PubMed Health⌕ Search

Biomedical subjects

François Estève

Publications and source records attributed to François Estève.

17 recordsLinked to original sources

Motexafin-gadolinium taken up in vitro by at least 90% of glioblastoma cell nuclei.

PURPOSE: We present preclinical data showing the in vitro intranuclear uptake of motexafin gadolinium by glioblastoma multiforme cells, which could serve as a prelude to the future development of radiosensitizing techniques, such as gadolinium synchrotron stereotactic radiotherapy (GdSSR), a new putative treatment for glioblastoma multiforme. EXPERIMENTAL DESIGN: In this approach, administration of a tumor-seeking Gd-containing compound would be followed by stereotactic external beam radiotherapy with 51-keV photons from a synchrotron source. At least two criteria must be satisfied before this therapy can be established: Gd must accumulate in cancer cells and spare the normal tissue; Gd must be present in almost all the cancer cell nuclei. We address the in vitro intranuclear uptake of motexafin gadolinium in this article. We analyzed the Gd distribution with subcellular resolution in four human glioblastoma cell lines, using three independent methods: two novel synchrotron spectromicroscopic techniques and one confocal microscopy. We present in vitro evidence that the majority of the cell nuclei take up motexafin gadolinium, a drug that is known to selectively reach glioblastoma multiforme. RESULTS: With all three methods, we found Gd in at least 90% of the cell nuclei. The results are highly reproducible across different cell lines. The present data provide evidence for further studies, with the goal of developing GdSSR, a process that will require further in vivo animal and future clinical studies.

Brain Neoplasms↗

Prolonged survival of Fischer rats bearing F98 glioma after iodine-enhanced synchrotron stereotactic radiotherapy.

PURPOSE: Heavy-atom-enhanced synchrotron stereotactic radiotherapy (SSR) is a treatment that involves selective accumulation of high-Z elements in tumors followed by stereotactic irradiation with X-rays from a synchrotron source. The purpose of this study was to determine whether the efficacy of iodine-enhanced SSR could be further improved in the F98 rodent glioma model, by using a concomitant injection of an iodinated contrast agent and a transient blood-brain barrier opener (mannitol) during irradiation. METHODS AND MATERIALS: Fourteen days after intracerebral inoculations of F98 cells, the rats were irradiated with 50-keV X-rays while receiving an infusion of hyperosmotic mannitol with iodine, either intravenously or via the carotid (9 to 15 rats per group, 117 rats total). RESULTS: For doses<or=15 Gy, the intracarotid infusion of mannitol and iodine improved the rats' survival compared with intravenous injection or irradiation alone. The percentage-increased life spans (ILS) were 91%, 116%, and 169% without iodine, after infusion of iodine and mannitol intravenously, and intracarotid, respectively (15 Gy). At 25 Gy, the rats irradiated without iodine had the longest survival (ILS=607%), but no additional benefit was obtained with iodine and mannitol. CONCLUSIONS: Iodine-enhanced SSR is significantly improved with concomitant intracarotid infusion of iodine and mannitol for radiation doses<or=15 Gy.

Animals↗

Monte Carlo dosimetry for synchrotron stereotactic radiotherapy of brain tumours.

A radiation dose enhancement can be obtained in brain tumours after infusion of an iodinated contrast agent and irradiation with kilovoltage x-rays in tomography mode. The aim of this study was to assess dosimetric properties of the synchrotron stereotactic radiotherapy technique applied to humans (SSR) for preparing clinical trials. We designed an interface for dose computation based on a Monte Carlo code (MCNPX). A patient head was constructed from computed tomography (CT) data and a tumour volume was modelled. Dose distributions were calculated in SSR configuration for various energy beam and iodine content in the target volume. From the calculations, it appears that the iodine-filled target (10 mg ml(-1)) can be efficiently irradiated by a monochromatic beam of energy ranging from 50 to 85 keV. This paper demonstrates the feasibility of stereotactic radiotherapy for treating deep-seated brain tumours with monoenergetic x-rays from a synchrotron.

Brain Neoplasms↗

Irradiation in presence of iodinated contrast agent results in radiosensitization of endothelial cells: consequences for computed tomography therapy.

