PubMed · 11542780
Dosimetry during the first IBIS facility flight.
Abstract
The dosimetry of cosmic rays was performed during the first experimental flight of the IBIS facility. Different thermoluminescent detectors (TLD) have been used to measure the contribution of the low linear energy transfer component (LET < 10 keV/micrometer) and plastic nuclear track detectors (PNTD) for the high linear energy tranfer (LET) component. Several parameters of tracks have been measured to determine the LET spectra of primary and secondary charged particles. The total absorbed dose rate (TLD+PNTD) during the flight was 0.23 mGy/day and the dose equivalent rate using the ICRP 60 was 0.52 mSv/day. The corresponding mean quality factor was 2.4. These results are in agreement with those obtained aboard the MIR station with a tissue equivalent proportional counter.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
J F Bottollier-Depois, F Spurny, L Plawinski, I Votockova, J Bednar, M Viso, A Labarthe. 1998. Dosimetry during the first IBIS facility flight.. https://doi.org/10.1016/s0273-1177(98)01072-2