Rapid detection of D-dimer using a fiber optic biosensor.

We describe a rapid and sensitive method for detection and quantification of D-dimer and other crosslinked fibrin degradation products (XL-FDPs), which are present in elevated concentrations in patients with sepsis and thrombotic disorders. The method utilizes a sandwich fluoroimmunoassay immobilized in the sensing region of an evanescent wave biosensor. Physiological concentrations of D-dimer and high molecular weight XL-FDP could be determined in buffer and plasma samples on calibrated fibers in 11 min. Samples from septic patients were assayed using ELISA and the fiber optic method; concentrations determined by fiber optic assay were strongly correlated with those determined by ELISA (r = 0.918); intra- and inter-assay errors were comparable to those from ELISAs. Given its accuracy and rapid response time, this fiber optic biosensor shows great potential for development as a diagnostic tool.

Biosensing Techniques↗

Assessment of heterogeneity in antibody-antigen displacement reactions.

The intrinsic binding characteristics of monoclonal antibodies are modified upon immobilization onto a solid-phase matrix. Factors such as the distribution in affinity must therefore be taken into consideration in order to predict the kinetics of antibody binding at solid-liquid interfaces. A mathematical analysis is presented herein that allows the assessment of heterogeneity in the affinity of monoclonal antibodies immobilized onto a solid support. This model is based on a modified version of the Sips distribution function adapted to the conditions of a solid-phase displacement assay in flow. An assay for trinitrotoluene (TNT) provides the data to evaluate the extent of heterogeneity introduced by immobilization of antibodies in a flow immunoassay. We determined the index of antibody heterogeneity on two solid supports, controlled-pore glass beads and agarose beads, coated with a monoclonal anti-TNT antibody at varying densities. The data confirm that the threshold for crossover from homogeneous to heterogeneous forms of the reaction isotherm is different in displacement reactions than in association-dissociation reactions. Our analysis shows that the measured displacement isotherm is consistent with a homogeneous or only moderately heterogenous distribution of relative affinities.

Antibodies, Monoclonal↗

Effectiveness of protein A for antibody immobilization for a fiber optic biosensor.

The fiber optic biosensor performs fluoroimmunoassays at the surface of multimode optical fibers. The effectiveness of protein A, an immunoglobulin binding protein, for antibody immobilization on the surface of these fiber probes has been investigated. No difference was observed in the binding of fluorescently-labeled goat-IgG by rabbit anti-goat IgG regardless of whether the capture antibody was bound to the probe surface via protein A or covalently attached. However, in a sandwich immunoassay for the F1 antigen of Yersinia pestis, probes with rabbit anti-plague IgG bound to the surface via protein A generated twice the signal as probes with the antibody covalently attached. Assay regeneration was also examined with protein A probes since antibody-antigen complexes have been successfully eluted from protein A under low pH conditions. Protein A probes coated with rabbit anti-goat IgG obtained nearly identical signal levels at 500 and 5000 ng/ml of Cy5.5 goat IgG five consecutive times following regeneration with glycine-HCl, 2% acetic acid, pH 2.5.

Antigen-Antibody Reactions↗

Fiber optic-based biosensor for ricin.

We report on an evanescent wave fiber-optic biosensor for detecting a potently toxic protein, ricin, in the picograms per milliliter range. A sandwich immunoassay scheme was used to detect ricin. First, an anti-ricin IgG was immobilized onto the surface of an optical fiber in two different ways. In the first method, the antibody was directly coated to the silanized fiber using a crosslinker. Second, avidin-coated fibers were incubated with biotinylated anti-ricin IgG to immobilize the antibody using an avidin-biotin bridge. The assay using the avidin-biotin linked antibody demonstrated higher sensitivity and wider linear dynamic range than the assay using antibody directly conjugated to the surface. The linear dynamic range of detection for ricin in buffer using the avidin-biotin chemistry is 100 pg/ml-250 ng/ml. The limits of detection for ricin in buffer solution and river water are 100 pg/ml and 1 ng/ml, respectively. At higher concentrations of ricin (> 50 ng/ml), we observe a strong interaction of ricin with the avidin coated on the surface of the fibers. We have demonstrated that this interaction is primarily due to the lectin activity of ricin and is significantly reduced using fibers coated with neutravidin or by adding galactose to the ricin samples.

