PubMed Health⌕ Search

Biomedical subjects

F Spurny

Publications and source records attributed to F Spurny.

13 recordsLinked to original sources

The comparison of calculated and experimental microdosimetric distributions for carbon ions.

The aim of this work is to present microdosimetric characteristics of 400 MeV amu(-1) and 500 MeV amu(-1) carbon ions obtained by theoretical calculations and to analyse them with respect to experimental data obtained by tissue-equivalent proportional counter in a scope of project ICCHIBAN and by etched track detector CR 39 Page irradiated by LHE nuclotron at JINR, Dubna, Russia. Track structures provided by Monte Carlo code TRIOL are used as an input data for calculations of energy distributions. The calculations of frequency f(y) and dose d(y) distributions are performed using own developed programs.

Animals↗

Radiation dosimetry for microbial experiments in the International Space Station using different etched track and luminescent detectors.

The laboratory of Microbiology at SCK.CEN, in collaboration with different universities, participates in several ESA programmes with bacterial experiments that are carried out in the International Space Station (ISS). The main objective of these programmes is to study the effects of space flight conditions such as microgravity and cosmic radiation on the general behaviour of model bacteria. To measure the radiation doses received by the bacteria, different detectors accompanied the microbiological experiments. The results obtained during two space flight missions are discussed. This dosimetry experiment was a collaboration between different institutes so that the doses could be estimated by different techniques. For measurement of the high linear energy transfer (LET) doses (>10 keV microm(-1)), two types of etched track detectors were used. The low LET part of the spectrum was measured by three types of thermoluminescent detectors ((7)LiF:Mg,Ti; (7)LiF:Mg,Cu,P; Al(2)O(3):C) and by the optically stimulated luminescence technique using Al(2)O(3):C detectors.

Cosmic Radiation↗

An international dosimetry exchange for boron neutron capture therapy. Part I: Absorbed dose measurements.

An international collaboration was organized to undertake a dosimetry exchange to enable the future combination of clinical data from different centers conducting neutron capture therapy trials. As a first step (Part I) the dosimetry group from the Americas, represented by MIT, visited the clinical centers at Studsvik (Sweden), VTT Espoo (Finland), and the Nuclear Research Institute (NRI) at Rez (Czech Republic). A combined VTT/NRI group reciprocated with a visit to MIT. Each participant performed a series of dosimetry measurements under equivalent irradiation conditions using methods appropriate to their clinical protocols. This entailed in-air measurements and dose versus depth measurements in a large water phantom. Thermal neutron flux as well as fast neutron and photon absorbed dose rates were measured. Satisfactory agreement in determining absorbed dose within the experimental uncertainties was obtained between the different groups although the measurement uncertainties are large, ranging between 3% and 30% depending upon the dose component and the depth of measurement. To improve the precision in the specification of absorbed dose amongst the participants, the individually measured dose components were normalized to the results from a single method. Assuming a boron concentration of 15 microg g(-1) that is typical of concentrations realized clinically with the boron delivery compound boronophenylalanine-fructose, systematic discrepancies in the specification of the total biologically weighted dose of up to 10% were apparent between the different groups. The results from these measurements will be used in future to normalize treatment plan calculations between the different clinical dosimetry protocols as Part II of this study.

Biophysical Phenomena↗

Investigations of doses on board commercial passenger aircraft using CR-39 and thermoluminescent detectors.

Measurements of cosmic radiation dose rates (from the neutron and the non-neutron components) on board passenger aircraft were performed using environmental packages with thermoluminescent TL and CR-39 etched track detectors. The packages were calibrated at the CERN-EU high-energy Reference Field Facility and evaluated at the Institute of Nuclear Physics in Krakow (TL + CR-39) and at the German Aerospace Centre in Cologne (CR-39). Detector packages were exposed on board passenger aircraft operated by LOT Polish Airlines, flown between February and May 2001. The values of effective dose rate determined, averaged over the measuring period, ranged between 2.9 and 4.4 microSv h(-1). The results of environmental measurements agreed to within 10% with values calculated from the CARI-6 code.