PURPOSE: To date, iodinated contrast agents (ICA) are commonly used in medical imaging to improve tumor visualization by attenuating scanners X-rays. However, some adverse reactions to ICAs are still reported, and their molecular origin remains unclear. In 1983, it was proposed to visualize and treat ICA-loaded tumors by using scanners as therapy machines to enhance X-rays absorption at the iodine atoms. Theoretically, such physical conditions are optimized at 50 keV and can be easily obtained with synchrotrons. METHODS AND MATERIALS: Here, we examined the molecular and cellular responses of mammalian endothelial cells to radiation in the presence of iomeprol, one of the most extensively used ICAs. RESULTS: Irradiation with X-rays at 50 keV in the presence of iomeprol produced a strong radiosensitization effect. The same conclusion was reached with a standard medical irradiator but to a lesser extent. While such treatment did not produce additional DNA double-strand breaks, we observed a dose-dependent production of iodides due to the iomeprol radiolysis that inhibit double-strand break repair rate by decreasing DNA-PK kinase activity. CONCLUSIONS: Our data suggest that the concomitant use of ICA and radiation may be toxic when radiation-produced iodide concentrations and double-strand break yields are sufficient. The potential toxicity of ICAs during X-rays for diagnosis and therapy is discussed.

Animals↗

Sensitivity variation of doped Fricke gel irradiated with monochromatic synchrotron X rays between 33.5 and 80 keV.

An experimental binary radiotherapy proposes the concomitant use of a high-Z compound and synchrotron X rays for enhancing radiation dose selectively in tumours by a photoelectric effect. This study aimed at measuring the resulting dose enhancement in irradiated material. A doped Fricke gel dosemeter model was manufactured with 10 mg ml(-1) of iodine (Telebrix) or barium (Micropaque). Samples were irradiated with a monochromatic synchrotron beam at 33.5, 50, 65 and 80 keV. The ensuing enhancement of the sensitivity of the dosemeter was derived from the nuclear magnetic resonance relaxation rates measured at different X-ray doses. Our results demonstrate (1) the preservation of a linear relationship between relaxation rates and X-ray doses for dosemeters doped with high-Z atoms and (2) a clear energy-dependent sensitivity enhancement for barium-doped Fricke gels. This enhancement was neither reproducible with iodinated compounds nor clearly related to the expected dose enhancement factor. However 1% barium sulphate in the gel could significantly improve the gel's response when it was irradiated by low-energy X rays.

Barium Sulfate↗

Enhanced delivery of iodine for synchrotron stereotactic radiotherapy by means of intracarotid injection and blood-brain barrier disruption: quantitative iodine biodistribution studies and associated dosimetry.

PURPOSE: Synchrotron stereotactic radiotherapy (SSR) is a binary cancer treatment modality that involves the selective accumulation of a high Z element, such as iodine, in tumors, followed by stereotactic irradiation with kilovoltage X-rays from a synchrotron source. The success of SSR is directly related to the absolute amount of iodine achievable in the tumor. The purposes of this preclinical study were to determine whether the delivery of iodine to brain tumor models in rats could be enhanced by the means of its intracarotid injection with or without a hyperosmotic solution and to evaluate corresponding absorbed X-ray doses. METHODS AND MATERIALS: Experiments were performed on four groups of F98 glioma-bearing rats, which received either intracarotid (IC) or intravenous (IV) infusions of a mixture (6 mL in 12 min) of an iodinated contrast agent associated or not with a transient blood-brain barrier opener (mannitol). The mixture volumetric proportions were 8/13 of Iomeron (C = 350 mg/mL) for 5/13 of mannitol or saline, respectively. Absolute iodine concentration kinetic was measured in vivo in the tumor, blood, contralateral and ipsilateral brain, and muscle by monochromatic computed tomography. Associated dosimetry was performed by computing the iodine dose enhancement factor (DEF) in each region and building dose distribution maps by analytical simulations. RESULTS: Infusion of mannitol significantly enhanced iodine tumor uptake compared with the control values (p < 0.0001 and p = 0.0138, for IC and IV protocols, respectively). The mean iodine concentrations (C) reached 20.5 +/- 0.98 mg/mL (DEF = 4.1) after administration of iodine and mannitol vs. 4.1 +/- 1.2 mg/mL i.c. with serum (DEF = 1.6). The tumor iodine uptakes after jugular injection with mannitol (C = 4.4 +/- 2.1 mg/mL, DEF = 1.7) were not significantly different from IC injection of iodine without mannitol (p = 0.8142). The IV injection of iodine with saline led to an iodine concentration in the tumor of 1.2 +/- 0.98 mg/mL and a DEF of 1.2. CONCLUSIONS: This study established that optimizing the delivery of iodine by means of IC injection combined with a blood-brain barrier opener (mannitol) significantly increases the iodine uptake of F98 rat gliomas. This infusion protocol could potentially enhance the efficacy of SSR treatment, because the radiation dose is proportional to the iodine amount present in the irradiation bed.