Adsorption↗

Antibody immobilization using heterobifunctional crosslinkers.

Covalent attachment of functional proteins to a solid support is important for biosensors. One method employs thiol-terminal silanes and heterobifunctional crosslinkers such as N-succinimidyl 4-maleimidobutyrate (GMBS) to immobilize proteins through amino groups onto glass, silica, silicon or platinum surfaces. In this report, several heterobifunctional crosslinkers are compared to GMBS for their ability to immobilize active antibodies onto glass cover slips at a high density. Antibodies were immobilized at densities of 74-220 ng/cm2 with high levels of specific antigen binding. Carbohydrate-reactive crosslinkers were also compared to GMBS using a fiber optic biosensor to detect fluorescently-labeled antigen. At the concentrations tested, the antibodies immobilized with carbohydrate-reactive crosslinkers bound more antigen than GMBS immobilized antibodies as indicated by the fluorescence signal.

Biosensing Techniques↗

Quantitating staphylococcal enterotoxin B in diverse media using a portable fiber-optic biosensor.

A new, portable fiber-optic biosensor has been used to detect staphylococcal enterotoxin B, a causative agent of food poisoning, at levels as low as 0.5 ng/ml in buffer. The toxin (SEB) can also be detected and quantitated in other relevant media: human serum, urine, and aqueous extract of ham. The level of toxin, from 5 to 200 ng/ml, can be accurately predicted in these media by calibrating each fiber and by comparing results to a single standard curve based on toxin in buffer. The quantitative fluorescent sandwich immunoassay provides results in 45 min; qualitative results are provided in 15-20 min. Using a blender and a benchtop centrifuge, fast, simple aqueous extracts of contaminated ham samples were prepared and tested. Ham spiked with 5 or 40 micrograms SEB per 100 g food resulted in biosensor readings indicative of 11 or 69% recovery of the toxin, respectively. Finally, the SEB assay is highly specific; SEA and SED give only 2-3% of the signal at 5000 ng/ml as SEB gives at 1000 ng/ml. This specific, sensitive assay for SEB on the portable fiber-optic biosensor permits easy monitoring of clinical samples or on-site analysis of suspect food samples.

Animals↗

Detection of endotoxin using an evanescent wave fiber-optic biosensor.

The lipopolysaccharide endotoxin is the most powerful immune stimulant known and a causative agent in the clinical syndrome known as sepsis. Sepsis is responsible for more than 100,000 deaths annually, in large part due to the lack of a rapid, reliable, and sensitive diagnostic technique. This study describes the detection of LPS from E. coli at concentrations as low as 10 ng/mL, in 30 s using an evanescent wave fiber-optic biosensor. Polymyxin B, covalently immobilized onto the surface of the fiber-optic probe, selectively bound fluorescently labeled LPS. Unlabeled LPS was detected in a competitive assay format using labeled LPS for signal generation. The competitive assay format worked in both buffer and plasma with similar sensitivities. This method can be used with other LPS capture molecules such as antibodies, lectins, or antibiotics, to simultaneously detect LPS and to determine the LPS serotype. The LPS assay using the fiber-optic biosensor is applicable to both clinical and environmental testing.

Biosensing Techniques↗

Use of the USDT flow immunosensor for quantitation of benzoylecgonine in urine.

