PubMed Health⌕ Search

Biomedical subjects

Ferdinand Frauscher

Publications and source records attributed to Ferdinand Frauscher.

At least 19 recordsLinked to original sources

Value of contrast-enhanced ultrasound and elastography in imaging of prostate cancer.

PURPOSE OF REVIEW: Prostate cancer is the most commonly diagnosed malignancy in men. Gray-scale ultrasound-guided systematic biopsy is the standard of care for prostate cancer detection in men with an elevated prostate-specific antigen or an abnormal digital rectal examination. Systematic biopsy may miss up to 35% of clinically relevant cancers. Color and power Doppler ultrasound, ultrasound contrast agents, and elastography have and will dramatically change the role of ultrasound in prostate cancer diagnosis. RECENT FINDINGS: Several reports have demonstrated that contrast-enhanced ultrasound investigations of the blood flow of the prostate allow for prostate cancer visualization and therefore, for targeted biopsies. Comparisons between systematic and contrast-enhanced ultrasound-targeted biopsies have shown that the targeted approach detects more cancers with a lower number of biopsy cores. Furthermore, contrast-enhanced ultrasound has been shown to detect cancers with higher Gleason scores compared with the systematic approach, which seems to improve prostate cancer grading. In addition, elastography is a new ultrasound technique that allows for the assessment of tissue elasticity. SUMMARY: Contrast-enhanced ultrasound and elastography improve prostate cancer detection and may be useful for prostate cancer grading and staging. Future clinical trials will be needed to determine the promise of these new advances for ultrasound of the prostate evolving into clinical applications.

Humans↗

Value of 3-dimensional transrectal/transvaginal sonography in diagnosis of distal ureteral calculi.

OBJECTIVE: In a prospective study, the feasibility of 3-dimensional (3D) transrectal/transvaginal sonography in comparison with transabdominal sonography and intravenous urography (IVU) in identifying distal ureteral calculi was evaluated. METHODS: Sixty-two patients in the urologic clinic with clinical suspicion of distal ureteral calculi were included. The patients consisted of 44 men and 18 women with a mean age +/- SD of 44 +/- 17 years. These patients underwent 3D transrectal/transvaginal sonography, transabdominal sonography with IVU, and, finally, ureterorenoscopy. RESULTS: Fifty-nine patients were confirmed to have distal ureteral calculi on the basis of urologic intervention (ureterorenoscopy). Three patients had a spontaneous stone passage immediately after imaging completion. The median size of the calculi was 3.7 +/- 2.00 mm. Transabdominal sonography detected 34 of the 62 patients with calculi (sensitivity, 55%). The median size of the calculi was calculated as 5.0 +/- 2.4 mm. The examination time was 6.5 +/- 2.7 minutes. Intravenous urography detected 44 of the 62 patients with ureterolithiasis (sensitivity, 71%). Herein, the median stone size was measured as 3.9 +/- 1.9 mm, and the examination time was 38 +/- 17 minutes. The combination of transabdominal sonography and IVU in visualization of ureterolithiasis raised the sensitivity to 81% (50 of 62 patients). Three-dimensional transrectal/transvaginal sonography showed ureterolithiasis in all 62 patients confirmed to have distal ureteral calculi (sensitivity and specificity, 100%). The median size of the calculi was calculated as 4.4 +/- 2.2 mm, and the examination took 1.9 +/- 0.6 minutes. CONCLUSIONS: The data in our prospective study show that transrectal/transvaginal sonography with 3D image assessment is superior to IVU and abdominal sonography for diagnosing distal ureteral calculi.

Adult↗

Microbubble-enhanced ultrasound to deliver an antisense oligodeoxynucleotide targeting the human androgen receptor into prostate tumours.

