PubMed Health⌕ Search

Biomedical subjects

Ferdinand Frauscher

Publications and source records attributed to Ferdinand Frauscher.

At least 37 records · Page 2Linked to original sources

Prostate cancer detection in men with prostate specific antigen 4 to 10 ng/ml using a combined approach of contrast enhanced color Doppler targeted and systematic biopsy.

PURPOSE: Transrectal gray scale ultrasound guided biopsy is the standard method for diagnosing prostate cancer (PC). Improved cancer detection with ultrasound contrast agents is related to better detection of tumor vascularity. We evaluated the impact of a combined approach of contrast enhanced, color Doppler targeted biopsy (CECD) and systematic biopsy (SB) for the PC detection rate in men with prostate specific antigen (PSA) 4.0 to 10 ng/ml. MATERIALS AND METHODS: We examined 380 screening volunteers with a total PSA of 4.0 to 10 ng/ml (percent free PSA less than 18). CECD was always performed before SB. Another investigator blinded to contrast enhanced findings performed 10 SBs. The cancer detection rate for the CECD, SB and combined approaches was assessed. RESULTS: PC was detected in 143 of 380 patients (37.6%, mean total PSA 6.2 ng/ml). The PC detection rate for CECD and for SB was 27.4% and 27.6%, respectively. The overall cancer detection rate with the 2 methods combined was 37.6%. For targeted biopsy cores the detection rate was significantly better than for SB cores (32.6% vs 17.9%, p <0.01). CECD in a patient with cancer was 3.1-fold more likely to detect PC than SB. CONCLUSIONS: CECD allows for the detection of lesions that cannot be found on gray scale ultrasound or SB. CECD allows for assessment of neovascularity associated with PC. However, the combined use of CECD and SB allows for maximal detection of PC with a detection rate of 37.6% in our patients with PSA 4 to 10 ng/ml.

Adult↗

Vascular damage as a risk factor for benign prostatic hyperplasia and erectile dysfunction.

OBJECTIVE: To assess benign prostatic hyperplasia (BPH) and erectile dysfunction (ED), both considered to be associated with urogenital ageing, in ageing men in a cross-sectional population study, comparing them with healthy controls by using symptom scores and contrast-enhanced colour Doppler ultrasonography (CDUS). PATIENTS, SUBJECTS AND METHODS: Transrectal CDUS and quantitative measurement of colour pixel intensity (CPI) are excellent minimally invasive techniques for assessing normal and pathological blood flow. CDUS was performed using the microbubble-based ultrasound enhancer for evaluating prostate, bladder neck and corpus cavernosum vascularity in young healthy men, men with BPH, and men with severe vascular damage (diabetes mellitus type 2). Resistive index measurements and computer-assisted quantification of CPI were used to objectively evaluate perfusion. The International Prostate Symptom Score (IPSS) and the International Index of Erectile Function (IIEF) were applied to quantify the symptoms. RESULTS: In patients with BPH, perfusion of the transition zone (TZ) of the prostate was significantly lower and the resistive index of the TZ significantly higher (both P < 0.001) than in healthy controls. The perfusion patterns of men with BPH and those who also had severe vascular damage (diabetes mellitus type 2) showed that vascularity in the latter group was lower in the prostatic TZ and the corpora cavernosa. In patients with BPH the IPSS, quality-of-life and IIEF scores were significantly worse than in the control group. Men with concomitant atherosclerosis had even worse symptom scores. CONCLUSION: These results strongly support the hypothesis that age-related impairment of blood supply to the lower urinary tract is important in the development of BPH and ED. Vascular damage may cause chronic ischaemia and thus be a contributing factor in the pathogenesis of BPH and ED.

Adult↗

Changes of renal blood flow in nephroptosis: assessment by color Doppler imaging, isotope renography and correlation with clinical outcome after laparoscopic nephropexy.

OBJECTIVE: Previously, we have detected changes in renal blood flow secondary to nephroptosis by assessing the renal resistive index (RI) using color Doppler imaging (CDI). The aim of the current study was to compare two diagnostic methods, CDI and isotope renography (IRG), for detection of renal blood flow impairment in patients with nephroptosis. METHODS: 26 patients with nephroptosis and flank pain underwent CDI and isotope renography (IRG) before and after laparoscopic nephropexy. The RI was assessed in segmental arteries with the patient in both the supine and erect position. Pre- and postoperative patient symptoms, results of Doppler measurements and IRG findings were assessed. RESULTS: Preoperatively, 23 of 26 symptomatic patients showed a mean reduction in RI of more than 0.10 on the affected side, while only 7 of 26 patients had abnormal findings on preoperative IRGs. Postoperatively, none of the patients with preoperative changes in Doppler parameters showed any posture-related changes in RI. On postoperative IRG, obtained in 4 of 7 patients, normalization of renal perfusion was documented. Twenty out of 26 patients were asymptomatic postoperatively; in the remaining 6 patients symptoms were markedly improved. CONCLUSION: Impairment of renal blood flow due to nephroptosis was detected with both CDI and IRG. RI measurement by CDI appears to be significantly more sensitive in detecting renal blood flow impairment. RI should be assessed in patients with nephroptosis and may impact on the decision for laparoscopic nephropexy.