The flow immunosensor works on a principle somewhat distinct from other immunoassay systems in that it performs a displacement immunoassay. Antibody-coated matrices are saturated with fluorescently labeled benzoylecgonine (BE), which is released and measured in the presence of BE-containing urine and measured downstream from the matrix. The same antibody matrix can be used for many samples. A flow immunosensor instrument, built by US Drug Testing, Inc., has recently received "Premarket Notification' (510(K)) from the Food and Drug Administration (FDA) to screen urine for the presence of the cocaine metabolite BE. The performance of the flow immunosensor for screening BE in urine was validated by comparison with results of a blind study using the Syva EMIT, the Abbott TDx and gas chromatography-mass spectroscopy (GC-MS). Potentially interfering drugs were also spiked into urine and evaluated using the flow immunosensor. While the FDA approval is for determining whether the BE concentration is above or below the 300 micrograms/l cutoff recommended by the National Institute of Drug Abuse, we have also shown that the flow immunosensor can be adapted to produce quantitative determinations of the amount of BE in the urine samples. The reliability of the quantitation was confirmed by testing 100 urine samples containing unknown amounts of BE using the flow immunosensor. GC-MS and the Abbott TDx system. Comparison of quantitative data obtained using the immunosensor and GC-MS showed a 97% correlation, compared with a much lower value for data from the TDx and GC-MS.

Antibody Specificity↗

Calibration of biosensor response using simultaneous evanescent wave excitation of cyanine-labeled capture antibodies and antigens.

Fiber optic biosensors have proven their ability to detect antigens rapidly in a variety of environmental and clinical samples. These biosensors are based on the technique of covalently linking antibodies to the core of an optical fiber and detecting antigen binding via measurement of fluorescence induced in the evanescent wave. One problem associated with these biosensors is the fiber-to-fiber variability in measured signal. We have addressed this problem by labeling a portion of the immobilized capture antibody with the fluorescent cyanine dye Cy5.5 (emission lambda max = 696 nm). The antigen was then labeled with fluorescent Cy5 (emission lambda max = 668 nm). Both fluorophores were excited by 635-nm light, and their emission was collected using both a fiber optic spectrometer and a biosensor optimized to collect fluorescence at two wave-lengths. The fluorescence from the Cy5.5-labeled capture antibody served as a calibration signal for each fiber and corrected for differences in optics, fiber defects, and varying amounts of capture antibody present on the fiber. Our data show that normalizing the signal measured from Cy5-labeled antigen binding to the Cy5.5 signal provides a standardization process for greatly reducing signal variance among individual fibers.

Animals↗

Detection of Yersinia pestis fraction 1 antigen with a fiber optic biosensor.

A fiber optic biosensor was used to detect the fraction 1 (F1) antigen from Yersinia pestis, the etiologic agent of plague. The instrument employs an argon ion laser (514 nm) to launch light into a long-clad fiber and measures the fluorescence produced by an immunofluorescent complex formed in the evanescent wave region. This sensing area is a short section (12.5 cm) at the end of the optical fiber from which the cladding has been removed and in which the silica core has been tapered. Capture antibodies, which bind to F1 antigen, were immobilized on the core surface to form the basis of the sandwich fluoroimmunoassay. The ability to detect bound F1 antigen was provided by adding tetramethylrhodamine-labeled anti-plaque antibody to form fluorescent complexes. The evanescent wave has a limited penetration depth (< 1 lambda), which restricts detection of the fluorescent complexes bound to the fiber's surface. The direct correlation between the F1 antigen concentration and the signal provided an effective method for sample quantitation. This method achieved a high level of accuracy for determining F1 antigen concentrations from 50 to 400 ng/ml in phosphate-buffered saline, serum, plasma, and whole blood, with a 5-ng/ml limit of detection. Subsequent blind studies, which included serum samples from patients, yielded results in good agreement with measurements by enzyme-linked immunosorbent assay. A major advantage of the fiber optic biosensor is that results can be generated within minutes while isolating the user from hazardous samples. These factors favor development of this biosensor into a facile and rapid diagnostic device.

Animals↗

Effect of antibody density on the displacement kinetics of a flow immunoassay.