We have shown recently that downregulation of the androgen receptor (AR), one of the key players in prostate tumor cells, with short antisense oligodeoxynucleotides (ODNs) results in inhibition of prostate tumor growth. Particularly with regard to an application of these antisense drugs in vivo, we now investigated the usefulness of microbubble-enhanced ultrasound to deliver these ODNs into prostate cancer cells. Our short antisense AR ODNs were loaded onto the lipid surface of cationic gas-filled microbubbles by ion charge binding, and delivered into the cells by bursting the loaded microbubbles with ultrasound. In vitro experiments were initially performed to show that this kind of delivery system works in principle. In fact, transfection of prostate tumor cells with antisense AR ODNs using microbubble-enhanced ultrasound resulted in 49% transfected cells, associated with a decrease in AR expression compared to untreated controls. In vivo, uptake of a digoxigenin-labelled ODN was found in prostate tumour xenografts in nude mice following intratumoral or intravenous injection of loaded microbubbles and subsequent exposure of the tumour to ultrasound, respectively. Our results show that ultrasound seems to be the driving force of this delivery system. Uptake of the ODN was also observed in tumors after treatment with ultrasound alone, with only minor differences compared to the combined use of microbubbles and ultrasound.

Androgen Receptor Antagonists↗

Three-dimensional ultrasonography of the urinary bladder: preliminary experience of assessment in patients with haematuria.

OBJECTIVE: To assess the value of three-dimensional (3D) vs two-dimensional (2D) ultrasonography (US) in the diagnostic evaluation of the urinary bladder in patients with haematuria. PATIENTS AND METHODS: In all, 42 patients with painless haematuria and/or irritative voiding symptoms were examined with 2D- and 3D-US. US was done with an Acuson Sequoia unit (Siemens Medical Sol. Mountain View, CA, USA) and the Perspective(R) 3D technique, to assess the presence of bladder lesions, including bladder cancer, bladder wall hypertrophy with trabeculation and diverticula, mucosal bladder folds or re-growth of the prostate mimicking a bladder tumour. The imaging findings were compared with cystoscopy and/or bladder biopsy. RESULTS: In 21 of the 42 patients (50%) cystoscopy with bladder biopsy revealed bladder cancer. Overall, 3D-US gave a correct diagnosis for 36 of 42 patients (86%). All 21 bladder cancers were correctly diagnosed, and 15 (71%) of the 21 benign bladder lesions were correctly identified. By contrast, 2D-US findings gave suspected bladder cancer in all patients. CONCLUSIONS: 3D-US is significantly more accurate than standard 2D-US in the diagnostic evaluation of patients with haematuria. Thus, this diagnostic technique might be useful for routine evaluation of the urinary bladder.

Aged↗

The use of three-dimensional computed tomography for assessing patients before laparoscopic adrenal-sparing surgery.

OBJECTIVE: To evaluate the efficacy of three-dimensional computed tomography (3D-CT) in delineating the relationship of the adrenal mass to adjacent normal structures in preparation for laparoscopic partial adrenalectomy. PATIENTS AND METHODS: Multislice CT (1 mm slices, 0.5 s rotation time) was used to evaluate 12 patients before adrenal-sparing surgery for aldosterone-producing adenoma or phaeochromocytoma. The CT data were reconstructed using two rendering techniques; (i) volume rendering with the modified VOLREN software (Johns Hopkins Hospital, Baltimore, MD, USA) which allowed interactive 3D examination of the whole data volume within a few minutes; (ii) surface representations only of the interesting structures (kidney, adrenal tumour, vessels) represented in different colours and depicted together in a 3D scene using the software package 3DVIEWNIX. RESULTS: In all, 14 adrenal masses in 12 patients were evaluated with 3D-CT; the number and location of lesions was accurate in all cases with both rendering techniques. The coloured surface-rendered images showed a consistently better delineation of the adrenal tumour from the normal tissue than did the volume-rendering technique. From this information all laparoscopic partial adrenalectomies could be completed as planned. CONCLUSIONS: Interactive visualization of volume-rendered CT images was helpful for the planning and successful performance of the procedure, but coloured surface-rendered CT provided more convenient, immediate and accurate intraoperative information.

Adenoma↗

Atherosclerosis as a risk factor for benign prostatic hyperplasia.