Animals↗

Comparison of synchrotron radiation angiography with conventional angiography for the diagnosis of in-stent restenosis after percutaneous transluminal coronary angioplasty.

AIMS: Synchrotron radiation angiography (SRA) is a novel tool for minimally invasive coronary artery imaging. The method uses subtraction of two images produced at energies bracketing the iodine K-edge after intravenous infusion of iodinated contrast agent. We investigated the accuracy of SRA for detecting in-stent restenosis (ISR). METHODS AND RESULTS: We recruited 57 men, 4-6 months after successful PTCA. We visualized the right coronary artery (RCA) in 27 patients with 36 stented segments [12 segments with ISR>50% by quantitative coronary angiography (QCA)], and the left anterior descending artery (LAD) in 30 patients with 37 stented segments (10 ISR). SRA and QCA were performed within 2 days of each other. Two experienced observers unaware of QCA data evaluated the SRA results. Image quality was good or excellent in most patients. Global sensitivity was 64%, specificity was 95%, and positive and negative predictive values were approximately 85%. Inter-observer kappa concordance coefficient was 0.86. False negatives involved short eccentric lesions and superimposed segments, most frequently of the LAD. False positives occurred in intermediate stenoses slightly overestimated by SRA. CONCLUSION: In men, this minimally invasive approach, using small radiation doses, detects significant ISR in the RCA, but the LAD poses difficulties because of superimposition with others structures.

Adult↗

Quantitative analysis of synchrotron radiation intravenous angiographic images.

A medical research protocol on clinical intravenous coronary angiography has been completed at the European Synchrotron Radiation Facility (ESRF) biomedical beamline. The aim was to investigate the accuracy of intravenous coronary angiography based on the K-edge digital subtraction technique for the detection of in-stent restenosis. For each patient, diagnosis has been performed on the synchrotron radiation images and monitored with the conventional selective coronary angiography method taken as the golden standard. In this paper, the methods of image processing and the results of the quantitative analysis are described. Image processing includes beam harmonic contamination correction, spatial deconvolution and the extraction of a 'contrast' and a 'tissue' image from each couple of radiograms simultaneously acquired at energies bracketing the K-edge of iodine. Quantitative analysis includes the estimation of the vessel diameter, the calculation of the absolute iodine concentration profiles along the coronary arteries and the stenosis degree measurement.

Algorithms↗

High-resolution blood-brain barrier permeability and blood volume imaging using quantitative synchrotron radiation computed tomography: study on an F98 rat brain glioma.

The authors previously provided evidence of synchrotron radiation computed tomography (SRCT) efficacy for quantitative in vivo brain perfusion measurements using monochromatic X-ray beams. However, this technique was limited for small-animal studies by partial volume effects. In this paper, high-resolution absolute cerebral blood volume and blood-brain barrier permeability coefficient measurements were obtained on a rat glioma model using SRCT and a CCD camera (47x47 microm2 pixel size). This is the first report of in vivo high-resolution brain vasculature parameter assessment. The work gives interesting perspectives to quantify brain hemodynamic changes accurately in healthy and pathological small animals.

Animals↗

Synchrotron stereotactic radiotherapy: dosimetry by Fricke gel and Monte Carlo simulations.