Adult↗

Power Doppler ultrasound imaging for quantification of urinary bladder neck blood flow changes.

This study was designed to evaluate power Doppler imaging for assessment of urinary bladder neck blood flow in comparison with laser Doppler flowmetry (LDF) in an animal model. Transrectal power Doppler ultrasound (US) and LDF of the urinary bladder neck were performed in three anesthetized pigs during comparative cystometry. Normal saline (NaCl) was used for the first run, followed by a second run with 0.2 mol/L potassium chloride (KCl). Standardized sonographic equipment settings (Acuson Sequoia 512); MountainView, CA) were used for power Doppler imaging. Computer-assisted calculation of color pixel density (CPD) of power Doppler images was performed using Scion Image) software image analysis. Tissue perfusion units (TPU) were measured using a BLF21 laser Doppler flowmeter (Transonic Systems Inc., Ithaca, NY, USA). The power Doppler results were compared with the findings obtained by LDF. NaCl filling resulted in a mean CPD increase at the bladder neck from 18.65 (+/- 1.78) at empty bladder to 37.8 (+/- 1.84) at 100 mL and to 88.32 (+/- 1.35) at full bladder capacity (C(max)) of 270 mL, respectively. With KCl filling, a mean CPD increase from 18.65 (+/- 1.78) to 59.63 (+/- 0.5) at 100 mL and 110.82 (+/- 2.98) at full bladder capacity (270 mL) was observed. The CPD increase was significantly higher for KCl than with NaCl (p < 0.001). With NaCl filling, bladder neck blood flow increased from 22 TPU (empty) to 46 TPU (100 mL) and 62.5 TPU at C(max), compared to 22 TPU, 50 TPU and 102.5 TPU with KCl. CPD and TPU measurements showed a strong correlation at p = 0.01. In conclusion, transrectal power Doppler US image quantification is a feasible and accurate method for assessing blood flow changes in the urinary bladder neck.

Animals↗

Complication rate of transrectal ultrasound guided prostate biopsy: a comparison among 3 protocols with 6, 10 and 15 cores.

PURPOSE: We assessed the complication rate of ultrasound guided prostate biopsies performed at a single center in a screening population. Moreover the impact of different biopsy protocols comprising varying numbers of biopsy cores on the complication rate was evaluated. MATERIALS AND METHODS: A total of 5957 biopsies performed in 4303 clinically healthy men between January 1993 and August 2002 was evaluated retrospectively. Due to changes in the biopsy protocol, the number of biopsies obtained increased with time from 6 cores (January 1993 to October 1995) to 10 (November 1995 to March 2000) to 15 cores (March 2000 to August 2002). RESULTS: Minor complications such as hematospermia (36.3%), hematuria (14.5%) and rectal bleeding persisting for up to 2 days (2.3%) were noted frequently, while major complications requiring further treatment were far less common. Post-biopsy fever was seen in 48 patients (0.8%), rectal bleeding requiring surgical intervention or persisting for more than 2 days occurred in 36 patients (0.6%) and urinary retention was observed in 12 patients (0.2%). The increase in biopsy cores with time did not result in increased post-biopsy morbidity. Prostate cancer at biopsy was not associated with a higher complication rate. CONCLUSIONS: Prostate specific antigen screening has led to an increase in the number of patients undergoing prostate biopsy which, in turn, has increased the incidence of post-biopsy complications. However, most of the complications are minor and self-limiting. In this large study population the increased number of biopsy cores did not result in an increased incidence of major post-biopsy complications.

Adult↗

Value of transducer positions in the measurement of finger flexor tendon thickness by sonography.