OBJECTIVES: To evaluate the relationship between clinical benign prostatic hyperplasia (BPH) and atherosclerosis, using colour Doppler ultrasonography (CDUS) and symptom scores. PATIENTS, SUBJECTS AND METHODS: CDUS was used to evaluate prostatic vascularity in four groups of men, comprising young healthy subjects, patients presenting with coronary artery disease (CAD), diabetes mellitus, or peripheral arterial occlusive disease (PAOD). Resistive index (RI) measurements and computer-assisted quantification of colour pixel density (CPD) were used to objectively evaluate perfusion. The International Prostate Symptom Score (IPSS) and the International Index of Erectile Function were used to quantify symptoms. RESULTS: In diabetic patients and men with PAOD, perfusion of the transition zone (TZ) of the prostate was significantly lower (P < 0.001) and the RI of the TZ was significantly higher (P < 0.001) than in healthy controls and men with CAD. In diabetics and men with PAOD, the mean prostate volume was greater than in healthy controls and men with CAD. The IPSS in patients with vascular damage (diabetes, PAOD) was significantly worse than in the control group. CONCLUSIONS: The significantly lower CPD and higher RI values of the TZ in patients with vascular disease than in healthy subjects support the hypothesis that an age-related impairment of blood supply to the prostate has a key role in the development of BPH.

Aged↗

Automated sonographic evaluation of testicular perfusion.

Contrast-enhanced ultrasound (US) imaging is potentially applicable to the investigation of vascular disorders of the testis. We investigated the ability of two automated computer algorithms to analyse contrast-enhanced pulse inversion US data in a rabbit model of unilateral testicular ischaemia and to correctly determine relative testicular perfusion: nonlinear curve fitting of the US backscatter intensity as a function of time; and spectral analysis of the intensity time trace. We compared (i) five metrics based on the algorithmic data to testicular perfusion ratios obtained with radiolabelled microspheres, a reference standard; (ii) qualitative assessment of the US images by two independent readers blinded to the side of the experimental and control testes to the radiolabelled microsphere perfusion ratios; and (iii) results of the algorithmically-derived metrics to the qualitative assessments of the two readers. For the curve fit method, the algorithmically-derived metrics agreed with the reference standard in 54% to 68% of all cases. For the spectral method, the results agreed in 70% of all cases. The two readers agreed with the reference standard in 40% and 35% of all cases, respectively. These results suggest that automated methods of analysis may provide useful information in the assessment of testicular perfusion.

Algorithms↗

Vascular resistance in the prostate evaluated by colour Doppler ultrasonography: is benign prostatic hyperplasia a vascular disease?

OBJECTIVE: To evaluate prostatic vascular resistance by measuring the resistive index (RI), and flow velocity using colour Doppler ultrasonography (CDUS), in normal prostates and in patients with benign prostatic hyperplasia (BPH) or prostate cancer, as BPH is considered to be a result of urogenital ageing and studies suggest that hyperplasia in the stromal and glandular compartments might be induced by stromal growth secondary to hypoxia, which in turn results from abnormal blood flow patterns. PATIENTS, SUBJECTS AND METHODS: Ninety-two men (22 with normal prostates, 45 with BPH and 25 with prostate cancer; mean age 56 years) were prospectively evaluated by CDUS. The RI values for the peripheral, central and transition zones were assessed by one investigator. The diagnosis of BPH and prostate cancer was established from histological findings. RESULTS: The mean (sd) RI in the transition zone was significantly higher only in patients with BPH, at 0.77 (0.05), vs 0.65 (0.05) in the other two groups. In the peripheral and central zones there was no significant difference in the RI among the three groups. Arterial CDUS flow velocity was increased in the transition zone of patients with BPH, but not in the peripheral and central zones. CONCLUSIONS: The present results support the hypothesis that an age-related impairment of blood supply to the lower urinary tract might have a role in the development of BPH. Although prostate cancer cannot be excluded by measuring RI, high RI values (>0.75) in the transition zone are indicative of BPH.

Adult↗

Pulse-inversion US imaging of testicular ischemia: quantitative and qualitative analyses in a rabbit model.