Synchrotron stereotactic radiotherapy (SSR) consists in loading the tumour with a high atomic number element (Z), and exposing it to monochromatic x-rays from a synchrotron source (50-100 keV), in stereotactic conditions. The dose distribution results from both the stereotactic monochromatic x-ray irradiation and the presence of the high Z element. The purpose of this preliminary study was to evaluate the two-dimensional dose distribution resulting solely from the irradiation geometry, using Monte Carlo simulations and a Fricke gel dosimeter. The verification of a Monte Carlo-based dosimetry was first assessed by depth dose measurements in a water tank. We thereafter used a Fricke dosimeter to compare Monte Carlo simulations with dose measurements. The Fricke dosimeter is a solution containing ferrous ions which are oxidized to ferric ions under ionizing radiation, proportionally to the absorbed dose. A cylindrical phantom filled with Fricke gel was irradiated in stereotactic conditions over several slices with a continuous beam (beam section = 0.1 x 1 cm2). The phantom and calibration vessels were then imaged by nuclear magnetic resonance. The measured doses were fairly consistent with those predicted by Monte Carlo simulations. However, the measured maximum absolute dose was 10% underestimated regarding calculation. The loss of information in the higher region of dose is explained by the diffusion of ferric ions. Monte Carlo simulation is the most accurate tool for dosimetry including complex geometries made of heterogeneous materials. Although the technique requires improvements, gel dosimetry remains an essential tool for the experimental verification of dose distribution in SSR with millimetre precision.

Calibration↗

Cure of Fisher rats bearing radioresistant F98 glioma treated with cis-platinum and irradiated with monochromatic synchrotron X-rays.

High-grade gliomas are usually of poor prognosis, and conventional radiotherapy, even combined with chemotherapy, still fails to improve the survival of patients. Here, we propose an innovative therapeutic approach combining synchrotron radiation with cis-diamminedichloroplatinum (II) (CDDP). As suggested previously, monochromatic synchrotron irradiation of CDDP at 78.8 keV, just above the 78.4 keV platinum absorption K-edge, leads to an enhanced photoelectric effect and an increased local toxicity. To select a particular radiation energy that could provide supra-additive effect, we used pulsed-field gel electrophoresis to assess yields of DNA double-strand breaks induced in rat F98 glioma cells after CDDP treatment combined with synchrotron X-rays. Thereafter, intracerebral CDDP injection combined with synchrotron X-rays was applied to Fisher rats bearing F98 glioma. CDDP concentrations were mapped by synchrotron X-ray microfluorescence. An extra number of more slowly repaired double strand breaks were observed when irradiating CDDP-treated F98 cells at 78.8 keV. In vivo treatments were then performed with different radiation doses and CDDP concentrations. All cell inoculations in rat brain resulted in tumor development, and tumor presence was controlled by computed tomography. Among all of the conditions tested, the combination of 3 micro g of CDDP with 15 Gy resulted in the largest median survival time (206 days). After 1 year, about 34% of treated rats were still alive. This preclinical finding, validated by molecular analysis, represents the most protracted survival reported with this radioresistant glioma model and demonstrates the interest in powerful monochromatic X-ray sources as new tools for cancer treatments.

Animals↗

In vivo measurement of gadolinium concentration in a rat glioma model by monochromatic quantitative computed tomography: comparison between gadopentetate dimeglumine and gadobutrol.

RATIONALE AND OBJECTIVES: Monochromatic quantitative computed tomography allows a nondestructive and quantitative measurement of gadolinium (Gd) concentration. This technique was used in the C6 rat glioma model to compare gadopentetate dimeglumine and gadobutrol. METHODS: Rats bearing late-stage gliomas received 2.5 mmol/kg (392.5 mg Gd/kg) of gadopentetate dimeglumine (n = 5) and gadobutrol (n = 6) intravenously before the imaging session performed at the European Synchrotron Radiation Facility. RESULTS: Monochromatic quantitative computed tomography enabled in vivo follow-up of Gd concentration as a function of time in specified regions of interest. Surprisingly, after gadobutrol injection, Gd concentrations in the center and periphery of the tumor were higher than those after gadopentetate injection, although identical in normal and contralateral area of the brain. CONCLUSION: The in vivo assessment of absolute Gd concentrations revealed differences in gadobutrol and gadopentetate dimeglumine behaviors in tumoral tissues despite injections in the same conditions. These differences might be attributed to different characteristics of the contrast agents.

Animals↗

Synchrotron radiation therapy of malignant brain glioma loaded with an iodinated contrast agent: first trial on rats bearing F98 gliomas.