This study investigates the effect of antibody density on the kinetics of a solid-phase displacement immunoassay. Conducted in flow under nonequilibrium conditions, the assay utilizes a monoclonal antibody to the cocaine metabolite benzoylecgonine, which has been immobilized onto Sepharose beads and saturated with fluorophore labeled antigen. Displacement of antibody-bound labeled antigen by non-labeled antigen occurs when sample is introduced in the buffer flow. Comparison of matrices coated with two different antibody densities revealed that the displacement efficiency is a function of the density of antibody-bound labeled antigen. A higher density of antibody provides a higher amount of displaced labeled antigen, but the displacement efficiency of the assay is decreased. The effect of antibody density on the immunoassay kinetics was analyzed using a mathematical formulation developed to characterize antibody-antigen interactions at solid-liquid interfaces. Higher antibody density proved to be associated with a lower apparent dissociation rate constant. The implications of these results on the design of immunoassays in flow are discussed.

Animals↗

Regeneration of immobilized antibodies on fiber optic probes.

The regeneration of antibodies covalently immobilized to an optical fibre surface was investigated by dissociation of the antibody-antigen complex with three different solvents: (a) an acidic solution (0.1 M glycine hydrochloride in 50% (v/v) ethylene glycol, pH 1.75), (b) a basic solution (0.05 M tetraethylamine in 50% (v/v) ethylene glycol, pH 11.0) and (c) 50% (v/v) ethanol in PBS. The fibres coated with polyclonal rabbit anti-goat antibody against a large protein retained 70% and 65% of the original signal after five consecutive regenerations with acidic and basic solvent systems, respectively. The fibres coated with monoclonal mouse anti-trinitrobenzene antibody specific for a small organic molecule, retained over 90% of the original signal when regenerated with basic and ethanol solutions. This study evaluated regeneration and reuse of antibody-coated fibre optic biosensors as a means of reducing routine laboratory analysis costs and time.

Animals↗

An evanescent wave biosensor--Part I: Fluorescent signal acquisition from step-etched fiber optic probes.

A fiber-optic biosensor capable of remote continuous monitoring has recently been designed. To permit sensing at locations separate from the optoelectronic instrumentation, long optical fibers are utilized. An evanescent wave immuno-probe is prepared by removing the cladding near the distal end of the fiber and covalently attaching antibodies to the core. Probes with a radius unaltered from that of the original core inefficiently returned the signal produced upon binding the fluorescent-labelled antigen. To elucidate the limiting factors in signal acquisition, a series of fibers with increasingly reduced probe core radius was examined. The results were consistent with the V-number mismatch, the difference in mode carrying capacity between the clad and unclad fiber, being a critical factor in limiting signal coupling from the fiber probe. However, it was also delineated that conditions which conserve excitation power, such that power in the evanescent wave is optimized, must also be met to obtain a maximal signal. The threshold sensitivity for the optimal step-etched fiber probe was improved by over 20-fold in an immunoassay, although, it was demonstrated that signal acquisition decreased along the probe length, suggesting that a sensor region of uniform radius is not ideal.

Biosensing Techniques↗

An evanescent wave biosensor--Part II: Fluorescent signal acquisition from tapered fiber optic probes.

A biosensor was developed using antibodies, fluorescence and the evanescent wave to detect antigen binding at the surface of an optical fiber. Cladding was removed from the core along the distal end of a step-index optical fiber, and recognition antibodies were immobilized on the declad core to form the probe sensing region. Immersing the declad probe in aqueous solution creates a V-number mismatch between the immersed probe and the clad fiber. Probes created with reduced sensing region radius exhibited improved response by decreasing the V-number mismatch. Tapering the radius of this region has further improved probe response. Ray tracing analysis of the tapered probe demonstrated that the evanescent wave penetration depth increases along the length of the taper. Experiments correlating position of refraction along the taper with launch angle at the proximal end were realized in the ray tracing model. An evanescent wave immunoassay was performed with a series of the tapered fiber probes, each tapered from the fiber core radius (100 microns) to different end radii. An end radius of 29 microns was found to produce maximal signal from the tapered probe. Factors leading to the determination of the optimized probe are discussed.

Biosensing Techniques↗

Inclusion of ganglioside GM1 into liposome encapsulated hemoglobin does not extend circulation persistence at clinically relevant doses.