PURPOSE: To quantitatively and qualitatively assess perfusion with pulse-inversion (PI) ultrasonography (US) in rabbit model of acute testicular ischemia. MATERIALS AND METHODS: Institutional animal care committee approval was obtained. After 35 rabbits underwent unilateral spermatic cord occlusion, testicular Doppler US and contrast material-enhanced PI imaging were performed. Enhancement data yielded perfusion measurements including mean value during the first 10 seconds, mean value over entire recorded replenishment curve, and curve slope during the first 5 seconds. Calculated perfusion ratios were compared with radiolabeled microsphere-derived perfusion ratios. Two readers assessed testicular perfusion as none, possible, or definite and relative perfusion as greater to the right testis than to the left, greater to the left testis than to the right, or as equal to both testes. With kappa statistics, interobserver agreement for all imaging methods was determined. Association between qualitative perfusion categories and radiolabeled microsphere-based perfusion measurements was assessed. Quantitative and qualitative determinations of relative perfusion were compared with radiolabeled microsphere-based measurements. RESULTS: Correlations between calculated and radiolabeled microsphere-based perfusion ratios were determined (r=0.49-0.64). Interobserver agreement for presence of perfusion was excellent (kappa=0.76), and that for relative perfusion assessment was good (kappa=0.55). Neither kappa value varied significantly with imaging method. The percentage of times a testis classified as having definite perfusion had greater perfusion as measured with radiolabeled microspheres than a testis classified as having no perfusion or possible perfusion was higher with PI imaging than with Doppler US (85%-98% vs 72%-89%). Identification of the testis with less perfusion was better with quantitative methods than with qualitative assessment of images by the readers (75%-79% vs 34%-60%, P<.004). CONCLUSION: PI imaging, compared with conventional Doppler US methods, provides superior assessment of perfusion in the setting of acute testicular ischemia.

Acute Disease↗

A comparison of the diagnostic performance of systematic versus ultrasound-guided biopsies of prostate cancer.

Transrectal ultrasound (TRUS) is an important tool for urologists and radiologists in the detection of prostate cancer. Various TRUS-guided biopsy techniques are applied in clinical practice. Frequently, only the detection rates achieved with these methods are compared. Other diagnostic performance parameters, particularly the specificity and negative predictive value, are seldom compared. After extensive assessment of the available literature, this review describes the methods of TRUS-guided biopsy for prostate cancer detection. A distinction was made between systematic biopsies and biopsies that target a perceived (hypoechoic or Doppler-enhancing) lesion on imaging. Subsequently, the diagnostic performance (sensitivity, specificity, positive and negative predictive values, accuracies) was compared between these techniques. Imaging-guided biopsy showed better diagnostic performance than systematic biopsy with higher sensitivity. The combinations of sensitivity and specificity were highest for colour Doppler and contrast-enhanced targeted biopsy. Studies targeting hypoechoic lesions had relatively high sensitivity, but specificity was low. Presently however, with widespread prostate-specific antigen screening, fewer prostate cancers are hypoechoic, and the value of targeting hypoechoic lesions has diminished. Performing colour or contrast-enhanced Doppler biopsy or adding these techniques to systematic biopsies improves diagnostic performance, particularly by increasing sensitivity.

Biopsy↗

Dynamic transurethral sonography and 3-dimensional reconstruction of the rhabdosphincter and urethra: initial experience in continent and incontinent women.

OBJECTIVE: The purpose of this study was to evaluate the female urethra and the striated urinary sphincter, the rhabdosphincter (RS), by means of dynamic transurethral sonography and sonographic 3-dimensional (3D) reconstructions. METHODS: In 15 female patients with urinary stress incontinence (mean age, 67.5 years) and 5 continent women (mean age, 48.3 years), morphologic characteristics and function of the RS and urethra were examined with a 10-MHz transurethral ultrasound transducer. With the help of a mechanical pullback system, the transducer was slowly retracted to scan the whole urethra and the RS from the bladder neck to the urethral orifice. Subsequently, 3D reconstructions of the urethra using an integrated computer system were performed. The RS as well as the length of the urethra were investigated under contracted and noncontracted conditions to measure contractility of the RS and dynamic changes of the lower urinary tract. RESULTS: Partial or complete loss of RS function was detected in patients with stress incontinence. The findings on sonography were found to correlate well with the grade of incontinence. Furthermore, under contraction of the RS, a median increase in urethral length was observed. In incontinent patients, the increase in the urethral length was statistically significantly less (P = .04), which was related to the reduced contractility of the RS. CONCLUSIONS: Dynamic transurethral sonography with subsequent 3D reconstructions allows for assessment of function and morphologic characteristics of the RS and urethra. Normal contraction of the RS results in an elongation of the urethra.

Adolescent↗

Detection of prostate carcinoma with contrast-enhanced sonography using intermittent harmonic imaging.