PURPOSE: Enhancement of the radiation dose delivered to a brain tumor can be achieved by infusing an iodinated contrast agent to the patient and irradiating with kilovoltage X-rays in computed tomography (CT) mode. Synchrotron sources, providing monochromatic tunable intense beams, are ideal for this treatment. The aim of this study is to assess in vivo the efficiency of this novel radiotherapy modality, Synchrotron Radiation CT-Therapy. MATERIALS AND METHODS: Intracranial implantations of 10(5) F98 glioma cells were performed on 18 Fisher 344 rats. Six rats were untreated controls, six received radiotherapy alone (10 Gy in the tumor by single fraction tomographic irradiation at 50 keV), and six received the same radiotherapy treatment under a continuous infusion of iodinated contrast agent. RESULTS: The rats that received contrast agent during radiotherapy survived significantly longer than rats that received radiotherapy alone (p = 0.025). Mean survival times (mean +/- SD) were 12.3 +/- 0.8, 14.8 +/- 2.8, and 18.2 +/- 1.3 days; median survival times were 12.5, 15, and 18 days (untreated controls, irradiated without iodine, irradiated with iodine, respectively). The increase in life spans was 20% and 44% for the rats irradiated without or with iodine, respectively. CONCLUSIONS: This method of radiation dose enhancement in brain tumors with synchrotron radiation significantly increases survival and appears highly promising.

Algorithms↗

Synchrotron photoactivation of cisplatin elicits an extra number of DNA breaks that stimulate RAD51-mediated repair pathways.

Combination of cis-platinum with ionizing radiation is one of the most promising anticancer treatments that appears to be more efficient than radiotherapy alone. Unlike conventional X-ray emitters, accelerators of high energy particles like synchrotrons display powerful and monochromatizable radiation that makes the induction of an Auger electron cascade in cis-platinum molecules [also called photoactivation of cis-platinum (PAT-Plat)] theoretically possible. Here, we examined the molecular consequences of one of the first attempts of synchrotron PAT-Plat, performed at the European Synchrotron Research Facility (Grenoble-France). PAT-Plat was found to result in an extra number of slowly repairable DNA double-strand breaks, inhibition of DNA-protein kinase activity, dramatic nuclear relocalization of RAD51, hyperphosphorylation of the BRCA1 protein, and activation of proto-oncogenic c-Abl tyrosine kinase.

Active Transport, Cell Nucleus↗

An objective method to measure cell survival by computer-assisted image processing of numeric images of Petri dishes.

This work establishes an objective method to measure cell clonogenic survival by computer-assisted image processing using images of cell cultures fixed and stained in Petri dishes. The procedure, developed by Samba Technologies, consists of acquiring Petri dish pictures with a desktop scanner and analysing them by computer, using algorithms based on the 'top hat' filter. The results from the automated count for the cell line SQ20B are compared with those found by two observers, before and after normalization of the counting. After normalization, the shape of the survival curves of the 'manual' counting of the Petri dishes shows a good correlation between both observers. The software enables the small visible differences in count between observers to be eliminated. The comparison between the absolute number of colonies shows an increased difference between the two manual scorings that can be as great as 67 colonies, whereas the difference between the two automated counts is never greater than 8 colonies. These results demonstrate that the 'manual' count is inter- and intraobserver variable, whereas the automatic count performs reproducible cell colony counts, thereby minimizing user-generated bias. The large amount of data produced also gives information about cell and colony characteristics. Thus, this computer-assisted method has considerably improved the reliability of our statistical results.

Algorithms↗

Absolute cerebral blood volume and blood flow measurements based on synchrotron radiation quantitative computed tomography.

Synchrotron radiation computed tomography opens new fields by using monochromatic x-ray beams. This technique allows one to measure in vivo absolute contrast-agent concentrations with high accuracy and precision, and absolute cerebral blood volume or flow can be derived from these measurements using tracer kinetic methods. The authors injected an intravenous bolus of an iodinated contrast agent in healthy rats, and acquired computed tomography images to follow the temporal evolution of the contrast material in the blood circulation. The first image acquired before iodine infusion was subtracted from the others to obtain computed tomography slices expressed in absolute iodine concentrations. Cerebral blood volume and cerebral blood flow maps were obtained after correction for partial volume effects. Mean cerebral blood volume and flow values (n = 7) were 2.1 +/- 0.38 mL/100 g and 129 +/- 18 mL. 100 g-1. min-1 in the parietal cortex; and 1.92 +/- 0.32 mL/100 g and 125 +/- 17 mL. 100 g-1. min-1 in the caudate putamen, respectively. Synchrotron radiation computed tomography has the potential to assess these two brain-perfusion parameters.

Animals↗