This investigation has evaluated the substitution of ganglioside GM1 for dimyristoyl phosphatidylglycerol (DMPG) in the preparation of liposome encapsulated hemoglobin (LEH), with the intention of increasing the circulation persistence of this potential oxygen carrier. Although equivalent yields of each formulation were produced by microfluidization, the hemoglobin encapsulation efficiency was greater for GM1-LEH than DMPG-LEH. Similar particle sizes, phospholipid content, methemoglobin levels, and oxygen-carrying capacity were observed for both formulations. Zeta potential measurements to monitor liposomal surface charge showed GM1-LEH to be more electropositive than DMPG-LEH. Using differential scanning calorimetry, similar enthalpy values and hemoglobin structural transition temperatures were determined for both LEH formulations. Circulation persistence of each LEH formulation was determined following a 0.25 ml (1 g phospholipid/Kg body weight) or 0.5 ml (2 g phospholipid/Kg body weight) injection in mice. During the first 18 hours, GM1-LEH was cleared at a faster rate than DMPG-LEH at both dosages studied. Then the remaining liposomes of each formulation were removed with identical circulation profiles until no liposomes were remaining in circulation at either 50 hours (0.25 ml) or 72 hours (0.5 ml) post-injection. These data reveal that the use of ganglioside GM1 to solely increase the circulation persistence of LEH was of little benefit.

Animals↗

Optical immunosensors.

The development of biochemical detection systems that use antibodies as the recognition element, also known as immunosensors, has generated considerable interest from science and industry alike. This is due to the practically inexhaustible number of applications for which such a technology could conceivable lend itself, such as medicine, process control, and environmental monitoring. The potentially high sensitivity of such systems makes them ideal for situations where the utmost speed and accuracy are demanded. Moreover, there is theoretically no limit to the chemical and biological moieties for which an immunosensor can be manufactured. This critical review emphasizes both the biological and transduction aspects of optical immunosensors. The basic concepts of antibody-antigen interactions in solution are reviewed, and factors affecting the kinetics at the solid-liquid interface are characterized. In addition, the aspects of reagent immobilization, inherent to immunosensor design, are discussed. Finally, a comprehensive overview describing the mechanisms, advantages, and shortcomings of several immunosensing formats such as fiber-optic, planar waveguide, surface plasmon resonance, and continuous-flow immunosensor is presented. The future of these sensors, we well as the integration of fluorescence lifetime sensing and fluorescent polarization technologies with immunosensing technologies, is contemplated, posing the question: What place will immunosensors secure in tomorrow's market?

Antigen-Antibody Reactions↗

Fabrication of surfaces resistant to protein adsorption and application to two-dimensional protein patterning.

Proteins were attached in defined geometric patterns on a surface. A prerequisite to making a pattern of proteins is generation of surfaces resistant to nonspecific protein adsorption. This was accomplished via oxidation of the thiol terminus of an organosilane self-assembled monolayer film by deep ultraviolet (DUV) irradiation. The resultant surface exhibited marked resistance to protein adsorption. Using a mask to protect regions of the silanized surface from irradiation, proteins were selectively adsorbed or attached via covalent linkage at locations protected from the DUV light. Antibodies immobilized in patterns using this procedure retained their antigen-binding capability. Thus chemistry and DUV lithography were combined to create patterns of active biomolecules which could be used in the microfabrication of electronic devices and biosensors.

Adsorption↗

Kinetics of antibody binding at solid-liquid interfaces in flow.

We have developed the theoretical framework for a displacement immunoassay conducted in flow under nonequilibrium conditions. Using a repetitive displacement technique, we determined the displacement rate and apparent dissociation rate constant at different flow rates. Our data suggest that the kinetics are best described by a first-order function. The displacement efficiency, the displacement rate, and therefore the apparent dissociation rate constant were calculated and demonstrated to be flow rate dependent. The theoretical framework developed in this study was successful in predicting the behavior of antigen displacement in flow.

Antibodies, Monoclonal↗