BACKGROUND: The purpose of this study was to assess prostate carcinoma detection and discrimination of benign from malignant prostate tissue with contrast-enhanced ultrasonography. METHODS: In all, 301 subjects referred for prostate biopsy were evaluated with contrast-enhanced sonography using continuous harmonic imaging (CHI) and intermittent harmonic imaging (IHI) with interscan delay times of 0.2, 0.5, 1.0, 2.0 seconds, as well as continuous color and power Doppler. Targeted biopsy cores were obtained from sites of greatest enhancement, followed by spatially distributed cores in a modified sextant distribution. RESULTS: Carcinoma was detected in 363 biopsy cores from 104 of 301 subjects (35%). Carcinoma was found in 15.5% (175 of 1133) of targeted cores and 10.4% (188 of 1806) of sextant cores (P < 0.01). Among subjects with carcinoma, targeted cores were twice as likely to be positive (odds ratio [OR] = 2.0, P < 0.001). Clustered receiver operating characteristic (ROC) analysis of imaging findings at sextant biopsy sites yielded the following Az values: precontrast gray scale: 0.58; precontrast color Doppler: 0.53; precontrast power Doppler: 0.58; CHI: 0.62; IHI (0.2 sec): 0.64; IHI (0.5 sec): 0.63; IHI (1.0 sec): 0.65; IHI (2.0 sec): 0.61; contrast-enhanced color Doppler: 0.60; contrast-enhanced power Doppler: 0.62. A statistically significant benefit was found for IHI over baseline imaging (P < 0.05). CONCLUSIONS: The carcinoma detection rate of contrast-enhanced targeted cores is significantly higher when compared with sextant cores. Contrast-enhanced transrectal sonography with IHI provides a statistically significant improvement in discrimination between benign and malignant biopsy sites. However, given the relatively low ROC areas, this technique may not be sufficient to predict which patients have benign versus malignant disease.

Aged↗

Prostate ultrasound--for urologists only?

The value of ultrasound (US) in the diagnosis of prostate cancer has dramatically increased in the past decade. This is mainly related to the increasing incidence of prostate cancer, the most common cancer in men and one of the most important causes of death from cancer in men. The value of conventional gray-scale US for prostate cancer detection has been extensively investigated, and has shown a low sensitivity and specificity. Therefore conventional gray-scale US is mainly used by urologists for guiding systematic prostate biopsies. With the development of new US techniques, such as color and power Doppler US, and the introduction of US contrast agents, the role of US for prostate cancer detection has dramatically changed. Advances in US techniques were introduced to further increase the value of US contrast agents. Although most of these developments in US techniques, which use the interaction of the contrast agent with the transmitted US waves, are very sensitive for the detection of microbubbles, they are mostly unexplored, in particular for prostate applications. Early reports of contrast-enhanced US investigations of blood flow of the prostate have shown that contrast-enhanced US adds important information to the conventional gray-scale US technique. Furthermore, elastography or 'strain imaging' seems to have great potential in prostate cancer detection. Since these new advances in US are very sophisticated and need a long learning curve, radiologists, who are overall better trained with these new US techniques, will play a more important role in prostate cancer diagnosis. Current trends show that these new US techniques may allow for targeted biopsies and therefore replace the current 'gold standard' for prostate cancer detection--the systematic biopsy. Consequently the use of these new US techniques for the detection and clinical staging of prostate cancer is promising. However, future clinical trials will be needed to determine if the promise of these new US advances of the prostate evolves into clinical application.

Humans↗

Are transition zone biopsies still necessary to improve prostate cancer detection? Results from the tyrol screening project.

