PubMed · 11309812

High throughput flow cytometry.

Abstract

BACKGROUND: Conventional flow cytometry does not allow the rapid analysis of multiple samples. This has limited its uses in drug discovery, for which the standard for throughput is 100,000 samples per day. METHODS: We describe a simple method in which commercial peristaltic tubing is connected from a commercial autosampler to a flow cytometer. The samples are delivered via a peristaltic pump from source wells in a multiwell plate. The samples are separated by air bubbles. RESULTS: Throughput rates approach the limit of the autosampler (up to 100 wells per minute). Using optimal tubing and flow rates, particles remain within appropriate light scatter and fluorescence gates. The carryover between wells is typically less than 5% without and 1% with a wash step. The volumes of sample delivered are in the microliter scale. The approach has been validated with instruments from three manufacturers. CONCLUSIONS: Flow cytometry has potential throughput of 100,000 samples or more per day starting with the method described. The method is currently best suited to end-point assays. However, combined with high-speed sorting and single- cell assays, the number of assays could approach 1 billion per day.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F W Kuckuck, B S Edwards, L A Sklar. 2001-05-01. High throughput flow cytometry.. https://pubmed.ncbi.nlm.nih.gov/11309812/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Real-time quantitation of HIV-1 p24 and SIV p27 using fluorescence-linked antigen quantification assays.

We developed fluorescence-linked antigen quantification (FLAQ) assays for HIV-1 and SIV antigen quantitation. The assays utilize polystyrene microspheres coated with monoclonal antibodies against HIV-1 Gag p24 or SIV Gag p27, which are incubated with unknown samples, flourochrome-conjugated detector antibody, and lysing agent. The fluorescence of individual microspheres is measured using flow cytometry. The speed, simplicity, and wide dynamic range of FIAQ assays makes them superior to enzyme-linked immunosorbent assays for many applications performed in research laboratories.

Flow Cytometry↗

Intravenous immunoglobulin-induced panel reactive antibody A reduction: not all preparations are created equal.

BACKGROUND: Use of intravenous (IV) immunoglobulin (Ig) to obtain panel reactive antibody (PRA) A reduction in sensitized patients has been widely reported. Because no IVIg preparation is formulated specifically for this purpose, the authors have sought to determine whether, through laboratory testing, they could guide the rational choice of product for clinical use. METHODS: Using a flow cytometric approach, the authors have quantitatively determined the capacity of 22 different IVIg preparations to cause PRA reduction. RESULTS: IVIg preparations showed considerable variability in their individual capacity to reduce serum PRA. Protein-A pretreatment of IVIg preparations was found to reduce their capacity to cause PRA reduction. CONCLUSION: Laboratory screening of IVIg preparations provides a rational basis for the selection of product for administration to patients in whom the aim is to produce a PRA reduction. Experiments involving protein-A treatment of IVIg preparations indicate that immunoglobulin G is the principal factor involved in the abrogation of serum reactivity.

Flow Cytometry↗