High throughput flow cytometry.

BACKGROUND: Conventional flow cytometry does not allow the rapid analysis of multiple samples. This has limited its uses in drug discovery, for which the standard for throughput is 100,000 samples per day. METHODS: We describe a simple method in which commercial peristaltic tubing is connected from a commercial autosampler to a flow cytometer. The samples are delivered via a peristaltic pump from source wells in a multiwell plate. The samples are separated by air bubbles. RESULTS: Throughput rates approach the limit of the autosampler (up to 100 wells per minute). Using optimal tubing and flow rates, particles remain within appropriate light scatter and fluorescence gates. The carryover between wells is typically less than 5% without and 1% with a wash step. The volumes of sample delivered are in the microliter scale. The approach has been validated with instruments from three manufacturers. CONCLUSIONS: Flow cytometry has potential throughput of 100,000 samples or more per day starting with the method described. The method is currently best suited to end-point assays. However, combined with high-speed sorting and single- cell assays, the number of assays could approach 1 billion per day.

Flow Cytometry↗

Plug flow cytometry extends analytical capabilities in cell adhesion and receptor pharmacology.

BACKGROUND: Plug flow cytometry is a recently developed system for the automated delivery of multiple small boluses or "plugs" of cells or particles to the flow cytometer for analysis. Important system features are that sample plugs are of precisely defined volume and that the sample vessel need not be pressurized. We describe how these features enable direct cell concentration determinations and novel ways to integrate flow cytometers with other analytical instruments. METHODS: Adhesion assays employed human polymorphonuclear neutrophils (PMNs) loaded with Fura Red and Chinese hamster ovary (CHO) cells cotransfected with genes for green fluorescent protein (GFP) and human P-selectin. U937 cells expressing the human 7-transmembrane formyl peptide receptor were loaded with the fluorescent probe indo-1 for intracellular ionized calcium determinations. A computer-controlled syringe or peristaltic pump loaded the sample into a sample loop of the plug flow coupler, a reciprocating eight-port valve. When the valve position was switched, the plug of sample in the sample loop was transported to the flow cytometer by a pressure-driven fluid line. RESULTS: In stirred mixtures of PMNs and CHO cells, we used plug flow cytometry to directly quantify changes in concentrations of nonadherent singlet PMNs. This approach enabled accurate quantification of adherent PMNs in multicell aggregates. We constructed a novel plug flow interface between the flow cytometer and a cone-plate viscometer to enable real-time flow cytometric analysis of cell-cell adhesion under conditions of uniform shear. The High Throughput Pharmacology System (HTPS) is an instrument used for automated programming of complex pharmacological cell treatment protocols. It was interfaced via the plug flow coupling device to enable rapid (< 5 min) flow cytometric characterization of the intracellular calcium dose-response profile of U937 cells to formyl peptide. CONCLUSIONS: By facilitating the coupling of flow cytometers to other fluidics-based analytical instruments, plug flow cytometry has extended analytical capabilities in cell adhesion and pharmacological characterization of receptor-ligand interactions.

Animals↗

HTPS flow cytometry: a novel platform for automated high throughput drug discovery and characterization.

The flow cytometer is unique among biomedical analysis instruments because it makes simultaneous and multiple optical measurements on individual cells or particles at high rates. High throughput flow cytometry represents a potentially important multifactorial approach for screening large combinatorial libraries of compounds. Limiting this approach has been the availability of instrumentation and methods in flow cytometry for automated sample handling on the scale required for drug discovery applications. Here, we describe an automated system in which a novel patented fluidics-based pharmacology platform, the HTPS (High Throughput Pharmacological System), is coupled to a flow cytometer using a recently described plug flow-coupling valve technology. Individual samples are aspirated sequentially from microplate wells and delivered to a flow cytometer for rapid multiparametric analysis. For primary screening to detect and quantify cell fluorescence in endpoint assays, a high-speed no-wash protocol enabled processing of 9-10 cell samples/min from 96-well microplates. In an alternate primary screening format, soluble receptor ligands were sampled from microplate wells at rates of 3-4 samples/minute and successfully assessed for the ability to elicit intracellular calcium responses. Experiments with fluorescent beads validated the accurate automated production by the HTPS of exponential and linear gradients of soluble compounds. This feature enabled rapid (2- to 3-min) characterization of the intracellular calcium dose response of myeloid cells to formyl peptide as well as the quantitative relationship between formyl peptide receptor occupancy and cell response. HTPS flow cytometry thus represents a powerful high throughput multifactorial approach to increase the efficiency with which novel bioresponse-modifying drugs may be identified and characterized.

Automation↗

Analysis of free intracellular calcium by flow cytometry: multiparameter and pharmacologic applications.

Flow cytometry offers numerous advantages over traditional techniques for measuring intracellular Ca(2+) in lymphoid and nonlymphoid cells. In particular, the heterogeneity of cell responses can be defined by flow cytometry, and multiparameter analyses permit the determination of intracellular Ca(2+) in surface-marker-defined target cells as well as correlation of changes in Ca(2+) with other biochemical markers, including ligand binding. This article presents several established methods for measuring intracellular Ca(2+) by flow cytometry in lymphoid and nonlymphoid cells. Examples are provided for determination of Ca(2+) in human peripheral blood leukocytes and two human epithelial cell lines grown in monolayer. In addition, applications are reviewed or presented for correlating changes in intracellular Ca(2+) with other cell parameters, including cell cycle analysis, changes in cell membrane integrity, and the induction of apoptosis markers. Finally, a number of novel sample handling capabilities useful for performing kinetic analyses of Ca(2+) changes by flow cytometry are now available and one application is presented which is finding utility in pharmacologic studies.