OBJECTIVES: The present retrospective study was designed to investigate the value of transition zone (TZ) biopsies for prostate cancer (PC) detection rate in a combined contrast enhanced color Doppler targeted (CECD) and gray-scale systematic biopsy (SB) approach. METHODS: PSA screening participants totalling 1475 with tPSA of >1.25 ng/ml (fPSA< or =18%) were assessed. Ten SB and additionally 5 or fewer CECD were performed. The impact of TZ biopsies on the PC detection rate and the biological significance of the detected TZ-cancers were analyzed. RESULTS: Out of 1475 biopsied patients, 395 (26.8%) were identified as PC patients; 5925 biopsy cores from these patients were analyzed. In 86 patients (21.8% of PC), we found 102 PC- positive cores in the TZ, and only in 9 of them solitary TZ-cancers without any other PC-location (2.3% of PC or 0.6% of all investigated patients). Pathologic findings after retropubic prostatectomy (RPE) revealed multifocal adenocarcinoma including involved peripheral zone (PZ) in eight of these nine patients, and solitary TZ-cancer in one patient. There was no positive correlation between prostate volume and TZ-detection rate and no patient with solitary TZ-PC after rebiopsy. CONCLUSION: Biopsy revealed 9 solitary TZ cancers (1.8%) and RPE revealed only one of them to be truly TZ-confined cancer (0.6%). Furthermore PC-detection did not improve, even in patients with rebiopsy, and there was no correlation between detection of TZ-cancers and prostate volume. A combined use of CECD and SB to investigate participants of a PSA-screening program suggests that TZ-biopsies do not improve PC detection rate and are therefore unnecessary.

Adult↗

Inflammatory low back pain: high negative predictive value of contrast-enhanced color Doppler ultrasound in the detection of inflamed sacroiliac joints.

OBJECTIVE: To determine the value of microbubble contrast agents for color Doppler ultrasound (CDUS) compared with magnetic resonance imaging (MRI) in the detection of active sacroiliitis. METHODS: An observational case-control study of 103 consecutive patients (206 sacroiliac [SI] joints) with inflammatory low back pain according to the Calin criteria and 30 controls (60 SI joints) without low back pain was conducted at the University Hospital of Innsbruck. All patients and controls underwent unenhanced and contrast-enhanced CDUS and MRI of the SI joints. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of unenhanced and contrast-enhanced CDUS were evaluated. RESULTS: Forty-three patients (41%) with 70 of 206 SI joints (34%) and none of the controls nor the 60 control SI joints demonstrated active sacroiliitis on MRI. Unenhanced CDUS showed a sensitivity of 17%, a specificity of 96%, a PPV of 65%, and an NPV of 72%; contrast-enhanced CDUS showed a sensitivity of 94%, a specificity of 86%, a PPV of 78%, and an NPV of 97%. Detection of vascularity in the SI joint was increased by contrast administration (P < 0.0001). Clustered receiver operating curve analysis demonstrated that enhanced CDUS (A(z) = 0.89) was significantly better than unenhanced CDUS (A(z) = 0.61) for the diagnosis of active sacroiliitis verified by MRI (P < 0.0001; 2-sided test). CONCLUSION: Microbubble contrast-enhanced CDUS is a sensitive technique with a high NPV for detection of active sacroiliitis compared with MRI.

Adult↗

Remitting seronegative symmetrical synovitis with pitting edema of the hands: ultrasound, color doppler ultrasound, and magnetic resonance imaging findings.

OBJECTIVE: To assess the value of gray-scale ultrasound (US), color Doppler ultrasound (CDUS), contrast-enhanced CDUS, and magnetic resonance imaging (MRI) in the diagnostic evaluation of the hands in patients with remitting seronegative symmetrical synovitis with pitting edema (RS3PE). METHODS: Eight patients (5 men, 3 women; mean +/- SD age 69.3 +/- 7.2 years) with clinical diagnosis of RS3PE syndrome underwent US, CDUS, contrast-enhanced CDUS, and MRI. US was performed with a linear array transducer operating at 12 MHz. The US contrast agent (SHU 508; Levovist, Schering, Germany) was intravenously infused in a concentration of 300 mg/ml at a rate of 1 ml/minute. RESULTS: All patients showed symmetric subcutaneous edema and synovitis of tendons and finger joints on both US and MRI. Vascularity was detected subcutaneously in tendon sheaths and in the joint synovia on CDUS and MRI. Detection of increased vascularity was improved after contrast administration compared with unenhanced CDUS (P < 0.01). CONCLUSION: Ultrasound, CDUS, contrast-enhanced CDUS, and MRI are valuable tools in the diagnostic evaluation of involved anatomic structures in patients with RS3PE. Contrast-enhanced CDUS is superior to CDUS in assessment of inflammatory edema, effusion, and synovitis.

Aged↗

Effects of local estrogen therapy on recurrent urinary tract infections in young females under oral contraceptives.

