A phantom for simulating fast dynamic studies on a gamma camera.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to F R Hudson.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
This paper describes a new way of expressing local ventilation using a scintillation gamma camera interfaced to a digital computer. From the ratio of the first to the zeroth moment of the lung clearance curve for 13N gas, a mean transit time is calculated and displayed for different regions of the lung. Lung clearance curves following intravenously administered 13N solutions, or after equilibration with 13N gas, are measured during normal breathing. Describing regional ventilation by mean transit time during clearance uses all the counts in the lung clearance curve and the improvement in statistical accuracy compared with the height over area method using a Stewart-Hamilton equation is significant. In normal subjects the average mean transit time for clearance from the total lung field is t = (61 +/- 4) s, from the upper zone tuz = (64 +/- 4) s and from the lower zone tlz = (54 +/- 5) s. These results show uneven ventilation between regions of the normal lung in general agreement with that described by previous authors. In addition, the functional image gives the mean transit time for each cell of the 64 X 64 matrix of the computer display. The fractional error in mean transit time is 3% for an area of 2-2 cm2 corresponding to 12 cells in the display. This display provides a sensitive method, functionally and spatially, of investigating local differences in ventilation, including vertical and horizontal gradients in narrow strips of lung.
A comparison is presented of the image quality obtained with a 70 mm Ge(Li) detector scanner and with routine techniques based on NaI (Tl) detectors. One hundred and sixty-five pairs of brain scans have been examined for which the patients have been scanned with both Ge(Li) and NaI (Tl) detectors. It is concluded that no major difficulties exist in introducing Ge(Li) scanners and that while a comparison of scans from different instruments is difficult there is evidence that improved diagnostic information may be obtained from scanners with Ge(Li) detectors.
Compounds labeled with 123I are becoming more common in scintillation imaging due to the convenient combination of the 13.3-hr half-life and the 159-keV gamma radiation. Here attention is drawn to the particularly large summing effects observed when 123I is counted in a well counter. These could lead to errors in the assay of doses if the analyzer windows used are too narrow.
Explore the source record for details and available documents.
Gastric emptying of solid meals labelled with 129Cs was studied in patients for up to one year after vagotomy and antrectomy or after proximal gastric vagotomy. Significant delay was found one month after vagotomy and antrectomy but this had returned to normal by six months. No delay was found after proximal gastric vagotomy. The effect of posture on gastric emptying was also studied in the same subjects. No significant differences were found between gastric emptying in the supine or sitting positions after solid meals.
Techniques are described for simple and convenient checks on the position and size of the isocenter of radiotherapy treatment machines by measuring the displacement of the optical pointer on a flat scale on the surface of the treatment couch.