OBJECTIVE: To assess the value of 2 transducer positions for measurement of finger flexor tendon thickness by sonography. METHODS: Flexor tendon thickness of the third finger was measured sonographically by 2 independent investigators in 20 healthy volunteers (n = 40 fingers) and in 4 cadaveric specimens (n = 4 fingers). Flexor tendon thickness was measured at histologic examination in the cadaveric specimens. We defined the area of the A1 annular pulley as position I and the area of the A2 annular pulley as position II. Sonographic measurements were performed in transverse (dorsovolar and radioulnar) and longitudinal planes. Interobserver and intraobserver variabilities were evaluated by each investigator performing 3 measurements at each position. RESULTS: In position I, volunteers had flexor tendon thickness of 2.7 to 4.0 mm (mean +/- SD, 3.28 +/- 0.26 mm) longitudinally; transversally the thickness was 2.5 to 4.0 mm (mean, 3.34 +/- 0.29 mm) dorsovolar and 5.5 to 8.9 mm (mean, 7.34 +/- 0.71) radioulnar in position I. Position II revealed thickness of 3.2 to 4.2 mm (mean, 3.6 +/- 0.23 mm) longitudinally; transversally the thickness was 2.7 to 4.1 mm (mean, 3.4 +/- 0.27) dorsovolar and 4.3 to 6.8 mm (mean, 5.27 +/- 0.65) radioulnar. Interobserver and intraobserver variability for position I was better than for position II (P < .01 versus P < .05). Sonographic findings correlated excellently with histologic findings (r2 = 0.94). CONCLUSIONS: Standardized transducer positions for sonographic measurements of finger flexor tendon thickness showed good interobserver and intraobserver variability. Position I was found to be more reliable than position II.

Adult↗

The influence of left renal vein entrapment on outcome after surgical varicocele repair: a color Doppler sonographic demonstration.

OBJECTIVE: To evaluate the impact of left renal vein entrapment on outcome after surgical varicocele repair using color Doppler sonography. METHODS: Eighty-four men had varicoceles on color Doppler sonography (2 right sided, 74 left sided, and 8 bilateral), which were diagnosed on the basis of a venous diameter of 3 mm or greater and venous retrograde flow in the pampiniform plexus of veins during the Valsalva maneuver or when changing from a supine to an upright position. Diagnosis of the left renal vein entrapment was based on the following criteria: antero-posterior diameter of greater than 1 cm and peak velocity of less than 15 cm/s for the left renal vein at the mid portion and anteroposterior diameter of less than 0.2 cm and peak velocity of greater than 110 cm/s (or, alternatively, a diameter ratio and peak velocity ratio of >5) for the left renal vein between the aorta and superior mesenteric artery. All patients underwent surgical varicocele repair. In postoperative follow-up, we compared the presence of left renal vein entrapment with the frequency of varicocele recurrence. RESULTS: Sixteen (19%) of 84 patients had left renal vein entrapment with a left-sided varicocele. Postoperatively (mean follow-up +/- SD, 19.3 +/- 11.7 months), 27 (32.2%) of 84 had varicocele recurrence, including all 16 patients with left renal vein entrapment and 11 (20.1%) of 68 patients without left renal vein entrapment. The varicocele recurrence rate was significantly greater in patients with left renal vein entrapment (P < .001, Fisher exact test). CONCLUSIONS: The presence of left renal vein entrapment resulted in a significantly higher varicocele recurrence rate. Patients with varicoceles should routinely be evaluated for the presence of left renal vein entrapment before surgical repair.

Adult↗

Age-related rhabdosphincter function in female urinary stress incontinence: assessment of intraurethral sonography.

OBJECTIVE: To assess dynamic intraurethral sonography in the diagnostic evaluation of the function of the rhabdosphincter in female patients with urinary stress incontinence in relation to patient age. METHODS: Sixty-two patients with clinically proved urinary stress incontinence were investigated by means of intraurethral sonography with a 12.5-MHz endoluminal 9F catheter. The omega-shaped rhabdosphincter was visualized at rest and during voluntary contractions. Changes of muscle thickness and transducer-sphincter distance were measured and considered as parameters of muscle function. The intraurethral sonographic data were compared with results of standard urodynamic tests. RESULTS: Transducer-sphincter distance and sphincter muscle thickness showed a significant decrease with positive linear dependency on patient age (P < .001). Patients with grade III urinary stress incontinence had complete loss of sphincter contractility. A negative correlation was revealed between urethral closure pressure and patient age. CONCLUSIONS: We found an age-related decrease in rhabdosphincter function. Our results suggest that the rhabdosphincter is a substantial component of the continence mechanism in female urinary stress incontinence. Unlike urethral pressure profiles, which can only reveal zones of higher intraluminal pressure, transurethral sonography is highly specific for measurement of the function of the rhabdosphincter.

Adult↗

Periprostatic administration of local anesthesia during transrectal ultrasound-guided biopsy of the prostate: a randomized, double-blind, placebo-controlled study.

