodic oxidation of Al can be used for fabricating nanomechanical systems, by using the Al oxide as a highly selective dry etching mask. In our experiments, areas as large as 2 micro m x 3 micro m have been oxidized repeatedly without any sign of tip-wear. Furthermore, line widths down to 10nm have been routinely obtained, by optimization of AFM parameters, such as tip/sample distance, voltage and scan speed. Finally, AFM oxidation experiments have been performed on CMOS processed chips, demonstrating the first steps of fabricating fully functional nanomechanical devices.

Journal Article↗