Aircraft↗

Exposure of aircraft crew to cosmic radiation: on-board intercomparison of various dosemeters.

Owing to their professional activity, flight crews may receive a dose of some millisieverts within a year; airline passengers may also be concerned. The effective dose is to be estimated using various experimental and calculation tools. The European project DOSMAX (Dosimetry of Aircrew Exposure during Solar Maximum) was initiated in 2000 extending to 2004 to complete studies over the current solar cycle during the solar maximum phase. To compare various dosemeters in real conditions simultaneously in the same radiation field, an intercomparison was organised aboard a Paris-Tokyo round-trip flight. Both passive and active detectors were used. Good agreement was observed for instruments determining the different components of the radiation field; the mean ambient dose equivalent for the round trip was 129 +/- 10 microSv. The agreement of values obtained for the total dose obtained by measurements and by calculations is very satisfying.

Aircraft↗

Long-term monitoring of the onboard aircraft exposure level with a Si-diode based spectrometer.

The radiation fields onboard aircraft are complex (EURADOS, 1996), and several methods are used to characterise them for radiation protection. We have tested a spectrometer based on Si-diode at different sources and accelerator facilities. The energy deposited in the diode is analysed to estimate the contribution of different radiations to dosimetry quantities. The spectrum of energy deposition events onboard aircraft is similar to that registered in the CERN high-energy reference field. We used this similarity to determine the correction factors to appreciate radiation protection quantities from the results of onboard measurements. During 2001-2002, the spectrometer was used to acquire measurements onboard commercial aircraft during five long-term exposures. All necessary flight parameters were acquired; thus permitting calculations of the onboard effective dose and/or ambient dose equivalent by means of both the CARI 6 and the EPCARD codes and comparison with the results of the measurements. It was found that the apparent ambient dose equivalent values from measured data are in reasonable agreement with the results of calculations. Quantitative analysis of this agreement as a function of flight parameters (geomagnetic position, solar activity variations, etc.) is presented. During one flight, an important solar event (GLE 60 on 15 April 2001) was recorded by the spectrometer. In some other cases the measurements during a Forbush decreases were acquired. These extremes were well registered by the equipment and the data obtained are analyzed.

Aircraft↗

Calibration results obtained with Liulin-4 type dosimeters.

The Mobile Radiation Exposure Control System's (Liulin-4 type) main purpose is to monitor simultaneously the doses and fluxes at 4 independent places. It can also be used for personnel dosimetry. The system consists of 4 battery-operated 256-channel dosimeters-spectrometers. We describe results obtained during the calibrations of the spectrometers at the Cyclotron facilities of the University of Louvain, Belgium and of the National Institute of Radiological Sciences-STA, Chiba, Japan with protons of energies up to 70 MeV. The angular sensitivities of the devices are studied and compared with Monte-Carlo predictions. We also present the results obtained at the HIMAC accelerator with 500 MeV/u Fe ions and at the CERN high energy radiation reference fields. Records made during airplane flights are shown and compared with the predictions of the CARI-6 model.

Aerospace Medicine↗

Microdosimetric spectra and LET distributions on board the Mir space station obtained with a particle track detector.

A spectrometer measuring energy lost (deltaE) was used to determine linear energy transfer (LET) spectra on board the Mir orbital station during the period from 8 October 1997 to 16 June 2000, i.e. during the 24th, 26th, 27th and 28th basic expeditions. It was found that the LET spectra of secondary particles between 10 and 700 keV.microm(-1) in tissue do not depend on the external radiator, with the average quality factors for the region mentioned being about 6.4 with ICRP 26 quality factors or about 7.4 with ICRP 60 quality factors. Both differential and integral LET spectra are presented for some typical cases. The spectra permitted us to calculate the total doses and dose equivalents due to particles with the LET values in the mentioned region. It was found that these doses are higher when the detector was placed in a less shielded area. It was also found that these doses vary from one expedition to another. The correlation of these variations with the solar activity level was studied.