BACKGROUND: Previous studies have demonstrated the efficacy of local application of estrogen in treating postmenopausal women with recurrent urinary tract infections (RUTI) and urinary incontinence. Younger women under oral contraceptives (OC) can suffer from similar symptoms. The aim of this pilot study was to evaluate the effectiveness of local estrogens on RUTI and the impact of local hormonal supplementation on bladder neck vascularization. METHODS: 30 women (mean age 22.7 years) with a longstanding history of RUTI were included. Pre-treatment investigation included complete clinical history, urinalysis, urine culture and cystoscopy. All subjects completed a questionnaire about onset and duration of disease and quality of life before and after treatment. Local (vaginal) estrogen therapy consisted of 1mg estriol (E3) 7 times a week for two weeks and twice a week for two additional weeks. Sonographic examination of bladder vascularization was performed before and after treatment using transperineal color Doppler ultrasound (6 MHz, Acuson Sequoia 512, Mountain View, CA, USA) with a filled bladder. After angle correction, peak systolic blood flow velocity (PSBFV) and end diastolic blood flow velocity (EDBFV) were measured in 2 bladder arteries; and the Resistive Index (RI) was calculated. Flow velocity in each vessel was measured at least four times and the mean value determined. RESULTS: All patients completed the therapy course without severe side effects. Patients had a mean history of RUTI over 2.3 years; the mean period under OC was 3.2 years. In the follow-up period of 11 months after treatment, 24/30 patients reported no symptoms of cystitis and used no additional medication. Normal bladder epithelium in control cystoscopy after E3 therapy was seen in all patients with trigonal metaplasia and vulnerable, highly vascularized urothelium at the initial investigation. RI decreased from 0.945 to 0.705 after treatment (p<0.001), concomitantly the mean EDBFV increased highly significantly from 0.82 cm/sec to 4.45 cm/sec after estrogen treatment (p<0.001). INTERPRETATION: In a majority of young patients under OC and a longstanding history of RUTI, a considerable infection-free period was achieved after local application of estrogen. Decreased RI and increased EDBFV indicate vasodilatation and less peripheral vascular resistance. Responsiveness to local E3 may correspond to improved cystoscopic findings as a consequence of increased bladder perfusion.

Administration, Intravaginal↗

Detection rates and biologic significance of prostate cancer with PSA less than 4.0 ng/mL: observation and clinical implications from Tyrol screening project.

OBJECTIVES: To investigate the prostate cancer (PCa) detection rates and Gleason scores in patients with serum prostate-specific antigen (PSA) levels of 2.0 to 3.9 ng/mL and 4.0 to 10 ng/mL (free PSA 18% or less), in a population-based screening project. With the use of prostate-specific antigen (PSA) screening, more PCa is being diagnosed at PSA values of less than 4 ng/mL. METHODS: A total of 3446 consecutive screening volunteers with a PSA level of 2.0 to 10.0 ng/mL (free PSA 18% or less) were assessed. Ten systematic prostate biopsies and an additional five Doppler-enhanced targeted biopsies were performed on the basis of age-specific PSA reference ranges. The cumulative frequency of detection and the Gleason scores were analyzed. RESULTS: The PCa detection rate for patients with a PSA value of 2.0 to 3.9 ng/mL (n = 1522, group 1) and 4.0 to 10.0 ng/mL (n = 1924, group 2) was 21% (n = 320) and 30% (n = 572), respectively. Of the PCa cases detected, 37% were in men with a PSA level of 2 to 4 ng/mL. Statistically significant differences were found in age and prostate volume between groups 1 and 2, with patients in the lower PSA group younger and having a smaller mean prostate volume (P = 0.0001). Of 313 patients with PCa and a PSA value of 2 to 3.9 ng/mL, 24% had a Gleason score of 7 or greater compared with 33% of 560 patients with a PSA value of 4.0 to 10.0 ng/mL (P = 0.004). CONCLUSIONS: Our data suggest that in a screening population, more than one third of PCa cases in men with a PSA level of 2 to 10 ng/mL will occur in those with a PSA value of 2 to 3.9 ng/mL. Also, PCa cases with a low PSA level occur in younger patients and at lower stages with a smaller prostate volume.

Adult↗