OBJECTIVES: To evaluate the effect of periprostatic infiltration with local anesthesia on the level of discomfort associated with transrectal ultrasound-guided needle biopsy of the prostate. Transrectal ultrasound-guided needle biopsy of the prostate is the standard procedure to diagnose prostate cancer. METHODS: A prospective, randomized, double-blind study was performed on 100 men referred for biopsy of the prostate. Fifty subjects were randomized to periprostatic injection of 10 mL of 2% lidocaine solution without epinephrine, and 50 were randomized to injection of placebo (10 mL of 0.9% NaCl). Each subject completed three 10-point visual analog scales for pain after a series of 15 needle biopsies. Pain was rated during the biopsy, diagnostic investigation, and injection of lidocaine. RESULTS: Patients who received local anesthesia had significantly lower visual analog scale scores compared with the group without lidocaine during the biopsy (mean score 0.76 versus 3.62, P <0.001) and diagnostic examination (mean score 1.08 versus 1.86, P = 0.025). Lidocaine injection caused no adverse effects. CONCLUSIONS: Periprostatic injection of lidocaine represents a simple and safe procedure that significantly reduces discomfort during probe manipulation and biopsy. We recommend this procedure in men undergoing transrectal ultrasound-guided prostate biopsy.

Aged↗

The value of contrast-enhanced color Doppler ultrasound in the detection of vascularization of finger joints in patients with rheumatoid arthritis.

OBJECTIVE: A prospective study was performed to assess the usefulness of contrast-enhanced color Doppler ultrasound (CDUS) in the evaluation of intraarticular vascularization of finger joints in patients with rheumatoid arthritis (RA). METHODS: We investigated 198 finger joints in 46 patients with RA, and 80 finger joints in 10 healthy volunteers. Joints with varying levels of clinical activity of inflammation were classified as being active, moderately active, or inactive. CDUS was performed with a high-frequency multi-D linear array transducer. A microbubble-based ultrasound (US) contrast agent (Levovist; Schering, Berlin, Germany) was intravenously infused. Doppler findings were rated on the basis of both unenhanced and contrast-enhanced CDUS images. RESULTS: Healthy joints showed no intraarticular vascularization on either unenhanced or contrast-enhanced CDUS. Unenhanced CDUS detected intraarticular vascularization in 7 (8%) of 83 inactive joints, in 31 (52%) of 60 moderately active joints, and in 32 (58%) of 55 active joints. Contrast-enhanced CDUS detected intraarticular vascularization in 41 (49%) of 83 joints with inactive RA, in 59 (98%) of 60 joints with moderately active RA, and in all 55 joints with active RA. Detection of intraarticular vascularization was improved by administration of the microbubble-based US contrast agent (P < 0.001). Contrast-enhanced CDUS demonstrated differences in intraarticular vascularization between joints with inactive RA and those with active RA (P < 0.001), between joints with inactive RA and those with moderately active RA (P < 0.001), and between joints with moderately active RA and those with active RA (P < 0.001). CONCLUSION: The use of a microbubble-based US contrast agent significantly improved the detection of intraarticular vascularization in the finger joints of patients with RA. This technique seems to be a useful adjunct in the assessment of disease activity.

Adult↗

Laparoscopic pyeloplasty for UPJ obstruction with crossing vessels: contrast-enhanced color Doppler findings and long-term outcome.

OBJECTIVES: To evaluate, in the present long-term follow-up study, contrast-enhanced color Doppler imaging (CDI) findings and the clinical outcome of patients with crossing vessels at the obstructed ureteropelvic junction (UPJ), who underwent laparoscopic pyeloplasty. In a previous study, contrast-enhanced CDI proved capable of detecting crossing vessels at the UPJ. METHODS: A total of 23 patients, who had undergone laparoscopic pyeloplasty and displacement of crossing vessels for UPJ obstruction at least 2 years before this study (mean 27 months), underwent contrast-enhanced CDI, intravenous urography, and renography. Contrast-enhanced CDI was performed using intravenously administered Levovist to assess the displacement of the vessels relative to the UPJ. All patients completed analog follow-up pain scales and quality-of-life assessment questionnaires. RESULTS. Contrast-enhanced CDI revealed a cranial displacement (mean 1.3 cm) of the crossing vessels from the UPJ in all 23 cases. Intravenous urography showed a decrease in the degree of hydronephrosis, with a success rate of 100% in low-grade and 86% in high-grade hydronephrosis. The split renal function improved from 39.7% to 48.1%. Analog pain scale measurements demonstrated a mean improvement in pain of 92% (range 73% to 100%) and a mean quality-of-life score of 94 (range 78 to 100). CONCLUSIONS: Our series of patients with crossing vessels at the UPJ treated by laparoscopic pyeloplasty showed an excellent long-term successful outcome. Contrast-enhanced CDI allows for preoperative detection, as well as postoperative assessment, of the displacement of the crossing vessel. We recommend that the presence of a crossing vessel be routinely determined preoperatively, because it may influence the choice of treatment modality and thereby the clinical outcome.

Adolescent↗