Aerospace Medicine↗

Dosimetry during the first IBIS facility flight.

The dosimetry of cosmic rays was performed during the first experimental flight of the IBIS facility. Different thermoluminescent detectors (TLD) have been used to measure the contribution of the low linear energy transfer component (LET < 10 keV/micrometer) and plastic nuclear track detectors (PNTD) for the high linear energy tranfer (LET) component. Several parameters of tracks have been measured to determine the LET spectra of primary and secondary charged particles. The total absorbed dose rate (TLD+PNTD) during the flight was 0.23 mGy/day and the dose equivalent rate using the ICRP 60 was 0.52 mSv/day. The corresponding mean quality factor was 2.4. These results are in agreement with those obtained aboard the MIR station with a tissue equivalent proportional counter.

Cosmic Radiation↗

Dosimetry for occupational exposure to cosmic radiation.

In the course of their work, aircraft crew and frequent flyers are exposed to elevated levels of cosmic radiation of galactic and solar origin and secondary radiation produced in the atmosphere, aircraft structure, etc. This has been recognised for some time and estimates of the exposure of aircraft crew have been made previously and included in, for example, UNSCEAR (United Nations Scientific Committee on the Effects of Atomic Radiation) publications. The recent increased interest has been brought about by several factors--the consideration that the relative biological effectiveness of the neutron component as being underestimated; the trend towards higher cruising altitudes for subsonic commercial aircraft and business jet aircraft; and, most importantly, the recommendations of the International Commission on Radiological Protection (ICRP) in Publication 60, and the revision of the Euratom Basic Safety Standards Directive (BSS). In 1992, the European Dosimetry Group (EURADOS) established a Working Group to consider the exposure to cosmic radiation of aircraft crew, and the scientific and technical problems associated with radiation protection dosimetry for this occupational group. The Working Group was composed of fifteen scientists (plus a corresponding member) involved in this field of study and with knowledge of radiation measurement at aviation altitudes. This paper is based on the findings of this Working Group. Where arrangements are made to take account of the exposure of aircraft crew to cosmic radiation, dose estimation procedures will not be necessary for persons for whom total annual doses are not liable to exceed 1 mSv, and therefore, in general, for crew on aircraft not routinely flying above 8 km. Where estimates of effective dose and, in the case of female staff who are pregnant, equivalent dose to the embryo or fetus, are required (for regulatory or other purposes), it was concluded that the preferred procedure was to determine route doses and fold these with data on staff rostering.

Aircraft↗

Ionizing radiation fluxes and dose measurements during the Kosmos 1887 satellite flight.

The results of dosimetric experiments performed during the flight of Kosmos 1887 biosatellite are presented. Two kinds of measurements were performed on the external surface of the satellite. First, the fluences and spectra of low energy charged particles were established. It was found that most of the particles registered by means of solid state nuclear track detectors are helium nuclei. Tracks of oxygen nuclei and some heavier charged particles were also observed. Thermoluminescent detectors were used to establish absorbed doses in open space on the satellite's surface and behind thin shielding. It was found that these doses were rather high; nevertheless, their decrease with shielding thickness is very rapid. Dosimetric and other consequences of the results obtained are analyzed and discussed.

Collodion↗

Absorbed dose measurements on external surface of Kosmos-satellites with glass thermoluminescent detectors.

In this paper we present absorbed dose measurements with glass thermoluminescent detectors on external surface of satellites of Kosmos-serie flying in 1983-87. Experiments were performed with thermoluminescent aluminophosphate glasses of thicknesses 0.1, 0.3, 0.4, 0.5, and 1 mm. They were exposed in sets of total thickness between 5 and 20 mm, which were protected against sunlight with thin aluminized foils. In all missions, extremely high absorbed dose values were observed in the first layers of detectors, up to the thickness of 0.2 to 0.5 gcm-2. These experimental results confirm that, during flights at 250 to 400 km, doses on the surface of the satellites are very high, due to the low energy component of the proton and electron radiation.

Cosmic Radiation↗